FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. VERDANT ENVIRONMENTAL TECHNOLOGIES/
  3. XEY-ZX-WU

XEY-ZX-WUZX Wired Thermostat

VERDANT ENVIRONMENTAL TECHNOLOGIES
ZX Wired Thermostat - FCC ID XEY-ZX-WU - VERDANT ENVIRONMENTAL TECHNOLOGIES
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 30, 2020
Application Purpose
Original Equipment
Date of Application
Apr 29, 2020
Equipment Note
ZX Wired Thermostat
Frequency Range
2402.00000000 - 2480.00000000
Company
VERDANT ENVIRONMENTAL TECHNOLOGIES
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Page 1 of 1 4/30/2020file:///C:/Jobs/TEM/CB-20-0082/Non-Confidential%20Files/Exhibit%2008%20Users%20...

Cover Letter(s)

Federal Communications Commission Authorization and Evaluation Division Permanent Confidentiality Request regarding application for certification of FCC ID: XEY-ZX-WU/ ICC#:8410A-ZXWU. Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request permanent confidential treatment of information accompanying this application as outlined below: Exhibit Type Block diagram, Schematics, Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public, the public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Jianan Cao

External Photos

ZX WIRED THERMOSTAT External Photos:

ID Label/Location Info

Page 1 of 1 4/29/2020file:///C:/Jobs/TEM/CB-20-0083/Non%20Confidential%20Files/Exhibit%2001%20ID%20...

Internal Photos

ZX WIRED THERMOSTAT Internal Photos:

RF Exposure Info

© TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. April 23, 2020 FCC-XEY-ZX-WU_RF_Exposure Exhibit: RF Exposure – FCC FCC ID: XEY-ZX-WU IC: 8410A-ZXWU © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. April 23, 2020 FCC-XEY-ZX-WU_RF_Exposure 1 Product ZX Root Node Thermostat Verdant Environmental Technologies Inc Client Standard(s) FCC Part 15 Subpart 15.247:2016 FCC KDB 447498:2015 SAR Calculations: 902.8 – 927.7 MHz FHSS transmitter The EUT contains both 902 – 928 MHz and 2402 – 2480 Bands of FHSS transmitters. The firmware guarantees simultaneous operation will not occur and therefore antenna co-location testing is not applicable. This device is designed to be operated handheld and for the purpose of demonstrating compliance with MPE requirements and SAR exemption; we present for a worst case 5mm distance and 100 % duty cycle. 902 – 928 MHz Band FCC Requirements: SAR test exclusion guidance As per FCC KDB 447498 D01 Section 4.3.1 a), the 1-g extremity SAR Test Exclusion Threshold for 100 MHz to 6 GHz at test separation distances ≤ 50 mm is determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] [√f(GHz)] ≤ 3.0 Performing the calculation, of the worst case mentioned above, using the maximum power measured of 12.8mW (see Table 20 in page 50 of TR-7169005571-FCC-ISED-ZX Wired Thermostat.pdf) yields to: 12.8 5 ∙ √ 0.927525=2.47, 2.47 is below the 3.0 worst case limit, so this device complies with FCC requirements ISED Requirements: SAR test exclusion guidance As per Table 1 in RSS-102, Section 2.5.1 at 1900MHz is 7mW at 5mm or less. This device has effective isotropic radiated power (as worst-case vertical polarization at 915MHz, with a peak value of 100 dBμV/m i - 95.2 (factor to convert to EIRP at 3 meters) of 4.8dBm, or 3mW. • 3mW is less than 7mW limit as per section 2.5.1 on RS-102, thus the device meets the exception rules. © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. April 23, 2020 FCC-XEY-ZX-WU_RF_Exposure 1 Product ZX Root Node Thermostat Verdant Environmental Technologies Inc Client Standard(s) FCC Part 15 Subpart 15.247:2016 FCC KDB 447498:2015 2402 – 2480 MHz Band FCC Requirements: SAR test exclusion guidance As per FCC KDB 447498 D01 Section 4.3.1 a), the 1-g extremity SAR Test Exclusion Threshold for 100 MHz to 6 GHz at test separation distances ≤ 50 mm is determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] [√f(GHz)] ≤ 3.0 Performing the calculation, of the worst case mentioned above, using the maximum power measured of 7.56mW (see Table 19 in page 50 of TR-7169005571-FCC-ISED-ZX Wired Thermostat.pdf) yields to: 7.56 5 ∙ √ 0.927525=1.44, 1.44 is below the 3.0 worst case limit, so this device complies with FCC requirements ISED Requirements: SAR test exclusion guidance As per Table 1 in RSS-102, Section 2.5.1 at 2450MHz is 4mW at 5mm or less. This device has effective isotropic radiated power (as worst-case vertical polarization at 915MHz, see, for instance with a peak value of 100 dBμV/m ii - 95.2 (factor to convert to EIRP at 3 meters) of 4.8dBm, or 3mW. • 3mW is less than 4mW limit as per section 2.5.1 on RS-102, thus the device meets the exception rules. i See, pag.90 in TR-7169005571-FCC-ISED-ZX Wired Thermostat.pdf ii See pag.94 in TR-7169005571-FCC-ISED-ZX Wired Thermostat.pdf

Test Report

TÜV SÜD Product Service is a trading name of TUV SUD Ltd 2972 Joseph-A-Bombardier Laval, QC H7P 6E3 Canada TUV SUD Ltd is a TÜV SÜD Group Company Phone: +450-687-4976 www.tuv-sud.ca TÜV SÜD Product Service RESPONSIBLE FOR NAME DATE SIGNATURE Test Specialist Abderrahmane Ferhat 12-09-2019 Authorised Signatory Scott Drysdale 12-09-2019 Signatures in this approval box have checked this document in line with the requirements of TÜV SÜD Product Service document control rules. EXECUTIVE SUMMARY A sample of this product was tested and found to be in compliance withFCC Part 15.247 Subpart C/ ICES 003 Issue 6 and RSS- 247 Issue 2. A2LA Cert. No. 2955.20 DISCLAIMER AND COPYRIGHT This non-binding report has been prepared by TÜV SÜD Canada with all reasonable skill and care. The document is confidential to the potential Client and TÜV SÜD Canada. No part of this document may be reproduced without the prior written approval of TÜV SÜD Canada. © TÜV SÜD. ACCREDITATION Our A2LA Accreditation does not cover opinions and interpretations and any expressed are outside the scope of our A2LA Accreditation. FCC/ISED RF Test Report As per RSS-247 Issue 2 FCC Part 15.247 Subpart C & ICES 003 Issue 6 on the ZX Wired Thermostat IC:8410A-ZXWU; FCCID:XEY-ZX-WU Prepared to: Verdant. Environmental Technologies, Inc. 1850 – 55 th Avenue, Lachine, Quebec, H8T 3J5 CANADA Verdant Environmental Technologies, Inc.. Document Number: PR-7169005571- FCC-ISED, Issue 01 | 2019.09.12 ZX Wired Thermostat COMMERCIAL-IN-CONFIDENCE No part of this document may be reproduced without the prior written approval of TÜV SÜD Canada. © TÜV SÜD. Page 2 of 100 Contents 1Report Summary .........................................................................................................................7 2Introduction .............................................................................................................................. 10 3EUT: ZX WIRED THERMOSTAT .............................................................................................. 15 3.1Specifications: ............................................................................................................................ 15 3.2Modes of Operation .................................................................................................................... 18 3.3Setup Diagram ........................................................................................................................... 18 4Deviations from the Standard ................................................................................................. 19 5Measurement Uncertainty ....................................................................................................... 19 699% Bandwidth ......................................................................................................................... 20 6.1Purpose & Methods .................................................................................................................... 20 6.2Test Specifications ..................................................................................................................... 20 6.3Test Results ............................................................................................................................... 21 6.4Graphs ........................................................................................................................................ 22 6.5Test Instruments ......................................................................................................................... 27 76dB Bandwidth of Digitally Modulated Systems ................................................................... 28 7.1Purpose & Methods .................................................................................................................... 28 7.2Test Specifications ..................................................................................................................... 28 7.3Test Results ............................................................................................................................... 29 7.4Graphs ........................................................................................................................................ 30 7.5Test Instruments ......................................................................................................................... 33 8Hopping Channel ...................................................................................................................... 34 8.1Purpose & Methods .................................................................................................................... 34 8.2Test Specifications ..................................................................................................................... 34 8.3Limits .......................................................................................................................................... 35 8.4Test Results ............................................................................................................................... 35 8.5Graphs ........................................................................................................................................ 36 8.6Test Instruments ......................................................................................................................... 39 9Channel Separation.................................................................................................................. 40 9.1Purpose & Methods .................................................................................................................... 40 9.2Test Specifications ..................................................................................................................... 40 9.3Limits .............................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

ALAIN BELANGER
[email protected]514-344-4448Fax: 514-344-5977

Test Firm

TUV SUD CANADA (Laval)William (Mac) Elliott
[email protected]813-284-2736

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz7.50 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.

Other Applications from VERDANT ENVIRONMENTAL TECHNOLOGIES

Thermostat - FCC ID XEYWX-DB - VERDANT ENVIRONMENTAL TECHNOLOGIES
XEYWX-DB

Thermostat

Feb 17, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
High Voltage Thermostat - FCC ID XEY-ZX-HV - VERDANT ENVIRONMENTAL TECHNOLOGIES
XEY-ZX-HV

High Voltage Thermostat

Jan 27, 2021

Equipment Class

DTS - Digital Transmission System
ZX Door Switch - FCC ID XEY-ZX-DS - VERDANT ENVIRONMENTAL TECHNOLOGIES
XEY-ZX-DS

ZX Door Switch

May 10, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Low Voltage Thermostat - FCC ID XEY-ZX-LV - VERDANT ENVIRONMENTAL TECHNOLOGIES
XEY-ZX-LV

Low Voltage Thermostat

May 05, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
ZX Motion Sensor - FCC ID XEY-ZX-MS - VERDANT ENVIRONMENTAL TECHNOLOGIES
XEY-ZX-MS

ZX Motion Sensor

Apr 30, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter