Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Oct 27, 2020
Application Purpose
Original Equipment
Date of Application
Oct 27, 2020
Equipment Note
Electronic Furniture Lock
Frequency Range
13.56000000 - 13.56000000
Company
Martin Lehmann GmbH & Co.KG
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Content Page General Description / Technical Specifications / Safety Precautions .......................................2 Care and Maintenance / Factory Settings / Functional Description .........................................3 Overview of Transponder Cards ..............................................................................................4 System Components and Package Contents ...........................................................................5 Dimensions...............................................................................................................................6 Mounting on non-metal surfaces ............................................................................................ 7 Mounting on metal surfaces ...................................................................................................9 Getting started and battery change / Tips for programming steps .......................................10 Using the installation card / Programming the Master card ..................................................11 Programming the Master card / Closing and Opening ..........................................................12 Unauthorised Transponders cards / Facility Manager Function / Emergency Opening .........13 Deleting Individual Transponder Cards / Deleting All Transponder Cards .............................14 Changing Operating Mode .....................................................................................................15 Deactivating and activating acoustic signals / Resetting to factory settings ..........................16 Activation and deactivation of automatic locking ..................................................................17 Battery warning .....................................................................................................................18 Reordering master cards / Firmware update / Disposal / Troubleshooting ...........................19 www.lehmann-locks.com Operating instructions GB Captura (Captura 100 MIFARE®) BDA Captura 100 MIFARE® / 2020-10-26 (GB) BDA Captura 100 MIFARE® / 2020-10-26 (GB) 2 GENERAL DESCRIPTION The Captura 100 MIFARE® lock is a battery-operated electronic furniture lock based on RFID technology, which is intended for use in living and office areas inside buildings. These operating instructions provide you with information on how to operate the locking system without errors. Keep the operating instructions in an easily accessible place. Improper use can destroy the locking system and lead to the loss of any warranty claims. Please be sure to observe all warnings and read the operating instructions completely before proceeding with installation, commissioning and programming. It may be possible to use our locks and locking systems together with mechanisms made by other manufacturers, but their compatibility must be checked in each individual case. We cannot accept any liability for damage or loss due to incompatibility. Wording and graphics have been prepared with care. However, no liability will be assumed for any mistakes that may have occurred. Technical specifications as well as the scope of items in the system are subject to change without notice. CAUTION: The lock can be configured with master and programming cards or with the LEHMANN Management Software LMS. These operating instructions describe how to use the locking system with master and programming cards. The software LMS and the corresponding documents can be found at https:// lms.lehmann-locks.com. SAFETY PRECAUTIONS UUPack the battery for the transport of the lock so that no short circuit can occur (risk of explosion and fire). UUWhen replacing the battery, make sure that the polarity and position of the battery is correct! UUDispose of used batteries properly! UUDo not heat batteries, take them apart or short-circuit them! UUNever throw batteries into open fire! ! TECHNICAL SPECIFICATIONS Frequency 13,56 MHz National legislation about permissible radio frequencies must be observed. RFID technology MIFARE® Classic, MIFARE® DESFire® EV1, EV2 Supported transponders Compatible with the following RFID transponders: • MIFARE® Classic / • MIFARE® DESFire® / • ISO 14443A Existing transponders must be checked for compatibility! Energy supply 1 x CR123A Operating temperature -5 °C to +60 °C Storage temperature -25 °C to +70 °C Reading distance Up to 30 mm with LEHMANN user cards (MIFARE® DESFire® EV1). Other transponders may have a shorter reading distance and must be checked in advance. The material of the furniture can influence the reading distance. A test on the furniture regarding the reading distance is therefore recommended. Type designation L3NF13CX BDA Captura 100 MIFARE® / 2020-10-26 (GB) 3 FACTORY SETTINGS The lock can be closed and opened at this point of time with one or more installation cards. After a Master card has been programmed, the lock is in the operating mode “assigned use“ and the installation card cannot be used any more. CARE AND MAINTENANCE UUDo not spill any liquid over or into the individual components of the lock, and never immerse the components in any liquid. UUThe product should not be exposed to direct sunlight. UUClean the lock and the components with a clean, soft, damp cloth only. UUDo not use any cleaning agents containing abrasives or solvents, as these may damage the housing. UUTreating any of the electronic and mechanical components improperly or in any way other than described in these operating instructions may lead to malfunctions and the loss of warranty. UUChange the battery in good time. At the latest, when the lock issues corresponding battery warnings. FUNCTIONAL DESCRIPTION With the Captura 100 MIFARE® lock, you can conveniently lock and unlock your furniture. Non-contact RFID techno- logy based on 13.56 MHz is used as the “key“. Two operating modes are available: Operating modeDescription Assigned use There is a fixed assignment between the transponder car…

Text truncated - open the document above for the full version.

Cover Letter(s)

Long/Short-term Confidentiality Request Federal Communications Commission Date: 13 October 2020 445 12 th SW, Washington D.C. USA FCC ID: W2YL3NF13CX To Whom it may concerns, Pursuant to sections 0.457(d) and 0.459 of CFR 47 and to avoid premature release of sensitive information prior to marketing or release of the product to the public, we hereby requests long-term confidential treatment of information accompanying this application as outlined below: ☒ Schematics ☒ Parts List ☒ Block Diagram ☐ Tune-Up Info ☒ Operational Description In addition we hereby request the following exhibits contained in this application to be temporarily (short-term confidentilality) withheld from the public disclosure ☐ for an initial period of days ☐ until: ☒ not applicable ☐ External Photos ☐ Test Setup Photos ☐ Internal Photos ☐ Users Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457(d), disclosure of this application and all accompanying documentation will not be made before the date of the GRANT for this application. If you have any questions, please feel free to contact me. Yours sincerely, Sabrina Berghahn Authorized Agent

External Photos

Annex BEUT external photos Examiner:Michael DinterTest Report No.: F201474E1 Date of issue: 02.10.2020Order No.:20-111474page 1 of 7 201474_eut01: Front view EUT in Setup B 201474_eut02: Rear view EUT in Setup B Annex BEUT external photos Examiner:Michael DinterTest Report No.: F201474E1 Date of issue: 02.10.2020Order No.:20-111474page 2 of 7 201474_eut03: Front plate EUT in Setup B 201474_eut04: EUT in Setup B with TAG Annex BEUT external photos Examiner:Michael DinterTest Report No.: F201474E1 Date of issue: 02.10.2020Order No.:20-111474page 3 of 7 201474_eut05: Front view EUT in Setup A 201474_eut06: Rear view EUT in Setup A Annex BEUT external photos Examiner:Michael DinterTest Report No.: F201474E1 Date of issue: 02.10.2020Order No.:20-111474page 4 of 7 201474_eut07: EUT in Setup A with TAG 201474_eut08: Used TAG for setup A Annex BEUT external photos Examiner:Michael DinterTest Report No.: F201474E1 Date of issue: 02.10.2020Order No.:20-111474page 5 of 7 201474_eut09: Used TAG for setup B 201474_eut10: EUT 3D view 1 Annex BEUT external photos Examiner:Michael DinterTest Report No.: F201474E1 Date of issue: 02.10.2020Order No.:20-111474page 6 of 7 201474_eut11: EUT 3D view 2 201474_eut12: EUT 3D view with battery cover Annex BEUT external photos Examiner:Michael DinterTest Report No.: F201474E1 Date of issue: 02.10.2020Order No.:20-111474page 7 of 7 201474_eut13: EUT rear view with battery

ID Label/Location Info

Label on, Captura 100 Mifare / L3NF13CX (20 x 20 mm²) Part of injection moulded enclosure: Captura 100 MIFARE Type L3NF13CX 3V, 1100 mA, 13.56 MHz FCC ID: W2YL3NF13CX IC: 8141A-L3NF13CX SN: YY-WW123

Internal Photos

Annex CEUT internal photos Examiner:Michael DinterTest Report No.: F201474E1 Date of issue: 05.10.2020Order No.:20-111474page 1 of 3 201474_pcb01: EUT inside view 1 201474_pcb02: EUT inside view 2 Annex CEUT internal photos Examiner:Michael DinterTest Report No.: F201474E1 Date of issue: 05.10.2020Order No.:20-111474page 2 of 3 201474_pcb03: EUT inside view 3 201474_pcb04: PCB bottom view Annex CEUT internal photos Examiner:Michael DinterTest Report No.: F201474E1 Date of issue: 05.10.2020Order No.:20-111474page 3 of 3 201474_pcb05: PCB top view

Test Report

Königswinkel 10 32825 Blomberg, Germany Phone: +49 (0) 52 35 / 95 00-0 Fax:+49 (0) 52 35 / 95 00-10 [email protected] www.phoenix-testlab.de Test Report Report Number: F201474E1 Equipment under Test (EUT): Captura 100 MIFARE Applicant: Martin Lehmann GmbH & Co. KG Manufacturer: Martin Lehmann GmbH & Co. KG Examiner:Michael DINTERReport Number: F201474E1 Date of Issue: 02.10.2020Order Number: 20-111474Page 2 of 21 References [1] ANSI C63.10: 2013 American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices [2] FCC CFR 47 Part 15 Radio Frequency Devices [3] RSS-210 Issue 10 (December 2019) Licence-exempt Radio Apparatus (All Frequency Bands): Category I Equipment [4] RSS-Gen Issue 5 (March 2019)Amendment 1 General Requirements for Compliance of Radio Apparatus Test Result The requirements of the tests performed as shown in the overview (clause 4) were fulfilled by the equipment under test. The complete test results are presented in the following. This test report is only valid in its original form. Any reproduction of its contents in extracts without written permission of the accredited test laboratory PHOENIX TESTLAB GmbH is prohibited. The test results herein refer only to the tested sample. PHOENIX TESTLAB GmbH is not responsible for any generalisations or conclusions drawn from these test results concerning further samples. Any modification of the tested samples is prohibited and leads to the invalidity of this test report. Each page necessarily contains the PHOENIX TESTLAB Logo and the TEST REPORT NUMBER. Tested and written by:Michael DINTER02.10.2020 NameSignatureDate Reviewed and approved by:Manuel BASTERT02.10.2020 Name Signature Date Examiner:Michael DINTERReport Number: F201474E1 Date of Issue: 02.10.2020Order Number: 20-111474Page 3 of 21 Contents:Page Identification ................................................................................................................................. 4 1.1Applicant ................................................................................................................................................... 4 1.2Manufacturer ............................................................................................................................................ 4 1.3Test Laboratory ........................................................................................................................................ 4 1.4EUT (Equipment under Test) ................................................................................................................... 5 1.5Technical Data of Equipment ................................................................................................................... 6 1.6Dates ........................................................................................................................................................ 6 Operational States ........................................................................................................................ 7 Additional Information ................................................................................................................... 7 Overview ....................................................................................................................................... 8 Results.......................................................................................................................................... 9 5.1Radiated emissions .................................................................................................................................. 9 5.1.1Test method ..................................................................................................................................... 9 5.1.2Results preliminary measurement 9 kHz to 30 MHz ..................................................................... 14 5.1.3Result final measurement from 9 kHz to 30 MHz .......................................................................... 15 5.1.4Result final measurement from 30 MHz to 1 GHz ......................................................................... 16 5.299 % bandwidth ...................................................................................................................................... 18 5.2.1Test method ................................................................................................................................... 18 5.2.2Test results .................................................................................................................................... 19 Test Equipment used for Tests ................................................................................................... 20 Test site Validation ..................................................................................................................... 21 Report History ............................................................................................................................. 21 List of Annexes ........................................................................................................................... 21 Examiner:Michael DINTERReport Number: F201474E1 Date of Issue: 02.10.2020Order Number: 20-111474Page 4 of 21 Identification 1.1 Applicant Name:Martin Lehmann GmbH & Co. KG Address:Am Kohlgraben 6 - 10, 32429 Minden Country:Germany Name for contact purposes:Mr. Guido JÄGER Phone:+49 (0)571 50531-31 eMail address:[email protected] Applicant represented during the test by the following person: Mr. Guido JÄGER (some parts of the test) 1.2 Manufacturer Name:Martin Lehmann GmbH & Co. KG Address:Am Kohlgraben 6 - 10, 32429 Minden Country:Germany Name for contact purposes:Mr. Guido JÄGER Phone:+49 (0)571 50531-31 eMail address:[email protected] Manufacturer represented during the test by the following person: Mr. Guido JÄGER (some parts of the test) 1.3 Test Laboratory The…

Text truncated - open the document above for the full version.

Test Setup Photos

Annex ATest setup photos Examiner:Michael DINTERReport Number: F201474E1 Date of Issue: 02.10.2020Order Number: 20-111474Page 1 of 3 201474_01: Setup EUT 201474_02: Preliminary measurement 9 kHz - 30 MHz Annex ATest setup photos Examiner:Michael DINTERReport Number: F201474E1 Date of Issue: 02.10.2020Order Number: 20-111474Page 2 of 3 201474_03: Final measurement 9 kHZ - 30 MHz 201474_04: Final measurement 30 - 1000 MHz Annex ATest setup photos Examiner:Michael DINTERReport Number: F201474E1 Date of Issue: 02.10.2020Order Number: 20-111474Page 3 of 3 201474_05: Final measurement 30 - 1000 MHz

Contact Information

Applicant

Soenke Schlueter
[email protected]004957150599Fax: 00495715999

Test Firm

PHOENIX TESTLAB GmbHHolger Bentje
[email protected]49-5235-9500-24Fax: 49-5235-9500-28

Technical Specifications

#Rule PartsFrequency RangePower OutputTolerance
115C13.56 MHz - 13.56 MHz-0.0100000000 %
Confidentiality
Long Term

Other Applications from Martin Lehmann GmbH & Co.KG

W2Y-MSI2CPM7

Electronic furniture lock

Nov 18, 2025

Equipment Class

JAB - Part 15 Class B Digital Device
Electronic Furniture Lock - FCC ID W2Y-SLI2CPM6 - Martin Lehmann GmbH & Co.KG
W2Y-SLI2CPM6

Electronic Furniture Lock

May 05, 2024

Equipment Class

JAB - Part 15 Class B Digital Device