Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Dec 22, 2009
Application Purpose
Original Equipment
Date of Application
Dec 22, 2009
Equipment Note
Remote Control to open and close cupboard doors
Frequency Range
2403.00000000 - 2477.00000000
Company
Julius Blum GmbH
Country
Austria

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Schematics

↗
↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Installation leaflet – Original SERVO-DRIVE for AVENTOS AVENTOS HF AVENTOS HS AVENTOS HL 2 1 About these instructions Thank you for your purchase. SERVO-DRIVE for AVENTOS from Julius Blum GmbH is a high-quality product that simplifies everyday kitchen tasks. To better enjoy the comfort and safety of SERVO-DRIVE for AVENTOS, please note the following: ⇒ Carefully read the instruction leaflet before use. ⇒ Please retain the instruction leaflet for the service life of SERVO-DRIVE for AVENTOS. ⇒ Please pass on this instruction leaflet to each subsequent owner or user of SERVO-DRIVE for AVENTOS. Table of contents DANGER Danger: The DANGER sign indicates important safety information that must be followed. WARNING Warning: The WARNING sign indicates important warning information that must be followed. CAUTION Comment: The CAUTION sign indicates information that if not followed may lead to the pre- mature wear of SERVO-DRIVE for AVENTOS. NOTICE Note: The NOTE sign indicates information that should be followed. 1 About these instructions 2 Validity and target group 2 2 Safety 3 2.1 Principle 3 2.2 Safety information 3 2.3 Intended use 4 2.4 Structural changes and spare parts 4 2.5 Children 4 2.6 Wall cabinet care and cleaning 5 3 Description 6 4 Problems 10 5 Technical data 11 5.1 Power supply 11 5.2 Drive unit 11 5.3 Blum switch 11 6 Spare parts 11 7 Disposal 11 3 Validity and target group This instruction leaflet is intended for all users of lift systems in furniture equipped with SERVO-DRIVE for AVENTOS. Installation, set up, initial operation, maintenance and removal may only be carried out by qualified personnel according to the separate installation instructions. 2 Safety 2.1 Principle SERVO-DRIVE for AVENTOS complies with current safety standards. Nevertheless, there are certain risk factors if the information in this instruction leaflet is not followed. Please be aware that Julius Blum GmbH is not responsible for incidental or consequential damages that may arise due to non-compliance with this instruction leaflet. 2.2 Safety information ⇒ The mains plug and the Blum transformer must be easily accessible. ⇒ Neither the Blum transformer nor any cabling should come into contact with moving parts. ⇒ This device should not be used by persons (including children) with limited physical, sensory or mental abilities, or those with a lack of experience and/ or knowledge. Unless they are supervised by a person responsible for their safety or they receive instruction on how to operate the device. WARNING Danger of injury in the area of the lever. Touching the area around the lever during the opening and closing motion can cause injury. ⇒ Do not touch the area around the lever during the opening and closing motion. 4 2.4 Structural changes and replacement parts Structural changes and spare parts not approved by the manufacturer affect the safety and functionality of SERVO-DRIVE for AVENTOS and are, therefore, not allowed. ⇒ Only use original spare parts from Julius Blum GmbH. ⇒ Blum components are the only devices that should be connected to the Blum transformer. ⇒ Only qualified technicians may install/replace Blum components, modify the position of the Blum transformer or modify any cabling. 2.3 Intended use SERVO-DRIVE for AVENTOS supports the opening and closing of lift systems in furniture and may only be used under the following conditions: • In dry, enclosed rooms • In combination with AVENTOS lift systems from Julius Blum GmbH within permitted technical specifications • In combination with a Blum transformer Technical data specifications can be found in the Blum sales documentation. ⇒ For more information, please see your distributor. Julius Blum GmbH is not liable for any other use. 2.5 Children NOTICE ⇒ To ensure that lift systems cannot be activated unintentionally, we recom- mend connecting the Blum transformer to a switched outlet. For more infor- mation, please consult an electrician. DANGER Choke danger to children when playing with the Blum switch. Children could choke on the Blum switch battery. ⇒ Make sure that children do not open the Blum switch as they could choke on parts or the battery from the Blum switch. DANGER Opening and closing lift systems may pose a risk of injury to children! Persons, especially children, who are sitting or standing on work surfaces may be pushed from work surfaces or injured when opening and closing a lift system. ⇒ Children should be properly supervised when in the room so that they do not play with the device. ⇒ To ensure that SERVO-DRIVE for AVENTOS is not triggered unintentionally, the outlet should be switched off or unplugged. 5 2.6 Wall cabinet care and cleaning DANGER Danger of electric shock There is a danger of electric shock if fluids penetrate the Blum transformer (page 6, item 3). ⇒ Make sure that no water or aggressive cleaning material comes in contact with the drive unit, Blum transformer or Blum switch while cleaning the wall cabinet. ⇒ Switch off the power to the Blum transformer and/or unplug the unit before cleaning the drive unit. ⇒ Never open a Blum transformer. ⇒ Any cabling damage should be immediately corrected by a qualified specialist. Damage to the drive unit or Blum switch. ⇒ Never take apart a drive unit or Blum switch. Penetrating moisture and aggressive cleaning materials can damage the electron- ics of the drive unit, Blum transformer and Blum switch. ⇒ The drive unit, Blum transformer and Blum switch should only be cleaned with a moist cloth. The Blum transformer can be damaged if covered by towels or other items due to overheating. ⇒ Do not cover the Blum transformer with towels or other items. WARNING There is a danger of injury if the lever springs upward. There is a danger of injury from the lever springing upwards due to improper removal of the front including fittings. ⇒ Never remove the front for cleaning. ⇒ Front removal may only be carried out by qualified personnel according to the separate installation inst…

Text truncated - open the document above for the full version.

Block Diagram

Projekt: GT-10898 19.02.2009 ZF Electronics GmbH Seite 1 von 1 Blockschaltbild Funktaster ¬ nRF24LE1 (QFN24) Batterie CR2032 LP-Antenne Taster LED-Statusanzeige Low Battery LED-Statusanzeige Reverse Battery Verpolschutz

External Photos

TRPS GmbH Testreport Nr. 21140994_002 Appendix 2 Seite [page] 5 von [of] 7 Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark on this or similar products. FCC_21140994_002_Foto_i.doc EUT 21P5020 TRPS GmbH Testreport Nr. 21140994_002 Appendix 2 Seite [page] 6 von [of] 7 Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark on this or similar products. FCC_21140994_002_Foto_i.doc 21FA011 21FA011 TRPS GmbH Testreport Nr. 21140994_002 Appendix 2 Seite [page] 7 von [of] 7 Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark on this or similar products. FCC_21140994_002_Foto_i.doc Power Supply

ID Label/Location Info

Labels for Blum:

ID Label/Location Info

TRPS GmbH Testreport Nr. 21140994_002 Appendix 2 Seite [page] 6 von [of] 7 Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark on this or similar products. FCC_21140994_002_Foto_i.doc 21FA011 21FA011

Internal Photos

TRPS GmbH Testreport Nr. 21140994_002 Appendix 2 Seite [page] 1 von [of] 7 Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark on this or similar products. FCC_21140994_002_Foto_i.doc Anhang 2 Appendix 2 Fotodokumentation Photo Documentation TRPS GmbH Testreport Nr. 21140994_002 Appendix 2 Seite [page] 2 von [of] 7 Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark on this or similar products. FCC_21140994_002_Foto_i.doc EUT 21FA011 EUT 21FA011 TRPS GmbH Testreport Nr. 21140994_002 Appendix 2 Seite [page] 3 von [of] 7 Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark on this or similar products. FCC_21140994_002_Foto_i.doc EUT 21P5020 TRPS GmbH Testreport Nr. 21140994_002 Appendix 2 Seite [page] 4 von [of] 7 Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark on this or similar products. FCC_21140994_002_Foto_i.doc EUT 21P5020 EUT 21P5020

Operational Description

Operational Description 21P5020 The IC U1 (nRF24LE1) is the main controller, which includes a microcontroller and a circuitry to generate 2.4 GHz RF signals. The IC U1 stores and runs the application program that controls the operation of the System. It requires only one timing input from a 16 MHz clock generated by the crystal Q1. It receives 3 V DC from a build in battery. 2 indicator LED’s shows: 1. if the transmitter transmit 2. indicated low voltage. The RF Output from the U1 is routed via a Balun circuit to an on-board printed antenna.. 21.A00L33 The IC U1 (nRF24LE1) is the main controller, which includes a microcontroller and a circuitry to receive a 2.4 GHz RF signals, and also a demodulation unit. The IC U1 stores and runs the application program that controls the operation of the System. It requires only one timing input from a 16 MHz clock generated by the crystal Q1. It receives 3.3 V DC from an external power supply. 2 indicator LED’s shows: 1. if there an incoming RF Signal 2. indicated low voltage. The RF Input to the U1 is routed via a Balun circuit to an on-board printed antenna.. The Switches S1 – S4 are used only for the first setup. The output’s going to the engine for open or close the door.

Schematics

33nF C12 22k/1% R1 100 R2 22pF/50V C2 22pF/50V C3 100nF/10V C4 1pF C5 100nF/10V C6 2.2nF/50V C8 6.8nH/5% L1 6.8nH/5% L2 5.6nH L3 1.5pF/50V C9 100nF/10V C10 100nF/10VC11 100uF/6.3V C13 100k R3 330 R4 BLM15AG221SN1 L4 100nF/10V C1 Q1 16MHz SW1 SKSCPBE010 D1 16-213SURC/S530 R5 10k C15 33nF 16-213SURC/S530 D2 TP1 TP2 TP3 TP4 TP5 TP6 TP7 TP8 TP9 BAS70 D3 BAT54 D4 BAT1 3.0 V BAT2 Funkschalter_Sender 620-1612 Plot-Date: 04.03.2009 of: 01 Page: 01 File: C:\MentorGraphics\Projekte\620\620-1612_02\620-1612.sbk GT 10898 ZF Electronics GmbH Cherrystrasse 91275 Auerbach/Opf. revdate drawer engineer HVengineer FVSAP-modification-no.pcb-no./rev.approval replacement for: drawing-no: title: Diese Zeichnung darf ohne unsere Genehmigungweder vervielfältigt noch dritten Personen zurEinsicht oder zu anderen Zwecken überlassennoch anderweitig mißbräuchlich benutzt werden.(§ 18 UWG) This drawing is property ofZF Electronics GmbH and must not becopied or used for manufacturingwithout written permission(§ 18 UWG) 1 2 34 1 2 34 A B C D E F A B C D E F 6 17 20 2 7 18 21 23 22 14 13 12 11 10 9 8 1 24 5 19 4 3 16 15 nRF24LE1 U1 PROG RST DEC2 DEC1 P0.0 VDD4 P0.3 P0.5 P0.4 IREF VDD_PA ANT2 ANT1 XC2 XC1 VDD1 VDD2 VSS1 VSS2 VSS3 VDD3 P06 P0.2 P0.1 SW1 Pin1 connected to VCC601-20492/01D.P.04.03.0902 H.-J. H. H.-J. H. 0105.02.09D.P.601-20492/00LS1, LS2 removed / PCB-layout reworked first editionVS-36327/00D.P.22.01.0900 Antenna

Schematics

1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 DD CC BB AA solve gmbh hard & software engineering gewerbestrasse 4 9470 buchs / switzerland tel. +41 (0)81 750 53 53 AVENTOS SERVO-DRIVE solve/bm 06.04.200915:10:50 D:\Projects\Blum\Servo-Drive Aventos\Hauptprint\Altium Designer\Servo-Drive Aventos.SchDoc Version:Drawn By: Date: File: SheetofTime: V3.x Infineon BAS40 13 D1.0 +24V 100nF C2.0 TP2.8B ANI1/P21 1 ANI0/P20 2 P01/TIO10/TO00 3 P00/TI000 4 P120/INTP0/EXLVI 5 RESET 6 FLMD0 7 P122/X2/EXCLK/OCD0B 8 P121/X1/OCD0A 9 REGC 10 Vss 11 Vdd 12 P60/SCL0 13 P61/SDA0 14 P33/TI51/TO51/INTP4 15 P32/INTP3/OCD1B 16 P31/INTP2/OCD1A 17 P30/INTP1 18 P17/TI50/TO50 19 P16/TOH1/INTP5 20 P15/TOH0 21 P14/RxD6 22 P13/TxD6 23 P12/SO10 24 P11/SI10/RxD0 25 P10/SCK10/TxD0 26 AVref 27 AVss 28 ANI3/P23 29 ANI2/P22 30 uPD78F0501AMC-CAB-AX IC2.0 1A / 125VAC / 8 circuits 1 2 3 4 5 6 7 8 X2.0 Programmierstecker GND +3.3V RxD TxD GNDGND SPEED TxD RxD GND+3.3V +3.3V +3.3V 470nF C2.1 GND CURRENT_SENSE TP2.0B TP2.2BTP2.3BTP2.4BTP2.5B TP2.1B TP2.7BTP2.6B SWITCH 1k R2. 0 +3. 3V+24V1 GND PM1 Pass Marker PM2 Pass Marker PM3 Pass Marker LED ANGLE SPI_CLK(CLK)/SYN_OUT RESET_EXT 10k 1234 8765 R2. 3 C1632C102K 5R n.a. 1nF 8 1 7 4 6 2 5 3 C9. 0 C1632C102K 5R n.a. 1nF 8 2 7 3 6 1 5 4 C9. 1 C1632C102K 5R n.a. 1nF 8 1 7 2 6 3 5 4 C9. 2 P ES D 3V 3L4U G n.a. 2 3145 D9. 0 P ES D 3V 3L4U G n.a. 2 3145 D9. 1 P ES D 3V 3L4U G n.a. 2 3145 D9. 2 GNDGNDGND GNDGNDGND SWITCH SPI_CLK(CLK)/SYN_OUT SPI_SDI(MOSI)/COL_IN SPI_SDO(MISO)/COL_OUT SPI_CS(CS)/RES0 RES4/SYN_IN TYPE RES3 CONNECT TYPE TP9. 1B +3. 3V RDC506002A 1 3 2 R8. 0 1M R8. 1 10nF C8. 1 +3. 3V TP8. 0B TP8. 2B GND ST TS912IDT 2 3 1 A V + V - 8 4 IC8. 1A ST TS912IDT 5 6 7 B V + V - 8 4 IC8. 1B +3. 3V GND 510k R8. 8 100nF C8. 9 560k R8. 4 10nF C8. 5 30k R8. 5 30k R8. 6 +3. 3V GND 51k R8. 7 1uF C8. 8 ACC 27k R8. 2 1uF C8. 4 SPEED TP8. 7B 100nF C8. 6 GND TP8. 5B TP8. 9B ANGLE TP2. 9B GND TYPE CONNECT 10k 1234 8765 R2. 2 GND GND 1k n.a. R2. 1 GSOT03C 3 12 D7. 0 GSOT03C 3 12 D8. 0 RES2 RES1 S MA J 26CA D9. 3 GND 1nF C9. 3 GND TP9. 2B TP9. 3B TP9. 4B TP9. 5B TP9. 6B TP9. 7B TP9. 8B TP9. 9B TP9. 10B TP9. 11B TP9. 12B TP9. 13B TP9. 14B SPI_CS(CS)/RES0 SPI_SDO(MISO)/COL_OUT SPI_SDI(MOSI)/COL_IN 0.5A / 50V / 20 circuits 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 X9. 0 Wireboard/RF -Board Connector 5A / 250V A C / 2 circuits 11 X0. 0A 5A / 250V A C / 2 circuits 22 X0. 0B 5A / 125V D C F0. 0 LED orange D7. 1 330E R7. 0 TP7. 1B +24V1 100nF C1. 1 GNDGND +3. 3V TP1. 0B 22uF C1. 2 GND LED TP7. 2B GSOT03C 3 12 D7. 3 GND 240E R1. 0 10uF C1. 0 GND On Semiconductor NCV4264-2ST33T3G IN 1 OUT 3 2 GND IC1. 0 B e m: Kühlfläche min. 100mm2 22uF n.a. C1.3 GND RES2 RES1 RES4/SYN_IN 50mA / 12V / NO 1 2 S7.0 SENSE_INT ACC BRAKEZ ENABEL(PWM) DIR A4931 HA+ 1 HA- 2 HB+ 3 HB- 4 HC+ 5 HC- 6 GND 7 HBIAS 8 CP1 9 CP2 10 VBB 11 VCP 12 SENSE 13 GLC 14 GLB 15 GLA 16 GHC 17 SC 18 GHB 19 SB 20 GHA 21 SA 22 FG1 23 FG2 24 CLD 25 DIR 26 ENABLE 27 BRAKEZ 28 IC3.0 100nF C3.5 100nF C3.4 100nF C3.6 MGND MGND 100nF C3.7 GND +3.3V 100nF C3.3 10k n.a. R3.4 10k n.a. R3.5 +3.3V MGND GND GND's an einer Stelle zus ammenführen BRAKEZ ENABEL(PWM) DIR 6A / 40V 2 7 1 8 IC3.1A 6A / 40V 2 7 1 8IC3.2A 6A / 40V 4 6 3 5 IC3.1B 6A / 40V 4 6 3 5 IC3.2B 10A / 250VAC 111 X3.0A 222 X3.0B n.a. SMAJ26CA D3.2 n.a. SMAJ26CA D3.3 MGNDMGND 0.033E R3.2 0.04E n.a. R3.3 MGND SMAJ26CA D3.1 10uF C3.0 10uF C3.1 10uF n.a. C3.2 MGND Usense1 Usense2 5A / 40V 1 2 D3.0 +24V 10k R3.20 10k R3.21 100pF n.a. C3.20 n.a. GSOT03C 3 12 D3.20 GND 100k R3.22 GND 100k R3.23 5.6k R3.24 100pF C3.22 GND ST TS391 3 4 1 A 5 2 V+ V- IC3.21 +3.3V 100nF C3.23 GND 22k R3.26 27k R3.25 +3.3V GNDGND 100nF C3.24 GND 10k n.a. R3.27 +3.3V CURRENT_SENSE SENSE_INT 6.8uH, 4.2A L3.0 SMAJ26CA D0.0 MGND 0E n.a. R3.0 0E n.a. R3.1 100nF C8.0 GND +3.3V 100nF C8.3 GND 10nF C8.2 GNDGNDGNDGNDGND 5k6 R8.3 100nF C8.7 GND TP3.12BTP3.11BTP3.8BTP3.9BTP3.10B TP3.17BTP3.18BTP3.19BTP3.20B TP3.25B TP3.26B TP3.22BTP3.23BTP3.24B TP3.7B TP3.3BTP3.4B TP3.0B TP3.1B TP3.2B TP3.31B TP3.30B TP3.33B TP8.6B TP8.4B TP8.10B TP8.3B TP8.1B TP7.0B TP1.2BTP0.2BTP0.0B TP0.1B TP1.1B TP8.8B TP3.16BTP3.15BTP3.14BTP3.21B TP3.27B TP3.28B TP2.10B 100nF n.a. C2.2 TP3.29B TP3.35B TP3.34BTP3.32B TP3.6B TP3.5B TP3.22TTP3.23TTP3.24T TP3.34T TP3.35T TP3.32T TP3.5T TP3.6T TP3.21T TP3.20T TP3.19T TP3.18T TP3.3TTP3.4T TP3.2T TP3.0T TP8.10T TP8.7T TP8.6T TP8.3T TP8.1T TP8.0T TP7.0T TP1.2TTP1.1TTP0.2TTP0.0T TP0.1T TP2.2TTP2.3T TP3.27T TP3.28T 81150E R3.6A 72150E R3.6B 63150E R3.6C 54150E R3.6D MAINBOARD V3.x 21.A00L31 PRINT GND GND +3.3V 100nF C3.21 0E n.a. R8.9 TI LMV321IDBV 3 1 4 A 5 2 V+ V- IC8.0 TI LMV321IDBV 3 1 4 A 5 2 V+ V- IC3.20 RES3 +3.3V Digitale Drehzahlmessung 1 2 3 4 5 6 X10.0 GND +24V1 CH_A CH_B CH_A CH_B TP2.4TTP2.5TTP2.6TTP2.7T TP2.0T TP2.1T TP9.14TTP9.13TTP9.7T C3.25 10nF MGND MGND 10A / 250VAC PIC10001 PIC10002 COC100 PIC10101 PIC10102 COC101 PIC10201 PIC10202 COC102 PIC10301 PIC10302 COC103 PIC20001PIC20002 COC200 PIC20101 PIC20102 COC201 PIC20201PIC20202 COC202 PIC30001 PIC30002 COC300 PIC30101 PIC30102 COC301 PIC30201 PIC30202 COC302 PIC30301 PIC30302 COC303 PIC30401PIC30402 COC304 PIC30501PIC30502 COC305 PIC30601PIC30602 COC306 PIC30701 PIC30702 COC307 PIC302001 PIC302002 COC3020 PIC302101PIC302102 COC3021 PIC302201 PIC302202 COC3022 PIC302301PIC302302 COC3023 PIC302401 PIC302402 COC3024 PIC302501PIC302502 COC3025 PIC80001 PIC80002 COC800 PIC80101 PIC80102 COC801 PIC80201 PIC80202 COC802 PIC80301PIC80302 COC803 PIC80401PIC80402 COC804 PIC80501PIC80502 COC805 PIC80601PIC80602 COC806 PIC80701 PIC80702 COC807 PIC80801PIC80802 COC808 PIC80901PIC80902 COC809 PIC90001PIC90002PIC90003PIC90004 PIC90005PIC90006PIC90007PIC90008 COC900 PIC90101PIC90102PIC90103PIC90104 PIC90105PIC90106PIC90107PIC90108 COC901 PIC90201PIC90202PIC90203PIC90204 PIC90205PIC90206PIC90207PIC90208 COC902 PIC90301 PIC90302 COC903 PID00001 PID00002 COD000 PID10001PID10003 COD100 PID30001 PID30002 COD300 PID30101 PID30102 COD301 PID30201 PID30202 COD302 PID30301 PID30302 COD30…

Text truncated - open the document above for the full version.

Schematics

Projekt: GT-10898 04.05.2009 ZF Electronics GmbH Page 2 of 3 ¬ Schematic Receiver Projekt: GT-10898 04.05.2009 ZF Electronics GmbH Page 3 of 3 ¬ BOM Receiver Designator Part Description Pcs. ST1 PCB Connector 20pin 1 Q1 Crystal 16MHz ±15ppm (TSX-3225) 1 R13 Resistor 100k, 5% 1 C6 Capacitor 1pF +-0,1pF, 50V, NPO 1 C3 Capacitor 4.7pF 5%, NPO 1 C5 Capacitor 1.5pF +-0,1pF, 50V, NPO 1 U1 ASIC nRF24LE1, QFN32, (Nordic Semiconductor) 1 L1-L2 Inductor 6.8nH/5% (wired wound) 2 L3 Inductor 5.6nH/5% (wired wound) 1 D1 LED (red) 17-21SURC/S530-A2/TR8 1 D2 LED (green) 17-21VGC/TR8 1 R5 Resistor 10k 5% 1 R3,R6-R12,R14 Resistor 100R 5% 9 R2,R4 Resistor 330R 5% 2 R1 Capacitor 22k 1% 1 C12,C16 Capacitor 10uF 10%, 6.3V 2 C17-C23 Capacitor 1nF 5%, 50V 7 C1-C2 Capacitor 22pF 5%, 50V 2 C8,C10 Capacitor 33nF 5%, 50V 2 C4 Capacitor 2.2nF 5%, 50V 1 C7,C9,C11,C15 Capacitor 100nF+80/-20%, 10V 4 L4 Bead BLM15AG221SN1 1 PCB Material: FR4, d=1.0mm 1

Test Report

TRPS GmbH Testreport Nr. 21140994_002 Seite [page] 2 von [of] 22 FCC ID: W95-21A00L33 IC: 8352A-21P5020 FCC ID: W95-21P5020 IC: 8352A-21A00L33 The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not referred to herein. This testreport may not be published or duplicated in part without permission of the testing body. This testreport by itself does not constitute authorization for the use of any test mark. This report must not be used by the applicant to claim product endorsement by TUV Rheinland, NVLAP or any agency of the United States Government. FCC_21140994_002.doc Verwendete Messgeräte sind in der linken Spalte mit einem Kreuz x markiert [used instruments are marked with an x in the left column] Störaussendung [emission] Test / Gerät [test / device] Type Hersteller [manufacturer] Inv. – Nr. /Ser. - Nr. kal. bis [cal. till] Funkstörspannung / –strom [conducted disturbance] x EMI Receiver 9kHz-30MHz FMLK 1518 D Schwarzbeck 14200382 2009-08 x Netznachbildung [AMN] ESH 3-Z5 Rohde & Schwarz 14200683 2010-05 x Schirmkabine [shielded room] B 83102 S1-X10 Siemens --- --- Elektr. Funkstörfeldstärke 2 [radiated disturbance SAC] EMI Receiver 25-1000MHz VUMA 1521 A Schwarzbeck 14200621 2009-01 EMI Receiver 25-1000MHz VUMA 1524 Schwarzbeck 14200418 2009-03 EMI Receiver < 2,75GHz ESCS 30 Rohde & Schwarz 14201360 2010-01 EMI Receiver < 26,5GHz ESU 26 Rohde & Schwarz 30401912 2009-11 x EMI Receiver < 26,5GHz ESMI Rohde & Schwarz 14200550 2010-10 x BiConiLog-Ant 26-3000MHz 3142B EMCO 14201363 2011-06 Horn-Ant. 0,8-5GHz BBHA 9120A Schwarzbeck 30402211 2010-09 x Horn-Ant 1-10GHz BBHA 9120B 202 Schwarzbeck 14200694 2010-02 Horn-Ant 1-10GHz BBHA 9120B 204 Schwarzbeck 14200695 2009-10 Horn-Ant 2-18GHz BBHA 9120C 376 Schwarzbeck 30401857 2009-07 x Horn-Ant 2-18GHz BBHA 9120C 377 Schwarzbeck 30401858 2009-03 Horn-Ant 15-26,5GHz BBHA 9170 311 Schwarzbeck 30401855 2009-03 x Horn-Ant 15-26,5GHz BBHA 9170 312 Schwarzbeck 30401856 2009-03 x Semi Anechoic Chamber SAC ETS 14201372 2010-06 Weitere Messgeräte [other testequipment] Type Hersteller [manufacturer] Inv. – Nr. /Ser. - Nr. kal. bis [cal. till] Digital-Multimeter Metra Hit 16 ABB 14200346 2010-06 x Digital-Multimeter Metra Hit 23S Gossen 14200699 2009-09 Oszilloskop [oscilloscope] TDS 3052B Tektronix 30401734 2010-02 x Temperature / Humidity 615 testo 30401660 2009-08 Equipment requiring calibration is calibrated periodically by the manufacturer or according to manufacturer’s specifications. Additionally all equipment is verified for proper performance on a regular basis using in house standards or comparisons. All measurement equipment calibrations are traceable to DKD or where calibration is performed outside Germany, to equivalent nationally recognized standards organizations. The measurement facilities for conducted and for radiated disturbances of TRPS GmbH in Cologne, Am Grauen Stein, has been found to be in compliance with the requirements of Section 2.948 of the FCC Rules. Measurement data will be accepted in conjunction with applications for Certification under Parts 15 and 18 of the Commission ́s Rules. Registration-Number: 91096 Date of Listing: 2007-Dec-05 TRPS GmbH Testreport Nr. 21140994_002 Seite [page] 3 von [of] 22 FCC ID: W95-21A00L33 IC: 8352A-21P5020 FCC ID: W95-21P5020 IC: 8352A-21A00L33 The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not referred to herein. This testreport may not be published or duplicated in part without permission of the testing body. This testreport by itself does not constitute authorization for the use of any test mark. This report must not be used by the applicant to claim product endorsement by TUV Rheinland, NVLAP or any agency of the United States Government. FCC_21140994_002.doc Messunsicherheit [measurement uncertainty] Where relevant, following measurement uncertainty levels have been estimated for tests performed on the apparatus. Expanded Uncertainty U Lab U CISPR Conducted Emission 0,15 to 30 MHz, Power Line 2,70 dB 3,6 dB Radiated Emission 9kHz to 30MHz, Magnetic Field 3m 4,16 dB 5,2 dB Radiated Emission 30 to 300MHz, OATS 3m or 10m 5,11 dB 5,2 dB Radiated Emission 300 to 1000MHz, OATS 3m 4,71 dB 5,2 dB Radiated Emission 30 to 1000MHz, Semi Anechoic Chamber 3m 4,91 dB 5,2 dB Radiated Emission 1000 to 2750MHz, Semi Anechoic Chamber 3m 4,89 dB under consid. Calculated in accordance with UKAS LAB 34 Uncertainty figures are valid to a confidence level of 95% Test period : 2009-03-05 till 2009-04-14 TRPS GmbH Testreport Nr. 21140994_002 Seite [page] 4 von [of] 22 FCC ID: W95-21A00L33 IC: 8352A-21P5020 FCC ID: W95-21P5020 IC: 8352A-21A00L33 The test results contained in this report refer exclusively to the product(s) presented for testing. No liability may be assumed for models or products not referred to herein. This testreport may not be published or duplicated in part without permission of the testing body. This testreport by itself does not constitute authorization for the use of any test mark. This report must not be used by the applicant to claim product endorsement by TUV Rheinland, NVLAP or any agency of the United States Government. FCC_21140994_002.doc 1. Vereinbarungen [requirements and agreements] Auftragsgemäß wurde an dem vorgestellten Prüfling eine EMV-Prüfung durchgeführt. Die Prüfung erfolgte nach den folgenden Grundlagen. [The tested device got investigated by the following requirements and standards] Störaussendung [Emission] FCC 47 CFR Ch.1 Part 15 Section 15.207 (a) limits same as IEC/CISPR 22:1997 Class B (EN 55022:1998 Kl. B) Störspannung, AC-Eingang [conducted noise, AC power input] Section 15.109 (a) Class B El. Störfeldstärke [radiated el. noise] Section 15.209 Section 15.249 El. Störfeldstärke [radiated el. noise] Section 15.31 (e) and Section 15.215 (c) Voltage Variation Bandedge…

Text truncated - open the document above for the full version.

Test Setup Photos

TRPS GmbH Testreport Nr. 21140994_002 Appendix 1 Seite [page] 1 von [of] 3 Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark on this or similar products. FCC_21140994_002_setup.doc Anhang 1 Appendix 1 Fotodokumentation Photo Documentation Testaufbau / Testsetup TRPS GmbH Testreport Nr. 21140994_002 Appendix 1 Seite [page] 2 von [of] 3 Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark on this or similar products. FCC_21140994_002_setup.doc Set-up for Conducted Emission W95-21A00L33 and W95-21P5020 are build in for testing Set-up for Radiation Emission test figure for W95-21A00L33 TRPS GmbH Testreport Nr. 21140994_002 Appendix 1 Seite [page] 3 von [of] 3 Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark on this or similar products. FCC_21140994_002_setup.doc Set-up for Radiation Emission test figure for W95-21P5020

Contact Information

Applicant

Thomas MAIER
[email protected]0043 5578 705-3796Fax: 0043 5578 705-53796

Test Firm

TUV Rheinland LGA Product GmbHKlaus- Wilhelm Friedrich
[email protected]49-221-806-1561Fax: 49-221-806-3907

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Modular Type
Limited Single Modular Approval

Other Applications from Julius Blum GmbH

SERVO DRIVE for AVENTOS HF/HS/HL top - FCC ID W95-23A001 - Julius Blum GmbH
W95-23A001

SERVO DRIVE for AVENTOS HF/HS/HL top

Oct 22, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Remote Control to open and close cupboard doors - FCC ID W95-21P5020 - Julius Blum GmbH
W95-21P5020

Remote Control to open and close cupboard doors

Dec 22, 2009

Equipment Class