
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
WII REMOTE USER MANUAL Congratulations on your purchase of the WII Remote for Wii™. The contents of this package include: 1 – Remote for Wii™ 1 – User Manual Before using this product, please attach the wrist strap to the end of the Remote. Battery Instructions: Open the battery compartment located on the back of the Remote Insert the 2 AA batteries, ensuring correct polarity (see figure 2) Close the Remote battery compartment (see figure 3) Synchronization: Press the “POWER” button on the top left hand side of the Remote to switch it on Synchronize the Remote with the Wii™ console o Press the “SYNC” button located on the Wii™ console (see figure 4) o Press the “SYNC” button located on the Remote (see figure 5) Standby Mode: The Remote will automatically enter standby mode when not in use for a period of time. To exit standby mode, press any button on the Remote. Troubleshooting Tips: Remote not working: Change the batteries in the Remote Remote may be in standby mode (refer to Standby Mode Instructions) Ensure the Remote is properly synchronized with the Wii™ console Refer to the Wii™ console Instruction Manual for more troubleshooting tips WARNING: We recommend taking fifteen-minute breaks for every hour played. If, at any time, you feel joint pain in your hands, wrists, elbows or elsewhere, stop playing until the symptoms disappear and see your doctor. USE THE WRIST STRAP. Game play can involve rapid or vigorous motion. Please use the wrist strap to prevent losing your grip on the controller and causing damage to the Remote or surrounding objects, or injury to other people. WEAR THE WRIST STRAP WHEN ONE IS PROVIDED. Make sure all players use the wrist strap and that the strap is secure. When sharing a Remote between multiple players, make sure each person uses the wrist strap properly. Wearing the wrist strap will prevent you from accidentally dropping or throwing the Remote during game play, which could damage the Remote or surrounding objects, or cause injury to other people. DO NOT LET GO OF THE CONTROLLER DURING GAME PLAY. Read the Instruction booklet for the game you are playing and follow all game control instructions for correct use of the Remote or accessory controllers. Hold the Remote securely and avoid excessive motion, as it may cause you to let go of the Remote and may break the wrist strap. If your hands become moist, stop and dry your hands. ALLOW ADEQUATE ROOM AROUND YOU DURING GAME PLAY. 1. Stay at least three (3) feet away from the television. 2. As you may move around during game play, make sure objects and other people are out of your range of movement or arm motion to prevent damage or injury. Important Safeguards & Precautions: This unit is for indoor use only Do not expose to dust, direct sunlight, wet weather conditions, high humidity, high temperature Do not expose the unit to splashing, dripping rain or moisture Do not immerse in liquid Do not disassemble Do not use if the equipment is damaged Never carry the unit by the cable For external cleaning, use a soft, clean, cloth only NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. MODIFICATIONS WILL VOID THE USER AUTHORITY TO OPERATE THE EQUIPMENT. CAUTION: Changes or modifications to this equipment not expressly approved by the manufacturer could void the users authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. FCC ID:X5B-PL7607 This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Performance Designed Products, LLC Date: 05-09-2011 BABT TCB Forsyth House, Churchfield Road, Walton-on-Thames, Surrey, KT12 2TD Dear Sir or Madam, We, Name: Performance Designed Products, LLC Address: 14144 Ventura Blvd, Suite 200 Sherman. Oaks, California, United States hereby authorize Name Representative of agent: Ms. Cathy Wang Agent Company name: Neutron Engineering, Inc. Address: No.3 Jinshagang 1st Road, Shixia, Dalang Town, Dongguan, China Tel No.: +86-769-83183000 ext 119 to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. This authorization expires on September 05, 2012. Sincerely, Signature: Company Officer: Tom Roberts Telephone Number: 1-323-234-9911 Email: [email protected]
Performance Designed Products, LLC Date: 05-09-2011 BABT TCB Forsyth House, Churchfield Road, Walton-on-Thames, Surrey, KT12 2TD Confidentiality Request FCC ID: X5B-PL7607 Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, Performance Designed Products, LLC hereby requests permanent confidential treatment of information accompanying this application as outlined below: Schematics Block Diagrams Operation Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying materials will not be made before the date of the Grant for this Application. Yours sincerely, Signature: Company Officer: Tom Roberts Telephone Number: 1-323-234-9911 Email: [email protected]
Neutron Engineering Inc. Project No.: 1108C294 Page 2 of 10 1108C294 1108C294 Neutron Engineering Inc. Project No.: 1108C294 Page 2 of 10 1108C294 1108C294 Neutron Engineering Inc. Project No.: 1108C294 Page 3 of 10 1108C294 1108C294 Neutron Engineering Inc. Project No.: 1108C294 Page 3 of 10 1108C294 1108C294
Neutron Engineering Inc. Project No.: 1108C294 Page 4 of 10 1108C294 1108C294 Neutron Engineering Inc. Project No.: 1108C294 Page 4 of 10 1108C294 1108C294 Neutron Engineering Inc. Project No.: 1108C294 Page 5 of 10 1108C294 1108C294 Neutron Engineering Inc. Project No.: 1108C294 Page 5 of 10 1108C294 1108C294 Neutron Engineering Inc. Project No.: 1108C294 Page 6 of 10 1108C294 1108C294 Neutron Engineering Inc. Project No.: 1108C294 Page 6 of 10 1108C294 1108C294 Neutron Engineering Inc. Project No.: 1108C294 Page 7 of 10 1108C294 1108C294 Neutron Engineering Inc. Project No.: 1108C294 Page 7 of 10 1108C294 1108C294 Neutron Engineering Inc. Project No.: 1108C294 Page 8 of 10 1108C294 1108C294 Neutron Engineering Inc. Project No.: 1108C294 Page 8 of 10 1108C294 1108C294 Neutron Engineering Inc. Project No.: 1108C294 Page 9 of 10 1108C294 1108C294 Neutron Engineering Inc. Project No.: 1108C294 Page 9 of 10 1108C294 1108C294 Neutron Engineering Inc. Project No.: 1108C294 Page 10 of 10 1108C294 1108C294 Neutron Engineering Inc. Project No.: 1108C294 Page 10 of 10 1108C294 1108C294
Neutron Engineering Inc. Report No.: NEI-FCCP-1-1108C294 Page 1 of 60 FCC Radio Test Report FCC ID: X5B-PL7607 This report concerns (check one) : Original Grant Class II Change Issued Date : Sep. 14, 2011 Project No. : 1108C294 Equipment : Wii Remote Model Name : PL-7607 Applicant : Performance Designed Products,LLC Address : 14144 Ventura Blvd. Suite 200, Sherman Oaks, CA 91423 Manufacturer : Performance Designed Products,LLC Address : 14144 Ventura Blvd. Suite 200, Sherman Oaks, CA 91423 Tested by: Neutron Engineering Inc. EMC Laboratory Date of Receipt: Aug. 31, 2011 Date of Test: Aug. 31, 2011 ~ Sep. 13, 2011 Testing Engineer : ( Ivan Cao) Technical Manager : (Leo Hung) Authorized Signatory : (Steven Lu) Neutron Engineering Inc. No.3,Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China. TEL : (0769) 8318-3000 FAX : (0769) 8319-6000 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1108C294 Page 2 of 60 Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutron shall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Neutron Engineering Inc. Report No.: NEI-FCCP-1-1108C294 Page 3 of 60 Table of Contents Page 1 . CERTIFICATION 6 2 . SUMMARY OF TEST RESULTS 7 2.1 TEST FACILITY 8 2.2 MEASUREMENT UNCERTAINTY 8 3 . GENERAL INFORMATION 9 3.1 GENERAL DESCRIPTION OF EUT 9 3.2 DESCRIPTION OF TEST MODES 11 3.3 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 11 3.4 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 12 3.5 DESCRIPTION OF SUPPORT UNITS 13 4 . EMC EMISSION TEST 14 4.1 CONDUCTED EMISSION MEASUREMENT 14 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 14 4.1.2 MEASUREMENT INSTRUMENTS LIST AND SETTING 14 4.1.3 TEST PROCEDURE 15 4.1.4 DEVIATION FROM TEST STANDARD 15 4.1.5 TEST SETUP 15 4.1.6 EUT OPERATING CONDITIONS 15 4.1.7 TEST RESULTS 16 4.2 RADIATED EMISSION MEASUREMENT 17 4.2.1 RADIATED EMISSION LIMITS 17 4.2.2 MEASUREMENT INSTRUMENTS LIST ANS SETTING 18 4.2.3 TEST PROCEDURE 19 4.2.4 DEVIATION FROM TEST STANDARD 19 4.2.5 TEST SETUP 20 4.2.6 EUT OPERATING CONDITIONS 21 4.2.7 TEST RESULTS (BETWEEN30 – 1000 MHZ) 22 4.2.8 TEST RESULTS (ABOVE 1000 MHZ) 24 5 . NUMBER OF HOPPING CHANNEL 36 5.1 APPLIED PROCEDURES / LIMIT 36 5.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 36 5.1.2 TEST PROCEDURE 36 5.1.3 DEVIATION FROM STANDARD 36 5.1.4 TEST SETUP 36 5.1.5 EUT OPERATION CONDITIONS 36 5.1.6 TEST RESULTS 37 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1108C294 Page 4 of 60 Table of Contents Page 6 . AVERAGE TIME OF OCCUPANCY 38 6.1 APPLIED PROCEDURES / LIMIT 38 6.1.1 MEASUREMENT INSTRUMENTS LIST 38 6.1.2 TEST PROCEDURE 38 6.1.3 DEVIATION FROM STANDARD 38 6.1.4 TEST SETUP 39 6.1.5 EUT OPERATION CONDITIONS 39 6.1.6 TEST RESULTS 40 7 . HOPPING CHANNEL SEPARATION MEASUREMENT 46 7.1 APPLIED PROCEDURES / LIMIT 46 7.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 46 7.1.2 TEST PROCEDURE 46 7.1.3 DEVIATION FROM STANDARD 46 7.1.4 TEST SETUP 46 7.1.5 EUT OPERATION CONDITIONS 46 7.1.6 TEST RESULTS 47 8 . BANDWIDTH TEST 49 8.1 APPLIED PROCEDURES / LIMIT 49 8.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 49 8.1.2 TEST PROCEDURE 49 8.1.3 DEVIATION FROM STANDARD 49 8.1.4 TEST SETUP 49 8.1.5 EUT OPERATION CONDITIONS 49 8.1.6 TEST RESULTS 50 9 . PEAK OUTPUT POWER TEST 52 9.1 APPLIED PROCEDURES / LIMIT 52 9.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 52 9.1.2 TEST PROCEDURE 52 9.1.3 DEVIATION FROM STANDARD 52 9.1.4 TEST SETUP 52 9.1.5 EUT OPERATION CONDITIONS 52 9.1.6 TEST RESULTS 53 10 . ANTENNA CONDUCTED SPURIOUS EMISSION 55 10.1 APPLIED PROCEDURES / LIMIT 55 10.1.1 MEASUREMENT INSTRUMENTS LIST AND SETTING 55 10.1.2 TEST PROCEDURE 55 10.1.3 DEVIATION FROM STANDARD 55 10.1.4 TEST SETUP 55 10.1.5 EUT OPERATION CONDITIONS 55 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1108C294 Page 5 of 60 Table of Contents Page 10.1.6 TEST RESULTS 56 11 . EUT TEST PHOTO 59 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1108C294 Page 6 of 60 1. CERTIFICATION E q u i p m e n t : Wii Remote Brand Name : N/A Model Name : PL-7607 A p p l i c a n t : Performance Designed Products,LLC Factory : Performance Designed Products,LLC Address : 14144 Ventura Blvd. Suite 200, Sherman Oaks, CA 91423 Date of Test : Aug. 31, 2011 ~ Sep. 13, 2011 T e s t I t e m : ENGINEERING SAMPLE Standards : FCC Part15, Subpart C(15.247) / ANSI C63.4 : 2003 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FCCP-1-1108C294) were obtained utilizing the test procedures, test instruments, test sites that has been accredited b…
Text truncated - open the document above for the full version.
Neutron Engineering Inc. Report No.: NEI-FCCP-1-1108C294 Page 59 of 60 11. EUT TEST PHOTO Radiated Measurement Photos 30M~1000MHz Neutron Engineering Inc. Report No.: NEI-FCCP-1-1108C294 Page 59 of 60 11. EUT TEST PHOTO Radiated Measurement Photos 30M~1000MHz Neutron Engineering Inc. Report No.: NEI-FCCP-1-1108C294 Page 60 of 60 Radiated Measurement Photos Above 1000MHz Neutron Engineering Inc. Report No.: NEI-FCCP-1-1108C294 Page 60 of 60 Radiated Measurement Photos Above 1000MHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 560.00 µW |
PDP REALMz Wireless Controller for Xbox
Equipment Class
DTS - Digital Transmission SystemPDP REALMz Wireless Dongle for Xbox
Equipment Class
DTS - Digital Transmission SystemRematch Wireless Controller for Nintendo Switch
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterWireless Controller for Nintendo Switch
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterPhantom Air Wireless Headset for Xbox / Phantom Air Wireless Headset for Play Station
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter