Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 01, 2011
Application Purpose
Original Equipment
Date of Application
Aug 01, 2011
Equipment Note
Network Module
Frequency Range
906.00000000 - 924.00000000
Company
MAXFOR Technology Inc.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

This equipment has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to Part 15 of the FCC Rules. These limits aredesigned to provide reasonable protection against harmful interference in aresidential installation.This equipment generates, uses and can radiate radiofrequency energy and, if not installed and used in accordance with the instructions,may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on,the user isencouraged to try to correct the interference by one or more of the following• Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modi f cations to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may n ot cause harmful interference, and (2) this device must accept any interference received, including interference that may cause un desired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum 20 cm between the radiator and your body. This transmitter must not be collocated or operating in conjunction with any other antenna or transmitter unless authorized to do so by the FCC. Notice it does not use the usb port. This usb port is unfit for use in computer. A PC network connection to the usb port could not be established.

Cover Letter(s)

2206 Ringwood Avenue San Jose, CA 95131 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (current) 1.0 1.0 Nov-14-2006 Revised wording (current) 1.0 2.0 Sept–25-2007 SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 2.0 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 2.0 MAXFOR Technology Inc. July 27, 2011 To: SIEMIC, INC. 2206 Ringwood Avenue, San Jose, CA 95131 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, MAXFOR Technology Inc. hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): Network module , MTM-CM900ATL We affirm that between SIEMIC and MAXFOR Technology Inc.. any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Applicant’s Company :MAXFOR Technology Inc. Address :#E 809, Bundang, Techno-Park, 151, Yatap-Dong, Bundang-Gu, Seongnam-City, Gyeonggi-Do, 463-760 Korea FCC ID: X6VMTMCM900ATL

Cover Letter(s)

Confidentiality Request Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (current) 1.0 1.0 Nov-14-2006 SCS-F19: Confidentiality Request Letter Rev 1.0 Nov 14, 2006 SCS-F19: Confidentiality Request Letter Rev 1.0 Nov 14, 2006 MAXFOR Technology Inc. To: Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID X6VMTMCM900ATL We hereby request confidential treatment of information accompanying this application as outlined below: COMNFIDENTIAL AND SHORT-TERM CONFIDENTIAL LIST Exhibit Description 1 Block Diagram 2 Schematics CONFIDENTIAL 3 Operational Description 4 Internal Photos 5 External Photos 6 Test-Setup Photos SHORT-TERM CONFIDENTIAL 7 User’s Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Applicant’s Company : MAXFOR Technology Inc. Address :#E 809, Bundang, Techno-Park, 151, Yatap-Dong, Bundang-Gu, Seongnam-Si, Gyeonggi-Do Korea Job Title and Dept: JungDuk Choi

Cover Letter(s)

July 27, 2011 (network module Model MTM-CM900ATL) FCC ID : X6VMTMCM900ATL , is seeking FCC Authorization as a modular transmitter. The EUT meets the requirements for Limited modular approval as detailed in FCC public Notice DA00-1407. Compliance to each of the requirements is described below: Questions are: 1. “The modular transmitter must have its own RF shielding.” No. 2. “The modular transmitter must have buffered modulation/data inputs.” Yes. 3. “The modular transmitter must have its own power supply regulation.” Yes. 4. “The modular transmitter must comply with the antenna requirements of section 15.203 and 15.204(c).” Yes. 5. “The modular transmitter must be tested in a stand-alone configuration.” Yes 6. “The modular transmitter must be labeled with its own FCC ID number.” Yes X6VMTMCM900ATL 7. “The modular transmitter must comply with any specific rule or operating requirements applicable to the transmitter and the manufacture must provide adequate instruction along with the module to explain any such requirements.” Yes. 8. “The modular transmitter must comply with any applicable RF exposure requirements.” Yes. Applicant’s Company : MAXFOR Technology Inc. Address :#E 809, Bundang, Techno-Park, 151, Yatap-Dong, Bundang-Gu, Seongnam-Si, Gyeonggi-Do Korea Job Title and Dept: JungDuk Choi

External Photos

FCC ID : X6VMTMCM900ATL HCT CO., LTD. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1107FR28 1/5 ATTACHMENT B. -EXTERNAL PHOTOS - FCC ID : X6VMTMCM900ATL HCT CO., LTD. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1107FR28 2/5 FCC ID : X6VMTMCM900ATL HCT CO., LTD. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1107FR28 3/5 FCC ID : X6VMTMCM900ATL HCT CO., LTD. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1107FR28 4/5 FCC ID : X6VMTMCM900ATL HCT CO., LTD. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1107FR28 5/5

ID Label/Location Info

FCC ID :X6VMTMCM900ATL HCT CO., LTD. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1107FR28 1/3 ATTACHMENT A. - ID LABEL INFORMATION AND LOCATION PHOTOS - FCC ID :X6VMTMCM900ATL HCT CO., LTD. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1107FR28 2/3 1.1 ID Label Information Following is a copy of the label that will be placed on the rear side of the cabinet. Both the FCC ID and compliance statement are included in the product label Figure 1.1 PRODUCT LABEL Model No : MTM-CM900ATL FCC ID : X6VMTMCM900ATL EUT Type : network module Serial No : MAXFOR Technology Inc. #E 809, Bundang, Techno-Park, 151, Yatap-Dong, Bundang-Gu, Seongnam-City, Gyeonggi-Do, 463-760 Korea MADE IN KOREA FCC ID :X6VMTMCM900ATL HCT CO., LTD. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1107FR28 3/3 1.2 Label Location Photos The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase.(Labeling requirements per 2.925) Figure 1.2 LABEL LOCATION LABEL

Internal Photos

FCC ID: X6VMTMCM900ATL HCT CO., LTD. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1107FR28 1/3 ATTACHMENT F. - INTERNAL PHOTOS - FCC ID: X6VMTMCM900ATL HCT CO., LTD. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1107FR28 2/3 FCC ID: X6VMTMCM900ATL HCT CO., LTD. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1107FR28 3/3

RF Exposure Info

FCC ID:X6VMTMCM900ATL HCT CO., LTD 1 of 2 RF Exposure Statement 1. LIMITS According to §1.1310 and §2.1091 RF exposure is calculated. (B) Limits for General Population/Uncontrolled Exposures Frequency range (MHz) Electric field Strength (V/m) Magnetic field Strength (A/m) Power density (mW/cm²) Averaging time (minutes) 0.3 - 1.34....................................... 1.34 - 30....................................... 30 - 300....................................... 300 - 1500.................................... 1500 - 100.000................................. 614 824/f 27.5 ............... ............... 1.63 2.19/f 0.073 ............... ............... *(100) *(180/ f²) 0.2 f/1500 1.0 30 30 30 30 30 F = frequency in MHz * = Plane-wave equivalent power density 2. MAXIMUM PERMISSIBLE EXPOSURE Prediction Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S = PG/4πR² S = Power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna FCC ID: X6VMTMCM900ATL HCT CO., LTD 2 of 2 2-1. Max Peak output Power at antenna input terminal (dBm) -14.660 Max Peak output Power at antenna input terminal (mW) 0.034 Prediction distance (cm) 20.000 Prediction frequency (MHz) 906.000 Antenna Gain(typical) (dBi) 3.000 Antenna Gain(numeric) 1.995 Power density at prediction frequency (mW/cm²) 0.00001 MPE limit for uncontrolled exposure at prediction frequency (mW/cm²) 0.604 3. RESULTS The power density level at 20 cm is 0.00001 mW/cm², which is below the uncontrolled exposure limit of 0.604 mW/cm² at 848.31 MHz

Test Report

FCC PT.15.247 TEST REPORT FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1107FR28 Date of Issue: July 27, 2011 EUT Type: Network Module FCC ID: X6VMTMCM900ATL Page 2 of 33 Version TEST REPORT NO. DATE DESCRIPTION HCTR1107FR28 July 27, 2011 - First Approval Report FCC PT.15.247 TEST REPORT FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1107FR28 Date of Issue: July 27, 2011 EUT Type: Network Module FCC ID: X6VMTMCM900ATL Page 3 of 33 Table of Contents 1. GENERAL INFORMATION..........................................................................................................................4 2. EUT DESCRIPTION.....................................................................................................................................4 3. TEST METHODOLOGY...............................................................................................................................5 3.1 EUT CONFIGURATION......................................................................................................................5 3.2 EUT EXERCISE..................................................................................................................................5 3.3 GENERAL TEST PROCEDURES......................................................................................................5 3.4 DESCRIPTION OF TEST MODES.....................................................................................................5 4. INSTRUMENT CALIBRATION.....................................................................................................................6 5. FACILITIES AND ACCREDITATIONS.........................................................................................................6 5.1 FACILITIES.........................................................................................................................................6 5.2 EQUIPMENT.......................................................................................................................................6 6. ANTENNA REQUIREMENTS......................................................................................................................7 7. TEST RESULT.............................................................................................................................................8 7.1 6dB BANDWIDTH MEASUREMENT.................................................................................................8 7.2 OUTPUT POWER MEASUREMENT..............................................................................................11 7.3 POWER SPECTRAL DENSITY......................................................................................................15 7.4 OUT OF BAND EMISSIONS AT THE BAND EDGE/ CONDUCTE D SPURIOUS EMISSIONS...18 7.5 RADIATED MEASUREMENT.........................................................................................................24 7.5.1 RADIATED SPURIOUS EMISSIONS...................................................................................24 7.6 POWERLINE CONDUCTED EMISSIONS.....................................................................................32 8. LIST OF TEST EQUIPMENT...................................................................................................................33 FCC PT.15.247 TEST REPORT FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1107FR28 Date of Issue: July 27, 2011 EUT Type: Network Module FCC ID: X6VMTMCM900ATL Page 4 of 33 1. GENERAL INFORMATION Applicant: MAXFOR Technology Inc. Address: #E 809, Bundang, Techno-Park, 151, Yatap-Dong, Bundang-Gu, Seongnam-City, Gyeonggi-Do, 463-760, Korea FCC ID: X6VMTMCM900ATL EUT Type: Network Module Model Name: MTM-CM900ATL Date of Test: July 20 ,2011 ~ July 26, 2011 Contact person: Name: Joong Deok Choi Phone #: +82-31-601-3533 Fax #: +82-31-705-4653 Place of Tests: HCT Co., Ltd. 105-1, Jangam-ri , Majang-Myeon, Icheon-si, Kyunggi-Do, 467-811, KOREA. (IC Recognition No. : 5944A-3) 2. EUT DESCRIPTION EUT Type Network Module Model Name MTM-CM900ATL Power Supply DC 3.3 V Battery Type AA ALKALINE Battery X 2 Frequency Range TX: 906 MHz ~ 924 MHz RX: 906 MHz ~ 924 MHz Max.Conducted Output Power: -14.66 dBm (0.034 mW) Modulation Type OQPSK Antenna Specification Manufacturer: Hanwooltechnology Co., Ltd Antenna type: Dipole Antenna Peak Gain : 3.0 dBi FCC PT.15.247 TEST REPORT FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1107FR28 Date of Issue: July 27, 2011 EUT Type: Network Module FCC ID: X6VMTMCM900ATL Page 5 of 33 3. TEST METHODOLOGY The measurement procedure described in the American National Standard for Methods of Measurement of Radio-Noise Emission from Low-Voltage Electrical and Electronic Equipment in the Range of 9kHz to 40GHz(ANSI C63.4-2003) 3.1 EUT CONFIGURATION The EUT configuration for testing is installed on RF field strength measurement to meet the Commissions requirement and operating in a manner that intends to maximize its emission characteristics in a continuous normal application. 3.2 EUT EXERCISE The EUT was operated in the engineering mode to fix the Tx frequency that was for the purpose of the measurements. According to its specifications, the EUT must comply with the requirements of the Section 15.207, 15.209 and 15.247 under the FCC Rules Part 15 Subpart C. 3.3 GENERAL TEST PROCEDURES Conducted Emissions The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the requirements in Section 13.1.4.1 of ANSI C63.4. (Version :2003) Conducted emissions from the EUT measured in the frequency range between 0.15 MHz and 30MHz using CISPR Quasi-peak and average detector modes. Radiated Emissions The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall rotate 360 degrees to determine the position of maximum emission level. EUT is set 3 m away from the receiving antenna, which varied from 1 m to 4 m to find out the highest emission. …

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID : X6VMTMCM900ATL HCT CO., LTD. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1107FR28 1/6 ATTACHMENT D. - SETUP PHOTO - FCC ID : X6VMTMCM900ATL HCT CO., LTD. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1107FR28 2/6 FCC ID : X6VMTMCM900ATL HCT CO., LTD. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1107FR28 3/6 FCC ID : X6VMTMCM900ATL HCT CO., LTD. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1107FR28 4/6 FCC ID : X6VMTMCM900ATL HCT CO., LTD. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1107FR28 5/6 FCC ID : X6VMTMCM900ATL HCT CO., LTD. 105-1, Jangam-ri, Majang-Myeon, Icheon-si, Kyunggi-Do, Korea TEL:+82 31 645 6467 FAX:+82 31 645 6401 www.hct.co.kr Report No. : HCTR1107FR28 6/6

Contact Information

Applicant

Uk Jung(R&D Center Managerial Researcher)
[email protected]+82-31-337-0486Fax: +82-31-339-7216

Test Firm

HCT Co., LTDSang Lee
[email protected]82-31-645-6420Fax: 82-31-645-6401

Technical Specifications

#Rule PartsFrequency RangePower Output
115C906 MHz - 924 MHz34.00 µW
Modular Type
Limited Single Modular Approval
Confidentiality
Long Term
Grant Notes
This is a limited modular approval. Power listed is maximum conducted RF output power. Approval is limited to OEM installation only. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions. OEM integrators and End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device.

Other Applications from MAXFOR Technology Inc.

Smart Gateway - FCC ID X6VMFG-G400 - MAXFOR Technology Inc.
X6VMFG-G400

Smart Gateway

Jul 28, 2014

Equipment Class

DTS - Digital Transmission System
Smart Gateway - FCC ID X6VMFG-G300 - MAXFOR Technology Inc.
X6VMFG-G300

Smart Gateway

Jul 23, 2014

Equipment Class

DTS - Digital Transmission System
Indoor Air Quality Monitor - FCC ID X6VMFA-200 - MAXFOR Technology Inc.
X6VMFA-200

Indoor Air Quality Monitor

Sep 12, 2013

Equipment Class

DTS - Digital Transmission System
Network module - FCC ID X6VMTMCM4000MSP - MAXFOR Technology Inc.