Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1 2 3a3b 4 5 6 7 1 2 3 4 16 SERVO-DRIVE Lift mechanism, drive unit and cover cap Lever arm SERVO-DRIVE transformer SERVO-DRIVE plug-in transformer SERVO-DRIVE switch Blum distance bumper Cabinet Front/Lift system Reference diagram SERVO-DRIVE for AVENTOS supports the opening and closing of lift systems in furniture. Drive unit Eject lever SERVO-DRIVE transformer Blum distance bumper Reference diagram SERVO-DRIVE supports the opening of drawers. SERVO-DRIVE for AVENTOS/SERVO-DRIVE uno for AVENTOS SERVO-DRIVE for LEGRABOX/TANDEMBOX/MOVENTO/ TAN D E M 1 2 3a 3b 4 5 6 7 1 2 3 4 1 2 3 4 5 8 6 7 1 2 3 4 6 7 5 17 SERVO-DRIVE EN EN Drive unit Catch plate Mounting plate Front fixing Blum distance bumper Assembly jig Front cover Chipboard screws Drive unit Catch plate Mounting plate Front fixing Assembly jig Front cover Chipboard screws Orientation diagram SERVO-DRIVE flex for refrigerators and freezers 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 Orientation diagram SERVO-DRIVE flex for dishwashers SERVO-DRIVE flex allows handle-less refrigerators and freezers to be opened electromechanically by pressing the front. SERVO-DRIVE flex allows handle-less dishwashers to be opened electromechanically by pressing the front. 1 2 18 SERVO-DRIVE Press on the front ➢ The lift system opens automatically Press on the SERVO-DRIVE switch ➢ The lift system closes automatically The SERVO-DRIVE switch triggers the automatic opening and closing action of SERVO-DRIVE for AVENTOS. Electrical motion support system SERVO-DRIVE for AVENTOS/SERVO-DRIVE uno for AVENTOS 19 SERVO-DRIVE EN EN The opening and closing action is inter- rupted automatically via the integrated collision detection feature when the front hits a body part or other object. Collision detection Lean protection feature ➢ Manual closing of the lift system by moving it downwards ➢ Manual opening of the lift system by moving it upwards The lift system can be opened or closed manually at any time without damaging SERVO-DRIVE for AVENTOS. Manual operation SERVO-DRIVE for AVENTOS is only trig- gered by a brief touch. Leaning on the lift system will not open it. 1 2 20 SERVO-DRIVE A Power failure If the power supply is interrupted during the opening or closing process, the SERVO-DRIVE for AVENTOS lift system will remain in that position. The front can be closed manually, or when power is restored; simply touch the switch to re-activate SERVO-DRIVE function. The following parameters must be observed to ensure the error-free functioning of SERVO-DRIVE for AVENTOS: • Blum distance bumpers must be attached to the front to maintain the required distance between the lift system and the cabinet. • No items should be placed between the front and the cabinet. ➢ Improper use may cause SERVO-DRIVE for AVENTOS to wear prematurely! ➢ Do not press or pull with force against the movement direction when opening or closing the lift system. ➢ Never remove the front. Front removal may only be carried out by qualified personnel. See also the safety section at the first pages of this leaflet. Battery display (LED) Connect (LED) SERVO-DRIVE switch The SERVO-DRIVE switch is battery-operated (CR2032). Only use batteries from reputable manufacturers. NOTE 1 2 1 2 1 2 3 4 21 SERVO-DRIVE A EN EN Replacing the battery When the battery power begins to weaken, the battery display (LED) will begin to flash red. Open the SERVO-DRIVE switch and remove the battery holder Remove the battery Insert new battery (type CR2032), observing the correct pole connections Close battery holder The SERVO-DRIVE switch battery must not be recharged or discarded into fire. If the battery is inserted incorrectly, the SERVO-DRIVE switch battery display will lights up red. NOTE 1 2 3 4 22 SERVO-DRIVE Electrical motion support system When the front and/or handle of the drawer (A) is pulled or pressed, the eject lever of the drive unit (B) swivels forward and opens the pull-out unit a short distance. The electrical opening support function is only triggered by a brief touch or pull. Leaning on the pull-out unit, for example, will not open it. Lean protection feature SERVO-DRIVE for LEGRABOX/TANDEMBOX/MOVENTO/ TAN D E M 1 2 3 2 3 23 SERVO-DRIVE EN EN Power connection Operating mode display (LED) Serial tag The following parameters must be observed to ensure the error-free functioning of SERVO-DRIVE: • Blum distance bumpers must be attached to the front to ensure the required trigge- ring signal (2 mm) between the pull-out unit and the cabinet. • No items can be clamped between the pull-out unit and the cabinet back and/or SERVO-DRIVE. ➢ Improper use may cause SERVO-DRIVE for pull-out systems to wear prematurely! ➢ Do not press or pull with force against the movement direction when opening or closing the drawer. NOTE 1 2 3 SERVO-DRIVE transformers provide power to the drive unit. SERVO-DRIVE transformer function can be checked via the operating mode indicator (LED). SERVO-DRIVE transformers 2a 2b < 3 s > 3 s 2a 2b < 3 s > 3 s 2 1 24 SERVO-DRIVE 1) Press (do not pull) the front ➢ The door (refrigerator or dishwasher) will open slightly for 2.5 sec 2) User utilises opening to grip door ➢ Continues opening process 2b) User does not touch door ➢ Door closes again Pressing the handle-less front will trigger the electromechanical opening of SERVO-DRIVE flex. Electrical motion support system SERVO-DRIVE flex 25 SERVO-DRIVE EN EN Battery display on SERVO-DRIVE switch flashes red. Battery display lights up red SERVO-DRIVE for AVENTOS does not open or close com- pletely. SERVO-DRIVE for AVEN- TOS does not work on one particular lift system when pressing on the front or using the SERVO-DRIVE switch. SERVO-DRIVE for AVENTOS does not close completely. [OK] button of drive unit lights up red continuously. SERVO-DRIVE switch battery is losing power. Battery has been inserted incorrectly. The front is not balanced or does not lie flat on the cabinet evenly. SERVO-DRIVE switch battery has run out of power. Battery was inserted incor- rectly. SERVO…
Text truncated - open the document above for the full version.
Page | 1 Photos of Drive Unit 23.A001 Note: all used units are centimeters External photos: Julius Blum GmbH Industriestraße 1 6973 Höchst Österreich P +43 5578 7 05-0 F +43 5578 7 05-44 www.blum.com
Label Location
Page | 2 Photos of Drive Unit 23.A001 Note: all used units are centimeters PCB 23.A00L80: Julius Blum GmbH Industriestraße 1 6973 Höchst Österreich P +43 5578 7 05-0 F +43 5578 7 05-44 www.blum.com Page | 1 Photos of Radio Module 23.A00L83 Note: all used units are centimeters Radio Module with shield: Julius Blum GmbH Industriestraße 1 6973 Höchst Österreich P +43 5578 7 05-0 F +43 5578 7 05-44 www.blum.com Page | 2 Photos of Radio Module 23.A00L83 Note: all used units are centimeters Radio Module without shield: Julius Blum GmbH Industriestraße 1 6973 Höchst Österreich P +43 5578 7 05-0 F +43 5578 7 05-44 www.blum.com
Prüfbericht - Produkte Test Report – Products Prüfbericht-Nr.: Test report no.: DE22QW97 002 Auftrags-Nr.: Order no.: 1110669_100 Seite 1 von 47 Page 1 of 47 Kunden-Referenz-Nr.: Client reference No.: Auftragsdatum: Order date: 2022-03-15 Auftraggeber: Client: Julius Blum GmbH, Industriestr. 1, 6973 Höchst, Österreich Prüfgegenstand: Test item: Servo Motor (household appliance) Bezeichnung / Typ-Nr.: Identification / Type no.: SERVO DRIVE for AVENTOS HF/HS/HL top Modell: 23.A001 Auftrags-Inhalt: Order content: Prüfung der Funkparameter nach FCC & ISED Test of radio parameters acc. to FCC & ISED Prüfgrundlage: Test specification: Vollprüfung / Complete test FCC CFR 47 Part 15 Subpart C- §15.249 RSS-210 sec. B10 (b): Issue 10 Wareneingangsdatum: Date of sample receipt: 2022-05-04 Prüfmuster-Nr.: Test sample no.: A003254653-010, -002 Prüfzeitraum: Testing period: 2022-06-09 – 2022-08-01 Ort der Prüfung: Place of testing: Nürnberg Nuremberg Prüflaboratorium: Testing laboratory: Wireless Labor Wireless Test Lab Prüfergebnis*: Test result*: Pass geprüft von: tested by: X S i g n i e r t v o n : S a m i U l l a h genehmigt von: authorized by: X S i g n i e r t v o n : P a t r i c k R e u s c h Datum: Date: 2022-09-29 Sami Ullah Datum: Issue date: 2022-09-29 P. Reusch Stellung / Position Sachverständige(r)/Expert Stellung / Position Head of Laboratory Sonstiges / Other: The test report DE22QW97 002 replaces the test report DE22QW97 001 (FCC and IC IDs’ have been updated) Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: 1 = sehr gut 2 = gut 3 = befriedigend 4 = ausreichend 5 = mangelhaft P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legende: 1 = very good 2 = good 3 = satisfactory 4 = sufficient 5 = poor P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TÜV Rheinland LGA Products GmbH · Tillystraße 2 · D - 90431 Nürnberg · Tel.: +49 911 655 5225 · Fax: +49 911 655 5226 Mail: [email protected] · Web: www.tuv.com Prüfbericht - Produkte Test Report – Products Prüfbericht-Nr.: DE22QW97 002 Test report no.: Seite 2 von 47 Page 2 of 47 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. Prüfbericht - Produkte Test Report – Products Prüfbericht-Nr.: DE22QW97 002 Test report no.: Seite 3 von 47 Page 3 of 47 Anmerkungen Remarks 4 Die Messunsicherheit der in diesem Prüfbericht aufgeführten Messverfahren wird nicht unmittelbar in die Bewertung zur Einhaltung der jeweiligen Grenzwerte mit einbezogen. Es gelten die Anforderungen der Spezifikationen TS 103 051 und TS 100 028-1/-2 in aktueller Form, deren Grundlage der „shared risk“ Ansatz ist. Dieser beschreibt für die jeweilige Norm die maximalen zulässigen Unsicherheitsbeträge unter denen der Messwert als „wahr“ angesehen werden kann. Eine zusätzliche Betrachtung der Messunsicherheit bezü…
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report – Products Products Prüfbericht-Nr.: DE22QW97 002 Test report no.: Seite 39 von 47 Page 39 of 47 Fotodokumentation Photo documentation 5 Test Setup Photo Prüfbericht - Produkte Test Report – Products Products Prüfbericht-Nr.: DE22QW97 002 Test report no.: Seite 40 von 47 Page 40 of 47 Fotodokumentation Photo documentation Test Setup: Radiated Measurements (9 kHz - 30 MHz) Prüfbericht - Produkte Test Report – Products Products Prüfbericht-Nr.: DE22QW97 002 Test report no.: Seite 41 von 47 Page 41 of 47 Fotodokumentation Photo documentation Test Setup: Radiated Measurements (30 MHz - 1 GHz) Prüfbericht - Produkte Test Report – Products Products Prüfbericht-Nr.: DE22QW97 002 Test report no.: Seite 42 von 47 Page 42 of 47 Fotodokumentation Photo documentation Test Setup: Radiated Measurements (1 GHz to 26.5 GHz) Prüfbericht - Produkte Test Report – Products Products Prüfbericht-Nr.: DE22QW97 002 Test report no.: Seite 43 von 47 Page 43 of 47 Fotodokumentation Photo documentation Test Setup: Conducted Measurements Prüfbericht - Produkte Test Report – Products Products Prüfbericht-Nr.: DE22QW97 002 Test report no.: Seite 44 von 47 Page 44 of 47 Fotodokumentation Photo documentation Test Setup: Conducted Emission Measurements
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.45 GHz | - |

Remote Control to open and close cupboard doors
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Remote Control to open and close cupboard doors
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified