FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zephyr Technology Corporation/
  3. VZ6-USB1

VZ6-USB1900 MHZ USB DONGEL RECEIVER

Zephyr Technology Corporation
900 MHZ USB DONGEL RECEIVER - FCC ID VZ6-USB1 - Zephyr Technology Corporation
Click to zoom

Application Details

Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Date of Grant
Feb 03, 2008
Application Purpose
Original Equipment
Date of Application
Feb 03, 2008
Equipment Note
900 MHZ USB DONGEL RECEIVER
Frequency Range
902.20000000 - 927.80000000
Company
Zephyr Technology Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

BioHarness™ User Guide Page 2 of 43 © Zephyr Technology 2007 9700.0012.v1c Contacts Email: [email protected] Web: www.zephyr-technology.com Phone: +64 9 574 6523 Fax: +64 9 574 6527 Your BioHarness™ System comprises : • BioHarness™ Garment incorporating Zephyr Smart Fabric sensors • BioHarness™ Device • 1 docking/charging cradle • 1 USB lead • 1 USB radio receiver dongle • 1 Installation CD comprising o Application software o .NET installation software o USB driver folder o User Guide o Adobe PDF Reader Installer o Sample BioHarness™ projects Folder • 1 User Guide (black & white) • 1 Software & Hardware Installation Guide The information in this document is believed to be accurate in all respects at the time of publication but is subject to change without notice. Zephyr Technology assumes no responsibility for errors or omissions, and disclaims responsibility for any consequences resulting from the use of information included herein. Additionally, Zephyr Technology assumes no responsibility for the functioning of undescribed features or parameters. Zephyr Technology does not assume any liability arising out of the application or use of any product, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Zephyr Technology products are not designed, intended or authorised for use in applications intended to support or sustain life, or for any application in which the failure of the Zephyr Technology product could create a situation where personal injury or death may occur. Should Buyer purchase or use Zephyr Technology products for any such unintended or unauthorised application, Buyer shall indemnify and hold Zephyr Technology harmless against all claims and damages. Page 3 of 43 9700.0012.v1c © Zephyr Technology 2007 Contents Section Page 1 System Overview.............................................. 1.1 BioHarness System........................................... 1.2 BioHarness Application Software.......................... 1.3 BioHarness Garment and Device.......................... 1.4 Care and Maintenance....................................... 2 Technical Specifications..................................... 3 Get Started...................................................... 3.1 Precautions...................................................... 4 User Notes and Advice....................................... 5 Charge the Batteries.......................................... 6 Put on the Garment............................................ 7 View Live Data.................................................. 8 Record & Save Files.......................................... 9 View Saved Files............................................... 10 Log on the Device............................................. 11 Import Logs from the BioHarness Device................ 12 Read the Graphs............................................... 13 Compare Files.................................................. 14 Understand Graph Options.................................. 15 Export to an External csv File............................... 16 Understand External Data Files........................... 17 Change Settings................................................ 18 Sample BioHarness Data Files............................. 19 Troubleshooting................................................ 20 Glossary.......................................................... 21 Index............................................................... 22 Warranty......................................................... Page 4 of 43 © Zephyr Technology 2007 9700.0012.v1c 1 System Overview 1.1 BioHarness™ System The Zephyr BioHarness is a state-of-the-art lightweight portable biological data collection and analysis system. It monitors, analyses and records a variety of physiological parameters. The system can operate in two modes: RF (Radio Frequency) Transmitting mode for live viewing of data Logging mode for remote monitoring of data Live data viewing features include • A variety of selectable waveforms and trend data including o 250 Hz indicative ECG o 18 Hz respiration and Heart Rate RR data o 1 Hz for all trend, activity and 3-axis acceleration-based parameters • Real time pulse and breath detection indicator icons • Activity level in VMU • Posture – attitude of device – in degrees from vertical • Recording of data Historical and Logged data can be displayed. Exact data values can be determined by cursor position, with zoom and pan facilities on graphs. All data can be exported to an external csv file with real-time timestamps for more detailed analysis. Download data using USB docking cradle Wear & record Graphic display USB ISM receiver BioHarness garment and Device ISM radio link Graphic display Section 1 Page 5 of 43 9700.0012.v1c © Zephyr Technology 2007 1.2 BioHarness Application Software Toolbar Options Open New Project Play current project Browse for existing Project Record current RF data Save current project Stop current recording Connect (RF mode) Tools Zoom In around graph Cursor Zoom out Explorer Panel Graph Selection Cursor Value Active Icon Section 1 Page 6 of 43 © Zephyr Technology 2007 9700.0012.v1c Button (from off) LED Mode LED Mode Press & Hold Press again Press & Hold 3 sec RF Transmit Fast Logging Slow Off Off 1.3 BioHarness Garment and Device 1.4 Button/LED Modes 1.4 Care and Maintenance BioHarness Device: • O-ring sealed and water resistant. • Wipe with a soft damp cloth and towel-dry • Clean the Temperature window with a cotton bud • Do not leave in direct sunlight for long periods (such as in a vehicle) BioHarness Garment: • Rinse the garment in fresh water after use • Hand wash, or to machine wash the garment, detach the BioHarness Device and wash on a Cold, Delicate setting • Firmly attach the Velcro ® fastenings together and do not wash with other delicate garments which may be damaged by the fastenings. Use a washing pouch if possible. • Do …

Text truncated - open the document above for the full version.

Cover Letter(s)

The following documents are related to the items listed on the letter requesting confidentiality for the device listed as FCC ID: VZ6-USB1 (Zephyr Technology USB Receiver) The items are: Circuit diagrams, Schematic diagrams, Layout diagrams: dongle Schem.pdf Part Lists: dongle Partslst.pdf Operational description: dongle OpDes.pdf Block diagrams: dongle BlkDia.pdf

External Photos

BioHarness™ PCB (top) BioHarness™ RF Receiver (top) EMC Technologies (NZ) Ltd Test Report No 80137.2 Report date: 30 January 2008 EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 11 of 14 This report may not be reproduced except in full 9. PHOTOGRAPHS - External View BioHarness™ RF Receiver (bottom) BioHarness™ RF Receiver PCB (top)

ID Label/Location Info

ZDXXXXX FCC ID VZ6-USB1 IC: 7565A-USB1 26mm 8mm

Internal Photos

BioHarness™ RF Receiver (bottom) BioHarness™ RF Receiver PCB (top) BioHarness™ RF Receiver PCB (bottom) BioHarness™ Cradle (top)

Test Report

EMC Technologies (NZ) Ltd Test Report No 80137.2 Report date: 30 January 2008 EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 1 of 14 This report may not be reproduced except in full TEST REPORT Zephyr Technology Ltd BioHarness Physiological Monitoring Device USB Dongle Receiver tested to the Code of Federal Regulations (CFR) 47 Part 15 – Radio Frequency Devices, for Zephyr Technology Ltd This Test Report is issued with the authority of: _____________________________ Andrew Cutler - General Manager EMC Technologies (NZ) Ltd Test Report No 80137.2 Report date: 30 January 2008 EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 2 of 14 This report may not be reproduced except in full Table of Contents 1. CLIENT INFORMATION 3 2. DESCRIPTION OF TEST SAMPLE 3 3. COMPLIANCE STATEMENT 4 4. TEST SAMPLE DESCRIPTION 4 5. ATTESTATION 5 6. TRANSMITTER TEST RESULTS 6 7. TEST EQUIPMENT USED 10 8. ACCREDITATIONS 10 9. PHOTOGRAPHS 11 EMC Technologies (NZ) Ltd Test Report No 80137.2 Report date: 30 January 2008 EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 3 of 14 This report may not be reproduced except in full 1. CLIENT INFORMATION Company Name Zephyr Technology Ltd Address 31 Carbine Road Mount Wellington City Auckland Country New Zealand Contact Mr James Sirois 2. DESCRIPTION OF TEST SAMPLE Brand Name Zephyr Technology Ltd Model Number BioHarness Product Physiological Monitoring Device USB Dongle Receiver Manufacturer Zephyr Technology Ltd Country of Origin New Zealand Serial Numbers ZD000075 Ancillary Equipment - ASUS A3F Laptop Computer SN# 65N0AG003012 EMC Technologies (NZ) Ltd Test Report No 80137.2 Report date: 30 January 2008 EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 4 of 14 This report may not be reproduced except in full 3. COMPLIANCE STATEMENT The Zephyr Technology Ltd BioHarness Physiological Monitoring Device complies with 47 CFR Part 15 Subpart B as an Unintentional Radiator, as detailed below, when the methods as described in ANSI 63.4 - 2003 are applied. 4. TEST SAMPLE DESCRIPTION The Zephyr BioHarness™ product provides bio telemetry data of human vital signs over time. The bio telemetry data includes measurements such as heart rate, breathing rate, body temperature, posture and activity levels. The system consists of an electronic transmitting module that snaps onto a garment strap, a receiver module that plugs into a USB port on a computer and application software. In normal operation, a user wears the strap on his or her torso during physical activity and either transmits data to a PC via the USB receiver or logs data using the electronic module’s internal memory. Logged data may be uploaded using a USB cradle. The USB cradle is also used to charge the internal polymer lithium ion battery. Clause Parameter Result 15.101 Equipment authorisation requirement. Certification or Declaration of Conformity required for receivers. 