Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1 KW9009CA(2) WEATHER STATION (RC-NONE) USER MANUAL 1. Features 1.1 Weather Forecast - Sunny, Slightly Cloudy, Cloudy, Rainy and Snow animation 1.2 Time - Dual Time setting - 12/24 hour user selectable - Daily Snooze Alarm function - Perpetual Calendar Up to Year 2099 - Day of week in 8 languages user selectable 1.3 Humidity - Measurable range: 20 ~ 99% - Max/Min Memory 1.4 Temperature - Indoor measurable range: 0 ~ 50°C [+32 ~ +122°F] - Measures °C / °F user selectable - Outdoor measurable range: -20 ~ 50°C [-4 ~ +122°F] - Max/Min Memory [indoor & outdoor] - Comfort Indicator Bar 1.5 Wireless Outdoor Sensor - Low-battery indicator for Outdoor Thermo Sensor - Wall Mount or Table Stand - One Wireless Thermo Sensor Included - 433MHz RF transmitting frequency - 30 meter [98 feet] transmission range in an open area 2 2. Main Unit Appearance 2.1 Part A- LCD A1: Outdoor Temperature Trend A2: Air Pressure Trend A3: Outdoor Temperature A4: Weather Forecast A5: Indoor Temperature A6: Indoor Humidity A7: Comfort Indicator Bar A8: Time A9: Moon Phase A10: Date, Day of Week 2.2 Part B- Buttons B1: “ALARM” button B2: “+ (12/24)” button B3: “SNOOZE/LIGHT” button B4: “-(C/F)” button B5: “MODE” button B6: “RESET” button B7: “MAX/MIN” button B8: “WEATHER” button B9: “CHANNEL” button 2.3 Part C- Structure C1: Wall Mount Hole C2: Battery Cover C3: Stand 3 3. Outdoor Thermo Sensor D1: Transmission Indication LED D2: Wall Mount Hole D3: Battery Compartment D4: “RESET” button D5: Channel Select Switch D6: Stand 4.Getting Started: 4.1 Main Unit: z Open main unit battery compartment cover [C2] z Insert 2 x AA batteries observing polarity [ “+” and“ –“ marks] z Replace main unit battery compartment cover [C2] z Use a pin to press the RESET [B6] button on the rear of the main unit, the main unit is now ready for use 4.2 Outdoor Thermo Sensor z Batteries compartment (D3) of thermo sensor is locating behind the back cover, unscrews the batteries cover to open. z Insert 2 x AAA batteries observing polarity [ “+” and “–“ marks] 4 5. Installation 5.1 Main Unit The main unit can be placed onto any flat surface (C3), or wall mounted by the hanging hole (C1) at the back of the unit. 5.2 Outdoor Thermo sensor The remote sensor should be securely mounted onto a horizontal surface. Note: Transmissions between receiver and transmitter can reach up to 30m in open area. Open Area: there are no interfering obstacles such as buildings, trees, vehicles, high voltage lines, etc. 6. Weather Forecast Function 6.1 Operation z After Batteries inserted, OR holding “WEATHER” button (B8) for 3 seconds, weather icon flash (A4) on the LCD. Enter the current weather pressing “-” (B4) or “+ “(B2) button. Press “WEATHER” (B8) button to confirm the setting. The weather forecast may not be accurate if the current weather entered is not correct. z The current weather status should be entered again if the altitude of the Main Unit is changed. (Barometric pressure is lower at higher altitude location. Therefore, altitude change will affect the weather forecast). The weather station will start the first forecast at 6 hours later after the current weather status is entered. 6.2 Weather Conditions There are totally 5 different weather status animations in the weather forecast. Sunny Slightly Cloudy Cloudy Rain Freezing or Snow 5 Note: z “ “ is shown if the weather forecast is Rainy and outdoor temperature (any channel) under 0°C. z Frost Alert: “” is shown if the outdoor temperature (any channel) is between -2°C ~ +3 °C z If there is any inconsistency of weather forecast between Local Weather Station and this unit, the Local Weather Station's forecast should prevail. The manufacture will not hold responsible for any trouble that may come up due to wrong forecasting from this unit. 6.3 Barometric Trend Pointer (A2) The trend pointer displayed on the LCD (A2) indicates the trend of the Barometric pressure. Indicating the barometric pressure trend is rising Indicating the barometric pressure trend is steady Indicating the barometric pressure trend is falling 7. Thermometer 7.1 RF Transmission Procedure: z The main unit automatically starts receiving transmission from outdoor thermo sensor for outdoor temperature after weather condition setting. z The thermo sensor unit will automatically transmit temperature signal to the main unit after batteries inserted. z For having more than one external transmitter (Maximum3), select the Channel, CH1, CH2 or CH3 to ensure each sensor is transmitting difference channel before inserting batteries. The channel select switch (D5) is at the back of the thermo sensor. z If main unit failed to receive transmission from outdoor thermo sensor in first 3 minutes after the batteries inserted (“- - . –”display on the LCD), hold “Channel” button (B9) for 3 seconds to receive transmission manually. RF icon “ ” flashes on the LCD Note: Buttons (except “Channel”&“Light” buttons) will not function while Freezing or Snow 6 scanning for thermo sensor’s signal unless they are well received or stopped manually. 7.2 Temperature& Humidity (1) Outdoor Temperature--- Channel Selection z Press “CHANNEL” button (B9) to view the 3 Channel’s temperature. The sequence is shown as follow: PRESS “CHANNEL” button PRESS “CHANNEL” button PRESS “CHANNEL” button display the three channels alternatively z When viewing the record on CHANNEL 1 or 2, or 3, hold “CHANNEL” button (B9) for 3 seconds to cancel the record on this channel manually, and receive the transmission from channels automatically again. (2) Outdoor Temperature Trend z The trend pointer (A1) displayed on the LCD indicates the trend of the outdoor temperature. Indicating the outdoor temp. is rising Indicating the outdoor temp. is steady Indicating the outdoor temp. is falling (3)Celsius / Fahrenheit z Press “°C /°F” button (B4) to select Indoor/Outdoor Temperature in Celsius mode or Fahrenheit mode. z If the temperature is out of the measurable range, LL.L (beyond the minimum temperature…
Text truncated - open the document above for the full version.
CARRIN ELECTRONICS COMPANY LIMITED DATE : 2011-12-12 Nemko Canada Inc 303 River Road Ottawa, Ontario, Canada K1V 1H2 Attn: Director of Certification Authority to Act as Agent On our behalf, I appoint __ Global United Technology Service Co., Ltd. 2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District Shenzhen Guangdong __ (Name and address,person). to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditionsfor certification, as specified by Nemko Canada Inc, still resides with CARRIN ELECTRONICS COMPANY LIMITED UNIT 2105-2106, TOWER A, REGENT CENTRE, 63 WO YI HOP RD, KWAI CHUNG, HONGKONG _( applicant name and address). Dated this Day of 12/12/2011 20 Agency agreement expiration date: Usually Give 8 - 12 Months By: Sam Li Signature Printed Title: Manager On behalf of : CARRIN ELECTRONICS COMPANY LIMITED Telephone: (852) 2418 2262
Report No: GTSE11110093702 Global United Technology Services Co., Ltd. Project No.: GTSE111100937RF 2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District, Shenzhen, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 15 of 19 9 EUT Constructional Details Report No: GTSE11110093702 Global United Technology Services Co., Ltd. Project No.: GTSE111100937RF 2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District, Shenzhen, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 16 of 19
Label location 1 Label location 2
Report No: GTSE11110093702 Global United Technology Services Co., Ltd. Project No.: GTSE111100937RF 2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District, Shenzhen, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 17 of 19 Report No: GTSE11110093702 Global United Technology Services Co., Ltd. Project No.: GTSE111100937RF 2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District, Shenzhen, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 18 of 19 Report No: GTSE11110093702 Global United Technology Services Co., Ltd. Project No.: GTSE111100937RF 2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District, Shenzhen, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 19 of 19 ------End ------
Global United Technology Services Co., Ltd. Report No: GTSE11110093702 Authorized Signature: Stephen Guo Laboratory Manager This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the GTS product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. Any mention of GTS International Electrical Approvals or testing done by GTS International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by GTS International Electrical Approvals in writing. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.” 1 Cover Page TEST REPORT Applicant: CARRIN ELECTRONICS COMPANY LIMITED Address of Applicant: UNIT 2105~2106, TOWER A, REGENT CENTRE, 63 WO YI HOP RD, KWAI CHUNG, HONG KONG Equipment Under Test (EUT) Product Name: WEATHER STATION Model No.: KW9009, 47021RX FCC ID: X6I-9009 Applicable standards: FCC CFR Title 47 Part 15 Subpart B:2010 Date of sample receipt: Nov. 21, 2011 Date of Test: Nov. 21-23, 2011 Date of report issued: Nov. 24, 2011 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No: GTSE11110093702 Global United Technology Services Co., Ltd. Project No.: GTSE111100937RF 2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District, Shenzhen, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 19 2 Version Version No. Date Description 00 Nov. 24, 2011 Original Prepared by: Date: Nov. 24, 2011 Project Engineer Reviewed by: Date: Nov. 24, 2011 Reviewer Report No: GTSE11110093702 Global United Technology Services Co., Ltd. Project No.: GTSE111100937RF 2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District, Shenzhen, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 19 3 Contents Page 1 COVER PAGE.........................................................................................................................................................1 2 VERSION..................................................................................................................................................................2 3 CONTENTS..............................................................................................................................................................3 4 TEST SUMMARY....................................................................................................................................................4 5 GENERAL INFORMATION...................................................................................................................................5 5.1 CLIENT INFORMATION....................................................................................................................................... 5 5.2 GENERAL DESCRIPTION OF E.U.T................................................................................................................... 5 5.3 TEST MODE AND VOLTAGE...............................................................................................................................5 5.4 TEST FACILITY................................................................................................................................................... 5 5.5 TEST LOCATION................................................................................................................................................ 6 5.6 DESCRIPTION OF SUPPORT UNITS................................................................................................................... 6 5.7 DEVIATION FROM STANDARDS.......................................................................................................................... 6 5.8 ABNORMALITIES FROM STANDARD CONDITIONS.............................................................................................. 6 5.9 OTHER INFORMATION REQUESTED BY THE CUSTOMER.................................................................................. 6 6 TEST INSTRUMENTS LIST..................................................................................................................................7 7 TEST RESULTS AND MEASUREMENT DATA................................................................................................8 7.1 RADIATED EMISSION......................................................................................................................................... 8 8 TEST SETUP PHOTO..........................................................................................................................................14 9 EUT CONSTRUCTIONAL DETAILS.................................................................................................................15 Report No: GTSE11110093702 Global United Technology Services Co., Ltd. Project No.: GTSE111100937RF 2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District, Shenzhen, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 19 4 Test Summary Test Item Section in CFR 47 Result Conducted Emission Part15.107 N/A Radiat…
Text truncated - open the document above for the full version.
Report No: GTSE11110093702 Global United Technology Services Co., Ltd. Project No.: GTSE111100937RF 2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District, Shenzhen, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 14 of 19 8 Test Setup Photo Radiated Emission(below 1G) Radiated Emission(above 1G)
2nd Floor, Block No.2, Laodong Industrial Zone, · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 433.96 MHz - 433.96 MHz | - |

THERMO SENSOR
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
THERMO SENSOR
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
WEATHER STATION
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
WEATHER STATION
Equipment Class
CRR - Superregenerative Receiver
WEATHER STATION
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter