Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ใ Confidential ใ The following contents are described in Owners Manual of the vehicle. In Canada, it is described in English and French. FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the userโs authority to operate the equipment. FCC/IC This device complies with Part 15 of FCC Rules and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of this device. Le prรฉsent appareil est conforme aux la Partie 15 des rรจgles de la FCC et CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisรฉe aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioรฉlectrique subi, mรชme si le brouillage est susceptible d'en compromettre le fonctionnement. Users manual FCC&IC.xls
ใ Confidential ใ Model ๏ผ SKE13D-01 TOP LEFT FACE RIGHT BACK BOTTOM Keyless System (Hand Unit) PHOTO_6_Hand Unit(Transmitter)_SKE13D01.xls
ใ Confidential ใ Model ๏ผ SKE13D-01 3SW 4SW 5 SW Laser marking ๏ผ Switch variation do not affect the RF characteristic 2 SW Switch variation * Label display ๏ผ Rear) Keyless System Hand Unit (Transmitter) Label FCC ID ๏ผ WAZSKE13D01 IC ๏ผ 662F-SKE13D01 MODEL ๏ผ SKE13D-01 MITSUBISHI ELECTRIC CORPORATION Label_Hand Unit(Transmitter)_SKE13D01.xls
ใ Confidential ใ Model ๏ผ SKE13D-01 FACE BACK Keyless System (Hand Unit) PHOTO_PCB_ASSY_Hand Unit(Transmitter)_SKE13D01.xls
Test report No. : 31BE0219-HO-08-B-R1 Page : 13 of 19 Issued date : March 22, 2011 Revised date : March 28, 2011 FCC ID : WAZSKE13D01 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 2: Data of EMI test Automatically deactivate Test place Head Office EMC Lab. No.2 Semi Anechoic Chamber Report No. 31BE0219-HO-08 Date 02/09/2011 Temperature/ Humidity 24 deg.C./ 31%RH Engineer Motoya Imura Mode Normal use mode Time of Transmitting [sec] Limit [sec] Result 0.35 5.00 Pass Test report No. : 31BE0219-HO-08-B-R1 Page : 14 of 19 Issued date : March 22, 2011 Revised date : March 28, 2011 FCC ID : WAZSKE13D01 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission) Test place Head Office EMC Lab. No.2 Semi Anechoic Chamber Report No. 31BE0219-HO-08 Date 02/09/2011 Temperature/ Humidity 24 deg.C./ 31%RH Engineer Motoya Imura Mode Transmitting mode PK FrequencyDetectorAntLossGainDutyLimitRemark FactorFactorInside or Outside [MHz]HorVer[dB/m][dB][dB][dB]HorVer[dBuV/m ]HorVerof Restricted Bands 315.000 PK84.379.615.48.827.8-80.776.095.614.919.6 Carrier 630.000 PK37.236.619.710.228.6-38.537.975.637.137.7 Outside 945.000 PK35.233.122.611.327.8-41.339.275.634.336.4 Outside 1260.000 PK51.154.724.72.333.4-44.748.375.630.927.3 Outside 1575.000 PK56.158.525.72.633.0-51.453.873.922.520.1 Inside 1890.000 PK51.049.526.52.832.6-47.746.275.627.929.4 Outside 2205.000 PK52.551.927.12.932.5-50.049.473.923.924.5 Inside 2520.000 PK55.751.627.63.132.4-54.049.975.621.625.7 Outside 2835.000 PK56.953.228.13.332.4-55.952.273.918.021.7 Inside 3150.000 PK48.046.928.63.432.2-47.846.775.627.828.9 Outside Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter) - Gain(Amprifier) PK with Duty factor FrequencyDetectorAntLossGainDutyLimitRemark FactorFactor [MHz]HorVer[dB/m][dB][dB][dB]HorVer[dBuV/m ]HorVer 315.000 PK84.379.615.48.827.8-5.874.970.275.60.75.4 Carrier 630.000 PK37.236.619.710.228.6-5.832.732.155.622.923.5 Outside 945.000 PK35.233.122.611.327.8-5.835.533.455.620.122.2 Outside 1260.000 PK51.154.724.72.333.4-5.838.942.555.616.713.1 Outside 1575.000 PK56.158.525.72.633.0-5.845.648.053.98.35.9 Inside 1890.000 PK51.049.526.52.832.6-5.841.940.455.613.715.2 Outside 2205.000 PK52.551.927.12.932.5-5.844.243.653.99.710.3 Inside 2520.000 PK55.751.627.63.132.4-5.848.244.155.67.411.5 Outside 2835.000 PK56.953.228.13.332.4-5.850.146.453.93.87.5 Inside 3150.000 PK48.046.928.63.432.2-5.842.040.955.613.614.7 Outside Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter) - Gain(Amprifier) + Duty factor (Refer to Duty factor data sheet) *Other frequency noises omitted in this report were not seen or had enough margin (more than 20dB). Result [dBuV/m] Margin [dB] ReadingResult [dBuV][dBuV/m] Margin [dB] Reading [dBuV] * The test was performed with PK detect. Average emission measurements were calculated with PK detect and Duty cycle factor. * Duty Factor was calculated with the assumption of the worst condition in 100msec. * All the measured noise was pulse emission. Test report No. : 31BE0219-HO-08-B-R1 Page : 15 of 19 Issued date : March 22, 2011 Revised date : March 28, 2011 FCC ID : WAZSKE13D01 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 -20dB and 99% Occupied Bandwidth Test place Head Office EMC Lab. No.2 Semi Anechoic Chamber Report No. 31BE0219-HO-08 Date 02/09/2011 Temperature/ Humidity 24 deg.C./ 31%RH Engineer Motoya Imura Mode Transmitting mode Bandwidth Limit : Fundamental Frequency 315MHz x 0.25% = 787.50kHz -20dB BandwidthResult [kHz] 161.05Pass 99% Occupied BandwidthResult [kHz] 222.84Pass [kHz] 787.50 Bandwidth Limit [kHz] 787.50 Bandwidth Limit Test report No. : 31BE0219-HO-08-B-R1 Page : 16 of 19 Issued date : March 22, 2011 Revised date : March 28, 2011 FCC ID : WAZSKE13D01 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Duty Cycle Test place Head Office EMC Lab. No.2 Semi Anechoic Chamber Report No. 31BE0219-HO-08 Date 02/09/2011 Temperature/ Humidity 22 deg.C./ 31%RH Engineer Motoya Imura Mode Normal use mode ON time(One pulse)ON time(in 30ms) TypeTimes[ms][ms] A630.1328.316 B220.2535.566 C40.3771.508 *1)ON time(in 30ms) = Times * ON time(One pulse) *2)The train of pulses was exceeding 100msec, and that sampled 100msec was the worst case against the pul s (Total) ON timeCycleDutyDuty [ms][ms](On time/Cycle)[dB] 51.30100.000.51-5.8 *3)ON time = Type A's ON time (in 100ms) + Type B's ON time (in 100ms)+TypeC's ON time *4)Duty = 20log 10 (ON time/Cycle) Test report No. : 31BE0219-HO-08-B-R1 Page : 17 of 19 Issued date : March 22, 2011 Revised date : March 28, 2011 FCC ID : WAZSKE13D01 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Duty Cycle 2ms 30ms ๏ผ Type A ๏ผ Type B : Type C Test report No. : 31BE0219-HO-08-B-R1 Page : 18 of 19 Issued date : March 22, 2011 Revised date : March 28, 2011 FCC ID : WAZSKE13D01 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Duty Cycle 50ms 100ms Test report No. : 31BE0219-HO-08-B-R1 Page : 19 of 19 Issued date : March 22, 2011 Revised date : March 28, 2011 FCC ID : WAZSKE13D01 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 3:Test Instruments EMI test equipment Control No. Instrument Manufacturer Model No Serial No Test Item Calibration Date * Interval(month) MAEC-03 Semi Anechoic Chamber(NSA) TDK Semi Anechoic Chamber 3m Dโฆ
Text truncated - open the document above for the full version.
Test report No. : 31BE0219-HO-08-B-R1 Page : 2 of 19 Issued date : March 22, 2011 Revised date : March 28, 2011 FCC ID : WAZSKE13D01 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 CONTENTS PAGE SECTION 1: Customer information ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 SECTION 2: Equipment under test (E.U.T.) ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 SECTION 3: Test specification, procedures & results ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 SECTION 4: Operation of E.U.T. during testing ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 SECTION 5: Radiated emission (Electric Field Strength of Fundamental and Spurious Emission) 8 SECTION 6: Automatically deactivate ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 SECTION 7: -20dB and 99% Occupied Bandwidth ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 APPENDIX 1: Photographs of test setup ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 10 Radiated emission ............................................................................................................................. 10 Worst case position ........................................................................................................................... 11 APPENDIX 2: Data of EMI test ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 13 Automatically deactivate .................................................................................................................. 13 Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission) ..................... 14 -20dB and 99% Occupied Bandwidth ............................................................................................... 15 Duty Cycle ........................................................................................................................................ 16 APPENDIX 3:Test Instruments ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 19 Test report No. : 31BE0219-HO-08-B-R1 Page : 3 of 19 Issued date : March 22, 2011 Revised date : March 28, 2011 FCC ID : WAZSKE13D01 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 SECTION 1: Customer information Company Name : Mitsubishi Electric Corporation Himeji works Address : 840 Chiyoda-machi Himeji Hyogo, 670-8677, Japan Telephone Number : +81-79-298-8994 Facsimile Number : +81-79-298-9929 Contact Person : Toshio Koga SECTION 2: Equipment under test (E.U.T.) 2.1 Identification of E.U.T. Type of Equipment : Keyless System Hand Unit Model No. : SKE13D-01 Serial No. : Refer to Clause 4.2 Rating : DC 3.0V Receipt Date of Sample : February 9, 2011 Country of Mass-production : Japan Condition of EUT : Production prototype (Not for Sale: This sample is equivalent to mass-produced items.) Modification of EUT : No Modification by the test lab 2.2 Product Description Model No: SKE13D-01 (referred to as the EUT in this report) is the Keyless System Hand Unit. Feature of EUT The Keyless Entry System installed in vehicles. When Lock and Unlock of the door push the switch in the door, the transmitter starts the LF control unit(LFU) and communication between the receiver and opens and closes the key of the door, and the engine start is possible. It can also lock or unlock the doors by operating the button on the transmitter. General Specification Clock frequency in the system : (RF IC) 9.84375MHz, (CPU) 615.2kHz Radio Specification Radio Type : Transmitter Frequency of Operation : 315MHz Modulation : FSK Method of Frequency Genenration : Crystal Antenna type : PCB Pattern Duty Cycle : Very Low Operating temperature range : -20 to +60 deg. C Test report No. : 31BE0219-HO-08-B-R1 Page : 4 of 19 Issued date : March 22, 2011 Revised date : March 28, 2011 FCC ID : WAZSKE13D01 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 SECTION 3: Test specification, procedures & results 3.1 Test Specification Test Specification : FCC Part 15 Subpart C: 2010, final revised on December 6, 2010 and effective January 5, 2011 Title : FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators Section 15.231 Periodic operation in the band 40.66 - 40.70MHz and above 70MHz 3.2 Procedures and results Item Test Procedure Specification Worst margin Results Remarks Conducted emission FCC: ANSI C63.4:2003 7. AC powerline conducted emission measurements FCC: Section 15.207 N/A N/A*1) - IC: RSS-Gen 7.2.2 IC: RSS-Gen 7.2.2 Automatically Deactivate FCC: ANSI C63.4:2003 13. Measurement of intentional radiators FCC: Section 15.231(a)(1) N/A Complied Radiated IC: - IC: RSS-210 A1.1.1 Electric Field Strength of Fundamental Emission FCC: ANSI C63.4:2003 13. Measurement of intentional radiators FCC: Section 15.231(b) 0.7dB 315.000MHz, Horizontal (PK with Duty factor) Complied Radiated IC: RSS-Gen 4.8 IC: RSS-210 A1.1.2 Electric Field Strength of Spurious Emission FCC: ANSI C63.4:2003 13. Measurement of intentional radiators FCC: Section 15.205 Section 15.209 Section 15.231(b) 3.8dB 2835.00MHz, Horizontal (PK with Duty factor) Complied Radiated IC: RSS-Gen 4.9 IC: RSS-210 A1.1.2, 2.6, 2.7 -20dB Bandwidth FCC: ANSI C63.4:2003 13. Measurement of intentional radiators FCC: Section 15.231(c) N/A Complied Radiated IC: - IC: Reference data Note: UL Japan, Inc.โs EMI Work Procedures No.QPM05 and QPM15. *1) The test is not applicable since the EUT does not have AC Mains. FCC 15.31 (e) This test was performed with the New Battery (DC 3.0V) and the constant voltage was supplied to the EUT during the tests. Therefore, the EUT complies with the requirement. FCC Part 15.203 Anโฆ
Text truncated - open the document above for the full version.
Test report No. : 31BE0219-HO-08-B-R1 Page : 10 of 19 Issued date : March 22, 2011 Revised date : March 28, 2011 FCC ID : WAZSKE13D01 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 1: Photographs of test setup Radiated emission Photo 1 Photo 2 Test report No. : 31BE0219-HO-08-B-R1 Page : 11 of 19 Issued date : March 22, 2011 Revised date : March 28, 2011 FCC ID : WAZSKE13D01 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Worst case position (Horizontal: X-axis/Vertical : Y-axis) X-axis Y-axis Z-axis Test report No. : 31BE0219-HO-08-B-R1 Page : 12 of 19 Issued date : March 22, 2011 Revised date : March 28, 2011 FCC ID : WAZSKE13D01 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Worst case position Mechanical Key (Not Inserted) Worst Mechanical Key (Inserted)
4383-326 Asama-cho, Ise-shi ยท Mie-ken ยท Japan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 315 MHz - 315 MHz | - |

Smart Keyless System Smart Unit
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Smart Keyless System Smart Unit
Equipment Class
CYY - Communications Receiver used w/Pt 15 TransmitterSmart Keyless System (Smart Unit)
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Smart Keyless System Smart Unit
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Keyless System Hand Unit
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter