
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC ID : X6VMTMCM4000MSP HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1003FR16 1/1 ATTACHMENT E. - USER MANUAL - MTM-CM4000MSP are wireless sensor network moduleWe can monitor environmental information by using temperature/humidity/tilt/lumi nous intensity/air quality/ water quality/... sensor applied MTM seriesMTM series in local area sense the environmental information and transmit the information to the base station Base station is composed of MTM series and monitoring tool like as P.C MTM series in Base station is conn ected to P.C by using serial cable like as USB cable MTM series use the wireless communication among MTM series The major application field of MTM series are agriculture,construction, safety, security Application Manual Application Manual Th is equipment has been tested and found to comply with the limi ts for a Cl ass B digital device, pursuant to part 15 of the FCC Rules. Thes e limits are designed to provide reasonable protection against harmful interference in a residential installation. This equ ipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by tu rning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modi fi cations to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may n ot cause harmful interference, and (2) this device must accept any interference received, including interference that may cause un desired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum 20 cm between the radiator and your body. This transmitter must not be collocated or operating in conjunction with any other antenna or transmitter unless authorized to do so by the FCC.
SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 2.0 2206 Ringwood Avenue San Jose, CA 95131 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (current) 1.0 1.0 Nov-14-2006 Revised wording (current) 1.0 2.0 Sept–25-2007 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 2.0 MAXFOR Technology Inc. March 22, 2010 To: SIEMIC, INC. 2206 Ringwood Avenue, San Jose, CA 95131 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, MAXFOR Technology Inc. hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): Network module , MTM-CM4000MSP (FCC ID : X6VMTMCM4000MSP) We affirm that between SIEMIC and MAXFOR Technology Inc. any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Applicant’s Company :MAXFOR Technology Inc. Address :#E 809, Bundang, Techno-Park, 151, Yatap-Dong, Bundang-Gu, Seongnam-City, Gyeonggi-Do, 463-760 Korea
SCS-F19: Confidentiality Request Letter Rev 1.0 Nov 14, 2006 Confidentiality Request Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (current) 1.0 1.0 Nov-14-2006 SCS-F19: Confidentiality Request Letter Rev 1.0 Nov 14, 2006 MAXFOR Technology Inc. To: Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID X6VMTMCM4000MSP We hereby request confidential treatment of information accompanying this application as outlined below: COMNFIDENTIAL AND SHORT-TERM CONFIDENTIAL LIST Exhibit Description 1 Block Diagram 2 Schematics 3 Operational Description 4 CONFIDENTIAL 5 Internal Photos 6 External Photos 7 Test-Setup Photos SHORT-TERM CONFIDENTIAL 8 User’s Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Applicant’s Company : MAXFOR Technology Inc. Address :#E 809, Bundang, Techno-Park, 151, Yatap-Dong, Bundang-Gu, Seongnam-Si, Gyeonggi-Do Korea Job Title and Dept: JungDuk Choi
March 22, 2010 (Network Module Model MTM-CM4000MSP) FCC ID : X6VMTMCM4000MSP , is seeking FCC Authorization as a Limited modular transmitter. The EUT meets the requirements for modular approval as detailed in F CC public Notice DA00-1407. Compliance to each of the requirements is described below: Questions are: 1. “The modular transmitter must have its own RF shielding.” Does not comply 2. “The modular transmitter must have buffered modulation/data inputs.” Complies 3. “The modular transmitter must have its own power supply regulation.” Has 3.3V regulated supply 4. “The modular transmitter must comply with the antenna requirements of section 15.203 and 15.204(c).” Complies 5. “The modular transmitter must be tested in a stand-alone configuration.” Complies 6. “The modular transmitter must be labeled with its own FCC ID number.” X6VMTMCM4000MSP 7. “The modular transmitter must comply with any specific rule or operating requirements applicable to the transmitter and the manufacture must provide adequate instruction along with the module to explain any such requirements.” Complies 8. “The modular transmitter must comply with any applicable RF exposure requirements.” Complies 0.00182 mW output, -2.31dBi antenna gain Applicant’s Company :MAXFOR Technology Inc. Address :#E 809, Bundang, Techno-Park, 151, Yatap-Dong, Bundang-Gu, Seongnam-City, Gyeonggi-Do, 463-760 Korea
FCC ID : X6VMTMCM4000MSP HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1003FR16 1/7 ATTACHMENT B. -EXTERNAL PHOTOS - FCC ID : X6VMTMCM4000MSP HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1003FR16 2/7 FCC ID : X6VMTMCM4000MSP HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1003FR16 3/7 FCC ID : X6VMTMCM4000MSP HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1003FR16 4/7 FCC ID : X6VMTMCM4000MSP HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1003FR16 5/7 FCC ID : X6VMTMCM4000MSP HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1003FR16 6/7 FCC ID : X6VMTMCM4000MSP HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1003FR16 7/7
FCC ID :X6VMTMCM4000MSP HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1003FR16 1/3 ATTACHMENT A. - ID LABEL INFORMATION AND LOCATION PHOTOS - FCC ID :X6VMTMCM4000MSP HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1003FR16 2/3 1.1 ID Label Information Following is a copy of the label that will be placed on the rear side of the cabinet. Both the FCC ID and compliance statement are included in the product label Figure 1.1 PRODUCT LABEL Model No : MTM-CM4000MSP FCC ID : X6VMTMCM4000MSP EUT Type : network module Serial No : This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions : (1) this device may not cause harmful interference , and (2) this device must accept any interference received, Includin g interference that may cause undesired operation. MAXFOR Technology Inc. #E 809, Bundang, Techno-Park, 151, Yatap-Dong, Bundang-Gu, Seongnam-City, Gyeonggi-Do, 463-760 Korea MADE IN KOREA FCC ID :X6VMTMCM4000MSP HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1003FR16 3/3 1.2 Label Location Photos The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase.(Labeling requirements per 2.925) Figure 1.2 LABEL LOCATION LABEL
FCC ID: X6VMTMCM4000MSP HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1003FR16 1/3 ATTACHMENT F. - INTERNAL PHOTOS - FCC ID: X6VMTMCM4000MSP HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1003FR16 2/3 FCC ID: X6VMTMCM4000MSP HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1003FR16 3/3
HCTGPT.15.247 TEST REPORT FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1003FR16 Date of Issue: March 19, 2010 EUT Type: network module FCC ID: X6VMTMCM4000MSP Page୍ of 32 7.5 MAXIMUM PERMISSIBLE EXPOSURE 1. LIMITS hGG§XUXZXWGG§YUXW`XGymGGGUG (B) Limits for General Population/Uncontrolled Exposures Frequency range (MHz) Electric field Strength (V/m) Magnetic field Strength (A/m) Power density (mW/cm²) Averaging time (minutes) 0.3 - 1.34....................................... 1.34 - 30....................................... 30 - 300....................................... 300 - 1500.................................... 1500 - 100.000................................. 614 824/f 27.5 ............... ............... 1.63 2.19/f 0.073 ............... ............... *(100) *(180/ f²) 0.2 f/1500 1.0 30 30 30 30 30 F = frequency in MHz * = Plane-wave equivalent power density 2. MAXIMUM PERMISSIBLE EXPOSURE Prediction Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 zGdGwnV[ʌy²G S = Power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna HCTGPT.15.247 TEST REPORT FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1003FR16 Date of Issue: March 19, 2010 EUT Type: network module FCC ID: X6VMTMCM4000MSP Page of 32 ;ΒΩ͑ΖΒΜ͑ΠΦΥΡΦΥ͑ΠΨΖΣ͑ΒΥ͑ΒΟΥΖΟΟΒ͑ΚΟΡΦΥ͑ΥΖΣΞΚΟΒΝ͑ͣͧ͑͑͟͡͡͡͡ ΕͳΞ͑ ;ΒΩ͑ΖΒΜ͑ΠΦΥΡΦΥ͑ΠΨΖΣ͑ΒΥ͑ΒΟΥΖΟΟΒ͑ΚΟΡΦΥ͑ΥΖΣΞΚΟΒΝ͑ͩͪͨ͑͑͢͟͢͡ ΞΈ͑ ΣΖΕΚΔΥΚΠΟ͑ΕΚΤΥΒΟΔΖ͑ͣ͑͑͟͡͡͡͡͡͡ ΔΞ͑ ΣΖΕΚΔΥΚΠΟ͑ΗΣΖΦΖΟΔΪ͑ͣͥͩ͑͑͟͡͡͡͡͡͡ ;Ϋ͑ ͲΟΥΖΟΟΒ͑ΒΚΟ͙ΥΪΡΚΔΒΝ͚͑ͣͤ͑͑͟͢͞͡͡͡ ΕͳΚ͑ ͲΟΥΖΟΟΒ͑ΒΚΟ͙ΟΦΞΖΣΚΔ͚͑ͦͩͨͥͪ͑͑͟͡ ͑͞ ΠΨΖΣ͑ΕΖΟΤΚΥΪ͑ΒΥ͑ΡΣΖΕΚΔΥΚΠΟ͑ΗΣΖΦΖΟΔΪ͙͑ ͚́͑ͣ͑͑͟͢͡͡͡͡ ΞΈ͠ΔΞ ͣ ͑ ;Ͷ͑ΝΚΞΚΥ͑ΗΠΣ͑ΦΟΔΠΟΥΣΠΝΝΖΕ͑ΖΩΡΠΤΦΣΖ͑ΒΥ͑ΡΣΖΕΚΔΥΚΠΟ͑ΗΣΖΦΖΟΔΪ͑ ͑͑͢͟͡͡͡͡͡ ΞΈ͠ΔΞ ͣ ͑ 3. RESULTS The power density level at 20 cm is 0.00021 mW/cm², which is below the uncontrolled exposure limit of 1.0 mW/cm² at 2480 MHz
HCTGPT.15.247 TEST REPORT FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1003FR16 Date of Issue: March 19, 2010 EUT Type: network module FCC ID: X6VMTMCM4000MSP Page of 32 Table of Contents 1. GENERAL INFORMATION....................................................................................................................... 2. EUT DESCRIPTION ..................................................................................................................................... 3. TEST METHODOLOGY ............................................................................................................................... 3.1 EUT CONFIGURATION....................................................................................................................... 3.2 EUT EXERCISE ................................................................................................................................... 3.3 GENERAL TEST PROCEDURES ....................................................................................................... 3.4 DESCRIPTION OF TEST MODES ...................................................................................................... 4. INSTRUMENT CALIBRATION..................................................................................................................... 5. FACILITIES AND ACCREDITATIONS ......................................................................................................... 5.1 FACILITIES.......................................................................................................................................... 5.2 EQUIPMENT ........................................................................................................................................ 6. ANTENNA REQUIREMENTS ...................................................................................................................... 7. TEST RESULT ............................................................................................................................................. 7.1 6dB Bandwidth Measurement........................................................................................................... 7.2 Output Power Measurement .........................................................................................................୍ୌ 7.3 Power Spectral Density .................................................................................................................୍ 7.4 Out of Band Emissions at the Band Edge/ Conducted Spurious Emissions ..........................୍ 7.5 MAXIMUM PERMISSIBLE EXPOSURE .........................................................................................୍ 7.6 Radiated Measurement.................................................................................................................. 7.6.1 Radiated Spurious Emissions................................................................................................ 7.6.2 Radiated Restricted Band Edge Measurements .................................................................. ୍ 8. LIST OF TEST EQUIPMENT ................................................................................................................... G G G G G G HCTGPT.15.247 TEST REPORT FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1003FR16 Date of Issue: March 19, 2010 EUT Type: network module FCC ID: X6VMTMCM4000MSP Page of 32 1. GENERAL INFORMATION G Applicant: MAXFOR Technology Inc. Address: #E 809, Bundang, Techno-Park, 151, Yatap-Dong, Bundang-Gu, Seongnam-City, Gyeonggi-Do, 463-760, Korea FCC ID: X6VMTMCM4000MSP EUT: network module Model: MTM-CM4000MSP Date of Test: January 25, 2010 Contact person: Name: Joong Deok Choi Phone #: TEL :+82-31-601-3533 / FAX : +82-31-705-4653 G 2. EUT DESCRIPTION Product network module Model Name MTM-CM4000MSP Power Supply DC 3.3 V Frequency Range 2405 ~ 2480 MHz (DSSS) Max. RF Output Power 2.60 dBm(1.82 mW) Modulation Type DSSS Antenna Specification Manufacturer: MAXFOR Technology Inc. Antenna type: PCB Antenna Peak Gain : -2.31 dBi HCTGPT.15.247 TEST REPORT FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1003FR16 Date of Issue: March 19, 2010 EUT Type: network module FCC ID: X6VMTMCM4000MSP Page of 32 3. TEST METHODOLOGY The measurement procedure described in the American National Standard for Methods of Measurement of Radio-Noise Emission from Low-Voltage Electrical and Electronic Equipment in the Range of 9kHz to 40GHz(ANSI C63.4-2003) 3.1 EUT CONFIGURATION The EUT configuration for testing is installed on RF field strength measurement to meet the Commissions requirement and operating in a manner that intends to maximize its emission characteristics in a continuous normal application. 3.2 EUT EXERCISE The EUT was operated in the engineering mode to fix the Tx frequency that was for the purpose of the measurements. According to its specifications, the EUT must comply with the requirements of the Section 15.207, 15.209 and 15.247 under the FCC Rules Part 15 Subpart C. 3.3 GENERAL TEST PROCEDURES Conducted Emissions The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the requirements in Section 13.1.4.1 of ANSI C63.4. (Version :2003) Conducted emissions from the EUT measured in the frequency range between 0.15 MHz and 30MHz using CISPR Quasi-peak and average detector modes. Radiated Emissions The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall rotate 360 degrees to determine the position of maximum emission level. EUT is set 3 m away from the receiving antenna, which varied from 1 m to 4 m to find out the highest emission. And also, each emission was to be maximized by changing the polarization of receiving antenna both horizontal and vertical. In order to find out the max. emission, the relative positions of this hand-held transmitter (EUT) was rotated through three orthogonal axes …
Text truncated - open the document above for the full version.
FCC ID : X6VMTMCM4000MSP HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1003FR16 1/4 ATTACHMENT D. - SETUP PHOTO - FCC ID : X6VMTMCM4000MSP HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1003FR16 2/4 ( Open Site Test Setup) FCC ID : X6VMTMCM4000MSP HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1003FR16 3/4 FCC ID : X6VMTMCM4000MSP HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1003FR16 4/4
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.82 mW |

Smart Gateway
Equipment Class
DTS - Digital Transmission System
Smart Gateway
Equipment Class
DTS - Digital Transmission System
Indoor Air Quality Monitor
Equipment Class
DTS - Digital Transmission System
Network Module
Equipment Class
DTS - Digital Transmission System
Wireless Sensor Network Module
Equipment Class
DTS - Digital Transmission System