WTO-CP1150CP1150 and CP1150S

Cochlear Limited
CP1150 and CP1150S - FCC ID WTO-CP1150 - Cochlear Limited
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Feb 26, 2020
Application Purpose
Original Equipment
Date of Application
Feb 25, 2020
Equipment Note
CP1150 and CP1150S
Frequency Range
2402.00000000 - 2480.00000000
Company
Cochlear Limited
Country
Australia

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Kanso ® 2 Sound Processor User Guide CP1150 D1694826_1-02_EN_CP1150_UG_Radio-Cert_JAPAN.indd 116/12/2019 3:54:00 PM ii KANSO ® 2 SOUND PROCESSOR USER GUiDE About Your Cochlear™ Kanso® 2 Sound Processor (model number: CP1150) works with your Cochlear implant to transfer sound to your ear. You can control your processor by: • using the Nucleus ® Smart App • tapping on the front – see page 6 • using a Cochlear CR310 Remote Control (optional). information on using the app or remote is available in their user guides. D1694826_1-02_EN_CP1150_UG_Radio-Cert_JAPAN.indd 216/12/2019 3:54:00 PM KANSO ® 2 SOUND PROCESSOR USER GUiDE 1 1 Microphone ports 2 indicator light 3 Cochlear logo 4 Cover Kanso ® 2 Sound Processor Back Front 1 Magnet 2 Socket cover 1 2 4 3 1 2 D1694826_1-02_EN_CP1150_UG_Radio-Cert_JAPAN.indd 116/12/2019 3:54:00 PM 2 KANSO ® 2 SOUND PROCESSOR USER GUiDE Charge your processor To recharge your processor you can: • place it in the Home Charger for charging overnight or • attach it to the Portable Charger (optional accessory) for charging while you’re on the go. More information and warnings are available in the Chargers User Guide. Portable Charger Home Charger D1694826_1-02_EN_CP1150_UG_Radio-Cert_JAPAN.indd 216/12/2019 3:54:00 PM KANSO ® 2 SOUND PROCESSOR USER GUiDE 3 Tapping CONTROLNUMBER OF TAPS Turn ONDouble-tap – 2 taps Turn OFFTriple-tap – 3 taps Change program or audio sourceDouble-tap – 2 taps • Tap on the Cochlear logo. • Use quick, firm taps – don’t press. TIP You can tap your processor while it is on or off your implant. D1694826_1-02_EN_CP1150_UG_Radio-Cert_JAPAN.indd 316/12/2019 3:54:00 PM 4 KANSO ® 2 SOUND PROCESSOR USER GUiDE Turn on and off On: Double-tap (2 taps). Light flashes green as the processor turns on. Off: Triple-tap (3 taps). Light changes to steady orange as the processor turns off. NOTE Sound processor automatically turns on when placed on your implant and turns off when removed from your implant for two minutes (if enabled by clinician). D1694826_1-02_EN_CP1150_UG_Radio-Cert_JAPAN.indd 416/12/2019 3:54:00 PM KANSO ® 2 SOUND PROCESSOR USER GUiDE 5 Change program Double-tap (2 taps) to change program. Light flashes green as the program changes. Number of green flashes or beeps indicates the selected program. NOTE if double-tap to control audio sources is enabled you will be unable to double-tap to change progam. The Nucleus Smart App User Guide has information on where to change this setting. D1694826_1-02_EN_CP1150_UG_Radio-Cert_JAPAN.indd 516/12/2019 3:54:00 PM 6 KANSO ® 2 SOUND PROCESSOR USER GUiDE Stream audio Double-tap (2 taps) to switch between audio sources. Light flashes blue as the audio source changes. Number of blue flashes or beeps indicates the selected program. NOTE if double-tap to control programs is enabled you will be unable to double-tap to change audio source. The Nucleus Smart App User Guide has information on where to change this setting. Each time you double-tap the processor, available audio sources are presented in order. DOUBLE-TAP AUDiO SOURCE 1stProcessor microphone audio 2ndWireless accessory 1 3rdWireless accessory 2 4th...Processor microphone audio... D1694826_1-02_EN_CP1150_UG_Radio-Cert_JAPAN.indd 616/12/2019 3:54:00 PM KANSO ® 2 SOUND PROCESSOR USER GUiDE 7 Attach your processor Place the processor on your implant with the: • Cochlear logo, light and microphone ports facing up • straight edge facing down. CAUTIONS • Make sure you position your processor correctly to get the best performance, and so it does not fall off the implant. • if you have two implants, you must use the correct sound processor for each implant. D1694826_1-02_EN_CP1150_UG_Radio-Cert_JAPAN.indd 716/12/2019 3:54:01 PM 8 KANSO ® 2 SOUND PROCESSOR USER GUiDE Attach a SoftWear pad if you experience discomfort, attach an adhesive Cochlear SoftWear ™ pad to back of processor. D1694826_1-02_EN_CP1150_UG_Radio-Cert_JAPAN.indd 816/12/2019 3:54:02 PM KANSO ® 2 SOUND PROCESSOR USER GUiDE 9 Secure your processor You can attach a Kanso 2 Safety Line to reduce the risk of losing your processor. Press the safety line connector into the processor socket. Attach the clip to your clothing (or hairclip to your hair). D1694826_1-02_EN_CP1150_UG_Radio-Cert_JAPAN.indd 916/12/2019 3:54:03 PM 10 KANSO ® 2 SOUND PROCESSOR USER GUiDE Lights Everyday use LiGHTWHAT iT MEANS ... Processor flashes while receiving sound from microphones (Child mode only). Turning on and changing programs. Number of flashes indicates the number of the current program. ... Processor flashes while receiving sound from audio source (Child mode only). Turning off processor. Alerts LiGHTWHAT iT MEANS ... Processor is off your head (or connected to the wrong implant). Processor battery is low. Recharge processor. Fault. Contact your clinician. Stays on until the issue is resolved. D1694826_1-02_EN_CP1150_UG_Radio-Cert_JAPAN.indd 1016/12/2019 3:54:03 PM KANSO ® 2 SOUND PROCESSOR USER GUiDE 11 The Kanso 2 sound processor comprises: • Two omni-directional microphones for receiving sound. • Custom analogue and digital integrated circuits with digital signal processing (DSP) and bi-directional wireless communication capabilities. • Tri-colour visual indication of processor function or problem. • Tap interface allowing user control of key features. The internal battery provides power to the processor, which transfers energy and data to the implant. MATERiALS Processing unitPolyamide Magnet casingAcrylonitrile butadiene styrene (ABS) DiMENSiONSLENGTHWiDTHDEPTH Processing unit (typical values)38 mm34 mm11.6 mm WEiGHTWEiGHT Processing unit and magnet13.9 g Specifications D1694826_1-02_EN_CP1150_UG_Radio-Cert_JAPAN.indd 1116/12/2019 3:54:03 PM 12 KANSO ® 2 SOUND PROCESSOR USER GUiDE COiL CHARACTERiSTiCSVALUE Operating voltage2.33 V Operating frequency5 MHz OPERATiNG CHARACTERiSTiCS VALUE/RANGE Sound input frequency range 100 Hz to 8 kHz Wireless technologyProprietary low power bi-directional wireless link Publish…

Text truncated - open the document above for the full version.

ID Label/Location Info

#101015 1029086 W M/N: CP1150 IC: 8039A-CP1150 FCC ID: WTO-CP1150 CMIIT ID: XXXXXXXXXX R HHHHH-AA-FFFFF IP68 CCXXxxYYyyyZzW

RF Exposure Info

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 61200RAN.002A1 2019-11-26 Test report No: NIE: 61200RAN.002A1 Assessment report RF EXPOSURE REPORT ACCORDING TO FCC 47 CFR Part 2.1093 ISED RSS -102 Issue 5:2015 (*) Identification of item under evaluation CP1150 Sound Processor (*) Trademark Cochlear (*) Model and /or type reference CP1150 Other identification of the product FCC IC: WTO-CP1150 ID: 8039A-CP1150 (*) Features Not provided data Manufacturer Cochlear LTD 1 University Avenue, Macquarie University NSW, Australia – 2109 Test method requested, standard FCC 47 CFR Part 2.1093. Radiofrequency radiation exposure evaluation: portable devices. ISED RSS-102 Issue 5 (2015-03) – Radio Frequency Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) Summary IN COMPLIANCE Approved by (name / position & signature) Miguel Lacave Antennas Lab Manager Date of issue 2019-11-26 Report template No FAN24_02 (*) “Data provided by the client” DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 61200RAN.002A1 Page 2 of 11 2019-11-26 Index Competences and guarantees .................................................................................................... 3 General conditions ...................................................................................................................... 3 Data provided by the client .......................................................................................................... 3 Identification of the client............................................................................................................. 3 Document history ........................................................................................................................ 4 General description of the device under evaluation ..................................................................... 4 Assessment summary ................................................................................................................. 4 Evaluation Results ...................................................................................................................... 5 Appendix A: FCC RF Exposure information ................................................................................ 7 FCC SAR test exclusion considerations for portable devices ................................................. 8 Appendix B: ISED RF Exposure information ............................................................................. 10 ISED SAR test exclusion considerations .............................................................................. 11 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 61200RAN.002A1 Page 3 of 11 2019-11-26 Competences and guarantees In order to assure the traceability to other national and international laboratories, DEKRA Testing and Certification S.A.U. has a calibration and maintenance program for its measurement equipment. DEKRA Testing and Certification S.A.U. guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated on the report and, it is based on the knowledge and technical facilities available at DEKRA Testing and Certification at the time of performance of the test. DEKRA Testing and Certification S.A.U. is liable to the client for the maintenance of the confidentiality of all information related to the item under test and the results of the test. The results presented in this Assessment Report apply only to the particular item under test established in this document. IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means, except in full, without the previous written permission of DEKRA Testing and Certification S.A.U. General conditions 1. This report is only referred to the item that has undergone the assessment. 2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without previous written permission of DEKRA Testing and Certification S.A.U. 4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written permission of DEKRA Testing and Certification S.A.U. and the Accreditation Bodies Data provided by the client The following data has been provided by the client: 1. Information relating to the description of the sample ("Identification of the item tested", "Trademark", "Model and/or type reference tested"). 2. Maximum output power and maximum antenna gain information. 3. CP1150 Sound Processor is part of a cochlear implant system. It is worn off the ear and its purpose is to capture and digitally process sound, as well as to transfer the audio data and power to the cochlear implant over a transcutaneous link. DEKRA Testing and Certification S.A.U. declines any responsibility with respect to the information provided by the client and that may affect the validity of results. Identification of the client COCHLEAR LTD 1 University Avenue, Macquarie University NSW, Australia – 2109 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: (NIE) 61200RAN.002A1 Page 4 of 11 2019-11-26 Document history Report number Date Description 61200RAN.002 2019-10-09 First release 61200RAN.002A1 2019-11-26 Second release. Corrected FCC ID on front page General description of the device…

Text truncated - open the document above for the full version.

Test Report

DEKRA Certification, Inc. 405 Glenn Dr. Suite 12, Sterling, VA 20164 United States of America Report No: 2602ERM.005ª2 02-26-2020 FCC LISTED, REGISTRATION NUMBER: 2764.01 ISED LISTED REGISTRATION NUMBER: 23595-1 Test report No: 2602ERM.005A2 Test report USA FCC Part 15.249, 15.209 CANADA RSS-210, RSS-Gen Radio Frequency Devices. Operation within the bands 902 - 928 MHz, 2400 -2483.5 MHz, and 5725 - 5850 MHz. Identification of item tested CP1150 Sound Processor Trademark Cochlear Model and /or type reference CP1150 Other identification of the product FCC ID: WTO-CP1150 IC: 8039A-CP1150 HW Version: Build W SW Version: 0922B02T00 (02.02.00#766564) Features --- Manufacturer Cochlear LTD 1 University Avenue, Macquarie University, NSW, Australia – 2109. Test method requested, standard USA FCC Part 15.249 10-1-18 Edition: Operation within the bands 902 - 928 MHz, 2400 -2483.5 MHz, 5725 - 5875 MHz, and 24.0 – 24.25 GHz. USA FCC Part 15.209 10-1-18 Edition: Radiated emission limits; general requirements. CANADA RSS-210 Issue 9 (August 2016). CANADA RSS-Gen Issue 5 (April 2018). ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices. Summary IN COMPLIANCE Approved by (name / position & signature) Domingo Galvez EMC&RF Lab Manager Date of issue 02-26-2020 Report template No FDT08_21 DEKRA Certification, Inc. 405 Glenn Dr. Suite 12, Sterling, VA 20164 United States of America Report No: 2602ERM.005ª2 Page 2 of 30 02-26-2020 Index Competences and guarantees .................................................................................................... 3 General conditions ...................................................................................................................... 3 Uncertainty ................................................................................................................................. 3 Data provided by the client .......................................................................................................... 4 Usage of samples ....................................................................................................................... 4 Test sample description .............................................................................................................. 5 Identification of the client............................................................................................................. 6 Testing period and place ............................................................................................................. 6 Document history ........................................................................................................................ 6 Modifications to the reference test report .................................................................................... 7 Environmental conditions ............................................................................................................ 7 Remarks and comments ............................................................................................................. 8 Testing verdicts ........................................................................................................................... 8 Summary .................................................................................................................................... 8 List of equipment used during the test......................................................................................... 9 Appendix A: Test results (Proprietary Protocol 2.4GHz) ............................................................ 10 DEKRA Certification, Inc. 405 Glenn Dr. Suite 12, Sterling, VA 20164 United States of America Report No: 2602ERM.005ª2 Page 3 of 30 02-26-2020 Competences and guarantees DEKRA Certification Inc. is a testing laboratory accredited by A2LA (The American Association for Laboratory Accreditation), to perform the tests indicated in the Certificate 2764.01 DEKRA Certification Inc. is a testing laboratory competent to carry out the tests described in this report. In order to assure the traceability to other national and international laboratories, DEKRA Certification Inc. has a calibration and maintenance program for its measurement equipment. DEKRA Certification Inc. guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated on the report and, it is based on the knowledge and technical facilities available at DEKRA Certification at the time of performance of the test. DEKRA Certification Inc. is liable to the client for the maintenance of the confidentiality of all information related to the item under test and the results of the test. The results presented in this Test Report apply only to the item under test established in this document. IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means, except in full, without the previous written permission of DEKRA Certification Inc. General conditions 1. This report is only referred to the item that has undergone the test. 2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without previous written permission of DEKRA Certification Inc. 4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written permission of DEKRA Certification Inc. and the Accreditation Bodies. Uncertainty Uncertainty (factor k=2) was calculated according to the DEKRA Certification internal document PODT000. Frequency (MHz) U(k=2) Units 30-180 3.82 dB 180-1000 2.61 dB 1000-18000 2.92 dB 18000-40000 2.15 dB DEKRA Certification, Inc. 405 Glenn Dr. Suite 12, Sterling, VA 20164 United States of Ame…

Text truncated - open the document above for the full version.

Test Setup Photos

DEKRA Certification, Inc. 405 Glenn Dr. Suite 12, Sterling, VA 20164 United States of America Report No: 2602ERM.005A2 12-03-2019 Appendix B: Photographs DEKRA Certification, Inc. 405 Glenn Dr. Suite 12, Sterling, VA 20164 United States of America Report No: 2602ERM.005A2 Page 2 of 4 12-03-2019 Figure B1. DUT Front View Figure B2. DUT Rear View DEKRA Certification, Inc. 405 Glenn Dr. Suite 12, Sterling, VA 20164 United States of America Report No: 2602ERM.005A2 Page 3 of 4 12-03-2019 Figure B3. Radiated DUT Sample Figure B4. Radiated Setup 1 DEKRA Certification, Inc. 405 Glenn Dr. Suite 12, Sterling, VA 20164 United States of America Report No: 2602ERM.005A2 Page 4 of 4 12-03-2019 Figure B5. Radiated Setup 2

Contact Information

Applicant

Steven Kennedy(Global Head of Regulatory)
[email protected]+61294286555Fax: +61296115437

Test Firm

DEKRA Certification, Inc.Jose Fernandez
[email protected]703 657 2004

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term
Grant Notes
This device meets the SAR Test Exclusion threshold specified in KDB447498 and since then, it is authorized for portable operation. Multi-transmitter configurations, supporting simultaneous transmission, have been evaluated as described in this filling. Other multi-transmitter configurations have not been evaluated and shall be evaluated according to KDB Publication 447498 and §2.947(f), §15.31(h) and §15.31(k) composite system and §2.1 terms and concepts.

Other Applications from Cochlear Limited

Nucleus 8 Processing Unit - FCC ID WTO-CP1110 - Cochlear Limited
WTO-CP1110

Nucleus 8 Processing Unit

Dec 01, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
SOUND PROCESSOR - FCC ID WTO-CP950 - Cochlear Limited
WTO-CP950

SOUND PROCESSOR

Nov 23, 2015

Equipment Class

DTS - Digital Transmission System