Attestation Statement Letter I Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Date: __________________ Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC Application for FCC ID: _______________________________ ________________________ certifies that the equipment for which authorization is sought is not “covered” equipment prohibited for receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Applicant’s Signature: Applicant’s Name:
Attestation Statement Letter II Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: __________________ Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC Application for FCC ID: _______________________________ _________________________ certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Applicant’s Signature: Applicant’s Name:
Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: ________________ Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Type of Confidentiality Requested Exhibit Type ☐Short Term ☐Permanent Block Diagrams ☐Short Term External Photos ☐Short Term ☐Permanent* Internal Photos ☐Short Term ☐Permanent Operation Description ☐Short Term ☐Permanent Parts List/BOM ☐Short Term ☐Permanent Schematics ☐Short Term Test Setup Photos ☐Short Term ☐Permanent* User manual *Requires further justification before permanent confidentiality will be allowed. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request temporary confidential treatment of information accompanying this application as outlined below for an initial period of ____________ days. Sincerely, Client’s signature: ________________________________ Client’s name & title: _____________________________ Contact information / address:
FCC Agent Authorization Letter Date: __________________ SUBJECT: FCC Application for FCC ID: _______________________________ To Whom It May Concern: We, the undersigned, hereby authorize _________________________________________ in _____________________________________________ on our behalf, to apply to the Federal Communications Commission for our equipment. Any and all acts carried out by _____________________________________________ on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, Client’s signature: ________________________________ Client’s name & title: _____________________________ Contact information / address: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046
WY2703AC6 WY2703AC6
Page 1 of 3 Report No.: CTC2026281306 CTC Laboratories, Inc. Room 107, 108, 207, 208 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF No:CTC-TR-066_A5 Master TRF:Dated 2026-06-01 Maximum Permissible Exposure Evaluation FCC ID: WY2703AC6 According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) Radiation as specified in §1.1307(b). EUT Specification Product Name: COCKPIT DOMAIN CONTROLLER Trade Mark: clarion Model/Type Reference: 703AC6 Model Differences: / Frequency Band (Operating) BT: 2402MHz ~ 2480MHz BLE: 2402MHz ~ 2480MHz WLAN: 2412MHz ~ 2462MHz U-NII-1: 5180MHz ~ 5240MHz U-NII-3: 5745MHz ~ 5825MHz Device Category Portable (<5mm separation) Mobile (>20cm separation) Fixed (>20cm separation) Others ___ Exposure Classification Occupational/Controlled exposure (S=5mW/cm 2 ) General Population/Uncontrolled exposure (S=1mW/cm 2 ) Antenna Diversity Single antenna Multiple antennas Tx diversity Rx diversity Tx/Rx diversity Antenna Gain (Max) BLE/BT: 2.9dBi WLAN: 3.32dBi U-NII-1: 4.55dBi U-NII-3: 3.23dBi Evaluation Applied MPE Evaluation SAR Evaluation Page 2 of 3 Report No.: CTC2026281306 CTC Laboratories, Inc. Room 107, 108, 207, 208 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF No:CTC-TR-066_A5 Master TRF:Dated 2026-06-01 Limits for Maximum Permissible Exposure (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) (A) Limits for Occupational/Controlled Exposure 300-1500----F/300<6 1500-100000----5<6 (B) Limits for General Population/Uncontrolled Exposure 300-1500----F/1500<30 1500-100000----1<30 Calculation Method Friis transmission formula: Pd=(P out *G)/(4*Pi*R 2 ) Where: Pd= Power density in mW/cm 2 P out = output power to antenna in mW G= gain of antenna in linear scale Pi= 3.1416 R= distance between observation point and center of the radiator in cm Pd limit of MPE is 1mW/cm 2 . If we know the maximum gain of the antenna and total power input to the antenna, through the calculation, we will know the distance where the MPE limit is reached. Measurement Result Mode Frequency (MHz) Antenna Gain (dBi) Maximum Power (dBm) Max. Tune Up Power (dBm) Power Density at 20cm (mW/cm 2 ) Limit (mW/cm 2 ) BT/EDR24412.98.7290.003081 1 BLE24402.94.034.50.001093 1 WLAN 802.11b24373.3216.71170.021416 1 WLAN 802.11g24373.3213.1413.50.009566 1 WLAN 802.11n(HT20) 24373.3210.98110.005380 1 WLAN 802.11n(HT40) 24373.3211.1811.50.006036 1 RLAN U-NII-1 802.11a 52004.5518.55190.045055 1 RLAN U-NII-1 802.11n(HT20) 52004.5518.2618.50.040155 1 RLAN U-NII-1 802.11n(HT40) 52304.5514.78150.017937 1 RLAN U-NII-1 802.11ac(VHT20) 52404.5517.4217.50.031896 1 RLAN U-NII-1 802.11ac(VHT40) 52304.5516.92170.028428 1 RLAN U-NII-1 802.11ac(VHT80) 52104.5514.2214.50.015986 1 RLAN U-NII-3 802.11a 58253.2313.56140.010513 1 RLAN U-NII-3 802.11n(HT20) 58253.2313.3413.50.009370 1 Page 3 of 3 Report No.: CTC2026281306 CTC Laboratories, Inc. Room 107, 108, 207, 208 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF No:CTC-TR-066_A5 Master TRF:Dated 2026-06-01 RLAN U-NII-3 802.11n(HT40) 57553.2312.4912.50.007443 1 RLAN U-NII-3 802.11ac(VHT20) 58253.2313.2913.50.009370 1 RLAN U-NII-3 802.11ac(VHT40) 57553.2312.4712.50.007443 1 RLAN U-NII-3 802.11ac(VHT80) 57753.2311.76120.006634 1 The WLAN and BT can transmit simultaneously. RLAN Power density at 20cm (mW/cm 2 ) BT Power density at 20cm (mW/cm 2 ) Total Power density at 20cm (mW/cm 2 ) Power density Limit (mW/cm 2 ) 0.0450550.003081 0.0481361 Note: 1. Calculate in the worst-case mode. 2. Max. Tune Up Power is declared by manufacturer, and used to calculate. 3. For a more detailed features description, please refer to the RF Test Report. **********************THE END**********************
Page 85 of 111 Report No.: CTC2026281305 CTC Laboratories, Inc. Room 107, 108, 207, 208 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF No:CTC-TR-062_A5 Master TRF:Dated 2026-06-01 11AC20SISO_Ant1_5240 11AC20SISO_Ant1_5745 11AC20SISO_Ant1_5785 Page 86 of 111 Report No.: CTC2026281305 CTC Laboratories, Inc. Room 107, 108, 207, 208 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF No:CTC-TR-062_A5 Master TRF:Dated 2026-06-01 11AC20SISO_Ant1_5825 11AC40SISO_Ant1_5190 11AC40SISO_Ant1_5230 Page 87 of 111 Report No.: CTC2026281305 CTC Laboratories, Inc. Room 107, 108, 207, 208 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF No:CTC-TR-062_A5 Master TRF:Dated 2026-06-01 11AC40SISO_Ant1_5755 11AC40SISO_Ant1_5795 11AC80SISO_Ant1_5210 Page 88 of 111 Report No.: CTC2026281305 CTC Laboratories, Inc. Room 107, 108, 207, 208 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF No:CTC-TR-062_A5 Master TRF:Dated 2026-06-01 11AC80SISO_Ant1_5775 6dB Bandwidth: 11A_Ant1_5745 11A_Ant1_5785 Page 89 of 111 Report No.: CTC2026281305 CTC Laboratories, Inc. Room 107, 108, 207, 208 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF No:CTC-TR-062_A5 Master TRF:Dated 2026-06-01 11A_Ant1_5825 11N20SISO_Ant1_5745 11N20SISO_Ant1_5785 Page 90 of 111 Report No.: CTC2026281305 CTC Laboratories, Inc. Room 107, 108, 207, 208 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF No:CTC-TR-062_A5 Master TRF:Dated 2026-06-01 11N20SISO_Ant1_5825 11N40SISO_Ant1_5755 11N40SISO_Ant1_5795 Page 91 of 111 Report No.: CTC2026281305 CTC Laboratories, Inc. Room 107, 108, 207, 208 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF No:CTC-TR-062_A5 Master TRF:Dated 2026-06-01 11AC20SISO_Ant1_5745 11AC20SISO_Ant1_5785 11AC20SISO_Ant1_5825 Page 92 of 111 Report No.: CTC2026281305 CTC Laboratories, Inc. Room 107, 108, 207, 208 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF No:CTC-TR-062_A5 Master TRF:Dated 2026-06-01 11AC40SISO_Ant1_5755 11AC40SISO_Ant1_5795 11AC80SISO_Ant1_5775 Page 93 of 111 Report No.: CTC2026281305 CTC Laboratories, Inc. Room 107, 108, 207, 208 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF No:CTC-TR-062_A5 Master TRF:Dated 2026-06-01 Page 94 of 111 Report No.: CTC2026281305 CTC Laboratories, Inc. Room 107, 108, 207, 208 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF No:CTC-TR-062_A5 Master TRF:Dated 2026-06-01 3.4. Output Power Limit FCC CFR Title 47 Part 15 Subpart E Section 15.407(a) Test Item Limit Frequency Range (MHz) Conducted Output Power Fixed: 1 Watt (30dBm) Mobile and Portable: 250mW (24dBm) 5150~5250 250mW (24dBm) 5250~5350 250mW (24dBm) 5500~5700 1 Watt (30dBm) 5725~5850 Test Configuration Test Procedure The measurement is according to section 3 of KDB 789033 D02 General UNII Test Procedures New Rules V02r01. Test Mode Please refer to the clause 2.4. Page 95 of 111 Report No.: CTC2026281305 CTC Laboratories, Inc. Room 107, 108, 207, 208 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF No:CTC-TR-062_A5 Master TRF:Dated 2026-06-01 Test Result Test Mode Antenna Freq (MHz) Conducted power Result [dBm] Conducted power Limit [dBm] Verdict 11A Ant1 5180 18.20 ≤30.00 PASS Ant1 5200 18.55 ≤30.00 PASS Ant1 5240 18.39 ≤30.00 PASS Ant1 5745 13.10 ≤30.00 PASS Ant1 5785 13.43 ≤30.00 PASS Ant1 5825 13.56 ≤30.00 PASS 11N20SISO Ant1 5180 17.94 ≤30.00 PASS Ant1 5200 18.26 ≤30.00 PASS Ant1 5240 18.20 ≤30.00 PASS Ant1 5745 12.81 ≤30.00 PASS Ant1 5785 13.23 ≤30.00 PASS Ant1 5825 13.34 ≤30.00 PASS 11N40SISO Ant1 5190 14.35 ≤30.00 PASS Ant1 5230 14.78 ≤30.00 PASS Ant1 5755 12.49 ≤30.00 PASS Ant1 5795 12.43 ≤30.00 PASS 11AC20SISO Ant1 5180 17.04 ≤30.00 PASS Ant1 5200 17.31 ≤30.00 PASS Ant1 5240 17.42 ≤30.00 PASS Ant1 5745 12.79 ≤30.00 PASS Ant1 5785 13.16 ≤30.00 PASS Ant1 5825 13.29 ≤30.00 PASS 11AC40SISO Ant1 5190 16.67 ≤30.00 PASS Ant1 5230 16.92 ≤30.00 PASS Ant1 5755 12.47 ≤30.00 PASS Ant1 5795 12.42 ≤30.00 PASS 11AC80SISO Ant1 5210 14.22 ≤30.00 PASS Ant1 5775 11.76 ≤30.00 PASS Page 96 of 111 Report No.: CTC2026281305 CTC Laboratories, Inc. Room 107, 108, 207, 208 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: …
Text truncated - open the document above for the full version.
1 Copyright © by Passive System Alliance | All rights reserved. 2 Copyright © by Passive System Alliance | All rights reserved. 3 歌乐ICAR05_WIFI Antenna _Test Report Presented by: Guangmang _Chen 华南研发 Checked by :A pple_Zhao Approved by :Kevin_yang INPAQ Technology Co., Ltd. Copyright © by Passive System Alliance | All rights reserved. Last updated in M ay .21th, 2025 4 Contents Revised History Requirements of Antenna Design and Measurement Antenna Placement & Solution Return Loss&IsolationResults 3DRadiation Pattern Results 2DRadiation Pattern Results Results Summary (peak gain , efficiency ) OTA Conclusion 5 Revision History Released Date VersionRecord Apr.11 th ,2025 V0.0 天线测试报告 Apr.15 th ,2025 V0.1 天线测试报告 May.16 th ,2025 V0.2 天线测试报告 May.21 th ,2025 V0.3 更新天线 OTA 测试报告 6 Requirements of Antenna Design and Measurement Requirements of Antenna Design Requirements of Measurement RF Function Number of ANTFrequency BandRemark WiFi2 2400-2500MHz , 5150-5850MHz WIFI , BT Test ItemSpecificationRemark VSWRN/A Peak gainN/A EfficiencyN/A 7 Antenna Placement & Solution BT WIFI front back BT WIFI 8 Antenna Placement & Solution WIFI BT 9 Antenna Matching Network-WIFI 客户匹配 10 Antenna Matching Network-BT 客户匹配 11 Return Loss Results-WIFI Frequency ( MHz ) 2400 2450 2500 5150 5850 Return Loss (dB)-14 -21 -32 -10 -12 12 Return Loss Results-BT Frequency ( MHz ) 240024502500 Return Loss (dB)-26-16-12 13 Isolation Results WIFI & BT Frequency ( MHz ) 2400 2450 2500 5150 5850 Isolation (dB) -23 -22 -21 -41 -36 14 Test Setup for Radiation Pattern Measurement AUT Thet a Ph i Dual Polarization Horn Antenna Z Y X ETS Ams-8600 12.91x3.05x3.05 m3 Tapered Chamber QUIPMENTBRANDMODULE TYPE SpectrumAgilentE4402B Signal Generator Agilent8960 SwitchAgilent3499A SwitchETS2090 Network Analyzer AgilentN5230A Figure 1: System diagram for test system including compact-size tapered anechoic chamber and optional test instrumentation 15 15 3D Radiation pattern Results-WIFI 2450MHz5450MHz 16 16 3D Radiation pattern Results-BT 2450MHz 17 17 2D Radiation pattern Results-WiFi XZ-E1-planeYZ-E2-plane XY-H-plane X Z Z Y X Y 2450MHz 5450MHz Z Y X 18 18 2D Radiation pattern Results-BT XZ-E1-planeYZ-E2-plane XY-H-plane X Z Z Y X Y 2450MHz Z Y X 19 19 Results Summary-Peak Gain & Efficiency-WiFi Frequency Efficiency Efficiency Peak Gain (MHz)(dB) (%) (dBi) 2400 -3.65 43.15 3.19 2410 -3.72 42.46 2.91 2420 -3.53 44.36 3.32 2430 -3.48 44.87 3.11 2440 -3.45 45.18 3.22 2450 -3.4 45.7 3.17 2460 -3.41 45.6 3.07 2470 -3.35 46.23 3.16 2480 -3.43 45.39 2.82 2490 -3.35 46.23 3.11 2500 -3.42 45.49 2.78 AVG-3.47 44.96 3.07 Frequency Efficiency Efficiency Peak Gain (MHz)(dB) (%) (dBi) 5150 -6.2 23.98 3.16 5200 -5.59 27.61 4.55 5250 -5.02 31.47 3.87 5300 -5.05 31.26 3.42 5350 -4.59 34.75 4.19 5400 -4.86 32.66 3.84 5450 -5.17 30.41 2.91 5500 -4.93 32.14 2.14 5550 -4.99 31.69 2.23 5600 -4.84 32.81 2.72 5650 -4.78 33.26 2.54 5700 -4.79 33.18 2.82 5750 -4.43 36.05 3.23 5800 -4.84 32.81 2.98 5850 -4.95 31.98 2.73 AVG-5.01 31.73 3.15 20 20 Results Summary-Peak Gain & Efficiency-BT Frequency Efficiency Efficiency Peak Gain (MHz)(dB) (%) (dBi) 2400 -3.29 46.88 2.9 2410 -3.29 46.88 2.36 2420 -3.19 47.97 2.71 2430 -3.26 47.21 2.41 2440 -3.3 46.77 2.5 2450 -3.36 46.13 2.51 2460 -3.4 45.71 2.46 2470 -3.44 45.29 2.59 2480 -3.56 44.05 2.19 2490 -3.58 43.85 2.28 2500 -3.7 42.65 1.67 AVG-3.39 45.76 2.41 21 21 OTA MODE CHANNEL TRPTIS WIFIB(11M/11M) 114.41-85.68 714.72-84.59 1114.81-84.31 WIFIA(6M/54M) 3611.72-66.16 14914.26-71.09 16513.4-71.49 BT(2-DH5) 0-0.26-86.06 391.12-86.85 78-0.11-85.44 22 Conclusion 1. 以上为板载天线测试数据。 以上请悉知,谢谢 ! 23 本資料均屬機密,僅供指定之收件人使用,未經寄件人許可不得揭露、複製或散佈本信件。 This message and any attachments are confidential and may be legally privileged. Any unauthorized review, use or distribution by anyone other than the intended recipient is strictly prohibited. If you are not the intended recipient, please immediately notify the sender, completely delete this documents, and destroy all copies. Your cooperation will be highly appreciated.
CTC Laboratories, Inc. Room 107, 108, 207, 208 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF No:CTC-TR-062_A5 Master TRF:Dated 2026-06-01 TEST REPORT Report No. .................................... : CTC2026281305 FCC ID ........................................... : WY2703AC6 Applicant ...................................... : Faurecia Clarion Electronics (Xiamen) Co., Ltd. Address .......................................... : 6F, No.40, Guanri Road, Software Park Stage II, Xiamen, China Manufacturer..................................: Faurecia Clarion Electronics (Xiamen) Co., Ltd. Address .........................................: 6F, No.40, Guanri Road, Software Park Stage II, Xiamen, China Product Name ............................ : COCKPIT DOMAIN CONTROLLER Trade Mark .................................... : clarion Model/Type reference .................... : 703AC6 Listed Model ................................ : / Standard ....................................... : FCC CFR Title 47 Part 15 Subpart E Section 15.407 Test Report Form No ..................... : CTC-TR-062_A5 Master TRF ................................... : Dated 2026-06-01 Date of receipt of test sample........: Jun. 2, 2026 Date of testing..............................: Jun. 2, 2026~ Jun. 18, 2026 Date of issue................................: Jul. 1, 2026 Result............................................: PASS Compiled by: (Printed name+signature) Alicia Liu Supervised by: (Printed name+signature) Eric Zhang Approved by: (Printed name+signature) Totti Zhao This test report may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by CTC. The test result in the report only apply to the tested sample. The test report shall be invalid without all the signatures of testing engineers, reviewer and approver.Any objections must be raised to CTC within 15 days since the date when the report is received. It will not be taken into consideration beyond this limit. Page 2 of 111 Report No.: CTC2026281305 CTC Laboratories, Inc. Room 107, 108, 207, 208 of Building A, Room 101 of Building B, No.7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn TRF No:CTC-TR-062_A5 Master TRF:Dated 2026-06-01 Table of Contents Page 1. TEST SUMMARY ....................................................................................................................................................... 3 1.1. TEST STANDARDS .......................................................................................................................................................... 3 1.2. REPORT VERSION ......................................................................................................................................................... 3 1.3. TEST DESCRIPTION ........................................................................................................................................................ 4 1.4. TEST FACILITY .............................................................................................................................................................. 5 1.5. MEASUREMENT UNCERTAINTY ........................................................................................................................................ 6 1.6. ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 6 2. GENERAL INFORMATION .......................................................................................................................................... 7 2.1. CLIENT INFORMATION ................................................................................................................................................... 7 2.2. GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 7 2.3. ACCESSORY EQUIPMENT INFORMATION ............................................................................................................................ 9 2.4. OPERATION STATE ...................................................................................................................................................... 10 2.5. MEASUREMENT INSTRUMENTS LIST ............................................................................................................................... 12 3. TEST ITEM AND RESULTS ........................................................................................................................................ 14 3.1. RADIATED EMISSION ................................................................................................................................................... 14 3.2. BAND EDGE EMISSIONS ............................................................................................................................................... 37 3.3. BANDWIDTH .............................................................................................................................................................. 67 3.4. OUTPUT POWER ........................................................................................................................................................ 94 3.5. POWER SPECTRAL DENSITY .......................................................................................................................................... 96 3.6. FREQUENCY STABILITY ..............................................…
Text truncated - open the document above for the full version.
3313 Verdi Dr · San Jose, Texas, 95111 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15E | 5.18 GHz - 5.24 GHz | 71.61 mW |
| 2 | 15E | 5.75 GHz - 5.83 GHz | 22.70 mW |
CAR AUDIO
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterCAR AUDIO
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Audio Display
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Audio Display
Equipment Class
DTS - Digital Transmission System
Audio Display
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter