Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Oct 13, 2014
Application Purpose
Original Equipment
Date of Application
Oct 13, 2014
Equipment Note
uniFLOW Release Station HID
Frequency Range
0.12500000 - 0.12500000
Company
NT-ware Systemprogrammierung GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

uniFLOW Release Station Installation & Configuration Versioning Versioning Version Date Author(s) Reviewer(s) 1.0 03-Sep-2014 Sebastian Husnik Oliver Shikaloski, Holger Bauszus, Thomas Lemmer 1.1 05-Sep-2014 Sebastian Husnik Thomas Lemmer 1.2 08-Sep-2014 Sebastian Husnik Thomas Lemmer 1.3 17-Sep-2014 Sebastian Husnik Thomas Lemmer 1.4 06-Oct-2014 Sebastian Husnik Thomas Lemmer 1.5 08-Oct-2014 Sebastian Husnik Thomas Lemmer WP Name uniFLOW Release Station - Installation & Configuration Knowledgebase MOMKB-770 https://web.nt-ware.net/its/browse/MOMKB-770 File Name uniFLOW Release Station - Installation & Configuration.pdf Technologies concerned uniFLOW Release Station, uniFLOW Short Summary This document describes the installation and configuration of the uniFLOW Release Station. Document changes Version Topic(s) Changes 1.1 Configuration (on page 12), Network Configuration (on page 21), Firmware Update (on page 23), Factory Reset (on page 22), Job Release via uniFLOW Release Station (on page 24)  Added note that IPv6 is not supported  Added note about USB drive file system (FAT, FAT32)  Updated cost center search description 1.2 Card Reader (on page 18)  Added PLUS card reader configuration instructions 1.3 Mounting Options (on page 10)  Corrected a link 1.4 Card Reader (on page 18)  Added MiCard PLUS config tool download instructions. 1.5 FCC and IC Compliance Notes (on page 4)  Updated IC Notes Disclaimer All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems - without the prior written permission of NT-ware Systemprogrammierung GmbH. Company and product names mentioned herein are registered or unregistered trademarks of their respective companies. Mention of third-party products is for information purposes only and constitutes neither an endorsement nor a recommendation. NT-ware assumes no responsibility with regard to the performance or use of these products. Also, NT-ware makes no claim to these trademarks. Any use of trademarks, logo, service marks, trade names, and product names is prohibited without the written permission of the respective owners. Adlib, Express and Express Server are either registered trademarks or trademarks of Adlib Publishing Systems Inc.; Adobe®, Adobe® Reader, Acrobat®, Distiller®, PostScript® and products of the CREATIVE SUITE(S) are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States and/or other countries; Apple®, the Apple® logo, Mac®, Mac OS®, Macintosh®, iPhone®, iPad® and AirPrint® are trademarks of Apple Inc. registered in the U.S. and other countries; Box of Box Inc.; Blackboard Transact™ of Blackboard Inc.; CANON, imageRUNNER, imageRUNNER ADVANCE, MEAP, CPCA, AMS, iW AMS, iW Desktop, iSend, iW SAM are trademarks or registered trademarks of Canon Inc.; CBORD CS Gold® of the CBORD Group Inc.; Crystal Reports and other Business Objects products and services mentioned herein as well as their respective logos are trademarks or registered trademarks of Business Objects Software Ltd. Business Objects is an SAP company; Dropbox of Dropbox Inc.; eCopy™, eCopy® ShareScan®, and eCopy® ScanStation® are marks or trademarks of Nuance Communications, Inc.; Evernote® of Evernote Corporation; FileNet® of IBM Corporation; Foxit®SDK and Foxit® Reader of Foxit Corporation; Google Docs of Google Inc.; Google Cloud Print™ web printing service is a trademark of Google Inc.; Helix™ Production Workflow is a trademark of NT-ware Systemprogrammierung GmbH; HP, HEWLETT-PACKARD, PCL and LASERJET are registered trademarks that belong to Hewlett-Packard Development Company, L.P.; iOS® of Cisco Technology Inc.; iDRS™ SDK and IRISConnect™ are unregistered trademarks of I.R.I.S. Group S.A.; JAWS pdf courier™ are trademarks of Global Graphics SA.; Microsoft®, Windows®, Windows Vista®, Windows 7®, Internet Explorer®, Internet Information Services, Microsoft® Word, Microsoft® Excel, OneDrive, SQL Server® are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries of Microsoft Corporation; Neevia Document Converter Pro™ of Neevia Technology; Novell®is a registered trademark of Novell Inc. in the United States and other countries; OpenOffice.org™ of Oracle Corporation; PAS™ NetWare Print Server is a trademark of Equitrac Corp.; PosterJet is copyrighted and an internationally registered trademark of Eisfeld Datentechnik GmbH & Co. KG; Red Titan EscapeE of Red Titan Limited; NETAPHOR®, SiteAudit™ are trademarks of NETAPHOR SOFTWARE Inc.; Therefore™ of Therefore; UNIX® is a registered trademark of The Open Group; uniFLOW®, uniFLOW Serverless Secure Printing®, Helix Production Workflow®, MIND®, microMIND®, and MiCard® are registered trademarks of NT-ware Systemprogrammierung GmbH; pcProx®, AIR ID® are registered trademarks of RFIdeas Inc.Readers; CASI-RUSCO® is a registered trademark of ID Card Group; Radio Key® is a registered trademark of Secura Key; GProx™ II is an unregistered trademark of Guardall; HID® ProxHID is a registered trademark of HID Global Corporation; Indala® is a registered trademark of Motorola; ioProx™ is an unregistered trademark of Kantech. All other trademarks, trade names, product names, service marks are property of their respective owners and are hereby acknowledged. While every precaution has been taken in the preparation of this document, NT-ware assumes no responsibility for errors or omissions, or for damages resulting from the use of information contained in this document or from the use of programs and source code that may accompany it. NT-ware does not assume any responsibility or liability for any malfunctions or loss of data caused by the combination of at least one NT-ware product and the used operation system and/or third-party products. In no event shall NT-ware be liable for any loss of profi…

Text truncated - open the document above for the full version.

Cover Letter(s)

N.ware NT-ware GmbH NiedersachsenstraĂźe 6 0-49186 Bad Iburg Request for Confidentiality PHOENIX TESTLAB GmbH Product Certification Königswinkel 10 Date: 10.09.2014 o 32825 Blomberg RE: FCC ID: Certification Application WG7URSHID01 Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission's Rule, the applicant hereby requests confidential treatment of information accompanying this application as outlined below: • Schematics • Part List • Block Diagram • Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457, disclosure of this application and all accompanying documentation will not be made before the date of the GRANT for this application .. Thank you for your attention in this matter. Applicant's Company address :NT-ware Systemprogrammierung GmbH Niedersachsenstrasse 6 49186 Bad Iburg ; () .1-' ~ ~JT lII.re Systemprogrammierungs GmbH NiedersachsenstraĂźe 6 49186 Bad Iburg Germany Fon +49 5403 7243-0 Fax +495403780103 Signature Job Title and Dept. : HW Developer HW Dept. NT-WARE Systemprogrammierungs-GmbH NiedersachsenstraĂźe 6 49186 Bad Iburg Germany Telefon: +495403 7243-0 Telefax: +49 5403 780103 www.nt-ware.com [email protected] GeschäftsfĂĽhrer: Karsten Huster AG OsnabrĂĽck; HRB 110944 Sitz: Bad Iburg USt-ld-Nr. DE 230932 141 WEEE-Reg.-Nr. DE 49358956

External Photos

Annex B External photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 1 of 1 144372_EUT1 Annex B External photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 2 of 2 144372_EUT2 Annex B External photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 3 of 3 144372_EUT3 Annex B External photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 4 of 4 144372_EUT4 Annex B External photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 5 of 5 144372_EUT15 Annex B External photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 6 of 6 144372_EUT16

ID Label/Location Info

Lable Location Info

Internal Photos

Annex C Internal photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 1 of 17 144372_EUT5 Annex C Internal photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 2 of 17 144372_EUT6 Annex C Internal photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 3 of 17 144372_EUT7 Annex C Internal photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 4 of 17 144372_EUT8 Annex C Internal photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 5 of 17 144371_EUT8a Annex C Internal photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 6 of 17 144372_EUT9 Annex C Internal photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 7 of 17 144372_EUT10 Annex C Internal photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 8 of 17 144372_EUT11 Annex C Internal photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 9 of 17 144372_EUT12 Annex C Internal photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 10 of 17 144372_EUT13 Annex C Internal photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 11 of 17 144372_HID1 Annex C Internal photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 12 of 17 144372_HID2 Annex C Internal photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 13 of 17 144372_HID3 Annex C Internal photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 14 of 17 144372_HID4 Annex C Internal photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 15 of 17 144372_HID5 Annex C Internal photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 16 of 17 144372_HID6 Annex C Internal photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 17 of 17 144372_HID7

Test Report

Königswinkel 10 32825 Blomberg Germany Phone +49 5235 9500-0 Fax +49 5235 9500-10 Test Report Report Number: F144372E1 Applicant: NT-ware Systemprogrammierung GmbH Manufacturer: NT-ware Systemprogrammierung GmbH Equipment under Test (EUT): Printer terminal interface uniFLOW Release Station HID Laboratory (CAB) accredited by Deutsche Akkreditierungsstelle GmbH (DAkkS) in compliance with DIN EN ISO/IEC 17025 under the Reg. No. D-PL-17186-01-02, FCC Test site registration number 90877 and Industry Canada Test site registration IC3469A-1 Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 2 of 30 REFERENCES [1] ANSI C63.4:2009 American National Standard for Methods of Measuring of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. [2] FCC 47 CFR Part 15 Radio Frequency Devices [3] ICES-003 Issue 5 (August 2012) Information Technology Equipment (ITE) – Limits and methods of measurement [4] RSS-Gen Issue 3 (December 2010) General Requirements and Information for the Certification of Radiocommunication Equipment TEST RESULT The requirements of the tests performed as shown in the overview (chapter 4 of this test report) were fulfilled by the equipment under test. The complete test results are presented in the following. RESERVATION This test report is only valid in its original form. Any reproduction of its contents in extracts without written permission of the accredited test laboratory PHOENIX TESTLAB GmbH is prohibited. The test results herein refer only to the tested sample. PHOENIX TESTLAB GmbH is not responsible for any generalisations or conclusions drawn from these test results concerning further samples. Any modification of the tested samples is prohibited and leads to the invalidity of this test report. Each page necessarily contains the PHOENIX TESTLAB Logo and the TEST REPORT NUMBER. Test engineer: Michael DINTER 16 September 2014 Name Signature Date Authorized reviewer: Bernd STEINER 16 September 2014 Name Signature Date Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 3 of 30 Contents: Page 1 Identification ..................................................................................................................................... 4 1.1 Applicant .................................................................................................................................. 4 1.2 Manufacturer............................................................................................................................ 4 1.3 Test laboratory ......................................................................................................................... 4 1.4 EUT (equipment Under Test) ................................................................................................... 5 1.5 Technical data of equipment .................................................................................................... 5 1.6 Dates ....................................................................................................................................... 7 2 Operational states and physical boundaries ...................................................................................... 8 3 Additional information ....................................................................................................................... 9 4 Overview .......................................................................................................................................... 9 5 Test results ..................................................................................................................................... 10 5.1 Conducted emission measurement on AC mains (150 kHz to 30 MHz) .................................. 10 5.1.1 Method of measurement conducted emission ............................................................. 10 5.1.2 Test result (conducted emission measurement on AC mains) ..................................... 11 5.2 Radiated emissions ................................................................................................................ 13 5.2.1 Method of measurement (radiated emissions) ............................................................ 13 5.2.2 Preliminary radiated emission tests (9 kHz to 30 MHz) ............................................... 20 5.2.3 Preliminary radiated emission tests (30 MHz to 1 GHz) .............................................. 22 5.2.4 Preliminary radiated emission tests (1 GHz to 6 GHz) ................................................ 23 5.2.5 Final radiated emission test (9 kHz to 30 MHz) ........................................................... 24 5.2.6 Final radiated emission test (30 MHz to 1 GHz) .......................................................... 25 5.3 Test results (20 dB bandwidth) ............................................................................................... 28 6 Report history ................................................................................................................................. 29 7 Test equipment and ancillaries used for tests .................................................................................. 29 8 List of annexes ............................................................................................................................... 30 Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 4 of 30 1 Identification 1.1 Applicant Name: NTware Systemprogrammierung GmbH Address: NiedersachenstraĂźe 6 49186 Bad Iburg Country: Germany Name for contact purposes: Mr H. Bauszus Tel: +49-(0)-5403-7243-220 Fax: +49-(0)-5403-780103 e-mail address: [email protected] 1.2 Manufacturer Name: NTware Systemprogrammierung GmbH Address: NiedersachenstraĂźe 6 49186 Bad Iburg …

Text truncated - open the document above for the full version.

Test Setup Photos

Annex A Test setup photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 1 of 1 144372_emi1 Annex A Test setup photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 2 of 2 144372_emi2 Annex A Test setup photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 3 of 3 144372_emi3 Annex A Test setup photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 4 of 4 144372_emi4 Annex A Test setup photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 5 of 5 144372_emi5 Annex A Test setup photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 6 of 6 144372_emi6 Annex A Test setup photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 7 of 7 144372_emi7 Annex A Test setup photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 8 of 8 144372_emi8 Annex A Test setup photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 9 of 9 144372_emic1 Annex A Test setup photos Testengineer: Michael DINTER Report Number: F144372E1 Date of issue: 16 September 2014 Order Number: 14-114372 page 10 of 10 144372_emic2

Contact Information

Applicant

Holger Bauszus(Hardware Developer)
[email protected]+49-5403-7243220Fax: +49-5403-780103

Test Firm

Phoenix TestLab GmbHH. Altmaier
[email protected]49-5235-9500-0Fax: 49-5235-9500-10

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.125 MHz - 0.125 MHz-
Confidentiality
Long Term
Grant Notes
Snap ferrite Wuerth No 742 718 33.

Other Applications from NT-ware Systemprogrammierung GmbH

uniFLOW Release Station Hitag - FCC ID WG7URSHITAG01 - NT-ware Systemprogrammierung GmbH
WG7URSHITAG01

uniFLOW Release Station Hitag

Oct 13, 2014

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
uniFLOW Release Station - FCC ID WG7URSMULTI01 - NT-ware Systemprogrammierung GmbH
WG7URSMULTI01

uniFLOW Release Station

Oct 13, 2014

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
uniFLOW Release Station Plus - FCC ID WG7URSPLUS01 - NT-ware Systemprogrammierung GmbH
WG7URSPLUS01

uniFLOW Release Station Plus

Oct 13, 2014

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
USB RF-Cardreader MiCard V3 - FCC ID WG7MICARDLM03 - NT-ware Systemprogrammierung GmbH
WG7MICARDLM03

USB RF-Cardreader MiCard V3

Feb 07, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
USB to Ethernet Bridge - FCC ID WG7-MICROMIND1 - NT-ware Systemprogrammierung GmbH
WG7-MICROMIND1

USB to Ethernet Bridge

Sep 12, 2010

Equipment Class

JBC - Part 15 Class B Computing Device/Personal Computer