Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Dec 21, 2008
Application Purpose
Original Equipment
Date of Application
Dec 21, 2008
Equipment Note
FLUORESCENT FIXTURE
Frequency Range
0.04500000 - 0.04500000
Company
Zhong Shan Heng Sheng Logistic Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Schematics

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

SUPER ROTATION FLUORESCENT LAMP (TF SERIES) QUALITY AND CHARACTER: Our fluorescent lamp supporters have fashionable and popular new-style. They are luxurious and elegant, beautiful and light, made in PC high class industrial plastic, assembled with high quality electronic ballast, these fluorescent lamps light up quickly as soon as switching on under super low voltage, they can be used to light in part of the room, also can be used for decorating. The optimum choice for you! PERFORMANCE: Cat. No. Volts Amps Hz P.F. Lamp Size Watts TF-408 120V AC 0.15A 60Hz 0.53 T4 8W TF-508 120V AC 0.15A 60Hz 0.53 T5 8W TF-513 120V AC 0.21A 60Hz 0.58 T5 13W TF-416 120V AC 0.23A 60Hz 0.58 T4 16W TF-420 120VAC 0.29A 60Hz 0.58 T4 20W TF-521 120VAC 0.29A 60Hz 0.58 T5 21W TF-528 120VAC 0.45A 60Hz 0.58 T5 28W TF-535 120VAC 0.50A 60Hz 0.58 T5 35W ASSEMBLY/MOUNTING INSTRUCTIONS: Lens Lampholder Power wire Adding Fixtures: Multiple fixture can be linked together for continuous runs with the enclosed connector cable. Do not connect more than 10 units. Power Wire Fluorescent Lamp Frame Male and female power connectors 1.Use template to mark screws locations. (Template is inside package), use a small drill, or nail, mark two small starter holes at the marked locations. Place the two small rubber grommets over the mounting screws. until the rubber grommets contact the bottom surface of the cabinet. Then turn the screws another 1/4 turn. The screws must be driven in straight for the fixtures to mount properly. Align the cross hole openings in the bottom plate of the fixtures over the mounting screws, and firmly slide the fixture over in one direction to lock it into place. The fixture can slide toward the front, rear, or from side to side depending on the spacing in your particular installation. The fixture should fit snugly up against the mounting surface. If not, then your screws need to be tightened a little more for an improved fit. 2.Connector the power wire. 3.The ways of disassembling and mounting the fluorescent lamp: When disassemble it, press forward and turn over upward the side of the lampshade with your thumb. When disassemble the fluorescent lamp, rotated the fluorescent lamp ninety degrees. When mount the fluorescent lamp, put the feet of the fluorescent lamp into the trough of the lampholder first, then rotate the fluorescent lamp ninety degrees. 4. Mount the lens last. Note: Handle with care to avoid breaking lamp. INSTRUCTION WWW.PILOTLIGHTING.COM LAMPE FLUORESCENTE EXTRA MINCE (SÉRIE TF) QUALITÉS ET CARACTÉRISTIQUES : Notre dispositif d'éclairage fluorescent est le luminaire préféré et le plus à la mode, de conception nouvelle. Luxueux et élégant, esthétique et léger, il est fabriqué en plastique industriel polycarbonate de haut de gamme et monté avec ballast électronique d'excellente qualité. Les lampes fluorescentes s'allument aussitôt qu'elles sont branchées sur super basse tension et peuvent être utilisées pour éclairer et décorer n'importe quelle partie d'une pièce. Elles représentent le choix optimal en matière d'éclairage de mobilier et dans les meubles de rangement. RENDEMENT : Catégorie no. Volts Ampères Hz PF Taille de lampe Watts TF-408 120 V c.a. 0,15 A 60 Hz 0,53 T4 8 W TF-508 120 V c.a. 0,15 A 60 Hz 0,53 T5 8 W TF-513 120 V c.a. 0,21 A 60 Hz 0,58 T5 13 W TF-416 120 V c.a. 0,23 A 60 Hz 0,58 T4 16 W TF-420 120 V c.a 0.29A 60Hz 0.58 T4 20W TF-521 120 V c.a 0.29A 60Hz 0.58 T5 21W TF-528 120 V c.a 0.45A 60Hz 0.58 T5 28W TF-535 120 V c.a 0.50A 60Hz 0.58 T5 35W INSTRUCTIONS DE MONTAGE ET D'ASSEMBLAGE : Verre de protection Cable d'alimentation Réflecteur Ajout de luminaires : Vous pouvez connecter plusieurs luminaires pour un montage en continu à l'aide du câble de connexion livré en option. Ne connectez pas plus de 10 unités. Cadre de l'ampoule fluorescente Connecteurs d'alimentation male et femelle Cable d'alimentation 1. Marquez les emplacements des vis à l'aide du gabarit (livré avec la lampe). Utilisez une petite perceuse ou un clou pour faire deux petits trous de démarrage aux emplacements marqués. Posez les deux petits anneaux en caoutchouc par-dessus les vis de montage. Fixez les deux deux vis de montage jusqu'à ce que les anneaux en caoutchouc soient en contact avec la surface inférieure de l'étagère/l'armoire. Donnez ensuite un quart de tour aux vis. Celles-ci doivent être poussées bien droit pour un montage correct. Alignez les fentes cruciformes dans la plaque inférieure des luminaires par-dessus les vis de montage, et faites glisser fermement le luminaire dans une direction pour le fixer bien en place. Le luminaire peut glisser vers l'avant, vers l'arrière ou d'un côté à l'autre suivant l'espacement disponible dans votre installation. Le luminaire doit s'ajuster parfaitement contre la surface de montage. Si ce n'est pas le cas, vous devez resserrer un peu plus les vis pour améliorer le réglage. 2. Connectez le câble d'alimentation. 3. Voici comment démonter et remonter l'ampoule fluorescente : pour la démonter, appuyez sur l'ampoule et tournez-la avec votre pouce de bas en haut à l'intérieur du réflecteur. Faites ensuite pivoter l'ampoule fluorescente de quatre-vingt dix degrés. Pour remonter l'ampoule fluorescente, introduisez tout d'abord les embases dans les gouttières du réflecteur, puis faites-la pivoter de quatre-vingt dix degrés. 4. Montez le verre de protection en dernier. Remarque : Manipulez avec précaution pour éviter de casser l'ampoule. LÁMPARA FLUORESCENTE SUPER DELGADA (SERIE TF) ______ CALIDAD Y CARACTERÍSTICAS: Nuestras lámparas fluorescentes de sujeción son el estilo de moda más novedoso y popular. Las lámparas son lujosas y elegantes, hermosas y livianas, fabricadas con excelente plástico industrial de policarbonato, y ensambladas con electrodos de la mejor calidad. Estas lámparas fluorescentes se encienden al instante a un voltaje muy bajo, pueden utilizarse para alumbrar cualquier parte de una habitación, y también se utilizan como decoración. Estas luces son …

Text truncated - open the document above for the full version.

Block Diagram

Input circuit circuit of Increase the voltage OSC 45k Half-bridge Inverter circuits lamp circuits circuit of over-current protection

Cover Letter(s)

Zhong Shan Heng Sheng Logistic Co., Ltd.. FCC ID: WZA-TFSLRF POWER OF ATTORNEY Dec.18, 2008 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize Waltek Services (ShenZhen) Co., Ltd. (Philo Zhong) on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Waltek Services (ShenZhen) Co., Ltd. (Philo Zhong) on our behalf shall have the same effect as acts of our own. This authorization expires on Dec.19, 2009. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. We, Zhong Shan Heng Sheng Logistic Co., Ltd., are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, Zhong Shan Heng Sheng Logistic Co., Ltd ------------------------------- Manager

External Photos

EUT - Front View EUT - Back View

ID Label/Location Info

FCC ID Label This device complies with Part 18 of the FCC Rules. The Label must not be a stick-on paper. The Label on these products must be permanently affixed to the product and readily visible at the time of purchase and must last the expected lifetime of the equipment not be readily detachable. Proposed Label Location on EUT EUT Top View/ proposed FCC Label Location This device complies with Part 18 of the FCC Rules. FCC ID : WZA-TFSLRF

Internal Photos

PCB - Front View PCB - Back View

Operational Description

Circuit Description This ballast were assemblyed with six parts: a: Input circuits, b, Increase Voltage circuit; c, OSC; d, Over-current protection circuits; e, Half-bridge inverter circuits; f, Lamp circuit. 1、Input circuit: This circuit are assmbled with fuse & EMI circuits. Fuse circuit to prevent short circuits occur when too much current, so it will not be damaged other electrical. EMC circuit: the common mode inductors and capacitors composed of EMC line, the circuit's primary role is to filter out interference conducted from the power cord & the ballast self when it was work, or interfenence from other electrical equipment. 2、Increase Voltage circuit: Ballast as a result of the operating voltage is 120V,, using voltage rectification to achieve the required voltage. 3、Oscillation circuit: triggered by the oscillation circuit and components of transformers. How it works: access to power, resistance to the capacitor for charging, in the process of charging voltage when the trigger DB3 diode voltage, the circuit began to work, the free oscillation which assembled by half-bridge oscillation transformer and transistor will be worked at the same time . 4、Over-current protection: When the half-bridge inverter circuit current is too large, over-current protection circuit through the thyristor oscillation circuit stop vibration, so that the circuit to stop working to avoid damage to other components. 5、Half-bridge inverter circuits: components by the two high-power transistor. How it works:, up and down a tube would be on & off by the role of the oscillation transformer, and the lamp will have a fixed frequendy which supplied by the output inductor & output capacitor , so the lamp would be worked properly.. 6、Lamp circuit: which assembled by coil inductors, capacitors lamp, series resonant circuit, so the lamp worked well.

Schematics

1234 A B C D 4321 D C B A 1 PL-21 1 1.0 10-Dec-2008 F:\\PL21C.DDB - Documents\PL-21.SCH Title : Number : File : Revision: Sheet of Error : PTLOGO.WMF file not found. Zhongshan Deyuan Manufacturing Factory. SCH Drawn :Checked :Approved : 21W 1.0 Edition : Product Type : Revision Date :Issue Date : Handout To Department PR : RD : QC : PU : PE : GM : Page : C1 L1 C2 C8 C7 R5 C7 D3 D4 R6 C6 R9 TR1/a T2 R10 D10 D8 T1 R7 TR1/c TR1/b L2 L3 R8 N L C5 C 6 PTC FL1 D2 D1 F1 R 1 T3 D5 R2 R3 C9 D6 D9 D7 R4 RV1 L4 C3 C4 G This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only.

Test Report

Zhong Shan Heng Sheng Logistic Co., Ltd. FCC ID: WZA-TFSLRF FCC TEST REPORT Page 1 of 16 FCC ID : WZA-TFSLRF Applicant : Zhong Shan Heng Sheng Logistic Co., Ltd. Address : Luosan Industrial District, Fusha Town, Zhongshan, Guangdong, China Equipment Under Test (EUT) : Product description : Fluorescent fixtures Model No. : TF508, TF513, TF416, TF521, TF528 SL508, SL513, SL416, SL521, SL528 RF508, RF513, RF416, RF521,RF528 Standards : FCC Part18 Date of Test : Dec. 18, 2008 Test Engineer : Olic huang Reviewed By : PERPARED BY: Waltek Services (Shenzhen) Co., Ltd. 1/F, Fukangtai Building,West Baima Rd.,Songgang Street, Baoan District, Shenzhen 518105,China Tel: +86-755-27553488 Fax: +86-755-27553868 Zhong Shan Heng Sheng Logistic Co., Ltd.. FCC ID: WZA-TFSLRF Page 2 of 16 Contents Page 1 COVER PAGE..........................................................................................................................................................1 CONTENTS........................................................................................................................................................................2 2 TEST SUMMARY....................................................................................................................................................3 3 GENERAL INFORMATION..................................................................................................................................4 3.1 CLIENT INFORMATION............................................................................................................................................4 3.2 GENERAL DESCRIPTION OF E.U.T...........................................................................................................................4 3.3 DETAILS OF E.U.T. .................................................................................................................................................4 3.4 DESCRIPTION OF SUPPORT UNITS...........................................................................................................................4 3.5 STANDARDS APPLICABLE FOR TESTING..................................................................................................................4 3.6 TEST METHODOLOGY.............................................................................................................................................4 3.7 TEST FACILITY........................................................................................................................................................5 3.8 TEST LOCATION......................................................................................................................................................5 4 EQUIPMENT USED DURING TEST ...................................................................................................................6 5 CONDUCTED EMISSION TEST ..........................................................................................................................8 5.1 TEST EQUIPMENT....................................................................................................................................................8 5.2 TEST PROCEDURE...................................................................................................................................................8 5.3 CONDUCTED TEST SETUP.......................................................................................................................................9 5.4 EUT OPERATING CONDITION.................................................................................................................................9 5.5 CONDUCTED EMISSION LIMITS.............................................................................................................................10 5.6 SPECTRUM ANALYZER..........................................................................................................................................10 5.7 CONDUCTED EMISSION TEST RESULT...................................................................................................................10 5.7.1 Measurement Data .....................................................................................................................................10 6 PHOTOGRAPHS OF TESTING..........................................................................................................................17 6.1 CONDUCTED EMISSION TEST VIEW.......................................................................................................................17 7 PHOTOGRAPHS - CONSTRUCTIONAL DETAILS .......................................................................................18 7.1 EUT - FRONT VIEW..............................................................................................................................................18 7.2 EUT - BACK VIEW................................................................................................................................................18 7.3 PCB - FRONT VIEW..............................................................................................................................................19 7.4 PCB - BACK VIEW...............................................................................................................................................19 8 FCC ID LABEL ......................................................................................................................................................20 Zhong Shan Heng Sheng Logistic Co., Ltd.. FCC ID: WZA-TFSLRF Page 3 of 16 2 Test Summary Test Test RequirementTest Method Class / SeverityResult Radiated Emission (30MHz to 1GHz) FCC PART 18: 2007ANSI C63.4:2003 N/A N/A Conducted Emission (150KHz to 30MHz) FCC PART 18: 2007ANSI C63.4:2003 N/A PASS Zhong Shan Heng Sheng Logistic Co., Ltd.. FCC ID: WZA-TFSLRF Page 4 of 16 3 General Information 3.1 C…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted Emission Test View

Contact Information

Applicant

Bonnie Lin(Manager)
[email protected]+86-760-23400200Fax: +86-760-23400201

Test Firm

Waltek Services(Shenzhen) Co., Ltd.Philo zhong
[email protected]0086-755-27553488Fax: 0086-755-27553868

Technical Specifications

#Rule PartsFrequency RangePower Output
1180.045 MHz - 0.045 MHz-

Other Applications from Zhong Shan Heng Sheng Logistic Co., Ltd.

Portable Cabinet LED Luminaires - FCC ID WZA-FCLED-FCC - Zhong Shan Heng Sheng Logistic Co., Ltd.
WZA-FCLED-FCC

Portable Cabinet LED Luminaires

May 20, 2015

Equipment Class

8CC - Part 18 Consumer Device
Touch Dimmer - FCC ID WZA-FC-505-FCC - Zhong Shan Heng Sheng Logistic Co., Ltd.
WZA-FC-505-FCC

Touch Dimmer

Jun 12, 2012

Equipment Class

8CC - Part 18 Consumer Device