FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Mitsubishi Electric Corporation Himeji works/
  3. WAZSKE13301

WAZSKE13301Keyless System SSU

Mitsubishi Electric Corporation Himeji works
Keyless System SSU - FCC ID WAZSKE13301 - Mitsubishi Electric Corporation Himeji works
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Apr 03, 2011
Application Purpose
Original Equipment
Date of Application
Apr 03, 2011
Equipment Note
Keyless System SSU
Frequency Range
0.12500000 - 0.12500000
Company
Mitsubishi Electric Corporation Himeji works
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗
↗
↗
↗

ID Label/Location Info

↗

Internal Photos

↗
↗
↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

【 Confidential 】 The following contents are described in Owners Manual of the vehicle. In Canada, it is described in English and French. FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC/IC This device complies with Part 15 of FCC Rules and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of this device. Le présent appareil est conforme aux la Partie 15 des règles de la FCC et CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Users manual FCC&IC.xls

External Photos

【 Confidential 】 Antenna coil TOP LEFT RIGHT BACK BOTTOM FACE Keyless System (Antenna coil) PHOTO_6_Antenna coil.xls

External Photos

【 Confidential 】 LF Antenna TOP FACE RIGHT BOTTOM BAC K LEFT Keyless System (LF Antenna) PHOTO_6_SSU LF Antenna.xls

External Photos

【 Confidential 】 Model :SKE133-01 Keyless System SSU with Antenna coil & LF Antenna PHOTO_6_SSU system_SKE13301.xls

External Photos

【 Confidential 】 PHOTO_6_SSU_SKE13301.xls Model : SKE133-01 FACE LEFT TOP RIGHT BOTTOM BACK Keyless System (SSU)

ID Label/Location Info

【 Confidential 】 Model : SKE133-01 Label display * * There is no sufficient space and this product will be installed in the vehicle, therefore labelling requirement will be described in the users manual. FCC ID:W AZSKE13301 IC :662F-SKE13301 Model :SKE133-01 MITSUBISHI ELECTRIC COROPORATION Keyless System SSU Label Label Label_SSU_SKE133-01.xls

Internal Photos

【 Confidential 】 LF Antenna BACK FACE Keyless System (LF Antenna) PHOTO_PCB_ASSY_SSU LF Antenna.xls

Internal Photos

 Confidential  Model  SKE133-01 Keyless System (SSU)      Confidential  Model  SKE133-01 FACE Keyless System (SSU)      Confidential  Model  SKE133-01 BACK Keyless System (SSU)    

Internal Photos

【 Confidential 】 Antenna coil Keyless System (Antenna coil) PHOTO_Antenna coil.xls

Test Report

Test report No. : 31BE0219-HO-12-B Page : 2 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 CONTENTS PAGE SECTION 1: Customer information ..................................................................................................... 3 SECTION 2: Equipment under test (E.U.T.) ........................................................................................ 3 SECTION 3: Test specification, procedures & results ........................................................................ 4 SECTION 4: Operation of E.U.T. during testing ................................................................................. 8 SECTION 5: Radiated emission (Fundamental and Spurious Emission) ........................................ 10 SECTION 6: -26dB Bandwidth ............................................................................................................ 12 SECTION 7: 99% Occupied Bandwidth ............................................................................................. 12 APPENDIX 1: Photographs of test setup ............................................................................................ 13 Radiated Emission ............................................................................................................................. 13 Worst Case Position .......................................................................................................................... 14 APPENDIX 2: Data of EMI test........................................................................................................... 16 Radiated Emission below 30MHz (Fundamental and Spurious Emission) ................................. 16 Radiated Emission above 30MHz (Spurious Emission) ................................................................. 17 -26dB Bandwidth and 99% Occupied Bandwidth ......................................................................... 18 APPENDIX 3: Test instruments .......................................................................................................... 19 Test report No. : 31BE0219-HO-12-B Page : 3 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 SECTION 1: Customer information Company Name : Mitsubishi Electric Corporation Himeji works Address : 840 Chiyoda-machi Himeji Hyogo, 670-8677, Japan Telephone Number : +81-79-298-8994 Facsimile Number : +81-79-298-9929 Contact Person : Toshio Koga SECTION 2: Equipment under test (E.U.T.) 2.1 Identification of E.U.T. Type of Equipment : Keyless System SSU Model No. : SKE133-01 Serial No. : Refer to Clause 4.2 Rating : DC 12.0V Receipt Date of Sample : February 1, 2011 Country of Mass-production : Japan Condition of EUT : Production prototype (Not for Sale: This sample is equivalent to mass-produced items.) Modification of EUT : No Modification by the test lab 2.2 Product Description Model No: SKE133-01 (referred to as the EUT in this report) is the Keyless System SSU. Feature of EUT The Keyless Entry System installed in vehicles. The lock or unlock of the door push the switch on the door, the transmitter starts communication between LF control unit (LFU) and a receiver and opens and closes the key of the door, and the engine start is possible. It can also lock or unlock the doors by operating the button on the transmitter. General Specification Clock frequency in the system : (CPU) 8MHz, 16MHz Radio Specification Radio Type : Transmitter Frequency of Operation : 125kHz Modulation : ASK Method of Frequency Genenration : Crystal Antenna type : Inductive loop Duty Cycle : Very Low Operating temperature range : -40 to +85 deg. C Test report No. : 31BE0219-HO-12-B Page : 4 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 SECTION 3: Test specification, procedures & results 3.1 Test Specification Test Specification : FCC Part 15 Subpart C: 2010, final revised on December 6, 2010 and effective January 5, 2011 Title : FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators Section 15.209 Radiated emission limits, general requirements Test report No. : 31BE0219-HO-12-B Page : 5 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 3.2 Procedures and results No. Item Test Procedure Specification RemarksDeviation Worst marginResults 1 Conducted Emission <FCC> ANSI C63.4:2003 7. AC powerline conducted emission measurements <IC> RSS-Gen 7.2.4 <FCC> Section 15.207 <IC> RSS-Gen 7.2.4 - N/A *1) N/A N/A 2 Electric Field Strength of Fundamental Emission <FCC> ANSI C63.4:2003 13. Measurement of intentional radiators <IC> RSS-Gen 4.8, 4.11 <FCC> Section 15.209 <IC> RSS-210 2.5.1 RSS-Gen 7.2.5 Radiated N/A 20.1dB 0.12500Hz, AV Complied 3 Electric Field Strength of Spurious Emission <FCC> ANSI C63.4:2003 13. Measurement of intentional radiators <IC> RSS-Gen 4.9, 4.11 <FCC> Section 15.209 <IC> RSS-210 2.5.1 RSS-Gen 7.2.5 Radiated N/A 7.7dB 35.756MHz, Vertical, QP Complied 4 -26dB Bandwidth <FCC> ANSI C63.4:2003 13. Measurement of intentional radiators <IC> - <FCC> Reference data <IC> - Radiated N/A N/A N/A Note: UL Japan, Inc.’s EMI Work Procedures No.QPM05 and QPM15. *1) The test is not applicable since the EUT is not the device that is designed to be connected to the public utility (AC) power line. FCC 15.31 (e) This test was performed with the New Battery (DC 12.0V) and the constant voltage was supplied to this EUT during the tests. Therefore, this EUT complies with the requirement. FCC Part 15.2…

Text truncated - open the document above for the full version.

Test Report

Test report No. : 31BE0219-HO-12-A Page : 2 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 CONTENTS PAGE SECTION 1: Customer information ..................................................................................................... 3 SECTION 2: Equipment under test (E.U.T.) ........................................................................................ 3 SECTION 3: Test specification, procedures & results ........................................................................ 4 SECTION 4: Operation of E.U.T. during testing ................................................................................. 8 SECTION 5: Radiated emission (Fundamental and Spurious Emission) ........................................ 10 SECTION 6: -26dB Bandwidth ............................................................................................................ 12 SECTION 7: 99% Occupied Bandwidth ............................................................................................. 12 APPENDIX 1: Photographs of test setup ............................................................................................ 13 Radiated Emission ............................................................................................................................. 13 Worst Case Position .......................................................................................................................... 14 APPENDIX 2: Data of EMI test........................................................................................................... 16 Radiated Emission below 30MHz (Fundamental and Spurious Emission) ................................. 16 Radiated Emission above 30MHz (Spurious Emission) ................................................................. 17 -26dB Bandwidth and 99% Occupied Bandwidth ......................................................................... 18 APPENDIX 3: Test instruments .......................................................................................................... 19 Test report No. : 31BE0219-HO-12-A Page : 3 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 SECTION 1: Customer information Company Name : Mitsubishi Electric Corporation Himeji works Address : 840 Chiyoda-machi Himeji Hyogo, 670-8677, Japan Telephone Number : +81-79-298-8994 Facsimile Number : +81-79-298-9929 Contact Person : Toshio Koga SECTION 2: Equipment under test (E.U.T.) 2.1 Identification of E.U.T. Type of Equipment : Keyless System SSU Model No. : SKE133-01 Serial No. : Refer to Clause 4.2 Rating : DC 12.0V Receipt Date of Sample : February 1, 2011 Country of Mass-production : Japan Condition of EUT : Production prototype (Not for Sale: This sample is equivalent to mass-produced items.) Modification of EUT : No Modification by the test lab 2.2 Product Description Model No: SKE133-01 (referred to as the EUT in this report) is the Keyless System SSU. Feature of EUT The Keyless Entry System installed in vehicles. The lock or unlock of the door push the switch on the door, the transmitter starts communication between LF control unit (LFU) and a receiver and opens and closes the key of the door, and the engine start is possible. It can also lock or unlock the doors by operating the button on the transmitter. General Specification Clock frequency in the system : (CPU) 8MHz, 16MHz Radio Specification Radio Type : Transmitter Frequency of Operation : 125kHz Modulation : ASK Method of Frequency Genenration : Crystal Antenna type : Inductive Duty Cycle : Very Low Operating temperature range : -40 to +85 deg. C Test report No. : 31BE0219-HO-12-A Page : 4 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 SECTION 3: Test specification, procedures & results 3.1 Test Specification Test Specification : FCC Part 15 Subpart C: 2010, final revised on December 6, 2010 and effective January 5, 2011 Title : FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators Section 15.209 Radiated emission limits, general requirements Test report No. : 31BE0219-HO-12-A Page : 5 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 3.2 Procedures and results No. Item Test Procedure Specification RemarksDeviation Worst marginResults 1 Conducted Emission <FCC> ANSI C63.4:2003 7. AC powerline conducted emission measurements <IC> RSS-Gen 7.2.4 <FCC> Section 15.207 <IC> RSS-Gen 7.2.4 - N/A *1) N/A N/A 2 Electric Field Strength of Fundamental Emission <FCC> ANSI C63.4:2003 13. Measurement of intentional radiators <IC> RSS-Gen 4.8, 4.11 <FCC> Section 15.209 <IC> RSS-210 2.5.1 RSS-Gen 7.2.5 Radiated N/A 16.7dB 0.12500MHz, AV Complied 3 Electric Field Strength of Spurious Emission <FCC> ANSI C63.4:2003 13. Measurement of intentional radiators <IC> RSS-Gen 4.9, 4.11 <FCC> Section 15.209 <IC> RSS-210 2.5.1 RSS-Gen 7.2.5 Radiated N/A 2.0dB 35.253MHz, Vertical, QP Complied 4 -26dB Bandwidth <FCC> ANSI C63.4:2003 13. Measurement of intentional radiators <IC> - <FCC> Reference data <IC> - Radiated N/A N/A N/A Note: UL Japan, Inc.’s EMI Work Procedures No.QPM05 and QPM15. *1) The test is not applicable since the EUT is not the device that is designed to be connected to the public utility (AC) power line. FCC 15.31 (e) This test was performed with the New Battery (DC 12.0V) and the constant voltage was supplied to this EUT during the tests. Therefore, this EUT complies with the requirement. FCC Part 15.203 A…

Text truncated - open the document above for the full version.

Test Report

Test report No. : 31BE0219-HO-12-B Page : 16 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 2: Data of EMI test Radiated Emission below 30MHz (Fundamental and Spurious Emission) DATA OF RADIATED EMISSION TEST UL Japan, Inc. Head Office EMC Lab. No.4 Semi Anechoic Chamber Date : 2011/02/03 Company : MITSUBISHI ELECTRIC CORPORATION HIME Report No. : 31BE0219-HO-12 Kind of EUT : Keyless System(SSU) Power : DC 3.0V Model No. : SKE133-02(Imobillizer) Temp./ Humi. : 21deg. C. /31% Serial No. : - Engineer : Hiroyuki Furutaka Mode / Remarks : Tx 125kHz Worst Axis(ECU:X-axis Antenna:X-axis) LIMIT : FCC15.209(a) 3m, 9-90kHz:PK, 110-490kHz:PK, other:QP FCC15.209(a) 3m, 9-90kHz:AV, 110-490kHz:AV, other:QP CHART: WITH FACTOR , ANT TYPE: LOOP , Except for the data below : adequate margin data below the limits. CALCULATION : RESULT[dBuV] = READING[dBuV] + ANT FACTOR[dB] + LOSS[dB]( CABLE + ATTEN.- AMP.) Frequency[Hz] [dBuV/m]<< QP/AV/PEAK DATA >> 90 deg:C 45 deg:B 0 deg:A 30M.01M.02M.03M.05M.07M.1M.2M.3M.5M.7M1M2M3M5M7M10M20M 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Freq.Reading DET Ant.FacLossGainResultLimitMarginAntenna Table Comment Freq.Reading DET Ant.FacLossGainResultLimitMarginAntenna Table Comment [MHz][dBuV] DET [dB/m][dB][dB][dBuV/m][dBuV/m][dB][deg] [deg] Comment 0.1250093.5PEAK20.15.932.187.4125.738.30A7Worst 0.1250091.9PEAK20.15.932.185.8125.739.945B336 0.1250088.9PEAK20.15.932.182.8125.742.990C281 0.1250090.7PEAK20.15.932.184.6125.741.1135C20 0.1250087.1AV20.15.932.181.0105.724.790C281 0.1250088.9AV20.15.932.182.8105.722.9135C20 0.1250090.0AV20.15.932.183.9105.721.845B336 0.1250091.7AV20.15.932.185.6105.720.10A7Worst 0.1250085.2PEAK20.15.932.179.1125.746.60C359Hori 0.1250083.4AV20.15.932.177.3105.728.40C359Hori 0.2500019.0PEAK20.06.00.045.0119.774.70A353 0.250000.0AV20.06.00.026.099.773.70A353 0.3750023.0PEAK19.96.00.048.9116.167.20A7 0.3750019.3AV19.96.00.045.296.150.90A7 0.500001.3QP19.96.00.027.273.646.40A8 0.6250012.3QP19.96.00.038.271.733.50A6 0.750000.8QP19.96.00.026.770.143.40A10 0.875007.6QP19.96.00.033.568.735.20A352 1.000000.7QP19.96.00.026.667.641.00A11 1.125005.0QP19.96.10.031.066.535.50A6 1.250000.6QP19.96.10.026.665.639.00A7 *The test result is rounded off to one or two decimal places, so some differences might be observed. RH Test report No. : 31BE0219-HO-12-B Page : 17 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Radiated Emission above 30MHz (Spurious Emission) DATA OF RADIATED EMISSION TEST UL Japan, Inc. Head Office EMC Lab. No.4 Semi Anechoic Chamber Date : 2011/02/03 Company : MITSUBISHI ELECTRIC CORPORATION HIME Report No. : 31BE0219-HO-12 Kind of EUT : Keyless System(SSU) Power : DC 3.0V Model No. : SKE133-02(Imobillizer) Temp. / Humi. : 23deg. C. / 30% Serial No. : - Engineer : Keisuke Kawamura Mode / Remarks : Tx 125kHz Worst-Axis (ECU Hori:X,Vert:X , Antenna Hori:Z,Vert:Z) LIMIT : FCC15.209 3m, below 1GHz:QP, above 1GHz:PK All other spurious emissions were less than 20dB for the limit. CHART:WITH FACTOR ANT TYPE: -30MHz:LOOP, 30-300MHz:BICONICAL, 300MHz-1000MHz:LOGPERIODIC, 1000MHz-:HORN CALCULATION:RESULT = READING + ANT FACTOR + LOSS(CABLE+ATTEN.) - GAIN(AMP) Frequency[Hz] [dBuV/m]<< QP DATA >> Horizontal Vertical Horizontal Vertical 30M1G50M70M100M200M300M500M700M 0 10 20 30 40 50 60 70 80 FrequencyReading DET AntennaLoss& LevelAngleHeight Polar. LimitMargin Comment FrequencyReading DETFactorGain LevelAngleHeight Polar. LimitMargin Comment [MHz][dBuV] DET [dB/m][dB][dBuV/m][Deg][cm] Polar. [dBuV/m][dB] Comment 35.75622.9QP16.2-24.914.20300Hori.40.025.8 35.75641.0QP16.2-24.932.3252100Vert.40.07.7 112.02134.0QP12.0-23.922.1315285Hori.43.521.4 112.02133.9QP12.0-23.922.045100Vert.43.521.5 144.02524.4QP14.8-23.515.7237231Hori.43.527.8 144.02528.0QP14.8-23.519.3264100Vert.43.524.2 244.04927.5QP17.3-22.622.2216100Vert.46.023.8 244.04928.2QP17.3-22.622.938197Hori.46.023.1 295.08521.8QP19.3-22.318.80100Vert.46.027.2 295.08521.8QP19.3-22.318.80300Hori.46.027.2 392.07429.7QP17.4-21.625.5292100Hori.46.020.5 392.07428.6QP17.4-21.624.4257107Vert.46.021.6 *The test result is rounded off to one or two decimal places, so some differences might be observed. RH Test report No. : 31BE0219-HO-12-B Page : 18 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 -26dB Bandwidth and 99% Occupied Bandwidth UL Japan, Inc. Head Office EMC Lab. No.4 Semi Anechoic Chamber COMPANY : MITSUBISHI ELECTRIC CORPOR AREPORT NO : 31BE0219-HO-12 EQUIPMENT : Keyless System(SSU) MODEL : SKE133-02TEST DISTANCE : 3m S/ N : -DATE : 02/02/2011 POWER : DC 12.0VTEMPERATURE : 21 deg.C MODE : TxHUMIDITY : 31 % Engineer: Hiroyuki Furutaka FREQ -26dB Bandwidth [kHz] 125.026.651 [kHz] 24.108 99% Occupied Bandwidth [kHz] RH Test report No. : 31BE0219-HO-12-B Page : 19 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 3: Test instruments EMI test equipment Control No. Instrument Manufacturer Model No Serial No Test Item Calibration Date * Interval(month) MAEC-04 Semi Anechoic Chamber(NSA) TDK Semi Anechoic Chamber 3m DA-10005 RE 2010/02/02 * 12 MOS-15 Thermo-Hygrometer Custom CTH-180 - RE 2010/02/09 * 12 MJM-07 Measure PROMART SEN1955 - RE - COTS-MEMI EMI measurement program TSJ TEPTO-DV - RE - MSA-05 Spectrum Analyzer Advantest R3273 160400285 RE 2010/11/18 * 12 MTR-07 Test Receiver Rohde & Schwarz ESCI 100635 RE 2010/10/27 * 12 MLPA-02 Loop Antenna Rohde & Schwarz HFH2-Z2 836553/009 RE 201…

Text truncated - open the document above for the full version.

Test Report

Test report No. : 31BE0219-HO-12-A Page : 16 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 2: Data of EMI test Radiated Emission below 30MHz (Fundamental and Spurious Emission) DATA OF RADIATED EMISSION TEST UL Japan, Inc. Head Office EMC Lab. No.4 Semi Anechoic Chamber Date : 2011/02/02 Company : MITSUBISHI ELECTRIC CORPORATION HIME Report No. : 31BE0219-HO-04 Kind of EUT : Keyless System(SSU) Power : DC 3.0V Model No. : SKE133-01(LF) Temp./ Humi. : 21deg. C. /31% Serial No. : Q101110 Engineer : Hiroyuki Furutaka Mode / Remarks : Tx 125kHz Worst Axis(ECU:X-axis Antenna:X-axis) LIMIT : FCC15.209(a) 3m, 9-90kHz:PK, 110-490kHz:PK, other:QP FCC15.209(a) 3m, 9-90kHz:AV, 110-490kHz:AV, other:QP CHART: WITH FACTOR , ANT TYPE: LOOP , Except for the data below : adequate margin data below the limits. CALCULATION : RESULT[dBuV] = READING[dBuV] + ANT FACTOR[dB] + LOSS[dB]( CABLE + ATTEN.- AMP.) Frequency[Hz] [dBuV/m]<< QP/AV/PEAK DATA >> 90 deg:C 45 deg:B 0 deg:A 30M.01M.02M.03M.05M.07M.1M.2M.3M.5M.7M1M2M3M5M7M10M20M 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Freq.Reading DET Ant.FacLossGainResultLimitMarginAntennaTable Comment Freq.Reading DET Ant.FacLossGainResultLimitMarginAntennaTable Comment [MHz][dBuV] DET [dB/m][dB][dB][dBuV/m][dBuV/m][dB][deg][deg] Comment 0.12500107.5PEAK20.15.932.1101.4125.724.30A7Worst 0.12500106.2PEAK20.15.932.1100.1125.725.645B325 0.12500102.9PEAK20.15.932.196.8125.728.990C277 0.12500105.0PEAK20.15.932.198.9125.726.8135C22 0.1250092.4AV20.15.932.186.3105.719.4135C32 0.1250090.6AV20.15.932.184.5105.721.290C277 0.1250094.0AV20.15.932.187.9105.717.845B325 0.1250095.1AV20.15.932.189.0105.716.70A7Worst 0.1250099.4PEAK20.15.932.193.3125.732.40A359Hori 0.1250087.2AV20.15.932.181.1105.724.60A359Hori 0.2500012.4PEAK20.06.00.038.4119.781.30A197 0.250004.2AV20.06.00.030.299.769.50A197 0.3750035.2PEAK19.96.00.061.1116.155.00A1 0.3750021.2AV19.96.00.047.196.149.00A1 0.500001.6QP19.96.00.027.573.646.10A7 0.6250018.7QP19.96.00.044.671.727.10A8 0.750000.8QP19.96.00.026.770.143.40A7 0.875006.2QP19.96.00.032.168.736.60A3 1.000000.9QP19.96.00.026.867.640.80A7 1.125001.0QP19.96.10.027.066.539.50A5 1.250001.1QP19.96.10.027.165.638.50A7 *The test result is rounded off to one or two decimal places, so some differences might be observed. RH 31BE0219-HO-12 Test report No. : 31BE0219-HO-12-A Page : 17 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Radiated Emission above 30MHz (Spurious Emission) DATA OF RADIATED EMISSION TEST UL Japan, Inc. Head Office EMC Lab. No.4 Semi Anechoic Chamber Date : 2011/02/03 Company : MITSUBISHI ELECTRIC CORPORATION HIME Report No. : 31BE0219-HO-12 Kind of EUT : Keyless System(SSU) Power : DC 3.0V Model No. : SKE133-02(LF) Temp. / Humi. : 23deg. C. / 30% Serial No. : - Engineer : Keisuke Kawamura Mode / Remarks : Tx 125kHz Worst-Axis (ECU Hori:Z,Vert:Z , Antenna HoriX,Vert:X) LIMIT : FCC15.209 3m, below 1GHz:QP, above 1GHz:PK All other spurious emissions were less than 20dB for the limit. CHART:WITH FACTOR ANT TYPE: -30MHz:LOOP, 30-300MHz:BICONICAL, 300MHz-1000MHz:LOGPERIODIC, 1000MHz-:HORN CALCULATION:RESULT = READING + ANT FACTOR + LOSS(CABLE+ATTEN.) - GAIN(AMP) Frequency[Hz] [dBuV/m]<< QP DATA >> Horizontal Vertical Horizontal Vertical 30M1G50M70M100M200M300M500M700M 0 10 20 30 40 50 60 70 80 FrequencyReading DET AntennaLoss& LevelAngleHeight Polar. LimitMargin Comment FrequencyReading DETFactorGain LevelAngleHeight Polar. LimitMargin Comment [MHz][dBuV] DET [dB/m][dB][dBuV/m][Deg][cm] Polar. [dBuV/m][dB] Comment 36.75927.3QP15.8-24.918.279400Hori.40.021.8 35.25346.5QP16.4-24.938.0228100Vert.40.02.0 58.75844.9QP8.8-24.629.1359363Hori.40.010.9 58.75844.1QP8.8-24.628.3249100Vert.40.011.7 81.51441.4QP6.8-24.423.8260100Vert.40.016.2 81.76442.4QP6.9-24.424.9194229Hori.40.015.1 173.51129.2QP15.9-23.221.9322187Hori.43.521.6 173.51130.7QP15.9-23.223.493100Vert.43.520.1 295.08521.8QP19.3-22.318.80300Hori.46.027.2 295.08521.8QP19.3-22.318.80100Vert.46.027.2 391.70221.9QP17.4-21.617.70100Vert.46.028.3 391.70221.9QP17.4-21.617.70100Hori.46.028.3 *The test result is rounded off to one or two decimal places, so some differences might be observed. RH Test report No. : 31BE0219-HO-12-A Page : 18 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 -26dB Bandwidth and 99% Occupied Bandwidth UL Japan, Inc. Head Office EMC Lab. No.4 Semi Anechoic Chamber COMPANY : MITSUBISHI ELECTRIC CORPO RREPORT NO : 31BE0219-HO-12 EQUIPMENT : Keyless System(SSU) MODEL : SKE133-01TEST DISTANCE : 3m S/ N : Q101110DATE : 02/02/2011 POWER : DC 12.0VTEMPERATURE : 21 deg.C MODE : TxHUMIDITY : 31 % Engineer: Hiroyuki Furutaka FREQ -26dB Bandwidth [kHz] 125.013.002 [kHz] 12.092 99% Occupied Bandwidth [kHz] RH Test report No. : 31BE0219-HO-12-A Page : 19 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 3: Test instruments EMI test equipment Control No. Instrument Manufacturer Model No Serial No Test Item Calibration Date * Interval(month) MAEC-04 Semi Anechoic Chamber(NSA) TDK Semi Anechoic Chamber 3m DA-10005 RE 2010/02/02 * 12 MOS-15 Thermo-Hygrometer Custom CTH-180 - RE 2010/02/09 * 12 MJM-07 Measure PROMART SEN1955 - RE - COTS-MEMI EMI measurement program TSJ TEPTO-DV - RE - MSA-05 Spectrum Analyzer Advantest R3273 160400285 RE 2010/11/18 * 12 MTR-07 Test Receiver Rohde & Schwarz ESCI 100635 RE 2010/10/27 * 12 MLPA-02 Loop Antenna Rohde & Schwarz HFH2-Z2 836553/009 RE 2010/12…

Text truncated - open the document above for the full version.

Test Setup Photos

Test report No. : 31BE0219-HO-12-B Page : 13 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 1: Photographs of test setup Radiated Emission Photo 1 Photo 2 Test report No. : 31BE0219-HO-12-B Page : 14 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Worst Case Position Ant Below30MHz: X-axis Above30MHz Hori:Z / Vert:Z ECU Below30MHz: X-axis Above30MHz Hori:X / Vert:X X-axis X-axis Y-axis Y-axis Z-axis Z-axis Test report No. : 31BE0219-HO-12-B Page : 15 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 4.3 Configuration and peripherals * Cabling and setup were taken into consideration and test data was taken under worse case conditions. Description of EUT and Support equipment No. Item Model number Serial number Manufacturer Remarks A LF antenna - LF ANT Mitsubishi Electric Corporation Himeji works - B Antenna coil (Immobilizer) - 001 - EUT C Keyless System SSU SKE133-01 20110131-S1 Mitsubishi Electric Corporation Himeji works EUT D SW Box 1 - - Mitsubishi Electric Corporation Himeji works - List of cables used No. Name Length (m) Shield Remark Cable Connector 1 Antenna Cable 1.2 Unshielded Unshielded - 2 Antenna Cable 1.2 Unshielded Unshielded - 3 Signal Cable 0.8 Unshielded Unshielded - 4 DC Cable 1.1 Unshielded Unshielded - C DC12.0V D A B 1 2 3 4

Test Setup Photos

Test report No. : 31BE0219-HO-12-A Page : 13 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 1: Photographs of test setup Radiated Emission Photo 1 Photo 2 Test report No. : 31BE0219-HO-12-A Page : 14 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Worst Case Position Ant Below30MHz: X-axis Above30MHz Hori:X / Vert:X ECU Below30MHz: X-axis Above30MHz Hori:Z / Vert:Z X-axis X-axis Y-axis Y-axis Z-axis Z-axis Test report No. : 31BE0219-HO-12-A Page : 15 of 19 Issued date : March 22, 2011 FCC ID : WAZSKE13301 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 4.2 Configuration and peripherals * Cabling and setup were taken into consideration and test data was taken under worse case conditions. Description of EUT and Support equipment No. Item Model number Serial number Manufacturer Remarks A LF antenna - LF ANT Mitsubishi Electric Corporation Himeji works EUT B Antenna coil (Immobilizer) - 001 - - C Keyless System SSU SKE133-01 20110131-S1 Mitsubishi Electric Corporation Himeji works EUT D SW Box 1 - - Mitsubishi Electric Corporation Himeji works - List of cables used No. Name Length (m) Shield Remark Cable Connector 1 Antenna Cable 1.2 Unshielded Unshielded - 2 Antenna Cable 1.2 Unshielded Unshielded - 3 Signal Cable 0.8 Unshielded Unshielded - 4 DC Cable 1.1 Unshielded Unshielded - C DC12.0V D A B 4 3 1 2

Contact Information

Applicant

Tomoko Masuda
[email protected]+81-79-298-9795Fax: +81-79-298-9913

Technical Contact

UL Japan, Inc.Shinya Watanabe
[email protected]81-596-24-8116

4383-326 Asama-cho, Ise-shi · Mie-ken · Japan

Test Firm

UL Japan, Inc. Head office EMC Lab.Tetsuya Hashimoto
[email protected]+81-596-24-8116Fax: +81-596-24-8095

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.125 MHz - 0.125 MHz-
Confidentiality
Long Term

Other Applications from Mitsubishi Electric Corporation Himeji works

Smart Keyless System Smart Unit - FCC ID WAZSKEA7D05 - Mitsubishi Electric Corporation Himeji works
WAZSKEA7D05

Smart Keyless System Smart Unit

Sep 25, 2023

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
Smart Keyless System Smart Unit - FCC ID WAZSKEA7D06 - Mitsubishi Electric Corporation Himeji works
WAZSKEA7D06

Smart Keyless System Smart Unit

Aug 27, 2023

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
WAZSKE8AD03

Smart Keyless System (Smart Unit)

Jul 19, 2022

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
Smart Keyless System Smart Unit - FCC ID WAZSKE45A03 - Mitsubishi Electric Corporation Himeji works
WAZSKE45A03

Smart Keyless System Smart Unit

Dec 24, 2020

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
Keyless System Hand Unit - FCC ID WAZSKE13D02 - Mitsubishi Electric Corporation Himeji works
WAZSKE13D02

Keyless System Hand Unit

Dec 14, 2015

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter