Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
CSA Group Bayern GmbH File No. T38149-00-00HS, page 3 of 11 Ohmstrasse 2-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 3.0 2014-01-30 1 P h o t o d o c u m e n t a t i o n o f t h e E U T 1.1 External views: Front view Rear view
CSA Group Bayern GmbH File No. T38149-00-00HS, page 3 of 11 Ohmstrasse 2-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 3.0 2014-01-30 1 P h o t o d o c u m e n t a t i o n o f t h e E U T 1.1 External views: Front view Rear view
Date: 01.07.2014 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: FCC ID: W34UMRR0A and FCC W34UMRR0A20X Applicant: SMS Smart Microwave Sensors Dear Examiner, Our client SMS Smart Micro Sensors is seeking approvals for the above mentioned FCC IDs! The DoC logo appears on the label due to recommendations from their previous TCB. As the TCB ACB has indicated that the logo is incorrect on those labels, please accept this declaration that the applicant SMS Smart Microwave Sensors will remove the logo from their label for future projects. It is not possible to get a revised label in time to satisfy this application. Hopefully this DoC administrative mistake does not affect the certification of the transmitters with the above mentioned FCC IDs! If you have any questions regarding this application, please feel free to contact me. Sincerely, Mr. Thomas Ring GMA – Teamlead CSA Group Bayern GmbH Ohmstrasse 1-4 94342 Strasskirchen Germany Phone: 0049 9424 9481 250 Fax: 0049 9424 9481 240
FCC ID: W34UMRR0A20X CSA Group Bayern GmbH File No. T38149-00-00HS, page 1 of 44 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.:+49(0)9424-94810 Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 EMI − T E S T R E P O R T - FCC Part 15.249, RSS310 - Test Report No. : T38149-00-00HS 23. June 2014 ______________________________________________________________________________________________ Date of issue Type / Model Name : UMRR-0Axxxx-20xxxx-07xxxx Product Description : Field disturbance sensor Applicant : s.m.s. smart microwave sensors GmbH Address : In den Waashainen 1 38108 BRAUNSCHWEIG, GERMANY Manufacturer : s.m.s. smart microwave sensors GmbH Address : In den Waashainen 1 38108 BRAUNSCHWEIG, GERMANY Licence holder : s.m.s. smart microwave sensors GmbH Address : In den Waashainen 1 38108 BRAUNSCHWEIG, GERMANY Test Result according to the standards listed in clause 1 test standards: POSITIVE The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permission of the test laboratory. FCC ID: W34UMRR0A20X CSA Group Bayern GmbH File No. T38149-00-00HS, page 2 of 44 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.:+49(0)9424-94810 Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 Contents 1 T E S T S T A N D A R D S 3 2 S U M M A R Y 4 2.1 GENERAL REMARKS: 4 2.2 Test result summery 5 2.3 FINAL ASSESSMENT: 5 3 E Q U I P M E N T U N D E R T E S T 6 3.1 Photo documentation of the EUT – Please see attachment A 6 3.2 Power supply system utilised 6 3.3 Short description of the equipment under test (EUT) 6 4 T E S T E N V I R O N M E N T 7 4.1 Address of the test laboratory 7 4.2 Environmental conditions 7 4.3 Statement of the measurement uncertainty 7 4.4 Measurement protocol for FCC and IC 8 4.5 Determination of worst case measurement conditions 9 5 T E S T C O N D I T I O N S A N D R E S U L T S 10 5.1 AC power line conducted emissions 10 5.2 Field strength of fundamental 13 5.3 Out-of-band emission, radiated 15 5.4 EBW 40 5.6 Antenna application 43 6 U S E D T E S T E Q U I P M E N T A N D A C C E S S O R I E S 44 A t t a c h m e n t A a s s e p e r a tel y s u p p l e m e n t FCC ID: W34UMRR0A20X CSA Group Bayern GmbH File No. T38149-00-00HS, page 3 of 44 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.:+49(0)9424-94810 Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules and Regulations Part 15, Subpart A - General (September, 2013) Part 15, Subpart A, Section 15.31 Measurement standards Part 15, Subpart A, Section 15.33 Frequency range of radiated measurements Part 15, Subpart A, Section 15.35 Measurement detector functions and bandwidths FCC Rules and Regulations Part 15, Subpart C - Intentional Radiators (September, 2013) Part 15, Subpart C, Section 15.203 Antenna requirement Part 15, Subpart C, Section 15.204 External radio frequency power amplifiers and antenna modifications Part 15, Subpart C, Section 15.205 Restricted bands of operation Part 15, Subpart C, Section 15.207 Conducted limits Part 15, Subpart C, Section 15.209 Radiated emission limits, general requirements Part 15, Subpart C, Section 15.249 Operation within the bands 902 - 928 MHz, 2400 – 2483.5 MHz, 5725 - 5875 MHz and 24.0 – 24.25 GHz ANSI C63.4: 2009 Methods of Measurement of Radio-Noise Emissions from Low- Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. ANSI C95.1:2005 IEEE Standard for Safety Levels with respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz CISPR 16-4-2: 2003 Uncertainty in EMC measurement CISPR 22: 2005 Information technology equipment EN 55022: 2006 FCC ID: W34UMRR0A20X CSA Group Bayern GmbH File No. T38149-00-00HS, page 4 of 44 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.:+49(0)9424-94810 Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 2 S U M M A R Y 2.1 GENERAL REMARKS: The EUT is a field disturbance sensor with frequency emissions in 19 settable ranges the operating band of 24000 MHz to 24250 MHz. Variants of the EUT Antennas The following integrated antennas are used with the EUT: - Integrated linear polarised mocro strip patch array antenna. The antennas cannot be unattached by the user. Operation frequency and channel plan The operating frequency is 24.0 GHz to 24.25 GHz. Note. The marked frequencies are determined for testing. Transmit operating modes As soon as the equipment is powered on, TX starts operating independent of a possible connected PC. For TX continuous no special test software is needed. Frequency rangeCentre frequency (MHz) 024010 124022.5 224035 324047.5 424060 524072.5 624085 724097.5 824110 924122.5 1024135 1124147.5 1224160 1324172.5 1424185 1524197.5 1624210 1724222.5 1824235 Note: the marked frquencies are determined for testing. FCC ID: W34UMRR0A20X CSA Group Bayern GmbH File No. T38149-00-00HS, page 5 of 44 Ohmstrasse 1-4 94342 STRASSKIRCHEN GERMANY Tel.:+49(0)9424-94810 Fax:+49(0)9424-9481440 Rev. No. 3.0, 2014-01-30 2.2 Test result summery Operating in the 24000 MHz – 24250 MHz band: 2.3 FINAL ASSESSMENT: The equipment under test fulfills the EMI requirements cited in clause 1 test standards. Date of receipt of test sample : acc. to storage records Testing commenced on : 28 April 2014 Testing concluded on : 21 May 2014 Checked by: Tested by: Klaus Gegenfurtner Teamleader Radio Hermann Smetana Radio Team FCC Rule PartRSS Rule PartDescriptionResult 15.203RSS-Gen, 7.1.2Antenna requirementpassed 15.204RSS-Gen, 7.1.1External radio frequency power amplifierspassed 15.205(a) RSS Gen, 7.2.2 Emissions in restricted bandspassed 15.207(a) RSS Gen, 7.2.4 AC power line conducted emissionspassed 15.209(a)RSS-Gen, 7.2.2Radiated emission limits; general passed 15.215(c)RSS-Gen, 4.6.1EBWpassed 15.249(a)RSS-310, 3.10Field strength of fundamentalpassed 15.249(d)RSS-310, 3.10Out-of-band emission, radiatedpassed 15.249(a)RSS-310, 3.1…
Text truncated - open the document above for the full version.
CSA Group Bayern GmbH File No. T38149-00-00HS, page 7 of 11 Ohmstrasse 2-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 3.0 2014-01-30 2 T e s t s e t - u p p h o t o g r a p h s 2.1 AC power line conducted emissions A 4 2.2 Field strength of fundamental CPR 3 CSA Group Bayern GmbH File No. T38149-00-00HS, page 8 of 11 Ohmstrasse 2-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 3.0 2014-01-30 2.3 Out-of-band emission, radiated SER1 Test setup 9 kHz – 30 MHz: SER 2 Test setup 30 MHz – 1000 MHz: CSA Group Bayern GmbH File No. T38149-00-00HS, page 9 of 11 Ohmstrasse 2-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 3.0 2014-01-30 SER 3 Test setup 1 GHz – 18 GHz: CSA Group Bayern GmbH File No. T38149-00-00HS, page 10 of 11 Ohmstrasse 2-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 3.0 2014-01-30 Test setup 18 GHz – 40 GHz: Test setup 40 GHz – 100 GHz: CSA Group Bayern GmbH File No. T38149-00-00HS, page 11 of 11 Ohmstrasse 2-4 94342 STRASSKIRCHEN GERMANY Tel.: +49(0)9424-94810 Fax: +49(0)9424-9481440 Rev. No. 3.0 2014-01-30 2.4 EBW MB
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 24.01 GHz - 24.23 GHz | - |

UMRR-12 Type 48 B
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Automotive radar sensor DRVEGRD 169
Equipment Class
VRD - Part 95 Vehicular Radar Systems
TRUGRD Stream
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
UMRR-12 Type 48
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
UMRR-12 Type 48
Equipment Class
FDS - Part 15 Field Disturbance Sensor