Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Mar 31, 2011
Application Purpose
Original Equipment
Date of Application
Mar 31, 2011
Equipment Note
LBS CDMA Mobile Unit
Frequency Range
824.70000000 - 848.31000000
Company
JOA TELECOM CO., LTD.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Parts List/Tune Up Info

↗

RF Exposure Info

↗
↗
↗
↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

GPS Device (Model : GPS-100MVPA) User Manual Revision 1.0 RM1007 Sicoxtower, 513-14, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea TEL: +82-31-777-9009 FAX: +82-31-719-1969 www.joatelecom.Co.kr GPS-100MVPA JOA Telecom Co., Ltd Proprietary and Confidential 2 Contents 1. Getting Started - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3 1-1. Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3 1-2. Appearance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -4 1-3. Charging Battery - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5 2. Using GPS-100MVPA- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -6 2-1. Basic Functions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -6 2-2. Button Functions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7 2-3. LCD Images - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9 3. Normal Care and Maintenance - - - - - - - - - - - - - - - - - - - - - - - - - 10 GPS-100MVPA JOA Telecom Co., Ltd Proprietary and Confidential 3 1. Getting Started 1-1. Specifications Model name GPS-100MVPA Technology CDMA : 800MHz 1x GPS : L1 (1575.42MHz) Antenna type Dual PIFA Intenna (CDMA + GPS) Operation temp. -20°C ~ +60°C Dimension 65mm x 33mm x 13.2mm (L x W x T) Weight 35g R-UIM Not-Support Battery Polymer 650mA Standby time 24 Hours GPS-100MVPA JOA Telecom Co., Ltd Proprietary and Confidential 4 1-2. Appearance Charging Adaptor LCD Speaker Emergency Button Power Button Mode Button Microphone Reset GPS-100MVPA JOA Telecom Co., Ltd Proprietary and Confidential 5 1-3. Charging Battery Use 24pin power adaptor included with the package. GPS-100MVPA JOA Telecom Co., Ltd Proprietary and Confidential 6 2. Using GPS-100MVP 2-1. Basic Functions  Real time position tracking  Managing route of GPS device  Using Google Map Service in user’s PC and Smart phone  Setting Safety-Zone (Geo Fence) Warning whenever one gets out of Safety-Zone or gets in.  Emergency (S.O.S) mode In an emergency, user can report the situation to protector by pressing Emergency (S.O.S) button.  Answering an incoming call  Making a call to the registered phone number GPS-100MVPA JOA Telecom Co., Ltd Proprietary and Confidential 7 2-2. Button Functions 2-2-1. Mode Button  Switch display In Idle screen, press the button to switch display DATE and TIME.  Answer a call Press the button to answer an incoming call.  Make a call In Idle screen, press the button longer to make a call to the registered phone number.  Wake up Sleep mode In Idle screen unless any button be used during seven (7) seconds, it turns into Sleep mode. To wake up Sleep mode, press the button (any button).  Volume control You can control the volume during a phone call. Press the button to control the volume. Default volume is level four (4) of level five (5). 2-2-2. Power Button  Wake up Sleep mode In Idle screen unless any button be used during seven (7) seconds, it turns into Sleep mode. To wake up Sleep mode, press the button (any button).  End a call Press the button to end a call.  Reject an incoming call Press the button to reject an incoming call. GPS-100MVPA JOA Telecom Co., Ltd Proprietary and Confidential 8  Power On/Off Press the button longer to power On/Off. 2-2-3. Emergency (S.O.S) Button  Wake up Sleep mode In Idle screen unless any button be used during seven (7) seconds, it turns into Sleep mode. To wake up Sleep mode, press the button (any button).  Emergency (S.O.S) mode In an emergency, user can report the situation to protector by pressing Emergency (S.O.S) button. To enter emergency (S.O.S) mode:  In Idle screen: Press the button longer.  In Sleep mode: Press the button longer.  During a phone call: Press the button shortly or longer. The call is over. Steps of Emergency (S.O.S) mode 1. In an emergency situation, GPS device user presses the Emergency (S.O.S) button. 2. GPS device sends SMS notice to protector automatically. 3. Protector calls to GPS device. 4. GPS device receives the protector’s call automatically and turns on microphone. Speaker turns out at the same time. 5. Protector can listen to sound of GPS device user’s situation. (After installing JOA Map Service in your PC, you can register phone number of protector.)  Release Emergency (S.O.S) mode In Emergency (S.O.S) mode, press Emergency (S.O.S) button longer to release emergency status. GPS-100MVPA JOA Telecom Co., Ltd Proprietary and Confidential 9 2-3. LCD Images Idle screen Phone number Emergency (S.O.S) mode Power On Power Off Fail to receive GPS signal Normal receiving GPS signal Needs battery charging Normal battery charging GPS-100MVPA JOA Telecom Co., Ltd Proprietary and Confidential 10 3. Normal Care and Maintenance  Do not drop the unit If violently impacted or shocked, serious damage may be caused.  Not water-resistant This device is not water-resistant. Keep it dry.  Keep away from strong magnetic fields When using or storing, please keep away from strong electromagnetic/ radioactive or magnetic field equipment.  Operating temperature The products operating temperature is between -20°C ~ +60°C; please do not operate under extreme temperatures.  Avoid exposure to sunlight Please avoid long periods of sunlight or high temperature exposure.  Do not disassemble Please do not disassemble the product, this may void the warranty and damage the unit.  Storage When the product is not being used for a long period, store the device in a cool and dry place. For long-term storage, keeping the unit in a dry box is recommended. Please do not keep the product in the following environments: 1. Unventilated and humid locations. 2. In a car window that is exposed to excessive amounts of sunlight. 3. In an environment where humidity is over 90%. GPS-100MVPA JOA Telecom Co., Ltd Proprietary and Confid…

Text truncated - open the document above for the full version.

Attestation Statements

CDMA 2000 1X LBS (GPS-150CP) Service Manual. - 33 - CONFIDENTIAL JOA Telecom 1. MAP - BOTTOM Chapter3. MAP / BOM CDMA 2000 1X LBS (GPS-150CP) Service Manual. - 34 - CONFIDENTIAL JOA Telecom - TOP

Attestation Statements

JOA TELECOM CO., LTD. 1007, SICOX Tower, 513-14, Sangdeawon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, 462-806, Korea Date: March 19, 2011 Compliance Certification Services Certification Division 47173 Benicia Street Fremont, CA 94538, USA To whom it may concern: I, the undersigned, hereby authorize Ms. Claire Hoque/Application Examiner of Compliance Engineering Services, Inc., d.b.a. Compliance Certification Services and hereafter referred to as CCS, to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Ms. Claire Hoque of CCS on our behalf shall have the same effect as acts of our own. In authorizing CCS as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards;

Attestation Statements

JOA TELECOM CO., LTD. 1007, SICOX Tower, 513-14, Sangdeawon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, 462-806, Korea Date: March 19, 2011 Compliance Certification Services Certification Division 47173 Benicia Street Fremont, CA 94538, USA LETTER OF AUTHORIZATION To whom it may concern: We, the undersigned, hereby authorize Harvey Sung of DIGITAL EMC Co., Ltd., to act on our behalf in all manners relating to application for equipment authorization for FCC ID: X25-GPS100MVPA including signing of all documents relating to these matters. Any and all acts carried out by DIGITAL EMC Co., Ltd., on our behalf shall have the same affect as acts of our own. This authorization is valid until further written notice from JOA TELECOM CO., LTD. Sincerely, HOON AHN Principal Research Engineer

Attestation Statements

JOA TELECOM CO., LTD. 1007, SICOX Tower, 513-14, Sangdeawon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, 462-806, Korea Date: March 19, 2011 Compliance Certification Services Certification Division 47173 Benicia Street Fremont, CA 94538, USA RE: Request of Confidentiality for FCCID: X25-GPS100MVPA To Whom It may Concern: Pursuant to Sections 0.457 and 0.459 of the Commission`s Rules(CFR 47), and Section 552 (b) (4) of the Freedom of Information Act, JOA TELECOM CO., LTD. hereby requests confidentiality and treatment of certain information accompanying this application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also hereby request Short-Term Confidentiality for 180 days after the grant as outlined in Public Notice DA 04-1705. This provision will give JOA TELECOM CO., LTD. temporary confidentiality of commercially sensitive information prior to product release. The requested permanent and Short-Term Confidential exhibits are listed as follows: PERMANENT & SHORT-TERM CONFIDENTIAL LIST Exhibit Description File name PERMANENT 1 Block Diagram Block Diagram_X25-GPS100MVPA.pdf 2 Operational Description Operational Description_X25-GPS100MVPA.pdf 3 Schematics Schematic_X25-GPS100MVPA.pdf 4 Part Lists Part List_X25-GPS100MVPA.pdf SHORT-TERM 5 External Photos Ext Photo_X25-GPS100MVPA.pdf 6 Internal Photos Int Photo_X25-GPS100MVPA.pdf 7 Test-Setup Photos Test Photo_X25-GPS100MVPA.pdf 8 Users Manual User Manual_X25-GPS100MVPA.pdf Note: The pictures on the label location do not require any long term or short term confidentiality. The Applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentations, where applicable, will not be public before the date of the Grant for this application. Sincerely, HOON AHN Principal Research Engineer

External Photos

FCCID: X25-GPS100MVPA Copyright Ⓒ 2011, DIGITAL EMC Co., Ltd. View 1 FCCID: X25-GPS100MVPA Copyright Ⓒ 2011, DIGITAL EMC Co., Ltd. View 2 FCCID: X25-GPS100MVPA Copyright Ⓒ 2011, DIGITAL EMC Co., Ltd. View 3

ID Label/Location Info

FCC ID: X25-GPS100MVPA Copyright Ⓒ 2011, DIGITAL EMC Co., Ltd. FCC ID SAMPLE LABEL & LOCATION LABELLING REQUIREMENTS PER §2.925 The Label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time of purchase FCCID: X25-GPS100MVPA M/N: GPS100MVPA S/N: Manufacturer: JOA TELECOM CO., LTD.

Internal Photos

FCCID: X25-GPS100MVPA Copyright Ⓒ 2011, DIGITAL EMC Co., Ltd. View 1 FCCID: X25-GPS100MVPA Copyright Ⓒ 2011, DIGITAL EMC Co., Ltd. View 2 FCCID: X25-GPS100MVPA Copyright Ⓒ 2011, DIGITAL EMC Co., Ltd. View 3 FCCID: X25-GPS100MVPA Copyright Ⓒ 2011, DIGITAL EMC Co., Ltd. View 4 FCCID: X25-GPS100MVPA Copyright Ⓒ 2011, DIGITAL EMC Co., Ltd. View 5 FCCID: X25-GPS100MVPA Copyright Ⓒ 2011, DIGITAL EMC Co., Ltd. View 6 FCCID: X25-GPS100MVPA Copyright Ⓒ 2011, DIGITAL EMC Co., Ltd. View 7 FCCID: X25-GPS100MVPA Copyright Ⓒ 2011, DIGITAL EMC Co., Ltd. View 8 - CDMA Antenna

Parts List/Tune Up Info

Applicant : JOA TELECOM CO., LTD. FCC ID: X25-GPS100MVPA TUNE-UP PROCEDURE There are no user accessible adjustments or tuning in this GPS Device All necessary adjustments and tuning are performed during manufacture of the product. Any adjustments or tuning after service or repair are done as part of that process as special equipment is required to perform such adjustments.

RF Exposure Info

1101-00119 DRTFCC1103-0083 TRF-RF-303(03)100616 Page2 / 24 Copyright ○ C 2011 Digital EMC Co., Ltd. CONTENTS 1. DESCRIPTION OF DEVICE .......................................................................................................... 3 2. INTROCUCTION ........................................................................................................................... 4 3. DESCRIPTION OF TEST EQUIPMENT ....................................................................................... 6 3.1 SAR MEASUREMENT SETUP .............................................................................................. 6 3.2 Probe Measurement System .................................................................................................. 7 3.3 Probe Calibration Process ..................................................................................................... 8 3.4 SAM PHANTOM ................................................................................................................... 10 3.5 Device Holder for Transmitters ............................................................................................. 10 3.6 Brain & Muscle Simulating Mixture Characterization ........................................................... 11 4. SAR MEASUREMENT PROCEDURE ........................................................................................ 12 5. DEFINITION OF REFERENCE POINTS .................................................................................... 13 5.1 TEST CONFIGURATION POSITIONS ................................................................................ 14 6. ANSI / IEEE C95.1-2005 RF EXPOSURE LIMITS ..................................................................... 16 7. IEEE P1528 –MEASUREMENT UNCERTAINTIES .................................................................... 17 8. SYSTEM VERIFICATION ............................................................................................................ 18 9. FCC 3G SAR MEASUREMENT PROCEDURES – OCT. 2007 .................................................. 19 10. SAR TEST DATA SUMMARY AND POWER TABLE ............................................................... 20 10.1 See Measurement Result Data Pages ............................................................................... 20 11. SAR TEST DATA SUMMARY ................................................................................................... 21 11.1 Measurement Results (CDMA Cellular Body SAR) ............................................................ 21 12. SAR TEST EQUOPMENT ......................................................................................................... 22 13. CONCLUSION ........................................................................................................................... 23 14. REFERENCES .......................................................................................................................... 24 1101-00119 DRTFCC1103-0083 TRF-RF-303(03)100616 Page3 / 24 Copyright ○ C 2011 Digital EMC Co., Ltd. 1. DESCRIPTION OF DEVICE Environmental evaluation measurements of specific absorption rate (SAR) distributions in emulated human head and body tissues exposed to radio frequency (RF) radiation from wireless portable devices for compliance with the rules and regulations of the U.S. Federal Communications Commission (FCC). General Information Equipment type GPS Device FCC ID: X25-GPS100MVPA Equipment model name GPS100MVPA Equipment add model name GPS-150CP Equipment serial no. Identical prototype Mode(s) of Operation CDMA Cellular TX Frequency Range 824.70 ~ 848.31 MHz(CDMA Cellular) RX Frequency Range 869.70 ~ 893.31 MHz(CDMA Cellular) Max. SAR Measurement 1.020 mW/g CDMA Cellular Body SAR FCC Equipment Class Licensed Non-Broadcast Station Transmitter(TNB) Date(s) of Tests 2011-03-02 Antenna Type Internal antenna 1101- TRF-R 2. I N The F 93-62 porta b publis C95.1 kHz t o measu Hazar expos the Na Radio the ra levels SAR Speci f (dissip the ra SAR i W NOT E relatio polarit a grou 00119 RF-303(03)1 NTROCU FCC has ado on Aug. 6, 1 ble devices. shed by the A -2005 Stand o 300 GHz. urement proc rdous Electro sure from the ational Coun o frequency E ate of energy for potential Definition fic Absorptio pated in) an te of RF en e s expressed Where: = cond u = mass E = Total E: The prim ons to the di ty of field vec und plane. 00616 CTION opted the gu 1996 to prote The safety American Na dard for Safe 1992 by the cedure desc omagnetic F e Equipment ncil on Radia Electromagne y absorption l biological h n on Rate (SA incremental ergy absorpti in units of W uctivity of the density of th RMS electric mary factors t imensions a ctors, the pre C idelines for e ect the public limits used ational Stand ety Levels w e Institute of cribed in IEEE ields - RF a Under Test ation Protect etic Fields,” due to exp o azards. AR) is define mass (dm) on per unit m Watts per Kilo e tissue - sim he tissue-sim c field streng hat control ra nd geometry esence of re Figur opyright ○ C evaluating th c and worker d for the en dards Institut ith Respect t f Electrical a E/ANSI C95. nd Microwav (EUT). Thes tion and Mea NCRP Repo osure to an R ed as the ti contained in mass at a po ogram (W/kg mulating mate mulating mate gth (V/m) ate of energy y of the irrad flecting surfa re 2.1 SAR 2011 Digital he environm rs from the p vironmental te (ANSI) for to Human E and Electron .3-1992 Reco ve is used fo se criteria for asurements ort No. 86 NC RF transmitti ime derivativ n a volume e int in an abs g). erial (S/m) erial (kg/m3) y absorption diated organ aces, and wh R Mathema EMC Co., L ental effects otential haza evaluation r localized sp xposure to R nics Enginee ommended P or guidance r SAR evalua (NCRP) in B CRP, 1986, B ng source. S ve (rate) of element (dV) orbing body were found nism, the ori hether condu atical Equ Ltd. s of radio fre ards of RF em measureme pecific absor Radio Freque …

Text truncated - open the document above for the full version.

RF Exposure Info

DIGITAL EMC CO., LTD DUT: Dipole 835 MHz; Type: D835V2; Serial: D835V2 - SN:464 Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1 Medium parameters used: f = 835 MHz; σ = 0.957 mho/m; ε r = 54.7; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY4 Configuration: Probe: EX3DV4 - SN3643; ConvF(8.97, 8.97, 8.97); Calibrated: 2011-01-24; Electronics: DAE3 Sn519 Phantom: SAM with 835MHz; Type: SAM; Serial: TP-1223 Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186 Test Date: 2011-03-02; Ambient Temp: 22.3; Tissue Temp: 22.6 Dipole Validation Area Scan (61x81x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Power Drift = -0.064 dB Peak SAR (extrapolated) = 3.79 W/kg SAR(1 g) = 2.52 mW/g; SAR(10 g) = 1.67 mW/g 0 dB = 3.09mW/g DIGITAL EMC CO., LTD DUT: GPS100MVPA; Type: Dongle Communication System: FCC CDMA; Frequency: 836.52 MHz;Duty Cycle: 1:1 Medium parameters used: f = 836.52 MHz; σ = 0.967 mho/m; ε r = 54.9; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY4 Configuration: Probe: EX3DV4 - SN3643; ConvF(8.97, 8.97, 8.97); Calibrated: 2011-01-24; Electronics: DAE3 Sn519 Phantom: SAM with 835MHz; Type: SAM; Serial: TP-1223 Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186 Test Date: 2011-03-02; Ambient Temp: 22.3; Tissue Temp: 22.6 1cm space from Body, Top, CDMA Cellular Ch. 384, Ant Internal Area Scan (61x61x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Power Drift = -0.072 dB Peak SAR (extrapolated) = 0.299 W/kg SAR(1 g) = 0.150 mW/g; SAR(10 g) = 0.086 mW/g 0 dB = 0.210mW/g DIGITAL EMC CO., LTD DUT: GPS100MVPA; Type: Dongle Communication System: FCC CDMA; Frequency: 836.52 MHz;Duty Cycle: 1:1 Medium parameters used: f = 836.52 MHz; σ = 0.967 mho/m; ε r = 54.9; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY4 Configuration: Probe: EX3DV4 - SN3643; ConvF(8.97, 8.97, 8.97); Calibrated: 2011-01-24; Electronics: DAE3 Sn519 Phantom: SAM with 835MHz; Type: SAM; Serial: TP-1223 Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186 Test Date: 2011-03-02; Ambient Temp: 22.3; Tissue Temp: 22.6 1cm space from Body, Bottom, CDMA Cellular Ch. 384, Ant Internal Area Scan (81x71x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Power Drift = -0.003 dB Peak SAR (extrapolated) = 0.048 W/kg SAR(1 g) = 0.030 mW/g; SAR(10 g) = 0.021 mW/g 0 dB = 0.038mW/g DIGITAL EMC CO., LTD DUT: GPS100MVPA; Type: Dongle Communication System: FCC CDMA; Frequency: 836.52 MHz;Duty Cycle: 1:1 Medium parameters used: f = 836.52 MHz; σ = 0.967 mho/m; ε r = 54.9; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY4 Configuration: Probe: EX3DV4 - SN3643; ConvF(8.97, 8.97, 8.97); Calibrated: 2011-01-24; Electronics: DAE3 Sn519 Phantom: SAM with 835MHz; Type: SAM; Serial: TP-1223 Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186 Test Date: 2011-03-02; Ambient Temp: 22.3; Tissue Temp: 22.6 1cm space from Body, Bottom, CDMA Cellular Ch. 384, Ant Internal Area Scan (81x71x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 1: Measurement grid: dx=8mm, dy=8mm, dz=5mm Power Drift = -0.003 dB Peak SAR (extrapolated) = 0.042 W/kg SAR(1 g) = 0.027 mW/g; SAR(10 g) = 0.021 mW/g 0 dB = 0.033mW/g DIGITAL EMC CO., LTD DUT: GPS100MVPA; Type: Dongle Communication System: FCC CDMA; Frequency: 824.7 MHz;Duty Cycle: 1:1 Medium parameters used: f = 824.7 MHz; σ = 0.942 mho/m; ε r = 54.5; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY4 Configuration: Probe: EX3DV4 - SN3643; ConvF(8.97, 8.97, 8.97); Calibrated: 2011-01-24; Electronics: DAE3 Sn519 Phantom: SAM with 835MHz; Type: SAM; Serial: TP-1223 Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186 Test Date: 2011-03-02; Ambient Temp: 22.3; Tissue Temp: 22.6 1cm space from Body, Horizontal Up, CDMA Cellular Ch. 1013, Ant Internal Area Scan (61x81x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Power Drift = -0.229 dB Peak SAR (extrapolated) = 1.76 W/kg SAR(1 g) = 1.02 mW/g; SAR(10 g) = 0.607 mW/g 0 dB = 1.32mW/g DIGITAL EMC CO., LTD DUT: GPS100MVPA; Type: Dongle Communication System: FCC CDMA; Frequency: 836.52 MHz;Duty Cycle: 1:1 Medium parameters used: f = 836.52 MHz; σ = 0.967 mho/m; ε r = 54.9; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY4 Configuration: Probe: EX3DV4 - SN3643; ConvF(8.97, 8.97, 8.97); Calibrated: 2011-01-24; Electronics: DAE3 Sn519 Phantom: SAM with 835MHz; Type: SAM; Serial: TP-1223 Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186 Test Date: 2011-03-02; Ambient Temp: 22.3; Tissue Temp: 22.6 1cm space from Body, Horizontal Up, CDMA Cellular Ch. 384, Ant Internal Area Scan (61x81x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Power Drift = 0.377 dB Peak SAR (extrapolated) = 1.76 W/kg SAR(1 g) = 1.01 mW/g; SAR(10 g) = 0.601 mW/g 0 dB = 1.29mW/g DIGITAL EMC CO., LTD DUT: GPS100MVPA; Type: Dongle Communication System: FCC CDMA; Frequency: 848.31 MHz;Duty Cycle: 1:1 Medium parameters used: f = 848.31 MHz; σ = 0.985 mho/m; ε r = 54.9; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY4 Configuration: Probe: EX3DV4 - SN3643; ConvF(8.97, 8.97, 8.97); Calibrated: 2011-01-24; Electronics: DAE3 Sn519 Phantom: SAM with 835MHz; Type: SAM; Serial: TP-1223 Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186 Test Date: 2011-03-02; Ambient Temp: 22.3; Tissue Temp: 22.6 1cm space from Body, Horizontal Up, CDMA Cellular Ch. 777, Ant Internal Area Scan (61x81x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Power Drift = 0.091 dB Peak SAR (extrapolated) = 1.78 W/kg SAR(1 g) = 1.02 mW/g; SAR(10 g) = 0.595 mW/g 0 dB = 1.33mW/g DIGITAL …

Text truncated - open the document above for the full version.

Test Report

1101-00119 DRTFCC1103-0085 TRF-RF-209(01)110318 Page 2 / 23 Copyright ○ C 2011, Digital EMC Co., Ltd. CONTENTS 1. Equipment information .............................................................. 3 1.1 Equipment description ........................................................................... 3 1.2 Ancillary equipment ............................................................................... 3 2. Information about test items ..................................................... 4 2.1 Test mode ................................................................................................ 4 2.2 Auxiliary equipment ............................................................................... 4 2.3 Tested environment ................................................................................ 4 2.4 EMI Suppression Device(s)/Modifications ........................................... 4 3. Description of tests ................................................................... 5 3.1 Effective radiated power & equivalent isotropic radiated power ....... 5 3.2 Occupied bandwidth .............................................................................. 5 3.3 Spurious and harmonic emissions at antenna terminal ..................... 5 3.4 Radiation spurious and harmonic emissions ...................................... 6 3.6 Frequency stability/temperature variation. .......................................... 6 4. Test rport .................................................................................... 7 4.1 Summary of tests ................................................................................... 7 4.2 Test data .................................................................................................. 8 4.2.1 Conducted output power .................................................................................. 8 4.2.2 Occupied bandwidth(99%) ............................................................................... 9 4.2.3 Spurious and harmonic emissions at antenna terminal ................................. 12 4.2.4 Band edge ..................................................................................................... 15 4.2.5 Effective Radiated Power(CDMA850) ........................................................... 16 4.2.6 Radiated spurious emissions(CDMA850) ...................................................... 17 4.2.7 Frequency Stability(CDMA850) ..................................................................... 18 4.2.8 SAMPLE CALCULATIONS ............................................................................ 19 APPENDIX..................................................................................... 20 1101-00119 DRTFCC1103-0085 TRF-RF-209(01)110318 Page 3 / 23 Copyright ○ C 2011, Digital EMC Co., Ltd. 1. Equipment information 1.1 Equipment description FCC Equipment Class Licensed Non-Broadcast Station Transmitter(TNB) Equipment type GPS Device Equipment model name GPS100MVPA Equipment add model name GPS-150CP Equipment serial no. Identical prototype Tx Freq. Range 824.70 ~ 848.31 MHz Rx Freq. Range 869.70 ~ 893.31 MHz Max. Power Rating 0.329W ERP(25.17dBm) Emission Designators 1M27F9W Power Battery: DC 3.7V 1.2 Ancillary equipment Equipment Model No. Serial No. Manufacturer Note - - - - - - - - - - 1101-00119 DRTFCC1103-0085 TRF-RF-209(01)110318 Page 4 / 23 Copyright ○ C 2011, Digital EMC Co., Ltd. 2. Information about test items 2.1 Test mode This Device was tested in continuous transmitting mode.(at maximum power) Test Case 1 Only EUT Test Case 2 - 2.2 Auxiliary equipment Equipment Model No. Serial No. Manufacturer Note - - 2.3 Tested environment Temperature : 23 ~ 24 o C Relative humidity content : 28 ~ 32 % R.H. Details of power supply :DC 3.7 V 2.4 EMI Suppression Device(s)/Modifications EMI suppression device(s) added and/or modifications made during testing → None 1101-00119 DRTFCC1103-0085 TRF-RF-209(01)110318 Page 5 / 23 Copyright ○ C 2011, Digital EMC Co., Ltd. 3. Description of tests 3.1 Effective radiated power & equivalent isotropic radiated power These measurements were performed outdoors at 3meter test range. The equipment under test is placed on a wooden turntable 0.8-meters above the ground plane and 3-meters from the receive antenna. The receive antenna height and turntable rotations were adjusted for the highest reading on the receive spectrum analyzer. A half-wave dipole was substituted in place of the EUT. This dipole antenna was driven by a signal generator and the level of the signal generator was adjusted to obtain the same receive spectrum analyzer reading. For readings above 1GHz, the above procedure is repeated using horn antennas and the difference between the gain of the horn and an isotropic antenna are taken into consideration. 3.2 Occupied bandwidth The EUT was setup to maximum output power at its lowest channel. The occupied bandwidth was measured using a spectrum analyzer. The measurements are repeated for the highest and a middle channel. The EUT’s occupied bandwidth is measured as the width of the signal between two points, one below the carrier center frequency and one above the carrier frequency, outside of which all emissions are attenuated at least 26 dB below the transmitter power. Plots of the EUT’s occupied bandwidth are shown herein. 3.3 Spurious and harmonic emissions at antenna terminal The level of the carrier and the various conducted spurious and harmonic frequencies is measured by means of a calibrated spectrum analyzer. The EUT was setup to maximum output power at its lowest channel. The spectrum is scanned…

Text truncated - open the document above for the full version.

Contact Information

Applicant

HOON AHN(Principal Research Engineer)
[email protected]82-31-777-9009Fax: 82-31-719-1969

Test Firm

DT&C Co.,Changho Lee
[email protected]82-31-321-2664Fax: 82-31-321-1664

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
122H824.7 MHz - 848.31 MHz329.00 mW1M27F9W2.5000000000 ppm
Confidentiality
Long Term
Grant Notes
Power output listed is ERP. SAR compliance for body-worn operations is restricted to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 10 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported Body SAR is 1.02 W/kg.

Other Applications from JOA TELECOM CO., LTD.

CDMA GPS USB Dongle - FCC ID X25-GPS100MVP - JOA TELECOM CO., LTD.
X25-GPS100MVP

CDMA GPS USB Dongle

Mar 31, 2011

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
CDMA GPS Mobile Terminal - FCC ID X25-GPS200MV - JOA TELECOM CO., LTD.
X25-GPS200MV

CDMA GPS Mobile Terminal

Mar 31, 2011

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
LBS CDMA Mobile Unit - FCC ID X25-GPS150MV - JOA TELECOM CO., LTD.
X25-GPS150MV

LBS CDMA Mobile Unit

Jan 18, 2010

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter