Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
by English OhMiBod is committed to bringing you high quality technology enabled pleasure products and accessories. Before you begin enjoying blueMotion ™ , please take a moment to review this manual. How it Works DOWNLOAD OhMiBod ® Remote App TURN ON blueMotion ™ PAIR devices + + blueMotion ™ - What’s in the box Bluetooth ® enabled wearable vibrator Power button USB charging socket • Blue lace thong OSFM (one size fits most) • USB charging cable • Privacy pouch Bluetooth ® Mode: 1. Press 3-4 seconds to turn on. NOTE: Blinking blue LED power button indicates vibe is ready to connect via Bluetooth ® . 2. Pair to phone/tablet. Bluetooth ® range up to 26ft (8m) NOTE: Pairing instructions can be found on next page. 3. Launch OhMiBod ® Remote App. 4. Press and hold for 3-4 seconds to turn off. NOTE: After 30 minutes of non-use, the massager with automatically shut off to conserve battery life. Using blueMotion ™ - 2 Modes of Operation Manual Mode: 1. Press 3-4 seconds to turn on. 2. Press again to switch to manual mode. First pulsation is a continuous vibration. This confirms manual mode is active. Press to move to next pulsation pattern. There are a total of 4 pulsations. Pressing the button again will cycle back to Bluetooth ® mode. NOTE: A white LED power button confirms manual mode. 3. Press for 3-4 seconds to turn off. How it Works Blinking Pairing Your Phone/Tablet 1. Turn on blueMotion ™ massager. NOTE: Blinking blue LED on power button indicates massager is ready to pair. 2. Open the Bluetooth ® settings on your phone/tablet. 3. Select “OhMiBod”. This is the blueMotion ™ massager. 4. Select “Pair”. When prompted, enter the PIN 0000. 0000 5. LED on power button glows steady ( )when massager is paired to phone/tablet. Controlling blueMotion ™ Via App 1. Download and launch OhMiBod ® Remote App. AVAILABLE FOR DOWNLOAD ON: 2. Blue indicates connection to phone/tablet. Initial App instructions pop-up upon first use. ADDITIONAL SUPPORT can also be found at: OhMiBod.com/app. Additional information provided “in App” on Support. Connected to phone/tablet Charging blueMotion ™ Simply plug the USB charging cable provided with blueMotion ™ into the USB port on your computer or USB wall charger adapter. Connect the other end of the cable into the charging socket on the end of blueMotion ™ (see diagram). The LED on blueMotion ™ will blink indicating the massager is charging. Please be sure that the massager is completely dry before charging. LED will glow steady ( ) when fully charged. NOTE: The USB port is for charging use only, no data transmission functionality. When product is charging, the product will not be able to vibrate until the USB cable is removed from charging socket. Troubleshooting If the LED does not blink when the product is connected to the USB cable, check to make sure the USB cable is properly connected to the USB port and blueMotion ™ . Battery Disposal • blueMotion ™ contains a rechargeable battery. Please do not dispose of this product with normal household waste. • Please dispose of this product at the appropriate electrical and electronic equipment recycling disposal locations in accordance with government regulations. • The recycling of this product appropriately will help to protect our environment ≈ 1.5-2 HRS TO REACH FULL CHARGE Specifications blueMotion ™ Materials: Body-safe ABS Size: 3 3/4” length, 1 3/4” width, 0.5” depth (90mm length, 43mm width, 13mm depth) Weight: 2.3 oz. (65g) Battery: Lithium-ion, 3.7V with 200mAH Charging: 1.5-2 hours User time: 1 hour WIRELESS SPECIFICATIONS: Bluetooth® Version 2.0 Frequency: 2.402-2.480GHz Receive sensitivity: Better than -82dBm Range: 26ft (8m) Data rates: Up to 3Mbps (over the air) UART data transfer rate: 115200bps Care and Cleaning • blueMotion ™ is splash proof only. When cleaning, avoid submerging in water and getting any water into the charging socket. • Clean after every use with mild soap and water. Dry thoroughly. • Store in privacy pouch to keep blueMotion ™ clean and safe until next use. Important Safeguards • Do not use on areas that are swollen, inflamed or have skin lacerations. • Stop using the massager if you experience pain or discomfort. • Do not submerge in water. • Do not sure while bathing or in the shower. No medical claims are warranted or implied by the use of this product. Warranty OhMiBod warrants this product for a period of one (1) year from the date of original purchase, against defects due to faulty workmanship or materials. In the event that this product fails during the warranty period, simply email us at [email protected] and provide us with a valid proof of the date of original purchase and we will replace the faulty product at no extra charge. This warranty does not cover cosmetic deterioration caused by normal wear and tear or damage caused by accident, misuse, neglect or other use not in accordance with this instruction manual. Any attempt to open or take apart this product or its accessories will void the warranty. Contact Us If you have any questions regarding your new product, please check out additional information at www.ohmibod.com/customercare. You can also reach us via email at [email protected]. Special Note from Founder “OhMiBod’s goal is to reflect the collective personality of our customers who have an open, honest attitude toward sexuality and personal pleasure. My hope is that OhMiBod becomes a symbol of liberation, reflecting new and progressive attitudes toward personal pleasure for the young and the young at heart...People who are comfortable with their bodies, know what feels good and who, not only aren’t afraid to admit it, are empowered to go after it.” FCC ID: XG5OMBBM01 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Th…
Text truncated - open the document above for the full version.
ZHUHAI WINGPOW EROTIC & NOVELTY MANUFACTURING CO., LTD 022311 – 6 Authority to Act as Agent Date: 2014-03-06 American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: __SGS-CSTC Standards Technical Services Co., Ltd.__ is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b) , to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Expiration Date: _____(Typically 8 – 12 months)_____ By: __________________________ _____ Jinwei He _ (Signature 1 ) (Print name) Title: __ Head of engineering Department__ On behalf of: _ ZHUHAI WINGPOW EROTIC & NOVELTY MANUFACTURING CO., LTD _ (Company Name) Telephone: __+86 7563936002 __________ 1 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.
ZHUHAI WINGPOW EROTIC & NOVELTY MANUFACTURING CO., LTD 022311 – 6 Request for Confidentiality Date: 2014-03-06_ Subject: Confidentiality Request for: __FCC ID: XG5OMBBM01__ Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Permanent* 2 Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term Permanent* User’s Manual *Note: ______(Insert Explanation as Necessary)______ __ ZHUHAI WINGPOW EROTIC & NOVELTY MANUFACTURING CO., LTD has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of ___(specify number of days not to exceed 180 ) 3 ___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: The applicant understands that until such time that IC distinguishes between Short Term and Permanent Confidentiality, either type of marked exhibit above will simply be marked Confidential when submitted to IC. Sincerely, By: __________________________ _ Jinwei He / Head of engineering Department __ (Signature/Title 4 ) (Print name) 2 - The asterisked items (*) require further justification before permanent confidentiality will be allowed. These also currently require review by the FCC under their Permit-But-Ask policy before the grant is issued and can delay completion of an application. Further justification should be added to the note above. One such example for a potted device would be: “The EUT is FULLY potted using a non-removable epoxy based material. Removal of potting material causes irreparable damage to internal circuitry. See photographs exhibits that outline the device before and after potting.” 3 - Please refer to http://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details. 4 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.
External Photo
Internal Photo
SGS-CSTC Standards Technical Services Co., Ltd. Application No..: GZEM1402000683RF Page: 1 of 1 FCC ID: This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. RF Exposure Compliance Requirement The product belongs to standalone portable device base the FCC rule part 2.1091&2.1093. The transmission frequencies of the device are between 100 MHz and 6 GHz. The worst case test separation distance is 5mm. The Max Conducted Output Power and SAR Test Exclusion Threshold (mW) are listed below: Transmit frequency (GHz) Max Conducted Output Power (mW) SAR Test Exclusion Threshold (mW) 2.402 2.636 9.7 2.441 2.193 9.6 2.480 1.866 9.5 The SAR Test Exclusion Threshold for 100 MHz to 6 GHz is calculated from: 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. According to SAR Exclusion Threshold in KDB 447498 (D01) General RF Exposure Guidance v05, the SAR report is not required.
SGS-CSTC Standards Technical Services Co., Ltd. 19 8 Ke zhu Roa d, Scient ech Park, Guangzhou Economic & Technolo gical De velopment D istrict, Guangzhou, China 510663 Telephon e: +86 (0) 20 8 2155555 Fax: +86 (0) 20 820750 59 Email: ee. guangzh [email protected] Report No.: GZEM140200068301 Page: 1 of 68 FCC ID: XG5OMBBM01 Authorized Signature: Richard Li Manager The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. All test results in this report can be traceable to National or International Standards. This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only 1 Cover Page TEST REPORT Application No.: GZEM1402000683RF Applicant: Zhuhai Wingpow Erotic & Novelty Manufacturing CO. LTD FCC ID: XG5OMBBM01 Product Name: Blue Motion Product Description: Bluetooth control with 2.4 GHz as carrier Model No.: OMBBM01 Trade mark: OhMiBod Standards: 47 CFR PART 15 Subpart C: 2013 section 15.247 Date of Receipt: 2014-02-26 Date of Test: 2014-03-06 Date of Issue: 2014-03-21 Test Result : Pass* * In the configuration tested, the EUT detailed in this report complied with the standards specified above. Please refer to section 3 of this report for further detail. SGS-CSTC Standards Technical Services Co., Ltd. Report No.: GZEM140200068301 Page: 2 of 68 FCC ID: XG5OMBBM01 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 2 Version Revision Record Version Chapter Date Modifier Remark 00 2014-03-21 Original Authorized for issue by: Tested By 2014-03-06 (Daniel He) /Signature Date Prepared By 2014-03-18 (Liky Chen) /Signature Date Checked By 2014-03-21 (Storm Shu) /Reviewer Date SGS-CSTC Standards Technical Services Co., Ltd. Report No.: GZEM140200068301 Page: 3 of 68 FCC ID: XG5OMBBM01 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 3 Test Summary Test Test Requirement Test method Result Antenna Requirement FCC PART 15 C section 15.247 (c) and Section 15.203 FCC PART 15 C section 15.247 (c) and Section 15.203 PASS Occupied Bandwidth FCC PART 15 C section 15.247 (a)(1) ANSI C63.10: Clause 6.9.1 PASS Carrier Frequencies Separated FC…
Text truncated - open the document above for the full version.
Test Setup Photo 1.1 RADI ATE D SP URI OU S EM ISSIO N TE ST SETUP 30 MHz to 1 GHz: Above 1 GHz:
198 KEZHU Road, Scientech Park · Guangzhou · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.20 mW |

blueMotion NEX 3
Equipment Class
DTS - Digital Transmission System
Lumen
Equipment Class
DTS - Digital Transmission System
BlueMotion NEX2
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Massager
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Massager
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter