FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. BASE4 Group, Inc./
  3. X4E01095T

X4E01095TREMOTE DIGITAL MEAT THERMOMETER

BASE4 Group, Inc.
REMOTE DIGITAL MEAT THERMOMETER - FCC ID X4E01095T - BASE4 Group, Inc.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
May 05, 2010
Application Purpose
Original Equipment
Date of Application
May 05, 2010
Equipment Note
REMOTE DIGITAL MEAT THERMOMETER
Frequency Range
433.92000000 - 433.92000000
Company
BASE4 Group, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

โ†—

Block Diagram

โ†—

Cover Letter(s)

โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

Operational Description

โ†—

Schematics

โ†—

Test Report

โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Block Diagram

Block Diagram(Transmitter) MCU OSC 32768Hz SWITCH TEMPERATURE SENSOR RF BOARD 433.92MHz crystal oscillator 433.92MHz LCD DATA KEY

External Photos

Report No.: TB-F106202 EXHIBIT 2 - EUT EXTERNAL PHOTOGRAPHS Shenzhen Toby Technology Co., Ltd. FCC ID : X4E01095T Page 2 of 7 Photo 1 Appearance of EUT Photo 2 Appearance of EUT

ID Label/Location Info

Report No.: TB-F106202 EXHIBIT 1- EUT TESTING PHOTOGRAPHS Shenzhen Toby Technology Co., Ltd. FCC ID : X4E01095T Page 1 of 7 FCC ID Label Sample FCC ID: X4E01095T Specifications: Text is Black in color and justified. Labels are printed in indelible ink on permanent adhesive silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. FCC ID Label Location on EUT FCC ID LOCATION

Internal Photos

Report No.: TB-F106202 EXHIBIT 2 - EUT EXTERNAL PHOTOGRAPHS Shenzhen Toby Technology Co., Ltd. FCC ID : X4E01095T Page 3 of 7 Photo 3 Inside of EUT Photo 4 Appearance of PCB Report No.: TB-F106202 EXHIBIT 2 - EUT EXTERNAL PHOTOGRAPHS Shenzhen Toby Technology Co., Ltd. FCC ID : X4E01095T Page 4 of 7 Photo 5 Appearance of PCB Photo 6 Appearance of PCB Report No.: TB-F106202 EXHIBIT 2 - EUT EXTERNAL PHOTOGRAPHS Shenzhen Toby Technology Co., Ltd. FCC ID : X4E01095T Page 5 of 7 Photo 7 Appearance of PCB Photo 8 Appearance of PCB Report No.: TB-F106202 EXHIBIT 2 - EUT EXTERNAL PHOTOGRAPHS Shenzhen Toby Technology Co., Ltd. FCC ID : X4E01095T Page 6 of 7 Photo 9 Appearance of PCB

Operational Description

Circuit Description(Transmitter) The data of temperature sensor was dealed by the MCU(IC U2) which the U2 was working supporting with OSC 32.768MHz. As the swith on, the encoded data of the temperature sensor passing through the U2โ€™s Port B1, then the signal was amplified from the RF circuit unit to the antenna. The RF circuit unit was supported by the Crystal of 433.92MHz

Test Report

Report No.: TB-F106202 Shenzhen Toby Technology Co.,Ltd. FCC ID : X4E01095T Page 1 of 18 FCC PART 15.231 MEASUREMENT AND TEST REPORT For EUT Name: Remote Digital Meat Thermometer Item No.: 01095 FCC ID: X4E01095T Serial No.: Not supplied by client Report Number : TB-F106202 Date of Test : Apr. 19-20, 2010 Date of Report : Apr. 21-22, 2010 Prepared for : BASE4 Group, Inc. 2611 Westgrove Drive #109 Carrollton, Texas 75019 USA Prepared by : Shenzhen Toby Technology Co., Ltd. 10/F., A Block, Jiada R & D Bldg., No.5 Songpingshan Road, Science & Technology Park, Nanshan District, Shenzhen, China TEL : 0086-18925263335 Report No.: TB-F106202 Shenzhen Toby Technology Co.,Ltd. FCC ID : X4E01095T Page 2 of 18 TABLE OF CONTENTS TEST REPORT DECLARATION.................................................................................................. 3 1. GENERAL INFORMATION .................................................................................................... 4 1.1. Product Description for Equipment Under Test (EUT).................................................... 4 1.2. Test Standards................................................................................................................... 4 1.3. Related Submittal(s)/Grant(s) ........................................................................................... 5 1.4. Test Methodology ............................................................................................................. 5 1.5. Accessories Equipment List and Details .......................................................................... 5 1.6. EUT Cable List and Details .............................................................................................. 5 1.7. Test Location .................................................................................................................... 5 2. SUMMARY OF TEST RESULTS ............................................................................................ 6 3. ยง15.203 - ANTENNA REQUIREMENT ................................................................................... 7 3.1. Standard Applicable.......................................................................................................... 7 3.2. Test Result ........................................................................................................................ 7 4. ยง15. 205, ยง15.209, ยง15.231 (E) RADIATED EMISSION ......................................................... 8 4.1. Measurement Uncertainty................................................................................................. 8 4.2. Standard Applicable.......................................................................................................... 8 4.3. Test Equipment List and Details....................................................................................... 8 4.4. Test Procedure ..................................................................................................................9 4.5. Corrected Amplitude & Margin Calculation .................................................................... 9 4.6. Environmental Conditions .............................................................................................. 10 4.7. Summary of Test Results/ Plots...................................................................................... 10 5. ยง15. 231(C) 20DB BANDWIDTH TESTING ......................................................................... 13 5.1. Standard Applicable........................................................................................................ 13 5.2. Test Equipment List and Details..................................................................................... 13 5.3. Test Procedure ................................................................................................................ 13 5.4. Environmental Conditions .............................................................................................. 13 5.5. Summary of Test Results/Plots....................................................................................... 13 6. ยง15. 231(E) DEACTIVATION TESTING .............................................................................. 15 6.1. Standard Applicable........................................................................................................ 15 6.2. Test Equipment List and Details..................................................................................... 15 6.3. Test Procedure ................................................................................................................ 15 6.4. Environmental Conditions .............................................................................................. 15 6.5. Summary of Test Results/Plots....................................................................................... 15 Report No.: TB-F106202 Shenzhen Toby Technology Co.,Ltd. FCC ID : X4E01095T Page 3 of 18 TEST REPORT DECLARATION Applicant : BASE4 Group, Inc. Manufacturer : SUNYAN ELECTRONIC CO., LTD. EUT Description : Remote Digital Meat Thermometer Model No. : 01095 The device described above is tested by SEM. Test Compliance Service Co., Ltd. to determine the maximum emission levels emanating from the device. The maximum emission levels are compared to the FCC Part 15 Subpart C limits for both radiation and conduction emissions. The measurement results are contained in this test report and Shenzhen Toby Technology Co., Ltd. is assumed full responsibility for the accuracy and completeness of these measurements. Also, this report shows that the EUT to be technically compliant with the FCC official limits. This report applies to above tested sample only. This report shall not be reproduced in part without written approval of Shenzhen Toby Technology Co., Ltd. Reported by: Date: Apr. 20, 2010 (Jacky Wang) Reviewer: Date: Apr. 22, 2010 (Benny Xu) Approved by: Date: Apr. 23, 2010 (Jโ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: TB-F106202 EXHIBIT 3- EUT TESTING PHOTOGRAPHS Shenzhen Toby Technology Co., Ltd. FCC ID : X4E01095T Page 7 of 7 Photo 1 Radiation Emission Test

Contact Information

Applicant

Joe Thompson(General Manager)
[email protected]972-392-9090Fax: 972-392-9169

Test Firm

SEM.Test Compliance Service Co., Ltd.Jandy So
[email protected]086-755-33663308Fax: 086-755-33663309

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-

Other Applications from BASE4 Group, Inc.

REMOTE DIGITAL MEAT THERMOMETER - FCC ID X4E01095R - BASE4 Group, Inc.
X4E01095R

REMOTE DIGITAL MEAT THERMOMETER

May 05, 2010

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter