W9Z-INTEGRA24Low Power Point-To-Point Transmitter

SAF Tehnika AS
Low Power Point-To-Point Transmitter - FCC ID W9Z-INTEGRA24 - SAF Tehnika AS
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Oct 06, 2014
Application Purpose
Original Equipment
Date of Application
Oct 05, 2014
Equipment Note
Low Power Point-To-Point Transmitter
Frequency Range
24052.50000000 - 24247.50000000
Company
SAF Tehnika AS
Country
Latvia

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User manual Integra Full Outdoor Unit VER 1.7 FW 1.0.8 2 Proprietary notice The information presented in this guide is the property of SAF Tehnika, JSC. No part of this document may be reproduced or transmitted without proper permission from SAF Tehnika, JSC. The specifications or information contained in this document are subject to change without notice due to continuing introduction of design improvements. If there is any conflict between this document and compliance statements, the latter will supersede this document. SAF Tehnika, JSC has no liability for typing errors in this document or damages of any kind that result from the use of this document. To get up to date information about accessories and their availability, please contact sales representative. FODU does not contain serviceable parts. Warranty will not be applicable in the event FODU has been hermetically unsealed. SAF Tehnika, JSC is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: − Reorient or relocate the receiving antenna. − Increase the separation between the equipment and receiver. − Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. − Consult the dealer or an experienced radio/TV technician for help. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Copyright Notice Copyright © 2014 SAF Tehnika, JSC. All rights reserved. SAF Tehnika JSC 3 Contents Chapter 1: OVERVIEW ............................................................................................... 5 Technical specification .......................................................................................... 5 Preliminary RSL Threshold (dBm) and Link Capacity (Mbps) ............................... 6 Maximum Tx Power ...................................................................................................... 7 High Performance antenna specification ................................................................. 7 Ethernet header compression ..................................................................................... 8 Labelling ................................................................................................................ 9 Microwave Radiation ........................................................................................... 10 Chapter 2: INSTALLATION ...................................................................................... 12 Integra FODU: assembling mounting bracket and installing with antenna on a pole ...................................................................................................................... 12 Disassembled mounting bracket and tools required for assembly ................... 12 Changing polarization of Integra FODU and antenna ........................................... 13 Assembly procedure ................................................................................................... 14 Integra-S FODU: attaching to the antenna .......................................................... 17 Chapter 3: WEB GUI ................................................................................................. 20 Initial configuration .............................................................................................. 20 System requirements .................................................................................................. 20 Accessing Integra Web GUI ....................................................................................... 20 Main page ...................................................................................................................... 20 Over The Air ......................................................................................................... 24 Radio ‡ Configuration ............................................................................................... 24 Networking .......................................................................................................... 26 Ethernet ‡ VLAN......................................................................................................... 26 Ethernet ‡ Rate limit..............…

Text truncated - open the document above for the full version.

Cover Letter(s)

.l SAF Tehnika AS 24a, Ganibu dimbis Riga, LV-1005, Latvia www.safteh n ika.com VAT No.: LV40003474109 Phone: +371 67046840 Fax: +371 67046809 E-mai[: info{dsaftehnika.com September 22,2014 FederaI Commu nications Commission Equi pment ApprovaL Services Post 0ffice Box 358315 Pittsburgh, Pennsytvania 15215-531 5 To Whom lt May Concern: Pursuant lo 47 CFR 2.911, SAF Tehnika AS has authorized Mr. Scot Rogers, of Rogers Labs, lnc. to act on SAF Tehnika AS behaLf for the sote and express purpose of processing apptications for equipment authorization. As such, Mr. Rogers is authorized to sign forms, Letters of appLication, request confidentia[ity, and' exchange data and information retating to these matters and submittats. Rogers Labs, lnc. is authorized to receive and exchange data between our company and the authorizing agency. ALI acts carried out by Rogers Labs, lnc. on our behalf shaL[ have the same effects as our own. For instances where our authorized agent signs the apptication for certification on our behatf, I acknowtedge that a[[ responsibitity for comptying with the terms and conditions for certification, as specified by regulation stit[ resides with SAF Tehnika AS. This Authorization is in effect untiI notified to the contrary by SAF Tehnika AS. Andrejs Bogdanovs Product Manager SAF Tehnika AS

Cover Letter(s)

October 2, 2014 Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669 Office of Engineering and Technology Federal Communications Commission Columbia, MD 21046 Applicant: SAF Tehnika AS 24a, Ganibu dambis, Riga Latvia LV-1005 Re: Confidentiality for submittal information regarding FCC ID number W9Z-INTEGRA24 Product: Low Power Point to Point 24 GHz Equipment operating under part 15.249 Dear Sirs: SAF Tehnika requests that the material in the Schematic, Block Diagram, Operational Description, and Internal Photograph exhibits be withheld from public disclosure pursuant to Sections 0.457 and 0.459 of the Commission’s Rules following grant of the application. In support of this request, SAF Tehnika submits the following: Long Term Confidential Files Include Schematics File Name Conf Schem INTEGRA24 1.pdf Schematics File Name Conf Schem INTEGRA24 2.pdf Block Diagram File Name Conf BlkDia INTEGRA24.pdf Operational Description File Name Conf OpDes INTEGRA24.pdf Internal Photographs File Name Conf IntPho INTEGRA24.pdf 1. Identification of the specific information for which confidential treatment is sought: The materials set fourth in the Operational Description, Block Diagram, Internal Photographs, and Schematics, which are segregated from the non-confidential exhibits of the application, are those for which confidentiality is sought. 2. Identification of the Commission proceeding in which the information was submitted or a description of the circumstances giving rise to the submission: The proceeding is that involving the application for equipment authorization (certification) under FCC ID No: W9Z-INTEGRA24 3. Explanation of the degree to which the information is commercial or financial, or contains a trade secret or is privileged: This material includes a detailed theory of operation, circuit diagrams, (schematic diagrams) and any detail including Parts List. As such, this material is treated as highly confidential business information. ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 4. Explanation of the degree to which the information concerns a service that is subject to competition: The material for which confidentiality is sought is employed in the design and manufacture of this transmitting equipment that is offered on a highly competitive basis. Customers for this equipment have a variety of competing sources. 5. Explanation of how disclosure of the information could result in substantial competitive harm: Disclosure would, in effect, give away the fruits of the labors of SAF Tehnika engineering personnel, who have designed the equipment and the manufacturing process. Disclosure would also offer competitors additional unwarranted insight into the state of the product development, thereby allowing competitors an advantage, not available to SAF Tehnika 6. Identification of any measures taken by the submitting party to prevent unauthorized disclosure: The information for which confidential treatment is sought is kept confidential by SAF Tehnika and not made available to third parties except pursuant to non-disclosure agreements. 7. Identification of whether the information is available to the public and the extent of any previous disclosure of the information to third parties: To the knowledge of those preparing this application, the information has not been disclosed publicly heretofore. While the general theory of operation of this equipment has been the subject of numerous disclosures in industry and standards groups as well as in rule making proceedings of the FCC, the protection sought is narrowly drawn and pertains to certain specific implementations of this radio technology. 8. Justification of the period during which the submitting party asserts that the material should not be available for public disclosure: This material should not be disclosed for at least 25 years. While improvements in design are, made disclosure of the design information would lead to insights into both design and manufacturing techniques that could have an adverse competitive effect for many years to come. This equipment is designed for commercial, industrial, and governmental applications. As such, unlike most consumer equipment, this equipment could be used for more than a decade in some cases. As such, it is important that the design not be made available to unauthorized persons who might attempt to use knowledge of the design to compromise the applications for which the equipment will be employed. Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Sincerely, Scot Rogers

Cover Letter(s)

October 2, 2014 Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669 Federal Communications Commission Equipment Approval Services P.O. Box 35815 Pittsburgh, PA 15251-3315 Applicant: SAF Tehnika AS 24a, Ganibu dambis, Riga Latvia LV-1005 Equipment: FCC ID: W9Z-INTEGRA24 FCC Rules: License Exempt Low Power Transmitter operating under part 15.249 Gentlemen: The form 731 and application have been electronically submitted and any attachments will be up loaded to your web site for use in obtaining a grant of certification. Confidentiality is requested as outlined below. Permanent SAF Tehnika AS requests that the material in the Schematics, Block Diagram, Internal Photographs and Operational Description be withheld from public disclosure pursuant to Sections 0.457 and 0.459 of the Commission’s Rules following grant of the application. A statement of confidentiality will be attached with the application at the time of submittal. Exhibit File Schematics Conf Schem INTEGRA24 1.pdf Schematics Conf Schem INTEGRA24 2.pdf Block diagram Conf BlkDia INTEGRA24.pdf Operational Description Conf OpDes INTEGRA24.pdf Internal Photographs Conf IntPho INTEGRA24.pdf Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Sincerely, Scot Rogers Rogers Labs, Inc. Enclosures ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 Phone / Fax (913) 837-3214

Cover Letter(s)

SAF Tehnika AS VAT No.: LV40003474109 24a, Ganibu dambis Phone: +371 67046840 Riga, LV-1005, Latvia Fax: +371 67046840 www.saftehnika.com E-mail: [email protected] Timco Engineering, Inc. 849 NW State Road 45 P.O. Box 370 Newberry, Florida 32669 Re.: Professional Installation Attestation Equipment: FCC: W9Z-Integra24 To Whom It May Concern: JSC SAF Tehnika addresses the following items to ensure that the above referenced equipment is professionally installed: 1. The W9Z-Integra24 will only be sold by JSC SAF Tehnika or one of its authorized dealers. JSC SAF Tehnika and its authorized dealers will be under strict marketing control and will only market and sell the W9Z-Integra24 to professionals. 2. Professional installation is required for the W9Z-Integra24and will be performed only by someone knowledgeable of its use. JSC SAF Tehnika will ensure that the W9Z-Integra24 is only marketed and sold to professionals. 3. The W9Z-Integra24 is not sold to the general public and is sold only for industrial or commercial use by professional installers. Sincerely, Andrejs Bogdanovs Head of testing department JSC SAF Tehnika

Cover Letter(s)

October 2, 2014 Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669 Applicant: SAF Tehnika AS 24a, Ganibu dambis, Riga Latvia LV-1005 FCC ID: W9Z-INTEGRA24 Re: Short-term Confidentiality request for submittal information regarding FCC ID: W9Z-INTEGRA24 Product: License Exempt Low Power Transmitter operating under part 15.249 Dear Sirs: SAF Tehnika AS requests that the following information be withheld from public disclosure pursuant to CFR47 paragraphs 0.457 and 0.459, and KDB 726920 until 45 days after the Grant of Equipment Authorization. Short-term confidential files Exhibit File External Photos Short Term Conf ExtPho INTEGRA24.pdf Test Setup Photos Short Term Conf TSup INTEGRA24.pdf User Manual Short Term Conf UserMan INTEGRA24.pdf Permanent Confidential files Exhibit File Schematics Conf Schem INTEGRA24 1.pdf Schematics Conf Schem INTEGRA24 2.pdf Block diagram Conf BlkDia INTEGRA24.pdf Operational Description Conf OpDes INTEGRA24.pdf Internal Photos Conf IntPho INTEGRA24.pdf Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Sincerely, Scot Rogers ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053

Cover Letter(s)

October 2, 2014 SAF Tehnika AS 24a, Ganibu dambis, Riga Latvia LV-1005 RE: Confidentiality Request For FCC ID: W9Z-INTEGRA24 To Whom It May Concern: This letter serves as an official request for confidentiality status under sections 0.457 and 0.459 of CFR 47. We have requested that the following listed items, which are required to be submitted with this application, be permanently withheld from public review. Schematics Block Diagram Operational Description Internal Photos The material for which confidentiality is sought is employed in the design and manufacture of this transmitting equipment that is offered on a highly competitive basis. Customers for this equipment have a variety of competing sources. Disclosure would, in effect, give away the fruits of the labors of SAF Tehnika AS engineering personnel, who have designed the equipment and the manufacturing process. Disclosure would also offer competitors additional unwarranted insight into the state of the product development, thereby allowing competitors an advantage, not available to SAF Tehnika AS Internal photos should be held confidential for a permanent amount of time. The device is sealed and disassembly would destroy the product. The device will not be accessible by general public and is only serviceable by SAF Tehnika AS or authorized representatives directly. Releasing internal photos will reveal company secrets and take away any competitive advantage in the market. Please contact me if there is any information you may need. Sincerely, Scot Rogers ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053

External Photos

External photographs of equipment under test Top view Bottom view Side view Ports

ID Label/Location Info

Rogers Labs, Inc. SAF Tehnika AS 4405 West 259 th Terrace Models: Integra-S-24 and Integra-24 FCC: W9Z-INTEGRA24 Louisburg, KS 66053 Test #: 140916 IC: 8855A- INTEGRA24 Phone/Fax: (913) 837-3214 Test to: 47CFR 15.249(b) and RSS-210 (A12) Date: October 2, 2014 Revision 1 File: LabelSmpl Intergra24 Page 1 of 1 Label Sample and placement Label Placement

RF Exposure Info

Rogers Labs, Inc. SAF Tehnika AS 4405 West 259 th Terrace Model: Inegra-S-24 FCC: W9Z-INTEGRA24 Louisburg, KS 66053 Test #: 140916 IC: 8855A- INTEGRA24 Phone/Fax: (913) 837-3214 Test to: 47CFR 15.249(b) and RSS-210 (A12) Date: October 2, 2014 Revision 1 File: RFExp Intergra24 Page 1 of 1 MPE Calculation page

Test Report

NVLAP Lab Code 200087-0 Rogers Labs, Inc. SAF Tehnika AS 4405 West 259 th Terrace Models: Integra-S-24 and Integra-24 FCC: W9Z-INTEGRA24 Louisburg, KS 66053 Test #: 140916 IC: 8855A- INTEGRA24 Phone/Fax: (913) 837-3214 Test to: 47CFR 15.249(b) and RSS-210 (A12) Date: October 3, 2014 Revision 1 File: SAF Tehnika Integra 24 TstRpt 140916 Page 1 of 45 Application For Grant of Certification FOR Models: Integra-S-24 and Integra-2 Low Power Point-To-Point Transmitter FCC: W9Z-INTEGRA24 IC: 8855A-INTEGRA24 FOR SAF TEHNIKA AS 24a, Ganibu dambis Riga Latvia LV-1005 Test Report Number 140916 IC Test Site Registration: 3041A-1 Authorized Signatory: Scot D. Rogers NVLAP Lab Code 200087-0 Rogers Labs, Inc. SAF Tehnika AS 4405 West 259 th Terrace Models: Integra-S-24 and Integra-24 FCC: W9Z-INTEGRA24 Louisburg, KS 66053 Test #: 140916 IC: 8855A- INTEGRA24 Phone/Fax: (913) 837-3214 Test to: 47CFR 15.249(b) and RSS-210 (A12) Date: October 3, 2014 Revision 1 File: SAF Tehnika Integra 24 TstRpt 140916 Page 2 of 45 Engineering Test Report For Grant of Certification Application For CFR 47, Paragraph 15.249(b) and Industry Canada RSS-210 (Annex 12) License Exempt Intentional Radiator Module SAF TEHNIKA AS 24a, Ganibu dambis Riga Latvia LV-1005 Models: Integra-S-24 and Integra-24 Low Power Point-To-Point Transmitter Frequency Range: 24,052.5 - 24,247.5 MHz FCC ID: W9Z-INTEGRA24 IC: 8855A-INTEGRA24 Test Report Number: 140916 Test Date: September 16, 2014 Authorized Signatory: Scot D. Rogers Rogers Labs, Inc. 4405 West 259th Terrace Louisburg, KS 66053 Telephone/Facsimile: (913) 837-3214 This report shall not be reproduced except in full, without the written approval of the laboratory. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 Phone / Fax (913) 837-3214 NVLAP Lab Code 200087-0 Rogers Labs, Inc. SAF Tehnika AS 4405 West 259 th Terrace Models: Integra-S-24 and Integra-24 FCC: W9Z-INTEGRA24 Louisburg, KS 66053 Test #: 140916 IC: 8855A- INTEGRA24 Phone/Fax: (913) 837-3214 Test to: 47CFR 15.249(b) and RSS-210 (A12) Date: October 3, 2014 Revision 1 File: SAF Tehnika Integra 24 TstRpt 140916 Page 3 of 45 Table Of Contents TABLE OF CONTENTS .................................................................................................... 3 REVISIONS ....................................................................................................................... 5 FORWARD ....................................................................................................................... 6 OPINION / INTERPRETATION OF RESULTS ................................................................. 6 EQUIPMENT TESTED ...................................................................................................... 7 Equipment Function and Configuration ................................................................................................................ 7 Configuration options for the EUT ......................................................................................................................... 7 APPLICATION FOR CERTIFICATION ............................................................................. 8 APPLICABLE STANDARDS & TEST PROCEDURES .................................................... 9 EQUIPMENT TESTING PROCEDURES .......................................................................... 9 AC Line Conducted Emission Test Procedure ....................................................................................................... 9 Radiated Emission Test Procedure ......................................................................................................................... 9 Diagram 1 Test arrangement for Conducted emissions .......................................................................................... 11 Diagram 2 Test arrangement for radiated emissions of tabletop equipment .......................................................... 12 Diagram 3 Test arrangement for radiated emissions tested on Open Area Test Site (OATS) ............................... 12 TEST SITE LOCATIONS .................................................................................................. 12 LIST OF TEST EQUIPMENT ............................................................................................ 13 UNITS OF MEASUREMENTS .......................................................................................... 14 ENVIRONMENTAL CONDITIONS.................................................................................... 14 INTENTIONAL RADIATORS ............................................................................................ 14 Antenna Requirements ............................................................................................................................................. 14 Restricted Bands of Operation ................................................................................................................................ 14 Table 1 Radiated Emissions in Restricted Bands Data ........................................................................................... 15 Summary of Results for Radiated Emissions in Restricted Bands ......................................................................... 15 AC Line Conducted Emissions Procedure.............................................................................................................. 16 Figure One AC Line Conducted emissions of EUT line 1 ..................................................................................... 17 Figure Two AC Line Conducted emissions of EUT line 2 .................................................................................... 17 NVLAP Lab Code 200087-0 Rogers Labs, Inc. SAF Tehnika AS 4405 West 259 th Terrace Models: Integra-S-24 and Integra-24 FCC: …

Text truncated - open the document above for the full version.

Test Setup Photos

Rogers Labs, Inc. SAF Tehnika AS 4405 West 259 th Terrace Models: Integra-S-24 and Integra-24 FCC: W9Z-INTEGRA24 Louisburg, KS 66053 Test #: 140916 IC: 8855A- INTEGRA24 Phone/Fax: (913) 837-3214 Test to: 47CFR 15.249(b) and RSS-210 (A12) Date: October 2, 2014 Revision 1 File: TSup Intergra24 Page 1 of 2 Test setup photographs Rogers Labs, Inc. SAF Tehnika AS 4405 West 259 th Terrace Models: Integra-S-24 and Integra-24 FCC: W9Z-INTEGRA24 Louisburg, KS 66053 Test #: 140916 IC: 8855A- INTEGRA24 Phone/Fax: (913) 837-3214 Test to: 47CFR 15.249(b) and RSS-210 (A12) Date: October 2, 2014 Revision 1 File: TSup Intergra24 Page 2 of 2

Contact Information

Applicant

Aivis Danovskis(Product Manager)
[email protected]+37166951256Fax: +37167046809

Test Firm

Rogers Labs, a division of The Compatibility CntrPatrick Powell
[email protected]913-837-3214Fax: 913-837-3214

Technical Specifications

#Rule PartsFrequency RangePower Output
115C24.05 GHz - 24.25 GHz-
Confidentiality
Long Term
Grant Notes
This device, including its antenna(s), must be professionally installed as specified in this filing for meeting RF exposure compliance requirements. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 65cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from SAF Tehnika AS

W9Z-ARANETRN

Aranet Radon One Sensor HOME

Sep 01, 2024

Equipment Class

DTS - Digital Transmission System
Point-To-Point Digital Transmission System - FCC ID W9Z-INTEGRA5G8 - SAF Tehnika AS
W9Z-INTEGRA5G8

Point-To-Point Digital Transmission System

Oct 01, 2023

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Hybrid Digital Transmission Transmitter - FCC ID W9Z-ARANETPPL - SAF Tehnika AS
W9Z-ARANETPPL

Hybrid Digital Transmission Transmitter

Apr 17, 2023

Equipment Class

DTS - Digital Transmission System
Hybrid Digital Transmission Transmitter - FCC ID W9Z-A4MK2PRO - SAF Tehnika AS
W9Z-A4MK2PRO

Hybrid Digital Transmission Transmitter

Jun 06, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Digital Transmission Transmitter - FCC ID W9Z-A4MK2HOME - SAF Tehnika AS
W9Z-A4MK2HOME

Digital Transmission Transmitter

Jun 06, 2021

Equipment Class

DTS - Digital Transmission System