Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Axon Signal Unit User Manual Page 1 of 3 Introduction Axon Signal™ is a communication platform that allows auto activation of Axon Flex® cameras, upon activation of an emergency vehicle’s light bar. When equipped with an Axon Signal Unit, light bar activation will start recording in all enabled cameras within range to ensure events are not missed and multiple perspectives are captured. Characteristics Secure Bluetooth broadcast (30 seconds). Activates all enabled cameras in range (approximately 30 feet) Requires an in-car wireless Axon Signal Unit and an Axon Flex controller (battery pack) equipped with Axon Signal technology. Activation only turns the camera “on”; the officer ends the recording with a 3-second press of the EVENT button on the Axon Flex controller. Double-pressing the EVENT button on the Axon Flex controller after the EVENT mode is activated by the Axon Signal Unit will not interfere with recording. Radio Waves Changes or modifications to the equipment not expressly approved by the manufacturer could void the product warranty and the user’s authority to operate the equipment. Your wireless device is a radio transmitter and receiver. It is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission (FCC) of the U.S. Government. These limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to ensure the safety of all persons, regardless of age and health. Before a device model is available for sale to the public, it must be tested and certified to the FCC that it does not exceed the limit established by the government‐ adopted requirement for safe exposure. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning Axon Signal Unit User Manual Page 2 of 3 the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult TASER International Customer Service for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. To comply with FCC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Section 7.1.3 of RSS-GEN This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device. Section 7.1.3 de RSS-GEN Cet appareil est conforme aux normes d’exemption de licence RSS d’Industrie Canada. Son utilisation est soumise aux conditions suivantes : 1) cet appareil ne doit pas causer de brouillage, et 2) doit accepter tout brouillage, y compris le brouillage pouvant entraîner un fonctionnement indésirable. Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. To comply with IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Axon Signal Unit User Manual Page 3 of 3 Section 7.1.2 de RSS-GEN Conformément à la réglementation d’Industrie Canada, le présent émetteur radio ne peut fonctionner qu’au moyen d’une antenne d’un seul type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique pour les autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas celle requise pour établir une communication satisfaisante. Pour se conformer aux limites d’exposition aux radiofréquences fixées par Industrie Canada relativement aux limites d’exposition humaine, l’antenne utilisée pour cet émetteur doit être installée à une distance d’au moins 20 cm de toutes les personnes et ne doit pas être installée ou exploitée conjointement avec d’autres antennes ou émetteurs. RSS 210 Warning Statement: The installer of this equ…
Text truncated - open the document above for the full version.
EXTERNAL PHOTOS Company Name Taser International, Inc Model # T00504 FCC ID # X4GS00831 IC # 8803A‐S00831 Page 1 of 3 EXTERNAL PHOTOS Company Name Taser International, Inc Model # T00504 FCC ID # X4GS00831 IC # 8803A‐S00831 Page 2 of 3 EXTERNAL PHOTOS Company Name Taser International, Inc Model # T00504 FCC ID # X4GS00831 IC # 8803A‐S00831 Page 3 of 3
P/N: MLB0212 DESCRIPTION: LABEL, PRODUCT ID, PHILADELPHIA TASER P/N: T00504 REV: S/N: XXXXXXXX FCC ID: X4GS00831 IC: 8803A-S00831 MIN INPUT: 12VDC 50mA MAC: MLB0212
INTERNAL PHOTOS Company Name Taser International, Inc Model # T00504 FCC ID # X4GS00831 IC # 8803A‐S00831 Page 1 of 2 Shield On looking thru clear plastic cover Shield Off ‐ plastic cover removed, board screwed to enclosure INTERNAL PHOTOS Company Name Taser International, Inc Model # T00504 FCC ID # X4GS00831 IC # 8803A‐S00831 Page 2 of 2
W66 N220 Commerce Court ● Cedarburg, WI 53012 USA ● Phone: 262.375.4400 ● Fax: 262.375.4248 ● www.lsr.com Prepared For: TASER Name: Philadelphia Report: TR 314388 RFX Model: P/N: T00504 LSR: C-2124 Serial: See Section 2.1 Page 1 of 8 i. Title Page ENGINEERING TEST REPORT # TR 314388 RFX LSR Job #: C-2124 RF Exposure Compliance of : Philadelphia Test Date(s): February 9, 12, 14 2015 Prepared For: TASER Attn: Mark Hanchett 17800 N. 85 th St. Scottsdale, AZ 58255 This Test Report is issued under the Authority of: Adam Alger, EMC Engineer Signature: Date: 3-26-15 This Test Report may not be reproduced, except in full, without written approval of LS Research, LLC. Prepared For: TASER Name: Philadelphia Report: TR 314388 RFX Model: P/N: T00504 LSR: C-2124 Serial: See Section 2.1 Page 2 of 8 ii. Table of Contents Table of Contents i. Title Page ................................................................................................................................... 1 ii. Table of Contents ....................................................................................................................... 2 iii. LS Research, LLC ...................................................................................................................... 3 1.0 Conformance Summary ............................................................................................................. 4 2.0 Equipment Under Test (EUT) Information ................................................................................ 4 2.1 Product Description ................................................................................................................... 4 2.2 Additional Information .............................................................................................................. 4 3.0 RF Conducted Measurement Data ............................................................................................. 5 4.0 MPE Calculation ........................................................................................................................ 6 5.0 Industry Canada Low Power Exemption ................................................................................... 7 Prepared For: TASER Report: TR 314388 RFX LSR: C-2124 iii. LS Research, LLC As an EMC Testing Laboratory, our Accreditation and Assessments are recognized through the following: A2LA – American Association for Laboratory Accreditation Accreditation based on ISO/IEC 17025: 2005 A2LA Certificate Number: 1255.01 Federal Communications Commission (FCC) Listing of 3 Meter Semi-Anechoic Chamber based on Title 47 CFR FCC Registration Number: 90756 Industry Canada On file, 3 Meter Semi- Anechoic Chamber based o File Number: IC 3088-A On file, 3 and 10 Meter OATS based on RSS File Number: IC 3088 U. S. Conformity Assessment Body (CAB) Validation Validated by the European Commission as a U. S. Competent Body operating under S./EU, Mutual Recognition Agreement (MRA) operating under the European Union Electromagnetic Compatibility 10.2). Date of Validation: January 16, 2001 Validated by the European Commissio /EU, Mutual Recognition Agreement (MRA) operating under the European Union Telecommunication Equipment Date of Validation: November 20, 2002 Notified Body Identification Number: 1243 Name: Philadelphia Model: P/N: T00504 Serial: See Section 2.1 Page 3 of 8 LS Research, LLC in Review As an EMC Testing Laboratory, our Accreditation and Assessments are recognized through the American Association for Laboratory Accreditation Accreditation based on ISO/IEC 17025: 2005 with Electrical (EMC) Scope of ertificate Number: 1255.01 Federal Communications Commission (FCC) – USA Anechoic Chamber based on Title 47 CFR – Part 2.948 FCC Registration Number: 90756 Anechoic Chamber based on RSS-212 – Issue 1 On file, 3 and 10 Meter OATS based on RSS-212 – Issue 1 U. S. Conformity Assessment Body (CAB) Validation Validated by the European Commission as a U. S. Competent Body operating under S./EU, Mutual Recognition Agreement (MRA) operating under the European Union Electromagnetic Compatibility –Council Directive 2004/108/EC (formerly 89/336/EEC, Article Date of Validation: January 16, 2001 Validated by the European Commission as a U.S. Notified Body operating under the U.S. /EU, Mutual Recognition Agreement (MRA) operating under the European Union Telecommunication Equipment – Council Directive 99/5/EC, Annex V. Date of Validation: November 20, 2002 ion Number: 1243 As an EMC Testing Laboratory, our Accreditation and Assessments are recognized through the with Electrical (EMC) Scope of Accreditation Part 2.948 Validated by the European Commission as a U. S. Competent Body operating under the U. S./EU, Mutual Recognition Agreement (MRA) operating under the European Union Council Directive 2004/108/EC (formerly 89/336/EEC, Article n as a U.S. Notified Body operating under the U.S. /EU, Mutual Recognition Agreement (MRA) operating under the European Union Prepared For: TASER Name: Philadelphia Report: TR 314388 RFX Model: P/N: T00504 LSR: C-2124 Serial: See Section 2.1 Page 4 of 8 1.0 Conformance Summary The EUT was found to MEET the MPE threshold for FCC §2.1091(mobile) using methods of FCC KDB 447498 D01 General RF Exposure Guidance v05r02 as a standalone device. 2.0 Equipment Under Test (EUT) Information The following information has been supplied by the applicant. Product Name: Philadelphia Model Number: P/N: T00504 Serial Number: 127 (Conducted Sample) 131 (Radiated Sample) FCC ID X4GS00831 IC Number 8803A-S00831 2.1 Product Description Bluetooth Low Energy product. 2.2 Additional Information EUT programmed for continuous transmit or receive via FTDI to USB cable connected to laptop computer running Broadcom Blue Tool v 1.8.4.6. Test channels; Low Channel (2402 MHz), Mid Channel (2440 MHz), and High Channel (2480 MHz). Prepared For: TASER Name: Philadelphia Report: TR 314388 RFX Model: P/N: T00504 LSR: C-2124 Serial: See Section 2.1 Page 5…
Text truncated - open the document above for the full version.
W66 N220 Commerce Court ● Cedarburg, WI 53012 USA ● Phone: 262.375.4400 ● Fax: 262.375.4248 ● www.lsr.com Prepared For: TASER Name: Philadelphia Report: TR 314388 Model: P/N: T00504 LSR: C-2124 Serial: See Section 3.1 Page 1 of 30 i. Title Page ENGINEERING TEST REPORT # TR 314388A LSR Job #: C-2124 Compliance Testing of : Philadelphia Test Date(s): February 9, 12, 14 2015 Prepared For: TASER Attn: Mark Hanchett 17800 N. 85 th St. Scottsdale, AZ 58255 This Test Report is issued under the Authority of: Adam Alger, EMC Engineer Signature: Date: 3-26-15 Quality Assurance by: Khairul Aidi Zainal, EMC Lab Supervisor Signature: Date: 3-13-15 Report by: Adam Alger, EMC Engineer Signature: Date: 3-11-15 This Test Report may not be reproduced, except in full, without written approval of LS Research, LLC. Prepared For: TASER Name: Philadelphia Report: TR 314388 Model: P/N: T00504 LSR: C-2124 Serial: See Section 3.1 Page 2 of 30 ii. Table of Contents Table of Contents i. Title Page ................................................................................................................................... 1 ii. Table of Contents ....................................................................................................................... 2 iii. LS Research, LLC in Review .................................................................................................... 3 1.0 Summary of Test Report ............................................................................................................ 4 2.0 Test Facilities ............................................................................................................................. 4 3.0 Client Information ...................................................................................................................... 5 3.1 Equipment Under Test (EUT) Information ................................................................................ 5 3.2 Product Information ................................................................................................................... 5 3.3 Modifications Incorporated In the EUT for Compliance Purposes ........................................... 5 3.4 Deviations & Exclusions from Test Specifications ................................................................... 5 3.5 Additional Information .............................................................................................................. 5 4.0 Conditions of Test ...................................................................................................................... 6 5.0 Test Equipment .......................................................................................................................... 6 6.0 Conformance Summary ............................................................................................................. 7 Appendix A – Test Equipment ............................................................................................................. 8 Appendix B – Test Data ........................................................................................................................ 9 B.1 – RF Conducted Emissions ........................................................................................................ 9 B.2 – Radiated Emissions ............................................................................................................... 18 Appendix C - Uncertainty Summary .................................................................................................. 28 Appendix D - References .................................................................................................................... 29 Prepared For: TASER Report: TR 314388 LSR: C-2124 iii. LS Research, LLC in Review As an EMC Testing Laboratory, our Accreditation and Assessments are recognized through the following: A2LA – American Association for Laboratory Accreditation Accreditation based on ISO/IEC 17025: 2005 A2LA Certificate Number: 1255.01 Federal Communications Commission (FCC) Listing of 3 Meter Semi-Anechoic FCC Registration Number: 90756 Industry Canada On file, 3 Meter Semi- Anechoic Chamber based on RSS File Number: IC 3088-A On file, 3 and 10 Meter OATS based on RSS File Number: IC 3088 U. S. Conformity Assessment Body (CAB) Validation Validated by the European Commission as a U. S. Competent Body operating under the U. S./EU, Mutual Recognition Agreement (MRA) operating under the European Union Electromagnetic Compatibilit 10.2). Date of Validation: January 16, 2001 Validated by the European Commission as a U.S. Notified Body operating under the U.S. /EU, Mutual Recognition Agreement (MRA) operating under the E Telecommunication Equipment Date of Validation: November 20, 2002 Notified Body Identification Number: 1243 Name: Philadelphia Model: P/N: T00504 Serial: See Section 3.1 Page 3 of 30 LS Research, LLC in Review LS Research, LLC in Review As an EMC Testing Laboratory, our Accreditation and Assessments are recognized through the American Association for Laboratory Accreditation Accreditation based on ISO/IEC 17025: 2005 with Electrical (EMC) Scope of A2LA Certificate Number: 1255.01 Federal Communications Commission (FCC) – USA Anechoic Chamber based on Title 47 CFR – Part 2.948 FCC Registration Number: 90756 Anechoic Chamber based on RSS-212 – Issue 1 On file, 3 and 10 Meter OATS based on RSS-212 – Issue 1 U. S. Conformity Assessment Body (CAB) Validation Validated by the European Commission as a U. S. Competent Body operating under the U. S./EU, Mutual Recognition Agreement (MRA) operating under the European Union Electromagnetic Compatibility –Council Directive 2004/108/EC (formerly 89/336/EEC, Article Date of Validation: January 16, 2001 Validated by the European Commission as a U.S. Notified Body operating under the U.S. /EU, Mutual Recognition Agreement (MRA) operating under the European Union Telecommunication Equipment – Council …
Text truncated - open the document above for the full version.
TEST SETUP PHOTOS Company Name Taser International, Inc Model # T00504 FCC ID # X4GS00831 IC # 8803A‐S00831 Page 1 of 4 Conducted Radiated Flat TEST SETUP PHOTOS Company Name Taser International, Inc Model # T00504 FCC ID # X4GS00831 IC # 8803A‐S00831 Page 2 of 4 Radiated Horizontal Radiated Vertical Picture 1 TEST SETUP PHOTOS Company Name Taser International, Inc Model # T00504 FCC ID # X4GS00831 IC # 8803A‐S00831 Page 3 of 4 Radiated Vertical Picture 2 TEST SETUP PHOTOS Company Name Taser International, Inc Model # T00504 FCC ID # X4GS00831 IC # 8803A‐S00831 Page 4 of 4 Radiated Above 1 GHz
17800 N. 85th St. · Scottsdale, Arizona · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.25 mW |
Law Enforcement Training
Equipment Class
DTS - Digital Transmission SystemOutdoor LTE wireless camera (AX1054)
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Law Enforcement Training
Equipment Class
DTS - Digital Transmission System
Fleet 3 Wireless Mic
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Fleet Hub
Equipment Class
DTS - Digital Transmission System