Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
MiCard V3 Installation Manual (Full Install Guide) Versioning Versioning Version Author(s) Revision date Reviewer(s) 1.0 Thomas Lemmer WP Name MiCard V3 - Installation Manual Knowledge Base File Name MiCard_V3_Full_Installation_Guide_EN_V1.0.pdf Technologies concerned uniFLOW Login Manager/MomClient (Secure/Public Printing Applet) Short Summary This manual describes the features, the installation, and the configuration of the MiCard V3 Reader in detail. MiCard is a registered trademark of NT-ware Systemprogrammierung GmbH. Document changes Version Changes Disclaimer All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems - without the written permission of NT-ware Systemprogrammierung GmbH. Company and product names mentioned herein are registered or unregistered trademarks of their respective companies. Mention of third-party products is for information purposes only and constitutes neither an endorsement nor a recommendation. NT-ware assumes no responsibility with regard to the performance or use of these products. Also, NT-ware makes no claim to these trademarks. Any use of trademarks, logo, service marks, trade names, and product names is prohibited without the written permission of the respective owners. Adlib Software of Adlib Software; Adobe®, Adobe® Reader, Acrobat®, Distiller®, PostScript® and products of the CREATIVE SUITE(S) of Adobe Systems Incorporated; Apple®, the Apple® logo, Mac®, Mac OS®, Macintosh®, iPhone®, iPad® and AirPrint® of Apple Inc.; CANON, imageRUNNER, imageRUNNER ADVANCE, MEAP, CPCA, AMS, iW AMS, iW Desktop, iSend, iW SAM of Canon Inc.; Crystal Reports of Business Objects SA, as of July 1, 2008: BusinessObjects of SAP; eCopy™, eCopy ShareScan®, and eCopy ScanStation® of Nuance Communications, Inc.; Foxit Reader of Foxit Corporation; Google Docs of Google Inc.; Helix™ Production Workflow is a trademark of NT-ware Systemprogrammierung GmbH; Hewlett Packard, HP, LaserJet, and PCL of Hewlett-Packard Company; iOS® of Cisco Technology Inc.; I.R.I.S. Group s.a.; JAWS pdf courier™ are trademarks of Global Graphics SA.; Microsoft®, Windows®, Windows Vista®, Windows 7®, Internet Explorer®, Internet Information Server, Microsoft® Word, Microsoft® Excel, SQL Server® of Microsoft Corporation; Neevia Document Converter ProTM of Neevia Technology; NetWare, Novell®, Novell eDirectory® of Novell Inc.; OpenOffice.org™ of Oracle Corporation; PAS™ of Equitrac Corporation; PosterJet of Eisfeld Datentechnik GmbH & Co. KG; Red Titan EscapeE of Red Titan Limited; NETAPHOR ®, SiteAudit™ are trademarks of NETAPHOR SOFTWARE Inc.; Therefore™ of Therefore; UNIX® of The Open Group; uniFLOW OM®, uniFLOW®, uniFLOW Serverless Secure Printing®, MIND®, microMIND®, and MiCard® are registered trademarks of NT-ware Systemprogrammierung GmbH; pcProx®, AIR ID® are registered trademarks of RFIdeas Inc.Readers; CASI-RUSCO® is registered trademark of ID Card Group; Radio Key® is registered trademark of Secura Key; GProx™ II is unregistered trademark of Guardall; HID® ProxHID is registered trademark of HID Global Corporation; Indala® is registered trademark of Motorola; ioProx™ is unregistered trademark of Kantech. All other trademarks, trade names, product names, service marks are property of their respective owners and are hereby acknowledged. While every precaution has been taken in the preparation of this document, NT-ware assumes no responsibility for errors or omissions, or for damages resulting from the use of information contained in this document or from the use of programs and source code that may accompany it. NT-ware does not assume any responsibility or liability for any malfunctions or loss of data caused by the combination of at least of one NT-ware product and the used operation system and/or third-party products. In no event shall NT-ware be liable for any loss of profit or any other commercial damage caused or alleged to have been caused directly or indirectly by this document. In addition, this manual provides links to the sites of affiliated or independent companies and certain other businesses. NT-ware is not responsible for examining or evaluating, and NT-ware does not warrant the offerings of, any of these businesses or individuals or the content of their websites. NT-ware does not assume any responsibility or liability for the actions, product, and content of all these and any other third parties. You should carefully review their privacy statements and other conditions of use. PLEASE NOTE: Serious problems might occur if you modify the registry of your Windows operating system incorrectly. These problems might require that you reinstall the operating system. We strongly recommend to always back up the registry of your Windows operating system before applying changes to it, just in case you do something wrong. NT-ware does not assume any responsibility or liability for any impact on the operating system after changing the Registry. You understand and accept that you use this information and modify the registry of your Windows operating system at your own risk. Friday, October 26, 2012, Bad Iburg (Germany) Symbols Text Styles Text that appears in this style is used for screen text that appears in the uniFLOW user interface and on user interface controls. Text that appears in this style is used for User entries on screen, text that the user actually has to type in. Text that appears in this style is used for hyperlinks to an external web page, or internal links to other pages of this manual. Text that appears in this style is used for code examples: XML code, variables or regular expressions. Pictograms Important note: Information that is crucial for the correct functioning of the uniFLOW software. External manual: Pointer to additional manuals for third party hardware or third party software. Region Specific Feature: In cas…
Text truncated - open the document above for the full version.
ANNEX B:EXTERNAL PHOTOGRAPHS Examiner: Michael DINTER Test Report No.: F123762E3 Date of issue: 30 October 2012 Order No.: 12-113762 page 1 of 1 123762eut1 ANNEX B:EXTERNAL PHOTOGRAPHS Examiner: Michael DINTER Test Report No.: F123762E3 Date of issue: 30 October 2012 Order No.: 12-113762 page 2 of 2 123762eut2 ANNEX B:EXTERNAL PHOTOGRAPHS Examiner: Michael DINTER Test Report No.: F123762E3 Date of issue: 30 October 2012 Order No.: 12-113762 page 3 of 3 123762eut6
ANNEX C:INTERNAL PHOTOGRAPHS Examiner: Michael DINTER Test Report No.: F123762E3 Date of issue: 30 October 2012 Order No.: 12-113762 page 1 of 1 123762eut3 ANNEX C:INTERNAL PHOTOGRAPHS Examiner: Michael DINTER Test Report No.: F123762E3 Date of issue: 30 October 2012 Order No.: 12-113762 page 2 of 2 123762eut4 ANNEX C:INTERNAL PHOTOGRAPHS Examiner: Michael DINTER Test Report No.: F123762E3 Date of issue: 30 October 2012 Order No.: 12-113762 page 3 of 3 123762eut5
Königswinkel 10 32825 Blomberg Germany Phone +49 5235 9500-0 Fax +49 5235 9500-10 TEST REPORT Test Report Number: F123762E3 Applicant: NT-ware Systemprogrammierung GmbH Manufacturer: NT-ware Systemprogrammierung GmbH Equipment under Test: MiCard V3 / USB RF-Cardreader Version 1.00 Laboratory accredited by DGA Deutsche Gesellschaft für Akkreditierung mbH in compliance with DIN EN ISO/IEC 17025 Testengineer: Michael DINTER Report Number: F123762E3 Date of issue: 30 October 2012 Order Number: 12-113762 page 2 of 26 REFERENCES [1] ANSI C63.4:2009 American National Standard for Methods of Measuring of Radio-Noise Emissions from Low- Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. [2] FCC 47 CFR Part 2 General Rules and Regulations [3] RSS-210 Issue 8 (December 2010) Low-power Licence-exempt Radiocommunication Devices (All Frequency Bands): Category I Equipment [4] RSS-Gen Issue 3 (December 2010) General Requirements and Information for the Certification of Radiocommunication Equipment [5] ICES-003 Issue 5 (February 2012) Spectrum Management and Telecommunication Policy Interference Causing Equipment Standard – Digital Apparatus TEST RESULT The requirements of the tests performed as shown in the overview (chapter 4 of this test report) were fulfilled by the equipment under test. The complete test results are presented in the following. RESERVATION This test report is only valid in its original form. Any reproduction of its contents in extracts without written permission of the accredited test laboratory PHOENIX TESTLAB GmbH is prohibited. The test results herein refer only to the tested sample. PHOENIX TESTLAB GmbH is not responsible for any generalisations or conclusions drawn from these test results concerning further samples. Any modification of the tested samples is prohibited and leads to the invalidity of this test report. Each page necessarily contains the PHOENIX TESTLAB Logo and the TEST REPORT NUMBER. Test engineer: Michael DINTER 2 November 2012 Name Signature Date Authorized reviewer: Raimund BLASK 6 November 2012 Name Signature Date Testengineer: Michael DINTER Report Number: F123762E3 Date of issue: 30 October 2012 Order Number: 12-113762 page 3 of 26 Contents: Page 1 IDENTIFICATION ............................................................................................................................... 4 1.1 APPLICANT ............................................................................................................................... 4 1.2 MANUFACTURER ..................................................................................................................... 4 1.3 TEST LABORATORY ................................................................................................................ 4 1.4 EUT (EQUIPMENT UNDER TEST) ............................................................................................ 5 1.5 TECHNICAL DATA OF EQUIPMENT ........................................................................................ 5 1.6 DATES ...................................................................................................................................... 5 2 OPERATIONAL STATES AND PHYSICAL BOUNDARIES ................................................................. 6 3 ADDITIONAL INFORMATION ............................................................................................................ 7 4 OVERVIEW ........................................................................................................................................ 7 5 TEST RESULTS ................................................................................................................................. 8 5.1 CONDUCTED EMISSION MEASUREMENT ON AC MAINS (150 kHz to 30 MHz) .................... 8 5.1.1 METHOD OF MEASUREMENT (CONDUCTED EMISSION MEASUREMENT ON AC MAINS (150 kHz to 30 MHz)) ......................................................................................... 8 5.1.2 TEST RESTULTS (CONDUCTED EMISSION MEASUREMENT ON AC MAINS) .......... 9 5.2 RADIATED EMISSIONS ............................................................................................................ 11 5.2.1 METHOD OF MEASUREMENT (RADIATED EMISSIONS) ............................................ 11 5.2.2 PRELIMINARY RADIATED EMISSION TEST (9 kHz to 1 GHz) ..................................... 18 5.2.3 FINAL RADIATED EMISSION TEST (9 kHz to 30 MHz) ................................................ 22 5.2.4 FINAL RADIATED EMISSION TEST (30 MHz to 1 GHz) ............................................... 23 6 REPORT HISTORY ............................................................................................................................ 25 7 TEST EQUIPMENT AND ANCILLARIES USED FOR TESTS ............................................................. 25 8 LIST OF ANNEXES ............................................................................................................................ 26 Testengineer: Michael DINTER Report Number: F123762E3 Date of issue: 30 October 2012 Order Number: 12-113762 page 4 of 26 1 IDENTIFICATION 1.1 APPLICANT Name: NTware Systemprogrammierung GmbH Address: Niedersachenstraße 6 49186 Bad Iburg Country: Germany Name for contact purposes: Mr H. Bauszus Tel: +49-(0)-5403-7243-220 Fax: +49-(0)-5403-780103 e-mail address: [email protected] 1.2 MANUFACTURER Name: NTware Systemprogrammierung GmbH Address: Niedersachenstraße 6 49186 Bad Iburg Country: Germany Name for contact purposes: Mr H. Bauszus Tel: +49-(0)-5403-7243-220 Fax: +49-(0)-5403-780103 e-mail address: [email protected] 1.3 TEST LABORATORY The tests were carried out at: PHOENIX TESTLAB GmbH Königswinkel 10 32825 Blomberg Germany accredited by DGA Deutsche Gesellschaft für Akkreditierung mbH in compliance with DIN EN ISO/IEC 17025 under Reg. No. DGA-PL-105/99-22 Industry Canada Test site registration 3469A-1 recognized by Bundesnetzagent…
Text truncated - open the document above for the full version.
ANNEX A:PHOTOGRAPHS OF TH TEST SET-UPS Examiner: Michael DINTER Test Report No.: F123762E3 Date of issue: 30 October 2012 Order No.: 12-113762 page 1 of 5 123762fcc1 ANNEX A:PHOTOGRAPHS OF TH TEST SET-UPS Examiner: Michael DINTER Test Report No.: F123762E3 Date of issue: 30 October 2012 Order No.: 12-113762 page 2 of 5 123762fcc2 ANNEX A:PHOTOGRAPHS OF TH TEST SET-UPS Examiner: Michael DINTER Test Report No.: F123762E3 Date of issue: 30 October 2012 Order No.: 12-113762 page 3 of 5 123762fcc3 ANNEX A:PHOTOGRAPHS OF TH TEST SET-UPS Examiner: Michael DINTER Test Report No.: F123762E3 Date of issue: 30 October 2012 Order No.: 12-113762 page 4 of 5 123762fcc4 ANNEX A:PHOTOGRAPHS OF TH TEST SET-UPS Examiner: Michael DINTER Test Report No.: F123762E3 Date of issue: 30 October 2012 Order No.: 12-113762 page 5 of 5 123762fcc5
| # | Rule Parts | Frequency Range | Power Output | Tolerance |
|---|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - | 0.0100000000 % |

uniFLOW Release Station Hitag
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
uniFLOW Release Station
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
uniFLOW Release Station Plus
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
uniFLOW Release Station HID
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
USB to Ethernet Bridge
Equipment Class
JBC - Part 15 Class B Computing Device/Personal Computer