FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. NEXXT SOLUTIONS/
  3. X4YTRNTY3G

X4YTRNTY3G3G/4G TRINITY PORTABLE SIM-BASED WI-FI HOTSPOT

NEXXT SOLUTIONS
3G/4G TRINITY PORTABLE SIM-BASED WI-FI HOTSPOT - FCC ID X4YTRNTY3G - NEXXT SOLUTIONS
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 24, 2015
Application Purpose
Original Equipment
Date of Application
Nov 24, 2015
Equipment Note
3G/4G TRINITY PORTABLE SIM-BASED WI-FI HOTSPOT
Frequency Range
2412.00000000 - 2462.00000000
Company
NEXXT SOLUTIONS
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

CERTIFICATE OF COMPLIANCE Authorized under Declaration of Conformity according to 47 CFR, Part 2 and Part 15 of the FCC Rules. The product listed in follows was (were) tested in the BTL EMC Laboratory to comply with the criteria limits Class B of conducted and radiated emissions of the Technical Standards FCC Part 15, Subpart B, established by the FCC, USA. Equipment 3G/4G TRINITY PORTABLE SIM-BASED WI-FI HOTSPOT Model Name ARNPR3G5U1 Brand Name NEXXT Applicant NEXXT SOLUTIONS Address 3505 N.W 107TH AVE,MIAMI,FL,33178 Standard(s) FCC Part 15, Subpart B: 2014 ANSI C63.4-2014 Report(s) BTL-FCCE-1-1510C002 The test data, data evaluation, and equipment configuration contained in our test report(s) above was (were) obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment standard and technical standard(s). The test data contained in the referenced test report relate only to the EUT sample and item(s) tested. Andy Chiu Authorized Signatory BTL INC. B1, No. 37, Lane 365, Yang-Guang St., Nei-Hu District, Taipei City 114, Taiwan. TEL:+886-2-2657-3299 FAX:+886-2-2657-3331

External Photos

Project No.: 1510C002 Page 2 of 15 Project No.: 1510C002 Page 3 of 15 Project No.: 1510C002 Page 4 of 15

Internal Photos

Project No.: 1510C002 Page 5 of 15 Project No.: 1510C002 Page 6 of 15 Project No.: 1510C002 Page 7 of 15 Project No.: 1510C002 Page 8 of 15 Project No.: 1510C002 Page 9 of 15 Project No.: 1510C002 Page 10 of 15 Project No.: 1510C002 Page 11 of 15 Project No.: 1510C002 Page 12 of 15 Project No.: 1510C002 Page 13 of 15 Project No.: 1510C002 Page 14 of 15 Project No.: 1510C002 Page 15 of 15

RF Exposure Info

Report No.: BTL-FCC-SAR-1510C002 Page 1 of 42 Report Format Version: 0.0.1 FCC SAR Test Report FCC ID: X4YTRNTY3G Project No. : 1510C002 Equipment : 3G/4G TRINITY PORTABLE SIM-BASED WI-FI HOTSPOT Model Name : ARNPR3G5U1 Applicant : NEXXT SOLUTIONS Address : 3505 N.W 107TH AVE,MIAMI,FL,33178 Date of Receipt : Oct. 08, 2015 Date of Test : Oct. 22, 2015 ~ Oct. 28, 2015 Issued Date : Nov. 03, 2015 Tested by : BTL Inc. PREPARED BY : (Super Jiang/ Technical Engineer) APPROVED BY : (Steven Lu / Technical Manager) B T L I N C . No.3, Jinshagang 1st Road, Shixia, Dalang Town, Dongguan, Guangdong, China. TEL: +86-769-8318-3000 FAX: +86-769-8319-6000 Report No.: BTL-FCC-SAR-1510C002 Page 2 of 42 Report Format Version: 0.0.1 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML), or National Institute of Standards and Technology (NIST) . BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL shall have no liability for any declarations, inferences or generalizations drawn by the client or others from BTL issued reports. BTL’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and BTL-self, extracts from the test report shall not be reproduced except in full with BTL’s authorized written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO Guide17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Report No.: BTL-FCC-SAR-1510C002 Page 3 of 42 Report Format Version: 0.0.1 Table of Contents Page 1 . GENERAL SUMMARY 6 2 . RF EMISSIONS MEASUREMENT 7 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3 . GENERAL INFORMATION 8 3.1 STATEMENT OF COMPLIANCE 8 3.2 LABORATORY ENVIRONMENT 9 3.3 MAIN TEST INSTRUMENTS 10 4 .SAR MEASUREMENTS SYSTEM CONFIGURATION 11 4.1 SAR MEASUREMENT SET-UP 11 4.2 DASY5E-FIELDPROBESYSTEM 12 5 . SYSTEM VERIFICATION PROCEDURE 20 5.1 TISSUE VERIFICATION 20 5.2 SYSTEM CHECK 22 5.3 SYSTEM CHECK PROCEDURE 23 6 .SAR MEASUREMENT VARIABILITY AND UNCERTAINTY 24 6.1 SAR MEASUREMENT VARIABILITY 24 6.2 SAR MEASUREMENT UNCERTAINTY 24 7 . OPERATIONAL CONDITIONS DURING TEST 25 7.1 SAR TEST CONFIGURATION 25 7.1 .1 GSM TEST CONFIGURATION 25 7.1.2 UMTS TEST CONFIGURATION 26 7.1.4 WIFI TEST CONFIGURATION 30 7.1.4.1 2.4G SAR TEST REQUIREMENTS 30 7.2 TEST POSITION 31 8 . POWER TEST RESULT 32 9.SAR TEST RESULTS 38 9.1 SAR MEASUREMENT RESULT 40 Report No.: BTL-FCC-SAR-1510C002 Page 4 of 42 Report Format Version: 0.0.1 Table of Contents Page 10. SIMULTANEOUS TRANSMISSION CONDITIONS 42 APPENDIX 43 1. TEST LAYOUT 43 Appendix A. SAR Plots of System Verification Appendix B. SAR Plots of SAR Measurement Appendix C. Calibration Certificate for Probe and Dipole Appendix D. Photographs of the Test Set-Up Report No.: BTL-FCC-SAR-1510C002 Page 5 of 42 Report Format Version: 0.0.1 REPORT ISSUED HISTORY Issued No. Description Issued Date BTL-FCC-SAR-1510C002 Original Issue. Nov. 03, 2015 Report No.: BTL-FCC-SAR-1510C002 Page 6 of 42 Report Format Version: 0.0.1 1. GENERAL SUMMARY Equipment 3G/4G TRINITY PORTABLE SIM-BASED WI-FI HOTSPOT Model Name ARNPR3G5U1 Brand Name NEXXT Manufacturer NEXXT SOLUTIONS Address 3505 N.W 107TH AVE,MIAMI,FL,33178 Standard(s) FCC 47CFR §2.1093 Radio frequency Radiation Exposure Evaluation: Portable Devices ANSI Std C95.1-1992Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz – 300 GHz.( IEEE Std C95.1-1991) IEEE Std 1528-2013Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques KDB941225 D01 3G SAR Procedures v03r01 KDB941225 D06 Hotspot Mode V02r01 KDB447498 D01 General RF Exposure Guidance v06 KDB248227 D01 802. 11 Wi-Fi SAR v02r02 KDB865664 D01 SAR measurement 100 MHz to 6 GHz v01r04 KDB865664 D02 SAR Reporting v01r02 KDB690783 D01 SAR Listings on Grants v01r03 The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. BTL-FCC-SAR-1510C002) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment standard and technical standard(s). Report No.: BTL-FCC-SAR-1510C002 Page 7 of 42 Report Format Version: 0.0.1 2. RF EMISSIONS MEASUREMENT 2.1 TEST FACILITY The test facilities used to collect the test data in this report is SAR room at the location of No.3,Jinshagang 1st Road, ShiXia, Dalang Town,Dong Guan, China.523792 2.2 MEASUREMENT UNCERTAINTY Note: Per KDB865664 D01 SAR Measurement 100 MHz to 6 GHz v01r03,when the highest measured 1-g SAR within a frequency band is < 1.5 W/kg, the extensive SAR measurement uncertainty analysis described in IEEE Std 1528-2013 is not required in SAR reports submitted for equipment approval. The equivalent ratio (1.5/1.6) is applied to extremity and occupational exposure conditions. Report No.: BTL-FCC-SAR-1510C002 Page 8 of 42 Report Format Version: 0.0.1 3. GENERAL INFORMATION 3.1 STATEMENT OF COMPLIANCE Equipment Class Mode Highest Body (10mm) SAR-1g(W/kg) PCE GSM850 1.24 GSM1900 0.76 WCDMA Band II 0.67 WCD…

Text truncated - open the document above for the full version.

Test Report

Report No.: BTL-FCCP-1-1510C002 Page 1 of 121 FCC Radio Test Report FCC ID: X4YTRNTY3G This report concerns (check one): Original Grant Class II Change Project No. : 1510C002 Equipment : 3G/4G TRINITY PORTABLE SIM-BASED WI-FI HOTSPOT Model Name : ARNPR3G5U1 Applicant : NEXXT SOLUTIONS Address : 3505 N.W 107TH AVE,MIAMI,FL,33178 Date of Receipt : Oct. 08, 2015 Date of Test : Oct. 08, 2015 ~ Nov. 02, 2015 Issued Date : Nov. 03, 2015 Tested by : BTL Inc. Testing Engineer : (Shawn Xiao) Technical Manager : (David Mao) Authorized Signatory : (Steven Lu) BTL INC. No.3, Jinshagang 1st Road, Shixia, Dalang Town, Dongguan, Guangdong, China. TEL: +86-769-8318-3000 FAX: +86-769-8319-6000 Report No.: BTL-FCCP-1-1510C002 Page 2 of 121 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C, or National Institute of Standards and Technology (NIST) of U.S.A. BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL shall have no liability for any declarations, inferences or generalizations drawn by the client or others from BTL issued reports. BTL’s report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and BTL-self, extracts from the test report shall not be reproduced except in full with BTL’s authorized written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Report No.: BTL-FCCP-1-1510C002 Page 3 of 121 Table of Contents Page 1 . CERTIFICATION 6 2 . SUMMARY OF TEST RESULTS 7 2.1 TEST FACILITY 8 2.2 MEASUREMENT UNCERTAINTY 8 3 . GENERAL INFORMATION 9 3.1 GENERAL DESCRIPTION OF EUT 9 3.2 DESCRIPTION OF TEST MODES 10 3.3 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 11 3.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 12 3.5 DESCRIPTION OF SUPPORT UNITS 12 4 . EMC EMISSION TEST 13 4.1 CONDUCTED EMISSION MEASUREMENT 13 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 13 4.1.2 TEST PROCEDURE 13 4.1.3 DEVIATION FROM TEST STANDARD 13 4.1.4 TEST SETUP 14 4.1.5 EUT OPERATING CONDITIONS 14 4.1.6 EUT TEST CONDITIONS 14 4.1.7 TEST RESULTS 14 4.2 RADIATED EMISSION MEASUREMENT 15 4.2.1 RADIATED EMISSION LIMITS 15 4.2.2 TEST PROCEDURE 16 4.2.3 DEVIATION FROM TEST STANDARD 16 4.2.4 TEST SETUP 17 4.2.5 EUT OPERATING CONDITIONS 18 4.2.6 EUT TEST CONDITIONS 18 4.2.7 TEST RESULTS (9KHZ TO 30MHZ) 19 4.2.8 TEST RESULTS (30MHZ TO 1000 MHZ) 19 4.2.9 TEST RESULTS (ABOVE 1000 MHZ) 19 5 . BANDWIDTH TEST 20 5.1 APPLIED PROCEDURES 20 5.1.1 TEST PROCEDURE 20 5.1.2 DEVIATION FROM STANDARD 20 5.1.3 TEST SETUP 20 5.1.4 EUT OPERATION CONDITIONS 20 5.1.5 EUT TEST CONDITIONS 20 5.1.6 TEST RESULTS 20 6 . MAXIMUM PEAK CONDUCTED OUTPUT POWER TEST 21 Report No.: BTL-FCCP-1-1510C002 Page 4 of 121 Table of Contents Page 6.1 APPLIED PROCEDURES / LIMIT 21 6.1.1 TEST PROCEDURE 21 6.1.2 DEVIATION FROM STANDARD 21 6.1.3 TEST SETUP 21 6.1.4 EUT OPERATION CONDITIONS 21 6.1.5 EUT TEST CONDITIONS 21 6.1.6 TEST RESULTS 21 7 . ANTENNA CONDUCTED SPURIOUS EMISSION 22 7.1 APPLIED PROCEDURES / LIMIT 22 7.1.1 TEST PROCEDURE 22 7.1.2 DEVIATION FROM STANDARD 22 7.1.3 TEST SETUP 22 7.1.4 EUT OPERATION CONDITIONS 22 7.1.5 EUT TEST CONDITIONS 22 7.1.6 TEST RESULTS 22 8 . POWER SPECTRAL DENSITY TEST 23 8.1 APPLIED PROCEDURES / LIMIT 23 8.1.1 TEST PROCEDURE 23 8.1.2 DEVIATION FROM STANDARD 23 8.1.3 TEST SETUP 23 8.1.4 EUT OPERATION CONDITIONS 23 8.1.5 EUT TEST CONDITIONS 23 8.1.6 TEST RESULTS 23 9 . MEASUREMENT INSTRUMENTS LIST 24 10 . EUT TEST PHOTO 26 ATTACHMENT A - CONDUCTED EMISSION 30 ATTACHMENT B - RADIATED EMISSION (9KHZ TO 30MHZ) 31 ATTACHMENT C - RADIATED EMISSION (30MHZ TO 1000MHZ) 33 ATTACHMENT D - RADIATED EMISSION (ABOVE 1000MHZ) 40 ATTACHMENT E - BANDWIDTH 89 ATTACHMENT F – MAXIMUM PEAK CONDUCTED OUTPUT POWER 98 ATTACHMENT G - ANTENNA CONDUCTED SPURIOUS EMISSION 100 ATTACHMENT H - POWER SPECTRAL DENSITY 113 Report No.: BTL-FCCP-1-1510C002 Page 5 of 121 REPORT ISSUED HISTORY Issued No. Description Issued Date BTL-FCCP-1-1510C002 Original Issue. Nov. 03, 2015 Report No.: BTL-FCCP-1-1510C002 Page 6 of 121 1. CERTIFICATION Equipment : 3G/4G TRINITY PORTABLE SIM-BASED WI-FI HOTSPOT Brand Name : NEXXT Model Name : ARNPR3G5U1 Applicant : NEXXT SOLUTIONS Manufacturer : NEXXT SOLUTIONS Address : 3505 N.W 107TH AVE,MIAMI,FL,33178 Date of Test : Oct. 08, 2015 ~ Nov. 02, 2015 Test Sample : Engineering Sample Standard(s) : FCC Part15, Subpart C: 2014 (15.247) / ANSI C63.10-2013 The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. BTL-FCCP-1-1510C002) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment standard and technical standard(s). Report No.: BTL-FCCP-1-1510C002 Page 7 of 121 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standard(s): Applied Standard(s): FCC Part15 (15.247) , Subpart C: 2014 Standard(s) Section Test Item Judgment Remark 15.207 Conducted Emission PASS 15.247(d) Antenna conducted Spurious Emission PASS 15.247(a)(2) 6d…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: BTL-FCCP-1-1510C002 Page 26 of 121 10. EUT TEST PHOTO Conducted Measurement Photos Report No.: BTL-FCCP-1-1510C002 Page 27 of 121 Radiated Measurement Photos 9KHz to 30MHz Report No.: BTL-FCCP-1-1510C002 Page 28 of 121 Radiated Measurement Photos 30MHz to 1000MHz Report No.: BTL-FCCP-1-1510C002 Page 29 of 121 Radiated Measurement Photos Above 1000MHz

Test Setup Photos

Report No.: BTL-FCC-SAR-1510C002 Issued Date: Nov. 03, 2015 Appendix D. Photographs of the Test Set-Up Photo 1: Front Face_10mm Photo 2: Rear Face_10mm Photo 3: Left Side_10mm Photo 4: Right Side_10mm Photo 5: Top Side_10mm Photo 6: Bottom Side_10mm

Contact Information

Applicant

Albert Mizrachi(Vice president of product development)
[email protected]786-280-7600Fax: 305 477- 5694

Technical Contact

BTL Inc.Steven Lu
[email protected]86-769-83183000

No.3 Jinshagang 1st Rd, Shixia, Dalang · China

Non-Technical Contact

BTL Inc.Cathy Wang
[email protected]86-769-83183000

Test Firm

BTL Inc.Daisy Dai
[email protected]008676983183000Fax: 0086 769 83196000

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz50.00 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The SAR data in this filing is applicable to demonstrate compliance for body-worn operating conditions and is limited to the specific configuration tested for this filing. End-users must be informed of the body worn requirements to satisfy RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The highest reported SAR values for body and simultaneous transmission use conditions are 0.32 W/kg @10mm and 1.56 W/kg, respectively. Device supports (20/40 MHz) bandwidths mode.

Other Applications from NEXXT SOLUTIONS

Smart Camera - FCC ID X4YHACIF25W - NEXXT SOLUTIONS
X4YHACIF25W

Smart Camera

Aug 06, 2026

Equipment Class

DTS - Digital Transmission System
Smart Camera - FCC ID X4YHACOP40SL - NEXXT SOLUTIONS
X4YHACOP40SL

Smart Camera

Jul 07, 2026

Equipment Class

PCB - PCS Licensed Transmitter
Xmas string lights - FCC ID X4YHABXL20 - NEXXT SOLUTIONS
X4YHABXL20

Xmas string lights

Jan 14, 2026

Equipment Class

DTS - Digital Transmission System
AROMA DIFFUSER - FCC ID X4YHAAD300 - NEXXT SOLUTIONS
X4YHAAD300

AROMA DIFFUSER

Jan 06, 2026

Equipment Class

DTS - Digital Transmission System
Camera - FCC ID X4YHACIP15 - NEXXT SOLUTIONS
X4YHACIP15

Camera

Sep 28, 2025

Equipment Class

DTS - Digital Transmission System