WJHWD11Alertme Wireless Contact Sensor : Window/Door 1-1

Centrica Hive Limited
Alertme Wireless Contact Sensor : Window/Door 1-1 - FCC ID WJHWD11 - Centrica Hive Limited
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 10, 2008
Application Purpose
Original Equipment
Date of Application
Nov 10, 2008
Equipment Note
Alertme Wireless Contact Sensor : Window/Door 1-1
Frequency Range
2405.00000000 - 2475.00000000
Company
Centrica Hive Limited
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

09-Sept-2008 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046-1609 TRL, Nipe Lane Up Holland, Lancashire, WN8 9PY, UK Re: Confidentiality Request Gentlemen: This letter is to comply with 47 CFR 0.457(d)(2) pertaining to confidential material. AlertMe.com requests that the following documents regarding this submission for FCC IDs WJH-W11, WJH- B11, WJH-L21, WJH-KF11, WJH-MD11, WJH-AD11, WJH-DH12 and WJH-H12 be kept confidential: 1. Schematics 2. Block Diagram 3. Circuit/Technical Description 4. Bill of Materials 5. PCB Layouts The material above contains technical data, which would customarily be guarded from competitors. Sincerely, Amyas Phillips Product Manager AlertMe.com

External Photos

KTL EMC Test Report: 7F1040WUS1 Photograph 4 59

ID Label/Location Info

14.0 5.0 R0.5 AM_WD_101 ASSY MEC0070 LOCATION ISOMETRIC VIEW SCALE 1:1 XXXX 20/10/08R FARN XXXX NOTES: SELF ADHESIVE LABEL TO BE PLACED IN POSITION SHOWN1. lABEL TO BE WHITE WITH BLACK TEXT2. REVISIONS REV.DESCRIPTIONDATE DRAWN APPROVED AFirst Issue20/10/08RGFXXX BChange in label location29/10/08RGF DO NOT SCALE DRAWING DIMENSIONS ARE IN MM TOLERANCES: ANGULAR: 0.5 0 DECIMAL PLACES 0.5mm 1 DECIMAL PLACES 0.2mm 2 DECIMAL PLACES 0.1mm THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EG TECHNOLOGY LTD. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF EG TECHNOLOGY LTD IS PROHIBITED. PROPRIETARY AND CONFIDENTIAL 1234 A B C D E F MATERIAL FINISH DATE EG TECHNOLOGY LTD BURLEIGH HOUSE 13-15 NEWMARKET ROAD CAMBRIDGE +44 (0)1223 710799 MEC0070-B DRAWN BY ANY QUESTIONS? PLEASE ASK! Sheet 1 of 1 SCALE 4:1

Internal Photos

KTL EMC Test Report: 7F1040WUS1 Photograph 5 60 KTL EMC Test Report: 7F1040WUS1 Photograph 6 61

RF Exposure Info

KTL EMC Test Report: 7F1040WUS1 Appendix G:MPE Calculation OET Bulletin No. 65, Supplement C 01-01 47 CFR §§1.1307 and 2.1091 2.1091 Radio frequency radiation exposure evaluation: mobile devices. A mobile device is defined as a transmitting device designed to be used in other than fixed locations and to generally be used in such a way that a separation distance of at least 20 centimetres is normally maintained between the transmitter’s radiating structure(s) and the body of the user or nearby persons. In this context, the term ‘‘fixed location’’ means that the device is physically secured at one location and is not able to be easily moved to another location. Transmitting devices designed to be used by consumers or workers that can be easily re-located, such as wireless devices associated with a personal computer, are considered to be mobile devices if they meet the 20 centimetre separation requirement. Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 where: S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the centre of radiation of the antenna Maximum peak output power at the antenna terminal: 2.52 dBm Maximum peak output power at the antenna terminal: 1.78648757 mW Antenna gain (typical):-1.9dBi Maximum antenna gain:0.645654229numeric Prediction distance: 20 cm Prediction frequency: 2475 MHz Result Prediction Frequency (MHz) Maximum allowable antenna gain: (dBi) Power density (S) at prediction frequency: (mW/cm 2 ) MPE limit for uncontrolled exposure at prediction frequency: (mW/cm 2 ) Result 247534.492698550.0002291Pass 2 4R PG S Ä Ä

Test Report

Total number of pages : 63 grepbl.doc Ver: g01/10 "7F1040WUS1" KTL EMC Test Report : 7F1040WUS1 Applicant : AlertMe.com Ltd Apparatus : Wireless Contact Sensor: Window/Door 1-1 Authorised by : : K J Anderson, Senior EMC and Radio Engineer Issue Date : 9 th September 2008 Authorised Copy Number : PDF KTL EMC Test Report: 7F1040WUS1 2 Contents Section 1: Introduction 3 1.1 General 3 1.2 Tests Requested By 4 1.3 Manufacturer 4 1.4 Apparatus Assessed 4 1.5 Test Result Summary 5 1.6 Notes Relating To The Assessment 6 1.7 Deviations from Test Standards 6 Section 2: Measurement Uncertainty 7 2.1 Application of Measurement Uncertainty 7 2.2 KTL Measurement Uncertainty Values 8 Section 3: Modifications 9 3.1 Modifications Performed During Assessment 9 Appendix A: Formal Emission Test Results 10 A1 Conducted Fundamental Carrier Power 11 A2 RF Antenna Conducted Spurious Emissions 12 A3 Radiated Electric Field Emissions Within The Restricted Band 15.205 17 A4 6 dB Bandwidth 22 A5 Antenna Gain 23 A6 Power Spectral Density 24 Appendix B: Supporting Graphical Data 25 Appendix C: Additional Test and Sample Details 44 Appendix D: Additional Information 51 Appendix E: Calculation of the duty cycle correction factor 54 .Appendix F: Photographs and Figures 54 Appendix F: Photographs and Figures 55 Appendix G: MPE Calculation 62 KTL EMC Test Report: 7F1040WUS1 Section 1: Introduction 1.1 General This report contains an assessment of an apparatus against Electromagnetic Compatibility Standards based upon tests carried out on samples submitted to the Laboratory. Test performed by: KTL Unit E South Orbital Trading Park Hedon Road Hull, HU9 1NJ. United Kingdom. Telephone: +44 (0) 1482 801801 Fax: +44 (0) 1482 801806 Email: [email protected] Web site: www.ktl.com Tests performed by: , Senior EMC and Radio Group Engineer Report author:. As Above This report must not be reproduced except in full without prior written permission from KTL. 3 KTL EMC Test Report: 7F1040WUS1 1.2 Tests Requested By This testing in this report was requested by : AlertMe.com Ltd 27-28 Bridge Street Cambridge CB21UJ United Kingdom 1.3 Manufacturer In-Tech Electronics Ltd N2 Qihang Industrial Park Haoxiang Road Sha Jing Town Bao An Shenzhen PRC 1.4 Apparatus Assessed The following apparatus was assessed between 03/06/0/8 and 24/06/08: Alertme Wireless Contact Sensor: Window/Door 1-1 The above equipment was a wireless Alertme Window/door contact sensor as part of an intelligent home security and monitoring service operating in the 2.4GHz band. 4 KTL EMC Test Report: 7F1040WUS1 1.5 Test Result Summary Full details of test results are contained within Appendix A. The following table summarises the results of the assessment. The statements relating to compliance with the standards below apply ONLY as qualified in the notes and deviations stated in sections 1.6 to 1.7 of this test report. Full details of test results are contained within Appendix A. The following table summarises the results of the assessment. Test Type Regulation Measurement standard Result CFCP Title 47 of the CFR :2008, Part 15 Subpart (c) 15.247(b)(3) ANSI C63.4: 2003 Pass RF Antenna Port Conducted Spurious Emissions Title 47 of the CFR: 2008, Part 15 Subpart (c) 15.247(d) ANSI C63.4: 2003 Pass REFE (Within the restricted band) Title 47 of the CFR: 2008, Part 15 Subpart (c) 15.247(d) and 15.205 ANSI C63.4: 2003 Pass PLCE Title 47 of the CFR: 2008, Part 15 Subpart (c) 15.207 ANSI C63.4: 2003 N/A 6dB Bandwidth Title 47 of the CFR :2008, Part 15 Subpart (c) 15.247(a)(2) ANSI C63.4: 2003 Pass Antenna Gain Title 47 of the CFR :2008, Part 15 Subpart (c) 15.247(b)(4) ANSI C63.4: 2003 Pass Power Spectral Density Title 47 of the CFR :2008, Part 15 Subpart (c) 15.247(e) ANSI C63.4: 2003 Pass Abbreviations used in the above table: Mod : Modification CFR : Code of Federal Regulations ANSI : American National Standards Institution REFE : Radiated Electric Field Emissions PLCE : Power Line Conducted Emissions CFCP : Conducted Fundamental Carrier Power 5 KTL EMC Test Report: 7F1040WUS1 1.6 Notes Relating To The Assessment With regard to this assessment, the following points should be noted: The results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples and the date of issue of the report. The apparatus was set up and exercised using the configurations, modes of operation and arrangements defined in this report only. Particular operating modes, apparatus monitoring methods and performance criteria required by the standards tested to have been performed except where identified in Section 1.7 of this test report (Deviations from Test Standards). For emissions testing, throughout this test report, “Pass” indicates that the results for the sample as tested were below the specified limit (refer also to Section 2, Measurement Uncertainty). Where relevant, the apparatus was only assessed using the monitoring methods and susceptibility criteria defined in this report. All testing with the exception of testing at the Open Area Test Site was performed under the following environmental conditions: Temperature : 17 to 23 °C Humidity : 45 to 75 % Barometric Pressure : 86 to 106 kPa All dates used in this report are in the format dd/mm/yy. This assessment has been performed in accordance with the requirements of ISO/IEC 17025. KTL Hull is a listed electromagnetic compatibility Conformance Assessment Body (CAB) for EC access to the US market. (Decision No 3/2000 of the Joint Committee established under the Agreement on Mutual Recognition between the European Community and the United States of America. This decision was effective from 16 th January 2001). FCC Facility Registration number (3m semi anechoic chamber) : 90743 1.7 Deviations from Test Standards There were no deviations from the standards tested to. 6 KTL EMC Test Report: 7F1040WUS1 Section 2: Measurement Uncertainty 2.1 Application of Measurement Uncertainty The foll…

Text truncated - open the document above for the full version.

Test Setup Photos

KTL EMC Test Report: 7F1040WUS1 Photograph 2 57

Contact Information

Applicant

Darrell Harris(Mr)
[email protected]00447867395548Fax: +44(0)1223 361557

Test Firm

Element Materials Technology Warwick LtdMax Leach
[email protected]4401482801801Fax: 44 (0) 1482 801 806

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.80 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted

Other Applications from Centrica Hive Limited

Wireless Smartplug - FCC ID WJHSP11 - Centrica Hive Limited
WJHSP11

Wireless Smartplug

Jun 06, 2012

Equipment Class

DTS - Digital Transmission System
Mini Hub V2 - FCC ID WJHMH11 - Centrica Hive Limited
WJHMH11

Mini Hub V2

Jun 03, 2012

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified
Wireless Repeater - FCC ID WJHRP11 - Centrica Hive Limited
WJHRP11

Wireless Repeater

Jun 03, 2012

Equipment Class

DTS - Digital Transmission System
Wireless Motion Detector - FCC ID WJHMD12 - Centrica Hive Limited
WJHMD12

Wireless Motion Detector

May 30, 2012

Equipment Class

DTS - Digital Transmission System
Wireless Button - FCC ID WJHB12 - Centrica Hive Limited
WJHB12

Wireless Button

May 29, 2012

Equipment Class

DTS - Digital Transmission System