15.103 Exempted devices. Not applicable as the device is a receiver and is not a digital device. 15.107 Conducted limits Complies. 15.109 Radiated emission limits Complies. 15.111 Antenna power conduction limit for receivers. Not applicable. The antenna is permanently attached to the receiver. EMC Technologies (NZ) Ltd Test Report No 80137.2 Report date: 30 January 2008 EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 5 of 14 This report may not be reproduced except in full 5. ATTESTATION This report describes the tests and measurements performed for the purpose of determining compliance with the specification with the following conditions: The client selected the test sample. The report relates only to the sample tested. This report does not contain corrections or erasures. Measurement uncertainties with statistical confidence intervals of 95% are shown below test results. Both Class A and Class B uncertainties have been accounted for, as well as influence uncertainties where appropriate. In addition this equipment has been tested in accordance with the requirements contained in the appropriate Commission regulations. To the best of my knowledge, these tests were performed using measurement procedures that are consistent with industry or Commission standards and demonstrate that the equipment complies with the appropriate standards. I further certify that the necessary measurements were made by EMC Technologies NZ Ltd, 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand. Andrew Cutler General Manager EMC Technologies NZ Ltd EMC Technologies (NZ) Ltd Test Report No 80137.2 Report date: 30 January 2008 EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 6 of 14 This report may not be reproduced except in full 6. TEST RESULTS Legislation The limits contained within 47 CFR Part 15 Subp…

Text truncated - open the document above for the full version.

Test Setup Photos

EMC Technologies (NZ) Ltd Test Report No 80137.2 Report date: 30 January 2008 EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 12 of 14 This report may not be reproduced except in full Conducted Emissions Test Set Up Photos EMC Technologies (NZ) Ltd Test Report No 80137.2 Report date: 30 January 2008 EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 13 of 14 This report may not be reproduced except in full Radiated emissions test set up EMC Technologies (NZ) Ltd Test Report No 80137.2 Report date: 30 January 2008 EMC Technologies (NZ) Ltd Telephone: +64 9 360 0862 Fax: +64 9 360 0861 STREET ADDRESS - 47 MacKelvie Street, Grey Lynn, Auckland, New Zealand E-mail: [email protected] POSTAL ADDRESS - PO Box 68 307, Newton, Auckland, New Zealand Web Site: www.emctech.com.au Page 14 of 14 This report may not be reproduced except in full

Contact Information

Applicant

Sailor Mohler
[email protected](443)569-3603Fax: (443)569-9402

Test Firm

EMC Technologies NZ Ltd.Andrew Cutler
[email protected]64-9-360-0862Fax: 64-9-360-0861

Technical Specifications

#Rule PartsFrequency RangePower Output
115B902.2 MHz - 927.8 MHz-
Confidentiality
Long Term