X4YNBL301PNebulaN301 Wireless-N Router

NEXXT SOLUTIONS
NebulaN301 Wireless-N Router - FCC ID X4YNBL301P - NEXXT SOLUTIONS
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 16, 2021
Application Purpose
Original Equipment
Date of Application
Apr 16, 2021
Equipment Note
NebulaN301 Wireless-N Router
Frequency Range
2412.00000000 - 2462.00000000
Company
NEXXT SOLUTIONS
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

Project No.: 2103C089 Page 1 of 11 ATTACHMENT PHOTOGRAPHS OF EUT Project No.: 2103C089 Page 2 of 11 Project No.: 2103C089 Page 3 of 11 Project No.: 2103C089 Page 4 of 11 Project No.: 2103C089 Page 5 of 11 Project No.: 2103C089 Page 6 of 11

Internal Photos

Project No.: 2103C089 Page 7 of 11 Ant. 1 Ant. 2 Project No.: 2103C089 Page 8 of 11 Project No.: 2103C089 Page 9 of 11 Project No.: 2103C089 Page 10 of 11 Project No.: 2103C089 Page 11 of 11

RF Exposure Info

Report No.: BTL-FCCP-2-2103C089 Page 1 of 4 FCC RF EXPOSURE REPORT FCC ID: X4YNBL301P Project No. : 2103C089 Equipment : NebulaN301 Wireless-N Router Brand Name : NEXXT Test Model : NCR-N301 Series Model : N/A Applicant : NEXXT SOLUTIONS Address : 3505 N.W 107TH AVE. MIAMI, FL 33178 Manufacturer : NEXXT SOLUTIONS Address : 3505 N.W 107TH AVE. MIAMI, FL 33178 Date of Receipt : Mar. 09, 2021 Date of Test : Mar. 09, 2021 ~ Mar. 19, 2021 Issued Date : Mar. 31, 2021 Report Version : R00 Test Sample : Engineering Sample No.: DG2021030894 Standard(s) : FCC Guidelines for Human Exposure IEEE C95.1 & FCC Part 2.1091 FCC Title 47 Part 2.1091, OET Bulletin 65 Supplement C The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. Prepared by : Chella Zheng Approved by : Ethan Ma Add: No.3, Jinshagang 1st Road, Shixia, Dalang Town,Dongguan, Guangdong, China. Te l : +86-769-8318-3000 Web: www.newbtl.com Report No.: BTL-FCCP-2-2103C089 Page 2 of 4 REPORT ISSUED HISTORY Report Version Description Issued Date R00 Original Issue Mar. 31, 2021 Report No.: BTL-FCCP-2-2103C089 Page 3 of 4 1. TEST FACILITY The test facilities used to collect the test data in this report is at the location of No.3,Jinshagang 1st Road, Shixia, Dalang Town, Dongguan, Guangdong, China. BTL's Test Firm Registration Number for FCC: 357015 BTL's Designation Number for FCC: CN1240 2. MPE CALCULATION METHOD Calculation Method of RF Safety Distance: where: S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Table for Filed Antenna: For 2.4GHz: Ant. Brand Model Name Antenna Type Connector Gain (dBi) 1 N/A N/A Dipole N/A 4.65 2 N/A N/A Dipole N/A 4.65 Note: 1) The antenna gain is provided by the manufacturer. 2) This EUT supports CDD, and all antennas have the same gain, Directional gain = G ANT +Array Gain. For power measurements, Array Gain=0dB (N ANT ≤4), so the Directional gain=4.65. For power spectral density measurements, N ANT =2, N SS = 1. So the Directional gain=G ANT +Array Gain=G ANT +10log(N ANT / N SS )dBi=4.65+10log(2/1)dBi=7.66. Then, the power spectral density limit is 8-(7.66-6)=6.34 Table for Antenna Configuration: Operating Mode TX Mode 1TX 2TX IEEE 802.11b V (Ant. 1) - IEEE 802.11g V (Ant. 1) - IEEE 802.11n(HT20) - V (Ant. 1 + Ant. 2) IEEE 802.11n(HT40) - V (Ant. 1 + Ant. 2) . Report No.: BTL-FCCP-2-2103C089 Page 4 of 4 3. TEST RESULTS For 2.4GHz: Antenna Gain (dBi) Antenna Gain (numeric) Max. Output Power (dBm) Max. Output Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Test Result 4.65 2.9174 28.58 721.1075 0.41875 1 Complies End of Test Report

Test Report

Report No.: BTL-FCCP-1-2103C089 Page 1 of 113 FCC Radio Test Report FCC ID: X4YNBL301P This report concerns: Original Grant Project No. : 2103C089 Equipment : NebulaN301 Wireless-N Router Brand Name : NEXXT Test Model : NCR-N301 Series Model : N/A Applicant : NEXXT SOLUTIONS Address : 3505 N.W 107TH AVE. MIAMI, FL 33178 Manufacturer : NEXXT SOLUTIONS Address : 3505 N.W 107TH AVE. MIAMI, FL 33178 Date of Receipt : Mar. 09, 2021 Date of Test : Mar. 09, 2021 ~ Mar. 19, 2021 Issued Date : Mar. 31, 2021 Report Version : R00 Test Sample : Engineering Sample No.:DG2021030894 Standard(s) : FCC Part15, Subpart C (15.247) ANSI C63.10-2013 FCC KDB 558074 D01 15.247 Meas Guidance v05r02 The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. Prepared by : Chella Zheng Approved by : Ethan Ma Add: No.3, Jinshagang 1st Road, Shixia, Dalang Town,Dongguan, Guangdong, China. Te l : +86-769-8318-3000 Web: www.newbtl.com Report No.: BTL-FCCP-1-2103C089 Page 2 of 113 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL shall have no liability for any declarations, inferences or generalizations drawn by the client or others from BTL issued reports. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, A2LA, or any agency of the U.S. Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-1-2103C089 Page 3 of 113 Table of Contents Page REPORT ISSUED HISTORY 6 1 . SUMMARY OF TEST RESULTS 7 1.1 TEST FACILITY 8 1.2 MEASUREMENT UNCERTAINTY 8 1.3 TEST ENVIRONMENT CONDITIONS 9 2 . GENERAL INFORMATION 10 2.1 GENERAL DESCRIPTION OF EUT 10 2.2 DESCRIPTION OF TEST MODES 12 2.3 PARAMETERS OF TEST SOFTWARE 13 2.4 DUTY CYCLE 14 2.5 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 15 2.6 SUPPORT UNITS 15 3 . AC POWER LINE CONDUCTED EMISSIONS TEST 16 3.1 LIMIT 16 3.2 TEST PROCEDURE 16 3.3 DEVIATION FROM TEST STANDARD 16 3.4 TEST SETUP 17 3.5 EUT OPERATION CONDITIONS 17 3.6 TEST RESULTS 17 4 . RADIATED EMISSIONS TEST 18 4.1 LIMIT 18 4.2 TEST PROCEDURE 19 4.3 DEVIATION FROM TEST STANDARD 19 4.4 TEST SETUP 20 4.5 EUT OPERATION CONDITIONS 21 4.6 TEST RESULTS - 9 KHZ TO 30 MHZ 21 4.7 TEST RESULTS - 30 MHZ TO 1000 MHZ 21 4.8 TEST RESULTS - ABOVE 1000 MHZ 21 5 . BANDWIDTH TEST 22 5.1 LIMIT 22 5.2 TEST PROCEDURE 22 5.3 DEVIATION FROM STANDARD 22 5.4 TEST SETUP 22 Report No.: BTL-FCCP-1-2103C089 Page 4 of 113 Table of Contents Page 5.5 EUT OPERATION CONDITIONS 22 5.6 TEST RESULTS 22 6 . MAXIMUM OUTPUT POWER TEST 23 6.1 LIMIT 23 6.2 TEST PROCEDURE 23 6.3 DEVIATION FROM STANDARD 23 6.4 TEST SETUP 23 6.5 EUT OPERATION CONDITIONS 23 6.6 TEST RESULTS 23 7 . CONDUCTED SPURIOUS EMISSIONS 24 7.1 LIMIT 24 7.2 TEST PROCEDURE 24 7.3 DEVIATION FROM STANDARD 24 7.4 TEST SETUP 24 7.5 EUT OPERATION CONDITIONS 24 7.6 TEST RESULTS 24 8 . POWER SPECTRAL DENSITY TEST 25 8.1 LIMIT 25 8.2 TEST PROCEDURE 25 8.3 DEVIATION FROM STANDARD 25 8.4 TEST SETUP 25 8.5 EUT OPERATION CONDITIONS 25 8.6 TEST RESULTS 25 9 . MEASUREMENT INSTRUMENTS LIST 26 10 . EUT TEST PHOTO 28 APPENDIX A - AC POWER LINE CONDUCTED EMISSIONS 32 APPENDIX B - RADIATED EMISSION - 9 KHZ TO 30 MHZ 37 APPENDIX C - RADIATED EMISSION - 30 MHZ TO 1000 MHZ 42 APPENDIX D - RADIATED EMISSION- ABOVE 1000 MHZ 45 APPENDIX E - BANDWIDTH 94 APPENDIX F - MAXIMUM OUTPUT POWER 99 APPENDIX G - CONDUCTED SPURIOUS EMISSIONS 103 Report No.: BTL-FCCP-1-2103C089 Page 5 of 113 Table of Contents Page APPENDIX H - POWER SPECTRAL DENSITY 110 Report No.: BTL-FCCP-1-2103C089 Page 6 of 113 REPORT ISSUED HISTORY Report Version Description Issued Date R00 Original Issue. Mar. 31, 2021 Report No.: BTL-FCCP-1-2103C089 Page 7 of 113 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standard(s): FCC Part15, Subpart C (15.247) Standard(s) Section Test Item Test Result Judgment Remark 15.207 AC Power Line Conducted Emissions APPENDIX A N/A ------ 15.247(d) 15.205(a) 15.209(a) Radiated Emissions APPENDIX B APPENDIX C APPENDIX D PASS ------ 15.247(a)(2) Bandwidth APPENDIX E PASS ------ 15.247(b)(3) Maximum Output Power APPENDIX F PASS ------ 15.247(d) Conducted Spurious Emissions APPENDIX G PASS ------ 15.247(e) Power Spectral Density APPENDIX H PASS ------ 15.203 Antenna Requirement ------ PASS Note(2) Note: (1) “N/A” denotes test is not applicable in this test report. (2) The device what use a permanently attached antenna were considered…

Text truncated - open the document above for the full version.

Test Report

Report No.: BTL-FCCP-1-2103C089 Page 106 of 113 Test Mode TX N-20M Mode_Ant. 1 Bandedge-CH01 Bandedge-CH11 CH01 – 10th Harmonic of the fundamental frequency CH06 – 10th Harmonic of the fundamental frequency CH11 – 10th Harmonic of the fundamental frequency Report No.: BTL-FCCP-1-2103C089 Page 107 of 113 Test Mode TX N-20M Mode_Ant. 2 Bandedge-CH01 Bandedge-CH11 CH01 – 10th Harmonic of the fundamental frequency CH06 – 10th Harmonic of the fundamental frequency CH11 – 10th Harmonic of the fundamental frequency Report No.: BTL-FCCP-1-2103C089 Page 108 of 113 Test Mode TX N-40M Mode_Ant. 1 Bandedge-CH03 Bandedge-CH09 CH03 – 10th Harmonic of the fundamental frequency CH06 – 10th Harmonic of the fundamental frequency CH09 – 10th Harmonic of the fundamental frequency Report No.: BTL-FCCP-1-2103C089 Page 109 of 113 Test Mode TX N-40M Mode_Ant. 2 Bandedge-CH03 Bandedge-CH09 CH03 – 10th Harmonic of the fundamental frequency CH06 – 10th Harmonic of the fundamental frequency CH09 – 10th Harmonic of the fundamental frequency Report No.: BTL-FCCP-1-2103C089 Page 110 of 113 APPENDIX H - POWER SPECTRAL DENSITY Report No.: BTL-FCCP-1-2103C089 Page 111 of 113 Test Mode TX B Mode Channel Frequency (MHz) Power Spectral Density (dBm/3kHz) Max. Limit (dBm/3kHz) Result 01 2412 -4.95 6.34 Complies 06 2437 -4.37 6.34 Complies 11 2462 -4.51 6.34 Complies CH01 CH06 CH11 Test Mode TX G Mode Channel Frequency (MHz) Power Spectral Density (dBm/3kHz) Max. Limit (dBm/3kHz) Result 01 2412 -9.51 6.34 Complies 06 2437 -12.39 6.34 Complies 11 2462 -10.48 6.34 Complies CH01 CH06 CH11 Report No.: BTL-FCCP-1-2103C089 Page 112 of 113 Test Mode TX N-20M Mode_Ant. 1 Channel Frequency (MHz) Power Spectral Density (dBm/3kHz) Max. Limit (dBm/3kHz) Result 01 2412 -8.81 6.34 Complies 06 2437 -9.95 6.34 Complies 11 2462 -11.28 6.34 Complies CH01 CH06 CH11 Test Mode TX N-20M Mode_Ant. 2 Channel Frequency (MHz) Power Spectral Density (dBm/3kHz) Max. Limit (dBm/3kHz) Result 01 2412 -10.88 6.34 Complies 06 2437 -11.12 6.34 Complies 11 2462 -11.83 6.34 Complies CH01 CH06 CH11 Test Mode TX N-20M Mode_Total Channel Frequency (MHz) Power Spectral Density (dBm/3kHz) Max. Limit (dBm/3kHz) Result 01 2412 -6.71 6.34 Complies 06 2437 -7.49 6.34 Complies 11 2462 -8.54 6.34 Complies Report No.: BTL-FCCP-1-2103C089 Page 113 of 113 Test Mode TX N-40M Mode_Ant. 1 Channel Frequency (MHz) Power Spectral Density (dBm/3kHz) Max. Limit (dBm/3kHz) Result 03 2422 -12.80 6.34 Complies 06 2437 -13.42 6.34 Complies 09 2452 -13.23 6.34 Complies CH03 CH06 CH09 Test Mode TX N-40M Mode_Ant. 2 Channel Frequency (MHz) Power Spectral Density (dBm/3kHz) Max. Limit (dBm/3kHz) Result 03 2422 -13.73 6.34 Complies 06 2437 -13.78 6.34 Complies 09 2452 -14.70 6.34 Complies CH03 CH06 CH09 Test Mode TX N-40M Mode_Total Channel Frequency (MHz) Power Spectral Density (dBm/3kHz) Max. Limit (dBm/3kHz) Result 03 2422 -10.23 6.34 Complies 06 2437 -10.59 6.34 Complies 09 2452 -10.89 6.34 Complies End of Test Report

Test Setup Photos

Report No.: BTL-FCCP-1-2103C089 Page 28 of 113 10. EUT TEST PHOTO AC Power Line Conducted Emissions Test Photos Report No.: BTL-FCCP-1-2103C089 Page 29 of 113 Radiated Emissions Test Photos 9 kHz to 30 MHz Report No.: BTL-FCCP-1-2103C089 Page 30 of 113 Radiated Emissions Test Photos 30 MHz to 1 GHz Report No.: BTL-FCCP-1-2103C089 Page 31 of 113 Radiated Emissions Test Photos Above 1 GHz

Contact Information

Applicant

Albert Mizrachi(Vice president of product development)
[email protected]786-280-7600Fax: 305 477- 5694

Test Firm

BTL Inc.Sophia Huang
[email protected]+86-769-83183000

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz721.11 mW
Confidentiality
Long Term
Grant Notes
Output power listed is peak conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. Integrators and End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from NEXXT SOLUTIONS

Smart Camera - FCC ID X4YHACIF25W - NEXXT SOLUTIONS
X4YHACIF25W

Smart Camera

Aug 06, 2026

Equipment Class

DTS - Digital Transmission System
Smart Camera - FCC ID X4YHACOP40SL - NEXXT SOLUTIONS
X4YHACOP40SL

Smart Camera

Jul 07, 2026

Equipment Class

PCB - PCS Licensed Transmitter
Xmas string lights - FCC ID X4YHABXL20 - NEXXT SOLUTIONS
X4YHABXL20

Xmas string lights

Jan 14, 2026

Equipment Class

DTS - Digital Transmission System
AROMA DIFFUSER - FCC ID X4YHAAD300 - NEXXT SOLUTIONS
X4YHAAD300

AROMA DIFFUSER

Jan 06, 2026

Equipment Class

DTS - Digital Transmission System
Camera - FCC ID X4YHACIP15 - NEXXT SOLUTIONS
X4YHACIP15

Camera

Sep 28, 2025

Equipment Class

DTS - Digital Transmission System