FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. GN Hearing A/S/
  3. X26SM-3P

X26SM-3PAccesory to wireless hearing instrument

GN Hearing A/S

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 12, 2024
Application Purpose
Original Equipment
Date of Application
Aug 12, 2024
Equipment Note
Accesory to wireless hearing instrument
Frequency Range
2402.00000000 - 2480.00000000
Company
GN Hearing A/S
Country
Denmark

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

FCB046_02 //DEKRA Testing and Certification, S.A.U. // www.dekra-product-safety.com/wireless Date: 08/08/2024 DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂ­a C/ Severo Ochoa 2 & 6 29590 Campanillas Málaga, España Certification designating a U.S. agent for service of process. As required by section 2.911(d)(7), FCC ID: X26SM-3P We, GN Hearing A/S Lautrupbjerg 7, Ballerup, DK-2750, Denmark FRN: 0019433481 certify that: GN Hearing Care Corporation 8001 Bloomington Freeway, Bloomington, MN 55420, United States FRN: 0026838490 Thomas Brockway [email protected] Is our designated U.S. agent for service of process and we acknowledge: - our consent to accept service of process in the United States for matters related to the applicable equipment at the physical U.S. address and email address of the designated U.S. agent - the acceptance to maintain an U.S. agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Designated U.S. Agent Sincerely, ________________ By: Nichlas Brown Holm Title: Regulatory Certification Manager Company: GN HEARING A/S Telephone: +45 4575 0000 e-mail: [email protected] We acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address stated above. __________________ By: Thomas Brockway Title: Senior QA Engineer Company: GN Hearing Care Corporation Telephone: +1 9527698048 e-mail: [email protected] Docusign Envelope ID: 2329A318-C265-4D66-84E8-5AF93AA8C1F2

ID Label/Location Info

123 123 A B C A B C This document may not be reproduced or distributed in any way without the consent of GN Hearing A/S. Template: A3_LANDSCAPE_ASM-PAINT GN Hearing A/S Drw. Rev.Description Date Updated by (dd.mm.yyyy) 03 - Changed the size of Malaysia logo. - Moved CE mark Before 1.83 from Datum C to 2.13 from Datum C. - Added: CMIIT ID, IC, FCC ID 14.05.2024leajoe A Released for production 06.06.2024 leajoe B Japan symbol and Made in China added. Released for production 19.07.2024 leajoe 2187710 -- COV BK,SM-3P,PTD Drawing Number:Drawing Name: 3 B. 19-Jul-24Design Date: 1 of 1 Sheet: Unit: mm leajoe Designed by: 2:1 Scale: Drw Rev: CPH Design site: A3 DRW size:Projection: Notes: 1. Text shown on drawing is "outline", but should be "filled" during marking. 2. Technology: Tampo printed, unless otherwise specified. 3. General tolerances on dimensions are #0.20 mm unless otherwise specified. 4. Cosmetic specifications are defined in GN ReSound documents 0007510 (Corporate cosmetic insp. proc.) 5. Color of print: White. See BOM for specifications. 6. The following dimensions have been deleted from the drawing: None 7. Measurement planes for the part are defined by the Datum reference frame: A B C SCALE 1:1 SECTION A-A 1 2 3 B1 B2 A1 A2 A3 C B A 3,50 ( ) 17,15 ( )0,13 ()10,39 ( ) 6,07 1,78 2,00

RF Exposure Info

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: 71730RAN.002A1 2024-08-08 Test report No: NIE: 71730RAN.002A1 Assessment report RF EXPOSURE REPORT ACCORDING TO FCC 47 CFR Part 2.1093 FCC 47 CFR Part 1.1307 (*) Identification of item under evaluation Multi-mic (*) Trademark GN Hearing (*) Model and /or type reference SM-3P (*) Other identification of the product HW version: Multi-mic B5 SW Version : Farlander5 FCC ID: X26SM-3P IC: 6941C-SM3P (*) Features Bluetooth (*) Manufacturer GN Hearing A/S Lautrupbjerg 7, 2750 Ballerup, Denmark Test method requested, standard FCC 47 CFR Part 2.1093. Radiofrequency radiation exposure evaluation: portable devices. FCC 47 CFR Part 1.1307: Actions that may have a significant environmental effect, for which Environmental Assessments (EAs) must be prepared. Summary IN COMPLIANCE Approved by (name / position & signature) Manuel García Antennas Lab Technical Responsible Date of issue 2024-08-08 Report template No FAN24_02 (*) “Data provided by the client” DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: 71730RAN.002A1 Page 2 of 10 2024-08-08 Index Competences and guarantees .................................................................................................... 3 General conditions ...................................................................................................................... 3 Data provided by the client .......................................................................................................... 3 Identification of the client............................................................................................................. 4 Document history ........................................................................................................................ 4 Appendix A: FCC RF Exposure assessment result ..................................................................... 5 General description of the device under evaluation ................................................................ 6 Evaluation Results .................................................................................................................. 7 Appendix B: FCC RF Exposure information ................................................................................ 8 RF Exposure determination of exemption ............................................................................... 9 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Report No: 71730RAN.002A1 Page 3 of 10 2024-08-08 Competences and guarantees In order to assure the traceability to other national and international laboratories, DEKRA Testing and Certification, S.A.U. has a calibration and maintenance program for its measurement equipment. DEKRA Testing and Certification, S.A.U. guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated on the report and, it is based on the knowledge and technical facilities available at DEKRA Testing and Certification, S.A.U. at the time of performance of the test. DEKRA Testing and Certification, S.A.U. is liable to the client for the maintenance of the confidentiality of all information related to the item under test and the results of the test. The results presented in this Assessment Report apply only to the particular item under test established in this document. IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means, except in full, without the previous written permission of DEKRA Testing and Certification, S.A.U. General conditions 1. This report is only referred to the item that has undergone the assessment. 2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without previous written permission of DEKRA Testing and Certification, S.A.U. 4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written permission of DEKRA Testing and Certification, S.A.U. and the Accreditation Bodies Data provided by the client The following data has been provided by the client: 1. Information relating to the description of the sample ("Identification of the item under evaluation", "Trademark", "Model and/or type reference", “General description of the device”, “Other identification of the product”). 2. Maximum output power, maximum antenna gain and use distance information 3. The device under evaluation consists of a based multi-mic’s main functionality is to stream enhanced audio content from a listening scenario to the hearing instruments of the hearing-impaired listener. The enhancement comes by improving the signal-to-noise ratio (SNR), i.e. the ratio between the speech or sound signal of interest and disturbing surrounding noise sources, for the listener during challenging listening situations, e.g. in a restaurant, during family dinners, during meetings, but also during presentations/lectures or in classroom situations. The multi-mic has four main functionalities: (1) Clipped on to the intended speaker/conversation-partner of interest it shall pick up a clean signal of their voice (spouse, colleague, teacher, etc), (2) Lying on the table, it shall pick up voices of speakers around the table. (3) Suppressing unwanted noises from surroundings (e.g. cutlery handling, background noise, wind, etc.) (4) Connecting to external sound sources such as mp3 players (or similar media) or Telecoil (TC) systems.…

Text truncated - open the document above for the full version.

Test Report

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 71730RRF.002 2024-07-22 ISED CABid: ES1909 Lab. Company Number: 4621A Test Report No: 71730RRF.002 Test Report USA FCC Part 15.247, 15.209 CANADA RSS-247, RSS-Gen (*) Identification of item tested Multi-mic (*) Trademark GN Hearing (*) Model and /or type reference SM-3P (*) Other identification of the product HW version: Multi-mic B5 SW version: Farlander5 FCC ID: X26SM-3P IC: 6941C-SM3P (*) Features Bluetooth LE Applicant GN Hearing A/S Lautrupbjerg 7, 2750 Ballerup, Denmark Test method requested, standard USA FCC Part 15.247 (10-1-23 Edition): Operation within the bands 902 - 928 MHz, 2400 -2483.5 MHz, and 5725 - 5850 MHz. USA FCC Part 15.209 (10-1-23 Edition): Radiated emission limits; general requirements. CANADA RSS-247 Issue 3 (August 2023). CANADA RSS-Gen Issue 5 amendment 2 (February 2021). Guidance for Performing Compliance Measurements on Digital Transmission System, Frequency Hopping Spread Spectrum System, and Hybrid Systems Devices Operating Under Section 15.247 of the FCC Rules. 558074 D01 Meas Guidance v05r02 dated April 2, 2019. ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices. Summary IN COMPLIANCE Approved by (name / position & signature) José Manuel Gómez Galván EMC Consumer & RF Lab. Manager Date of issue 2024-07-22 Report template No FDT08_25 (*) “Data provided by the client” DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 71730RRF.002 Page 2 of 84 2024-07-22 Index INDEX ........................................................................................................................................................................... 2 ACRONYMS ................................................................................................................................................................. 3 COMPETENCES AND GUARANTEES ....................................................................................................................... 3 GENERAL CONDITIONS ............................................................................................................................................. 4 UNCERTAINTY ............................................................................................................................................................ 4 DATA PROVIDED BY THE CLIENT ............................................................................................................................ 4 USAGE OF SAMPLES ................................................................................................................................................. 5 TEST SAMPLE DESCRIPTION ................................................................................................................................... 6 IDENTIFICATION OF THE CLIENT ............................................................................................................................. 7 TESTING PERIOD AND PLACE .................................................................................................................................. 7 DOCUMENT HISTORY ................................................................................................................................................ 7 ENVIRONMENTAL CONDITIONS ............................................................................................................................... 7 REMARKS AND COMMENTS ..................................................................................................................................... 8 TESTING VERDICTS ................................................................................................................................................... 9 SUMMARY .................................................................................................................................................................... 9 APPENDIX A: TEST RESULTS. BLUETOOTH LOW ENERGY 5.0 (2M, 1M) ......................................................... 10 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456 Report No: 71730RRF.002 Page 3 of 84 2024-07-22 Acronyms Acronym ID Acronym Description BW Bandwidth Detector Detector used Ebw Emission Bandwidth Equipment Equipment Type Freq Frequency Freq Rng Frequency Range Inband Peak Lvl Inband Peak Level Lvl Level MP Measurement Point Mod Modulation Mode MIMO Mode Occ Ch BW Occupied Channel Bandwidth PSD Power Spectral Density Peak Power Maximum Peak Conducted Output Power Pol Polarization Port Active Port Unwanted Freq Unwanted Emissions Frequency Unwanted Lvl Unwanted Emissions Level Competences and guarantees DEKRA Testing and Certification S.A.U. is a testing laboratory accredited by the National Accreditation Body (ENAC -Entidad Nacional de Acreditación), to perform the tests indicated in the Certificate No. 51/LE 147. DEKRA Testing and Certification S.A.U. is an FCC-recognized accredited testing laboratory with appropriate scope of accreditation that covers the performed tests in this report. DEKRA Testing and Certification S.A.U. is an ISED-recognized accredited testing laboratory, CABid: ES1909, Company Number: 4621A, with the appropriate scope of accreditation that covers the performed tests in this report. In order to assure the traceability to other national and international laboratories, DEKRA Testing and Certification S.A.U. has a calibration and maintenance program for its measurement equipment. DEKRA Testing and Certification S.A.U. guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test o…

Text truncated - open the document above for the full version.

Test Report

SM-3P Antenna Diagram Manufacturer: GN Hearing A/S Device Type : SM-3P # 21925600 Antenna type: Patch antenna Max. antenna gain: 3 dBi Frequency range 2402 – 2480 MHz Antenna construction: Integral antenna Antenna Diagram Max EIRP 8.75 dBm [180.0, 0.0] f [MHz] Max EIRP (dBm) Max EIRP Angle (Theta, Phi) 2402 6.73 [45.0, 30.0] 2440 8.75 [180.0, 0.0] 2480 8.00 [45.0, 90.0] Considering that the measured input power to the Antenna is 5.75 dBm and the maximum measured EIRP is 8.75 dBm at 2440 MHz, then, the maximum antenna gain is 3 dBi.

Contact Information

Applicant

Nichlas Brown Holm
[email protected]+4523421388Fax: +4572111889

Test Firm

DEKRA Testing and Certification, S.A.U.Rafael Lopez Martin
[email protected]34-9562-61 91 00Fax: 34-9562-61 91 13

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.40 GHz - 2.48 GHz2.58 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This device meets the SAR Test Exclusion threshold specified in KDB447498 and since then, it is authorized for portable operation

Other Applications from GN Hearing A/S

Accesory to wireless hearing instrument - FCC ID X26SAS-4 - GN Hearing A/S
X26SAS-4

Accesory to wireless hearing instrument

Aug 24, 2023

Equipment Class

DTS - Digital Transmission System
Rechargeable wireless hearing instrument - FCC ID X26DURR1 - GN Hearing A/S
X26DURR1

Rechargeable wireless hearing instrument

Jul 10, 2023

Equipment Class

DTS - Digital Transmission System
Wireless hearing instrument - FCC ID X26CABR70 - GN Hearing A/S
X26CABR70

Wireless hearing instrument

Feb 21, 2022

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
X26WOE46R

Wireless hearing instrument

Jul 29, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless hearing instrument - FCC ID X26WOE46L - GN Hearing A/S
X26WOE46L

Wireless hearing instrument

Jul 29, 2021

Equipment Class

DTS - Digital Transmission System