FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Quanzhou Wouxun Electronics Co., Ltd./
  3. WVTWOUXUN19

WVTWOUXUN19Two way Radio (GMRS Radio)

Quanzhou Wouxun Electronics Co., Ltd.
Two way Radio (GMRS Radio) - FCC ID WVTWOUXUN19 - Quanzhou Wouxun Electronics Co., Ltd.
Click to zoom

Application Details

Equipment Class
CSR - Scanning Receiver
Date of Grant
Feb 18, 2021
Application Purpose
Original Equipment
Date of Application
Feb 18, 2021
Equipment Note
Two way Radio (GMRS Radio)
Frequency Range
894.00000000 - 960.00000000
Company
Quanzhou Wouxun Electronics Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

C = CALL S = EARS/Safety E = EMER/Prepper T = Travel r = Repeater –– Default Channel Programming Chart –– The following factory/default channels are restored after performing a RESET ALL function [MENU 61_RESET | ALL]. –– Feature Differences –– The following features available in the original KG-UV9P have been removed or modified to comply with FCC GMRS regulations. •Cross-Band Repeater: Removed; Not allowed on GMRS. •− Shift Direction: GMRS repeaters are positive offset only. •+ Shift Direction: Allowed only on GMRS repeater pairs. •Power Levels: Restricted on some frequencies per FCC. Ch. 1-7 (H) | Ch. 8-14 (L only) | Ch. 15-30 (H) L = 0.5 Watts | M = 2 Watts | H = 5 Watts –– Feature Additions & Improvements –– The following features have been added or improved upon from the original KG-UV9P. •Scanning Advance: When scanning in TO or CO Scan Modes [ MENU 28_SC–REV], you can now rotate the Channel Knob in either direction to immediately advance/resume scanning when you’ve encountered an unwanted signal. See Scanning section on page 4 for more details. –– Basic Operation –– •Key Presses: The PF2 & PF3 side-keys and several front panel keypad keys allow short and long presses to access primary & secondary functions (such as ✱ for the REV/SCAN functions — see the Programmable Function Keys section on the reverse). •A “long-press” involves holding down a key for about 1–2 seconds to activate the alternate key function, rather than a momentary “short-press” for the primary key function. KG-UV9G GMRS Two-Way Radio Transceiver & Scanner FCC PART 95E Certified FCC ID: WVTWOUXUN19 FCC PART 95 Warning This device operates on GMRS (General Mobile Radio Service) frequencies, which require an FCC (Federal Communications Commission) license. You must be licensed prior to transmitting on these frequencies. Serious penalties could result for unlicensed use of GMRS frequencies in violation of FCC rules, as stipulated in the Communications Act’s Sections 501 and 502 (amended). You will be issued a call sign by the FCC, which should be used for station identification when operating the radio on GMRS frequencies. You should also cooperate by engaging in permissible transmissions only, avoiding channel interference with other GMRS users, and being prudent with the length of your transmission time. To obtain a license or ask questions about the license application, contact the FCC at 1-888-CALL-FCC or go to the FCC's website: http://www.fcc.gov and request form 605. Thank you and congratulations on purchasing the most advanced GMRS Two-Way Radio & Scanner ever made. The WOUXUN KG-UV9G is built upon the trusted performance, proven design and quality manufacturing of the KG-UV9D(Plus) and KG-UV9P amateur radios. It has been modified to comply with FCC GMRS specifications and regulations to deliver unparalleled recreational, EmComm and SHTF communications & scanning. ATTENTION Please read this entire manual addendum as it contains important safety and compliance information for the proper handling and operation of your new GMRS radio. The information in this addendum supersedes and highlights differences between the enclosed original KG-UV9P manual and this new KG-UV9G model. COMPLIANCE Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with PART 15B of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. WARNING: MODIFICATION OF THIS DEVICE TO RECEIVE CELLULAR RADIOTELEPHONE SERVICE SIGNALS IS PROHIBITED UNDER FCC RULES AND FEDERAL LAW. This device meets the requirements of FCC PART 15.121(b) for scanning receivers in the following frequency ranges (MHz): 76-108 / 108-136 136-180 / 230-250 / 350-400 / 400-512 / 700-824 / 849-869 / 894-960. FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 2.5 cm between the radiator and your body. The antenna used for this device must not be co-located or operating in conjunction with any other antenna or transmitter. The device is authorized to operate at a duty factor not exceed 50% CH #CH NameRX Freq.TX Freq. TX CTCSS TX PWR BW kHz Scan 001 GMRS 01C 462.5625 462.5625 141.3 H 25 ON 002 GMRS 02S462.5875462.5875210.7 H25 ON 003 GMRS 03E462.6125462.6125141.3 H25 ON 004 GMRS 04462.6375462.6375141.3 H25 ON 005 GMRS 05462.6625462.6625141.3 H25 ON 006 GMRS 06462.6875462.6875141.3 H25 ON 007 GMRS 07462.7125462.7125141.3 H25 ON 008 GMRS 08467.5675467.5675141.3L 12.5 ON 009 GMRS 09467.5875467.5875141.3L 12.5 ON 010 GMRS 10467.6125467.6125141.3L 12.5 ON 011 GMRS 11467.6375467.6375141.3L 12.5 ON 012 GMRS 12467.6625467.6625141.3L 12.5 ON 013 GMRS 13467.6875467.6875141.3L 12.5 ON 014 GMRS 14467.7125467.7125141.3L 12.5 ON 015 GMRS 15C462.550462.550141.3H 25 ON 016 GMRS 16S462.575462.575210.7H 25 ON 017 GMRS 17E462.600462.600141.3H 25 ON 018 GMRS 18462.625462.625141.3H 25 ON 019 GMRS 19462.650462.650141.3H 25 ON 020 GMRS 20T462.675462.675141.3H 25 ON 021 GMRS 21462.700462.700141.3H 25 ON 022 GMRS 22462.725462.725141.3H 25 ON 023 GMRSr15C462.550467.550141.3H 25 OFF 024 GMRSr16S462.575467.575210.7H 25 OFF 025 GMRSr17E462.600467.600141.3H 25 OFF 026 GMRSr18462.625467.625141.3H 25 OFF 027 GMRSr19462.650467.650141.3H 25 OFF 028 GMRSr20T462.675467.675141.3H 25 OFF 029 GMRSr21462.700467.700141.3H 25 OFF 030 GMRSr22462.725467.725141.3H 25 OFF Station ID Your GMRS station call sign must be transmitted using voice in the English language, or with intl. Morse code telegraphy using an audible tone: (a) Following a single transmission or a series of transmissions; and (b) After 15 minutes and at least once every 15 minutes thereafter during a serie…

Text truncated - open the document above for the full version.

Attestation Statements

Company: Quanzhou Wouxun Electronics Co., Ltd. Add: Jiangnan High Technology Industry Park, No.928 Nanhuan Road, Quanzhou, Fujian, China Tel: 86-595-28051265 Fax: 86-595-28051267 E-mail: [email protected] DECLARATION Signature: Typed or Printed Name: Danny Chen Title: Manager 2020-07-02 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Declaration of compliance to the requirements of §15.121 FCC ID: WVTWOUXUN19 Dear Sir or Madam: We declare that, this scanning receiver is incapable of operating (tu ning), or readily being altered by the users to operate, within the frequency bands allocated to the Cellular Radiotelephone Service in part 22 of this chapter (cellular telephone bands). This device will not b e able to receive transmissions in the cellular telephone bands by means of clipping the leads of, or installing, a simple component such as a diode, resistor or jumper wire; replacing a plug-in semicond uctor chip; or programming a semiconductor chip using special access codes or an external device, such as a personal computer. This device is also incapable of converting digital cellular communication transmissions to analog voice audio. This device is designed so that the tuning, control and filtering circuitry is inaccessible. Any attempts to modify the equipment to receive transmissions from the Cellular Radiotelephone Service will render the receiver inoperable. This scanning receiv er rejects any signals from the Cellular Radiotelephone Service frequency bands that are 38 dB or lower based upon a 12 dB SINAD measurement. We are aware that the modification of this device to receive transmissions from Cellular Radiotelephone Service frequency bands will be considered to constitute manufacture of such equipment. This includes any individu al, individuals, entity or organization that modifies one or more scanners. Any modification to receive transmissions from the Cellular Radiotelephone Service frequency bands voids the certification of the scanning receiver, regardless of the date of manufacture of the o riginal unit. Sincerely,

Cover Letter(s)

Company: Quanzhou Wouxun Electronics Co., Ltd. Add: Jiangnan High Technology Industry Park, No.928 Nanhuan Road, Quanzhou, Fujian, China Tel: 86-595-28051265 Fax: 86-595-28051267 E-mail: [email protected] 6LJQDWXUH 7\SHGRU3ULQWHG1DPHDanny Chen 7LWOHManager '(&/$5$7,21 'DWH2020-07-02 )('(5$/&20081,&$7,216&200,66,21 $XWKRUL]DWLRQDQG(YDOXDWLRQ'LYLVLRQ 2DNODQG0LOOV5RDG &ROXPELD0' 'HDU6LURU0DGDP :H Quanzhou Wouxun Electronics Co., Ltd.KHUHE\GHFODUHWKDWSURGXFWQDPH Two way Radio(GMRS radio) PRGHOQDPHKG-UV9G, KG-UV9G(Plus), KG-UV9GX, KG-UV9GW. FCC ID: WVTWOUXUN19). These models are identical with the PCB d esign, components and electromagnetics compatibility characteristics. KG-UV9G has been tested by BACL. 7KHGLIIHUHQFHVRIWKHPDUHDVIROORZV 0RGHOQDPH 3OHDVHFRQWDFWPHLIWKHUHLVQHHGIRUDQ\DGGLWLRQDOFODULILFDWLRQRULQIRUPDWLRQ %HVW5HJDUGV

Cover Letter(s)

QA-FR-171-A Company: Quanzhou Wouxun Electronics Co., Ltd. Add: Jiangnan High Technology Industry Park, No.928 Nanhuan Road, Quanzhou, Fujian, China Tel: 86-595-28051265 Fax: 86-595-28051267 E-mail: [email protected] FCC Confidential Authorization 2020-07-02 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: WVTWOUXUN19 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Quanzhou Wouxun Electronics Co., Ltd., hereby requests long-term confidential treatment of information accompanying this application as outlined below: •Block Diagram •Schematics •Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature: Typed or Printed Name: Danny Chen Title: Manager • BOM/Tune-up • INTERNAL PHOTOGRAPHS

External Photos

EXHIBIT A - EUT EXTERNAL PHOTOGRAPHS UHF Antenna

Test Report

FCC PART 15B MEASUREMENT AND TEST REPORT For Quanzhou Wouxun Electronics Co., Ltd. Jiangnan High Technology Industry Park, No.928 Nanhuan Road, Quanzhou, Fujian, China R e p o r t Ty p e : O r i g i n a l R e p o r t Product Type: Tw o way Radio(GMRS radio) Project Engineer: Jett Zhao Report Number: RXM200702050-00A Report Date: 2020-10-12 Reviewed By: Oscar Ye EMC Manager Prepared By: Bay Area Compliance Laboratories Corp. (Kunshan) No.248 Chenghu Road, Kunshan,Jiangsu province, China Tel: +86-0512-86175000 Fax: +86-0512-88934268 www.baclcorp.com.cn FCC ID: WVTWOUXUN19 Bay Area Compliance Laboratories Corp. (Kunshan) Report No.: RXM200702050-00A FCC Part 15B Page 2 of 83 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 3 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 3 OBJECTIVE ................................................................................................................................................................... 3 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................. 3 TEST METHODOLOGY .................................................................................................................................................. 3 TEST FACILITY ............................................................................................................................................................. 4 SYSTEM TEST CONFIGURATION .......................................................................................................................... 5 JUSTIFICATION ............................................................................................................................................................. 5 EUT EXERCISE SOFTWARE .......................................................................................................................................... 5 SPECIAL ACCESSORIES ................................................................................................................................................. 5 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 5 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 6 BLOCK DIAGRAM OF RADIATED TEST SETUP............................................................................................................... 7 SUMMARY OF TEST RESULTS ............................................................................................................................... 8 FCC §15.107 – CONDUCTED EMISSIONS .............................................................................................................. 9 APPLICABLE STANDARD .............................................................................................................................................. 9 MEASUREMENT UNCERTAINTY .................................................................................................................................... 9 EUT SETUP .................................................................................................................................................................. 9 EMI TEST RECEIVER SETUP ....................................................................................................................................... 10 TEST PROCEDURE ...................................................................................................................................................... 10 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 10 FACTOR & OVER LIMIT CALCULATION ...................................................................................................................... 10 TEST DATA ................................................................................................................................................................ 11 FCC §15.109 - RADIATED EMISSIONS ................................................................................................................. 13 APPLICABLE STANDARD ............................................................................................................................................ 13 MEASUREMENT UNCERTAINTY .................................................................................................................................. 13 EUT SETUP ................................................................................................................................................................ 13 EMI TEST RECEIVER SETUP ....................................................................................................................................... 14 TEST PROCEDURE ...................................................................................................................................................... 14 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 15 FACTOR & OVER LIMIT CALCULATION – FOR BELOW 1GHZ .................................................................................... 15 CORRECTED AMPLITUDE & MARGIN CALCULATION – FOR BELOW 1GHZ & ABOVE 1GHZ ..................................... 16 TEST DATA ................................................................................................................................................................ 16 FCC §15.111 - ANTENNA CONDUCTED P…

Text truncated - open the document above for the full version.

Test Setup Photos

EXHIBIT C - TEST SETUP PHOTOGRAPHS Test mode 1 Conducted Emissions - Front Side Conducted Emissions - Rear Side Radiated Disturbances Front Side (Below 1GHz) Radiated Disturbances Rear Side (Below 1GHz) Radiated Disturbances Side View (Above 1GHz) Test mode 2 Radiated Disturbances Front Side (Below 1GHz) Radiated Disturbances Rear Side (Below 1GHz) Radiated Disturbances Side View (Above 1GHz)

Contact Information

Applicant

Danny Chen(Manager)
[email protected]86-595-28051265Fax: 86-595-28051267

Test Firm

Bay Area Compliance Laboratories Corp. (Kunshan)Mr. John Chan
[email protected]+86 0512 86175000

Technical Specifications

#Rule PartsFrequency RangePower Output
915B894 MHz - 960 MHz-
Confidentiality
Long Term

Other Applications from Quanzhou Wouxun Electronics Co., Ltd.

TWO WAY RADIO (GMRS RADIO) - FCC ID WVTWOUXUN26 - Quanzhou Wouxun Electronics Co., Ltd.
WVTWOUXUN26

TWO WAY RADIO (GMRS RADIO)

Aug 02, 2021

Equipment Class

CSR - Scanning Receiver
Two way Radio( MURS radio) - FCC ID WVTWOUXUN24 - Quanzhou Wouxun Electronics Co., Ltd.
WVTWOUXUN24

Two way Radio( MURS radio)

Jun 01, 2021

Equipment Class

CSR - Scanning Receiver
TWO-WAY RADIOS - FCC ID WVTWOUXUN23 - Quanzhou Wouxun Electronics Co., Ltd.
WVTWOUXUN23

TWO-WAY RADIOS

Apr 20, 2021

Equipment Class

CSR - Scanning Receiver
TWO-WAY RADIOS - FCC ID WVTWOUXUN21 - Quanzhou Wouxun Electronics Co., Ltd.
WVTWOUXUN21

TWO-WAY RADIOS

Feb 23, 2021

Equipment Class

CSR - Scanning Receiver
TWO-WAY RADIOS - FCC ID WVTWOUXUN18 - Quanzhou Wouxun Electronics Co., Ltd.
WVTWOUXUN18

TWO-WAY RADIOS

Feb 18, 2021

Equipment Class

TNF - Licensed Non-Broadcast Transmitter Held to Face