Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Manual Requirement of FCC Our product (FCC ID: WJ6ICM0M0-1X90) will be sold and installed into certain end products. Therefore, we will not supply the user’s manual. However, we will ask the end-product manufacturer to include following statements in the end-product user manual in accordance with FCC requirements. Also, Installation manual is included in Theory of Operation as it contains technical confidential information. Requirement for User Manual This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Properly shielded and grounded cables and connectors must be used for connection to host computers and / or peripherals in order to meet FCC emission limits. NOTICE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures : -- Reorient or relocate the receiving antenna -- Increase the separation between the equipment and receiver -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. Requirement for Product Label we will ask the end-product manufacturer to affix the following on the end-product. - Contains FCC ID : WJ6ICM0M0-1X90
RF Module Name : ICM0M0-1x90 RF Module Name : ICM0M0-1x90RF Module Name : ICM0M0-1x90 RF Module Name : ICM0M0-1x90Photograph 1 Photograph 1Photograph 1 Photograph 1 Surface SurfaceSurface SurfaceReverse ReverseReverse Reverse Circuit of wireless with shield Circuit of wireless with shield Circuit of wireless with shield Circuit of wireless with shield Circuit of wireless without shield Circuit of wireless without shield Circuit of wireless without shield Circuit of wireless without shield
F C C I D : W J 6 I C M 0 M 0 - 1 X 9 0 F C C I D : W J 6 I C M 0 M 0 - 1 X 9 0
RF Module Name : ICM0M0-1x90 RF Module Name : ICM0M0-1x90RF Module Name : ICM0M0-1x90 RF Module Name : ICM0M0-1x90Photograph 1 Photograph 1Photograph 1 Photograph 1 Surface SurfaceSurface SurfaceReverse ReverseReverse Reverse Circuit of wireless with shield Circuit of wireless with shield Circuit of wireless with shield Circuit of wireless with shield Circuit of wireless without shield Circuit of wireless without shield Circuit of wireless without shield Circuit of wireless without shield
Test report No. : 10004105S Page : 2 of 25 Issued date : February 21, 2013 Revised date : March 14, 2013 FCC ID : WJ6ICM0M0-1X90 UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 REVISION HISTORY Original Test Report No.: 10004105S Revision Test report No. Date Page revised Contents - (Original) 10004105S February 21, 2013 - - 1 10004105S March 14, 2013 1-12 P1-12: Change of FCC ID P10: Addition of description about ID tag Test report No. : 10004105S Page : 3 of 25 Issued date : February 21, 2013 Revised date : March 14, 2013 FCC ID : WJ6ICM0M0-1X90 UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 Contents Page SECTION 1: Customer information ........................................................................................ 4 SECTION 2: Equipment under test (E.U.T.) .......................................................................... 4 SECTION 3: Test specification, procedures & results ............................................................ 5 SECTION 4: Operation of E.U.T. during testing .................................................................... 8 SECTION 5: Conducted emission ........................................................................................... 9 SECTION 6: Radiated emission (Fundamental and Spurious emission) ............................. 10 SECTION 7: 20dB bandwidth & Occupied bandwidth (99%) ............................................ 11 SECTION 8: Frequency tolerances ........................................................................................ 11 Contents of APPENDIXES ...................................................................................................... 12 APPENDIX 1: Data of radio tests .......................................................................................... 13 APPENDIX 2: Test instruments ............................................................................................ 22 APPENDIX 3: Photographs of test setup .............................................................................. 23 Test report No. : 10004105S Page : 4 of 25 Issued date : February 21, 2013 Revised date : March 14, 2013 FCC ID : WJ6ICM0M0-1X90 UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 SECTION 1: Customer information Company Name : NIDEC SANKYO CORPORATION Address : 5329, Shimosuwa-machi, Suwa-gun, Nagano, 393-8511 Japan Telephone Number : +81-266-27-4774 Facsimile Number : +81-266-27-4620 Contact Person : Junro Takeuchi SECTION 2: Equipment under test (E.U.T.) 2.1 Identification of E.U.T. Type of Equipment : Contactless IC card reader Model No. : ICM0M0-1x90 Serial No. : Refer to Section 4, Clause 4.2 Rating : DC 12V Receipt Date of Sample : January 30 and February 5, 2013 Country of Mass-production : Japan Condition of EUT : Production model Modification of EUT : No Modification by the test lab 2.2 Product description Model: ICM0M0-1x90 (referred to as the EUT in this report), is a Contactless IC card reader. Clock Frequency: 27.12MHz (RFID part) Radio specification: Equipment type : Transceiver Frequency of operation : 13.56MHz Type of modulation : ASK Antenna type : Integrated Antenna connector type : None FCC 15.31 (e) The equipment provides the wireless transmitter with stable power supply (DC3.3V). Therefore, the equipment complies with the requirement. FCC 15.203 It is impossible for end users to replace the antenna, because the antenna is mounted on the board integrally. Therefore, the equipment complies with the requirement. Test report No. : 10004105S Page : 5 of 25 Issued date : February 21, 2013 Revised date : March 14, 2013 FCC ID : WJ6ICM0M0-1X90 UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 SECTION 3: Test specification, procedures & results 3.1 Test specification Test specification : Test specification: FCC Part 15 Subpart C: 2012, final revised on December 27, 2012 and effective January 28, 2013 Title : FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators Section 15.207 Conducted limits Section 15.209 Radiated emission limits, general requirements Section 15.215 Additional provisions to the general radiated emission limitations Section 15.225 Operation within the band 13.110-14.010MHz 3.2 Procedures & Results Item Test Procedure SpecificationRemarksDeviation Worst Margin Results Conducted emission ANSI C63.4:2009 7. AC power line conducted emission measurements FCC 15.207 - N/A 2.6dB 14.0100MHz, Average, Phase: N Complied Electric field strength of Fundamental emission ANSI C63.4:2009 13. Measurement of intentional radiators FCC 15.225(a) - N/A 44.2dB 13.56MHz, Quasi-Peak, Vertical Complied Electric field strength of Spurious emission (within the 13.110-14.010MHz band) ANSI C63.4:2009 13. Measurement of intentional radiators FCC 15.225(b)(c) - N/A 24.6dB 13.553MHz, Quasi-Peak, Vertical Complied Electric field strength of Spurious emission (outside of the 13.110-14.010MHz band) ANSI C63.4:2009 13. Measurement of intentional radiators FCC 15.209, FCC 15.225 (d) - N/A 8.5dB 40.69MHz, Quasi-Peak, Vertical Complied 20dB bandwidth ANSI C63.4:2009 13. Measurement of intentional radiators FCC 15.215(c) - N/A - - Frequency tolerance ANSI C63.4:2009 13. Measurement of intentional radiators FCC 15.225 (e) RadiatedN/A - Complied Note: UL Japan’s Work Procedures No. 13-EM-W0420 and 13-EM-W0422 Test report No. : 10004105S Page : 6 of 25 Issued date : February 21, 2013 Revised date : March 14, 2013 FCC ID : WJ6ICM0M0-1X90 UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 3…
Text truncated - open the document above for the full version.
Test report No. : 10004105S Page : 23 of 25 UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka Hiratsuka-shi Kanagawa-ken 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 APPENDIX 3: Photographs of test setup Conducted emission Front Side Test report No. : 10004105S Page : 24 of 25 UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka Hiratsuka-shi Kanagawa-ken 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 Radiated emission Front Rear (below 30MHz) Horizontal Rear (below 30MHz) Vertical Rear (above 30MHz) Test report No. : 10004105S Page : 25 of 25 UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka Hiratsuka-shi Kanagawa-ken 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 Pre-check of worst position X-axis Y-axis Z-axis END OF REPORT
1-22-3 Megumigaoka,Hiratsuka-shi · Kanagawa-ken · Japan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |
RFID Module
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
ID Card Reader
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Contactless IC card reader module
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterContactless IC Card Dispenser
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter