FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. sms smart microwave sensors GmbH/
  3. W34UMRR0C27X

W34UMRR0C27XField Disturbance Sensor

sms smart microwave sensors GmbH
Field Disturbance Sensor - FCC ID W34UMRR0C27X - sms smart microwave sensors GmbH
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
May 20, 2015
Application Purpose
Original Equipment
Date of Application
May 18, 2015
Equipment Note
Field Disturbance Sensor
Frequency Range
24005.60000000 - 24195.20000000
Company
sms smart microwave sensors GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex acc. to FCC Title 47 CFR Part 15 relating to s.m.s. smart microwave sensors GmbH UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 Annex no. 5 User Manual Functional Description Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators Measurement Procedure: ANSI C63.4-2009 Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 User Manual / Functional Description of the test equipment (EUT) Sensor description: The main task of the UMRR is the detection of any reflectors in the field of view, to measure the distance, the relative speed and the angle to the shortest reflector (and to other reflectors), to detect motion and to track (filter) the results over time. For this general purpose measurement application, range and relative radial speed and the angle value of each reflector inside the antenna beam are measured and the results are reported via the communication links cycle by cycle. Transmit Signal: The UMRR transmit frequency is located in the 24 GHz ISM band (24000 MHz to 24250 MHz), the used bandwidth is smaller than 250 MHz. The maximum transmit power is 12.7dBm. Antenna type 39 is used, consisting of one transmit and twelve receive antennas, both linear polarized. The 2 way 3 dB cut-off angle in az. +-28deg. and in el. +-5deg. The antenna has two main lobes. The greater main lobe is at +17°, counting clockwise, the second at -20°. Designated use: The device uses different FMCW transmit signal waveforms for distance and speed measurement. The UMRR general purpose medium range radar is suitable for any application where the distance to and relative radial speed of large objects has to be measured. Typical applications are:  Automotive: measure shortest distance to obstacle.  Robotics: measure shortest distance to obstacle.  Security: detect motions and measure distance to moving object.  Traffic management: detect moving objects, count those, measure speed and measure distance to moving object.  Cranes: measure distance to ground.  Aircraft: measure distance to ground.  The detection range depends on object size. Very large reflectors can be detected at a range of more than 500 m. Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Declaration of Conformity for USA: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Usually this is followed by the following FCC caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may case harmful interferences to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more following measures: - Reorient or relocate the receiving antenna - Increase the separation between the equipment and receiver - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected - Consult the dealer or an experienced radio/TV technician for help. Declaration of Conformity for CANADA: Declaration of Conformity in English: This device complies with RSS-310 of Industry Canada. Operation is subject to the condition that this device does not cause harmful interference. Déclaration de conformité en francais: Cet appareil est conforme au CNR-310 d'Industrie Canada. Son exploitation est autorisée sous réserve que l'appareil ne cause pas de brouillage préjudiciable. Declaration of Conformity for EUROPE: The UMRR-0C0103-272301-070704 has been marked with the CE mark. This mark indicates the compliance with the EC Directive 1999/5/EC. A full copy of the Declaration of Conformity can be obtained from s.m.s, smart microwave sensors GmbH, 38108 Braunschweig, Germany or via E-Mail. Please contact us at [email protected].

Cover Letter(s)

smartmicro SMS,SMART MICROv'vAVE SENSORS GMBH S.m.s, smart microwave sensors GmbH . In den Waashainen 1 . 38108 Braunschweig . Germany Subject: Request for confidentiality FCC ID: W34UMRR(X27X DearFCCTCB, Persuant to 47 CFR Section 0.459(a) & (b), s.m.s smart microwave sensors GmbH hereby requests non-disciosure and confidential treatment of the following materials submitted in support of FCC certification application for FCC ID: W34UMRR0a7X IE! Blll(s) of Material El Block Diagrams E Operational Description E Schematlc Diagrams El Internal Photos Above materials contain secrets, proprietary and technical Information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disciosure or publication or any portion of this Company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. s.m.s, smart microwave sensors GmbH understands that pursuant to 47 CFR section 0.457(d)(l)(ii) disciosure of the applicant and all accompanying documentation will not be made before the date of the grant. Office Address; In den Waashainen 1 38106 ßraunschweig, Germany Phone: +49 (0) 531-39023-0 Fax: +49 (0) 531-39023-599 www.smaitmlcro.de Managing Director: Dr.-Ing. Ralph Mende Register Court Braunschweig HRB 4525 February 25, 2015, Braunschweig, Germany Dr.-Ing. Ralph Mende confidentiality..FCC_W34UMRR0C27X.docx February 25, 2015 Bank Account: HypoVereinsbank Braunschweig, Germany Bank Number: 200 300 00 Account Number: 725 9153 IBAN: DE95 2003 0000 0007 2591 53 Swift (BIG): HYVEDEMM300 VAT ID: DE193324798 Tax Number: FA 13/207/02357

Cover Letter(s)

# smartmicro ^ SMS.SMART MICROWAVE SENSORS GMBH S.m.s. smart microwave sensors GmbH . In den Waashainen . 38108 Braunschweig . Germany To whom it may concern We hereby declare that we will follow the DoC route for the fbliowing equipment: Equipment: Field Disturbance Sensor Trademark(s): smartmicro Model(s): UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 Manufacturer: s.m.s, smart microwave sensors GmbH i=CC ID in case other parts of this equipment are subject to certification: W34UMRR0C27X Yours sincerely, / Dr. Ralph Mende, Managing Director, s.m.s, smart microwave sensors GmbH Office Address: In den Waashainen 1 38106 Braunschweig, Germany Phone: +49 (0) 531-39023-0 Fax: +49 (0) 531-39023-599 www.smartniicro.de Managing Director: Dr.-Ing. Ralph Mende Register Court Braunschweig HRB 4525 Bank Account: HypoVereinsbank Braunschweig, Germany Bank Number: 200 300 00 Account Number: 725 9153 IBAN: DE95 2003 0000 0007 2591 53 Swift (BJC): HYVEDEMM300 VAX ID: DE193324798 FCC DoC Route_UMRR-0C0103-2723Ql-070704.docx Februar/ 25,2015 Tax Number: FA 13/207/02357

Cover Letter(s)

- smartmicro SMS.SMART MICROWAVE SENSORS GMBH s.m.s. smart microwave sensors GmbH . In den Waashainen . 38108 Braunschweig . Germany Federal Commmiications Commission 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: This letter is to comply with Sections 0.457 and 0.459 pertaining to confidential material. Smart microwave sensors GmbH would like the internal photos regarding this Submission for FCC ID: W34UMRR0C27X to be kept confidential. The photos contain trade secrets or technical data, which would customarily be guarded from competitors. Specific to this design is the antenna design where considerable design effort and IP (i.e. number and type of antennas) is contained. A photo of the antenna or the antenna distribution network located on the backside of the antenna board is enough to allow a competitor reverse engineer our design and thus impact our competitive advantage. For these reasons these photos should not be accessible to the general public. Furthermore, the device is serviceable only by a smart microwave sensors GmbH designated technician. Yours sincerely, February 25, 2015, Dr. Ralph Mende, Managing Director, s.m.s, smart microwave sensors GmbH Office Address: In den Waashainen 1 38106 Braunschweig, Germany Phone: +49 (0) 531-39023-0 Fax: +49 (0) 531-39023-599 www.smartinlcro.de Managing Director: Dr.-Ing. Ralph Mende Register Court Braunschweig HRB 4525 Bank Account: HypoVereinsbank Braunschweig, Germany Bank Number: 200 300 00 Account Number: 725 9153 FCC_conndentiaLW34UMRR0C27X.docx February 25, 2015 IBAN: DE95 2003 0000 0007 2591 53 Swift (BIG): HYVEDEMM300 VAX ID: DE193324798 Tax Number: FA 13/207/02357

Cover Letter(s)

% smartmicro SMS,SMART MiCROVVAVE SENSORS GMBH sms.smart microwave sensors GmbH . In den Waashainen . 38108 Braunschweig . Germany Power of Attorney Name or model type of the Specified Radio Equipment: UMRR-0C0103-272301-070704 UMRRKXX)104-272301-070704 Appiicanfs Company name: Applicanfs Company address: Appiicanfs name: s.m.s, smart microwave sensors GmbH In den Waashainen 1 38108 Braunschweig/Germany Dr. Ralph Mende Date and Appiicanfs Signatare: February 25, 2015, Job Title and Department: Managing Director / Itisne(xssary,th^ the person legistBedvOht FCC, ägnsthisform. CiL I hereby authorize the following person as a representative and all rights regarding the application to obtain Type Certification for the Specified Radio Equipment (mentioned above) are delegated. Attome/s Company name: Attome/s Company address: Attome/s Name: m. dudde hochfrequenz-technik Rottland 5a 51429 Bergisch Gladbach/Germany Mrs. Anja Hittig-Rademacher Date and Attorne/s Signatare: Job Title and Department: homologation depaitment., Power of Attorney UMRR^0C0103-272301-070704.docx February 25, 2015 Office Address; In den Waashainen 1 38106 Braunschweig, Germany Phone; +49 (0) 531-39023-0 Fax: +49 (0) 531-39023-599 www.smartmicro.de Managing Director: Dr.-Ing. Ralph Mende Register Court Braunschweig HRB 4525 Bank Account: HypoVereinsbank Braunschweig, Germany Bank Number: 200 300 00 Account Number: 725 9153 IBAN: DE95 2003 0000 0007 2591 53 Swift (SIC): HYVEDEMM300 VAX ID: DE193324798 Tax Number: FA 13/207/02357

External Photos

Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex acc. to FCC Title 47 CFR Part 15 relating to s.m.s. smart microwave sensors GmbH UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 Annex no. 1 External Photographs Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators Measurement Procedure: ANSI C63.4-2009 Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photographs of the test equipment (EUT) – Assembly of Units Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photographs of the test equipment (EUT) – Upper side of unit Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photographs of the test equipment (EUT) – Lower side of unit Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photographs of the test equipment (EUT) – Lower side of unit Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photographs of the test equipment (EUT) – Horizontal side-1 of unit Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photographs of the test equipment (EUT) – Horizontal side-2 of unit Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photographs of the test equipment (EUT) – Top side of unit Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photographs of the test equipment (EUT) – Bottom side of unit

ID Label/Location Info

Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex acc. to FCC Title 47 CFR Part 15 relating to s.m.s. smart microwave sensors GmbH UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 Annex no. 4 Label Sample Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators Measurement Procedure: ANSI C63.4-2009 Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photo of the test equipment (EUT) – Label Sample Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photo of the test equipment (EUT) – Label Location Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photo of the test equipment (EUT) – Label Location

Test Report

Test report no. 15009837 Page 1 of 34 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-11 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Test Report acc. to FCC Title 47 CFR Part 15 relating to s.m.s. smart microwave sensors GmbH UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators Measurement Procedure: ANSI C63.4-2009 Test report no. 15009837 Page 2 of 34 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-11 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 MANUFACTURER Manufacturer name s.m.s., smart microwave sensors GmbH Manufacturer’s grantee code W34 Manufacturer’s address In den Waashainen 1, 38108, Braunschweig, Germany Phone +49 (0) 531 390 23 0 Fax +49 (0) 531 390 23 599 Email [email protected] TESTING LABORATORY Test engineer Mr. Ralf Trepper Testing laboratory name m. dudde hochfrequenz-technik Testing laboratory address Rottland 5a, 51429 Bergisch Gladbach, Germany Phone +49 2207 96890 Fax +49 2207 968920 Email [email protected] RELEVANT STANDARD Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart Subpart C – Intentional Radiators Measurement procedure ANSI C63.4-2009 EQUIPMENT UNDER TEST (EUT) Equipment category Field Disturbance Sensor / Non specific SRD Trade name smartmicro Type designation UMRR-0C0103-272301-070704 Serial no. --- Variants UMRR-0C0104-272301-070704 Test report no. 15009837 Page 3 of 34 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-11 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 1. Test results Clause Requirements headline Test result Page number 8.1 Antenna requirement Pass Fail N.t.* 9 8.2 Conducted limits Pass Fail N.t.* 10 - 12 8.3 Restricted bands of operation Pass Fail N.t.* 13 - 15 8.4 Radiated emission limits, general requirements Pass Fail N.t.* 165 - 20 8.5 Fundamental frequencies / Field strength limits Pass Fail N.t.* 21 - 25 8.6 Bandwidth Pass Fail N.t.* 26 * Not tested The equipment passed all the conducted tests Yes No Signature Name Mr. Ralf Trepper Mr. Manfried Dudde Designation Technician Laboratory-Manager Date of issue 2015-04-01 2015-04-01 Test report no. 15009837 Page 4 of 34 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-11 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Table of contents 1. Test results ........................................................................................................................................................ 3 2. Introduction ...................................................................................................................................................... 5 3. Testing laboratory ............................................................................................................................................ 5 4. Applicant .......................................................................................................................................................... 6 5. Product and product documentation ................................................................................................................ 6 6. Conclusions, observations and comments ....................................................................................................... 7 7. Operational description ..................................................................................................................................... 8 8. Compliance assessment .................................................................................................................................... 9 8.1 Antenna requirement ...................................................................................................................................... 9 8.1.2 Result .................................................................................................................................................... 9 8.2 Conducted limits ............................................................................................................................................ 10 8.2.1 Regulation ............................................................................................................................................. 10 8.2.2 Test procedures ..................................................................................................................................... 11 8.2.3 Result .................................................................................................................................................... 11 8.3 Restricted bands of operation .......................................................................................................................... 13 8.3.1 Regulation ............................................................................................................................................. 13 8.3.2 Result .................................................................................................................................................... 15 8.4 Radiated emission limits, general requirements ............................................................................................ 16 8.4.1 Regulation .......................................…

Text truncated - open the document above for the full version.

Test Report

Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex acc. to FCC Title 47 CFR Part 15 relating to s.m.s. smart microwave sensors GmbH UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 Annex no. 3 Occupied Bandwidth Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators Measurement Procedure: ANSI C63.4-2009 Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Plots for the test equipment (EUT) – Measured 20 dB Bandwidth : 188.09 MHz

Test Setup Photos

Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Annex acc. to FCC Title 47 CFR Part 15 relating to s.m.s. smart microwave sensors GmbH UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 Annex no. 6 Test Setup Photographs Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators Measurement Procedure: ANSI C63.4-2009 Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photo to the test: Conducted limits – with EUT+ Laptop* over LAN Port Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photo to the test: Restricted bands of operation / Radiated emission limits 30 MHz – 1 GHz Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photo to the test: Restricted bands of operation / Radiated emission limits 1 GHz – 15 GHz Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photo to the test: Restricted bands of operation / Radiated emission limits 15 GHz – 40 GHz Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photo to the test: Restricted bands of operation / Radiated emission limits 40 GHz – 60 GHz Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photo to the test: Restricted bands of operation / Radiated emission limits 60 GHz – 90 GHz Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photo to the test: Restricted bands of operation / Radiated emission limits 90 GHz – 140 GHz Reference Test report no. 15009837 EUT: UMRR-0C0103-272301-070704 UMRR-0C0104-272301-070704 FCC ID: W34UMRR0C27X FCC Title 47 CFR Part 15 C Date of issue: 2015-04-01 Date: 2015-03-13 Vers. no. 1.15 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 Photo to the test: Fundamental frequencies – Field strength limits

Contact Information

Applicant

Ralph Mende(Dr.)
[email protected]+49531390230Fax: +4953139023599

Technical Contact

s.m.s smart microwave sensors GmbHRalph Mende
[email protected]49531390230

In den Waashainen 1 · Germany

Non-Technical Contact

s.m.s smart microwave sensors GmbHRalph Mende
[email protected]49531390230

Test Firm

TUEV NORD Hochfrequenztechnik GmbH & Co. KGRalf Trepper
[email protected]+49 221 / 88889518Fax: +49 221 / 88889595

Technical Specifications

#Rule PartsFrequency RangePower Output
115C24.01 GHz - 24.20 GHz-
Confidentiality
Long Term

Other Applications from sms smart microwave sensors GmbH

UMRR-12 Type 48 B - FCC ID W34UMRR1230X2 - sms smart microwave sensors GmbH
W34UMRR1230X2

UMRR-12 Type 48 B

Aug 24, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Automotive radar sensor DRVEGRD 169 - FCC ID W34UMRR9FA9 - sms smart microwave sensors GmbH
W34UMRR9FA9

Automotive radar sensor DRVEGRD 169

Feb 26, 2023

Equipment Class

VRD - Part 95 Vehicular Radar Systems
TRUGRD Stream - FCC ID W34UMRR1230S - sms smart microwave sensors GmbH
W34UMRR1230S

TRUGRD Stream

Feb 09, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
UMRR-12 Type 48 - FCC ID W34UMRR1230X - sms smart microwave sensors GmbH
W34UMRR1230X

UMRR-12 Type 48

Nov 19, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
UMRR-12 Type 48 - FCC ID W34UMRR1230 - sms smart microwave sensors GmbH
W34UMRR1230

UMRR-12 Type 48

Oct 12, 2020

Equipment Class

FDS - Part 15 Field Disturbance Sensor