Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Nov 02, 2010
Application Purpose
Original Equipment
Date of Application
Nov 01, 2010
Equipment Note
3G Module
Frequency Range
1851.25000000 - 1908.75000000
Company
Franklin Technology Inc.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Mobile Broadband module M600C User Manual Sprint Smart View M600C Mobile Broadband Module 2 CONTENTS 1. BEFORE USING M600C......................................................................................4 Introduction...................................................................................................5 System Requirement.......................................................................................5 2. DEVICE ACTIVATION.........................................................................................6 Device Activation Overview ..............................................................................7 Activation Wizard Tutorial ................................................................................8 3. The Sprint Smart View Interface....................................................................... 11 The Main Window ......................................................................................... 12 The Mobile Control Panel ............................................................................... 12 The Wi-Fi Control Panel: In Detail ................................................................... 13 Automatic vs. Manual Connection.................................................................... 13 The File Menu .............................................................................................. 14 The Tools Menu ............................................................................................ 14 The Help Menu ............................................................................................. 16 4. ESTABLISHING MOBILE................................................................................... 17 BROADBADN CONNECTIONS ............................................................................... 17 Manually Connecting to the Sprint Mobile Broadband Network............................. 19 Automatic Connection Upon Device Attachment ................................................ 19 Multiple Broadband Devices ........................................................................... 21 Locking and Unlocking Your Sprint Mobile Broadband Device............................... 21 3G Bearer Types........................................................................................... 22 Mobile Info Window ...................................................................................... 23 5. THE APPLICATION LAUNCHER .......................................................................... 24 The Application Launch Menu: In Detail ........................................................... 25 Configuring Launched Applications .................................................................. 25 Automatically Launching Applications .............................................................. 27 Monitoring Launched Applications ................................................................... 29 6. SPRINT SMARTVIEW SETTINGS ........................................................................ 31 M600C Mobile Broadband Module 3 Accessing the Settings Window....................................................................... 32 Settings: Acceleration ................................................................................... 32 Settings: App Launcher ................................................................................. 33 Settings: Client ............................................................................................ 33 Settings: Hardware....................................................................................... 34 Settings: Location/GPS.................................................................................. 36 Settings: Sounds.......................................................................................... 38 Settings: Updates......................................................................................... 39 Settings: VPN .............................................................................................. 40 7. SUPPORT ...................................................................................................... 42 Trouble Shooting .......................................................................................... 43 WARRANTY.................................................................................................. 44 SAFETY INFORMATION .................................................................................. 45 M600C Mobile Broadband Module 4 Section 1, 1. BEFORE USING M600C  Introduction  System Requirement M600C Mobile Broadband Module 5 Introduction Welcome to the help pages of the Sprint Smart View software. The Help system is designed to answer users' questions on how to perform specific tasks and to explain the Sprint Smart View's functions. The menu system to the left allows users to browse help topics while the Index and Search tabs provide other mechanisms to access available help topics. System Requirement The system requirements for basic installation and operation of the Sprint Smart View software are shown in the table below. Windows XP Windows Vista Windows 7 Processor 300MHz 800MHz (1GHz recommended) 1GHz RAM 256MB 1GB (2GB recommended) 1GB (2GB recommended) Hard Drive Space 70MB 70MB 70MB Internet Explorer IE 5.5 IE 7 IE 8 OS Service Pack Service Pack 3 Service Pack 2 Additional Requirements:  Windows Vista and Windows 7 operation requires a DirectX 9.0 (or better) graphics accelerator  Internet Connection (if downloading the installer from the Internet)  CD-ROM (if installing from CD) M600C Mobile Broadband Module 6 Section 2, 2. DEVICE ACTIVATION  Device Activation Overview  Activation Wizard Tutorial M600C Mobile Broadband Module 7 Device Activation Overview Some Sprint Mobile Broadband devices may require activation (programming) prior to use. If your device needs such an action, Sprint Smart View will inform you and start the ac…

Text truncated - open the document above for the full version.

Attestation Statements

Applicant/Grantee Franklin Technology Inc. FCC ID: XHG-M600C Section 15.212 Modular Transmitters Request for Modular Approval Request for Limited Modular Approval Requirements EUT Conditions Comply (Y/N) Single Modular Approval Requirements 1 The radio elements of the modular transmitter must have their own shielding. The physical crystal and tuning capacitors may be located external to the shielded radio elements. Refer to external photos. Shield is over the radio circuit module. Y 2 The modular transmitter must have buffered modulation/data inputs (if such inputs are provided) to ensure that the module will comply with Part 15 requirements under conditions of excessive data rates or over-modulation. All inputs to the modules are buffered through logic or microprocessor inputs. Y 3 The modular transmitter must have its own power supply regulation. Internal power regulator. Y 4 The modular transmitter must comply with the antenna and transmission system requirements of Sections 15.203, 15.204(b) and 15.204(c). The antenna must either be permanently attached or employ a “unique” antenna coupler (at all connections between the module and the antenna, including the cable). The “professional installation” provision of Section 15.203 is not applicable to modules but can apply to limited modular approvals under paragraph (b) of this section. Module contatins a hirose connector. The module will go inside final product where the antenna(s) will be integral to the end product, which can be considered permanently attached. Y 5 The modular transmitter must be tested in a stand-alone configuration, i.e., the module must not be inside another device during testing for compliance with Part 15 requirements. Unless the transmitter module will be battery powered, it must comply with the AC line conducted requirements found in Section 15.207. AC or DC power lines and data input/output lines connected to the module must not contain ferrites, unless they will be marketed with the module (see Section 15.27(a)). The length of these lines shall be the length typical of actual use or, if that length is unknown, at least 10 centimeters to insure that there is no coupling between the case of the module and supporting Module was tested outside. Refer to test setup photos in test report Y equipment. Any accessories, peripherals, or support equipment connected to the module during testing shall be unmodified and commercially available (see Section 15.31(i)). 6 The modular transmitter must be equipped with either a permanently affixed label or must be capable of electronically displaying its FCC identification number. (A) If using a permanently affixed label, the modular transmitter must be labeled with its own FCC identification number, and, if the FCC identification number is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: XYZMODEL1” or “Contains FCC ID: XYZMODEL1.” Any similar wording that expresses the same meaning may be used. The Grantee may either provide such a label, an example of which must be included in the application for equipment authorization, or, must provide adequate instructions along with the module which explain this requirement. In the latter case, a copy of these instructions must be included in the application for equipment authorization. (B) If the modular transmitter uses an electronic display of the FCC identification number, the information must be readily accessible and visible on the modular transmitter or on the device in which it is installed. If the module is installed inside another device, then the outside of the device into which the module is installed must display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains FCC certified transmitter module(s).” Any similar wording that expresses the same meaning may be used. The user manual must include instructions on how to access the electronic display. A copy of these instructions must be included in the application for equipment authorization. Refer to label provided. Y 7 The modular transmitter must comply with any specific rules or operating requirements that ordinarily apply to a complete transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements. A copy of these instructions must be included in the application for equipment authorization. Refer to manual. Y 8 The modular transmitter must comply with any applicable RF exposure requirements in its final configuration. Refer to MPE calculation in the Test report. Y A limited modular approval may be granted for single or split modular transmitters that do not comply with all of the above requirements, e.g., shielding, minimum signaling amplitude, buffered modulation/data inputs, or power supply regulation, if the manufacturer can demonstrate by alternative means in the application for equipment authorization that the modular transmitter meets all the applicable Part 15 requirements under the operating conditions in which the transmitter will be used. Limited modular approval also may be granted in those instances where compliance with RF exposure rules is demonstrated only for particular product configurations. The applicant for certification must state how control of the end product into which the module will be installed will be maintained such that full compliance of the end product is always ensured.

Cover Letter(s)

Request for Confidentiality Compliance Certification Services Date: 2010. 10. 19 47173 Benicia St. Fremont, CA 94538 RE: Certification Application FCC ID: XHG-M600C Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rule, the applicant hereby requests confidential treatment of information accompanying this application as outlined below: CONFIDENTIAL AND SHORT-TERM CONFIDENTIAL LIST Exhibit Description 1 Block Diagram 2 Parts Lists 3 Schematics CONFIDENTIAL 4 External Photos 5 Internal Photos 6 Test-Setup Photos SHORT-TERM CONFIDENTIAL 7 User’s Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457 & 0.459, disclosure od this application and all accompanying documentation will not be made before the date of the GRANT for this application ́. Thank you for your attention in this matter. Applicant’s Company : Franklin Technology Inc. address : 1505 Digital Tower Aston, 505-15 Gasan-dong,Gumcheon-gu, Seoul Korea Signature : ____________________________ Job Title and Dept. :Senior Manager

Cover Letter(s)

Request for Confidentiality Compliance Certification Services Date: 2010. 10. 19 47173 Benicia St. Fremont, CA 94538 RE: Certification Application FCC ID: XHG-M600C Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rule, the applicant hereby requests confidential treatment of information accompanying this application as outlined below: CONFIDENTIAL AND SHORT-TERM CONFIDENTIAL LIST Exhibit Description 1 Block Diagram 2 Parts Lists 3 Schematics CONFIDENTIAL 4 Operational Description 5 External Photos 6 Internal Photos 7 Test-Setup Photos SHORT-TERM CONFIDENTIAL 8 User’s Manual The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457 & 0.459, disclosure od this application and all accompanying documentation will not be made before the date of the GRANT for this application ́. Thank you for your attention in this matter. Applicant’s Company : Franklin Technology Inc. address : 1505 Digital Tower Aston, 505-15 Gasan-dong,Gumcheon-gu, Seoul Korea Signature : ____________________________ Job Title and Dept. :Senior Manager

External Photos

FCC ID : XHG-M600C HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1002FR06 1/2 FCC ID : XHG-M600C HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCTR1002FR06 2/2

ID Label/Location Info

XHG-M600C

Internal Photos

FCC ID : XHG-M600 HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr 1/2 FCC ID : XHG-M600 HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr 2/2

RF Exposure Info

FCC ID:XHG-M600C HCT CO., LTD SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL : + 82 31 639 8565 FAX : + 82 31 639 8525 www.hct.co.kr 1 of 3 RF Exposure Statement 1. LIMITS According to §1.1310 and §2.1091 RF exposure is calculated. (B) Limits for General Population/Uncontrolled Exposures Frequency range (MHz) Electric field Strength (V/m) Magnetic field Strength (A/m) Power density (mW/cm²) Averaging time (minutes) 0.3 - 1.34....................................... 1.34 - 30....................................... 30 - 300....................................... 300 - 1500.................................... 1500 - 100.000................................. 614 824/f 27.5 ............... ............... 1.63 2.19/f 0.073 ............... ............... *(100) *(180/ f²) 0.2 f/1500 1.0 30 30 30 30 30 F = frequency in MHz * = Plane-wave equivalent power density 2. MAXIMUM PERMISSIBLE EXPOSURE Prediction Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S = PG/4πR² S = Power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna FCC ID: XHG-M600C HCT CO., LTD SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL : + 82 31 639 8565 FAX : + 82 31 639 8525 www.hct.co.kr 2 of 3 2-1. CDMA Band Max Peak output Power at antenna input terminal (dBm) 24.080 Max Peak output Power at antenna input terminal (mW) 255.859 Prediction distance (cm) 20.000 Prediction frequency (MHz) 824.700 Antenna Gain(typical) (dBi) 0.000 Antenna Gain(numeric) 1.000 Power density at prediction frequency (mW/cm²) 0.05090 MPE limit for uncontrolled exposure at prediction frequency (mW/cm²) 0.550 2-2. PCS Band Max Peak output Power at antenna input terminal (dBm) 24.060 Max Peak output Power at antenna input terminal (mW) 254.683 Prediction distance (cm) 20.000 Prediction frequency (MHz) 1851.250 Antenna Gain(typical) (dBi) 0.000 Antenna Gain(numeric) 1.000 Power density at prediction frequency (mW/cm²) 0.05067 MPE limit for uncontrolled exposure at prediction frequency (mW/cm²) 1.00000 FCC ID: XHG-M600C HCT CO., LTD SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL : + 82 31 639 8565 FAX : + 82 31 639 8525 www.hct.co.kr 3 of 3 3. RESULTS The power density level at 20 cm is 0.05090mW/cm², which is below the uncontrolled exposure limit of 0.550 mW/cm² at 824.700 MHz for CDMA Band. The power density level at 20 cm is 0.05067 mW/cm², which is below the uncontrolled exposure limit of 1.0 mW/cm² at 1851.25 MHz for PCS Band.

Test Report

FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1010FFR12-2 Test Dates: November 02, 2010 EUT Type: 3G Module FCC ID: XHG-M600C Page 2 of 40 Version TEST REPORT NO. DATE DESCRIPTION HCTR1010FR12 October 19, 2010 First Approval Report HCTR1010FR12-1 October 29, 2010 Change the test site description HCTR1010FR12-2 November 02, 2010 Delete ERP/ EIRP Test FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1010FFR12-2 Test Dates: November 02, 2010 EUT Type: 3G Module FCC ID: XHG-M600C Page 3 of 40 Table of Contents 1. GENERAL INFORMATION ..........................................................................................................................4 2. INTRODUCTION ..........................................................................................................................................5 2.1. EUT DESCRIPTION...........................................................................................................................5 2.2. MEASURING INSTRUMENT CALIBRATION ...................................................................................5 2.3. TEST FACILITY .................................................................................................................................5 3. DESCRIPTION OF TESTS ..........................................................................................................................6 3.1 EFFECTIVE RADIATED POWER/EQUIVALENT ISOTROPIC RADIATED POWER.......................6 3.2 PEAK- TO- AVERAGE RATIO ...........................................................................................................7 3.3 OCCUPIED BANDWIDTH..................................................................................................................8 3.4 SPURIOUS AND HARMONIC EMISSIONS AT ANTENNA TERMINAL...........................................9 3.5 RADIATED SPURIOUS AND HARMONIC EMISSIONS ...............................................................10 3.6 FREQUENCY STABILITY / VARIATION OF AMBIENT TEMPERATURE ...................................11 4. LIST OF TEST EQUIPMENT ...................................................................................................................12 5. SUMMARY OF TEST RESULTS .............................................................................................................13 6. SAMPLE CALCULATION ........................................................................................................................14 7. TEST DATA ..............................................................................................................................................15 7.1 CONDUCTED OUTPUT POWER ...................................................................................................15 7.2 OCCUPIED BANDWIDTH ..............................................................................................................16 7.3 CONDUCTED SPURIOUS EMISSIONS ........................................................................................16 7.3.1 BAND EDGE.........................................................................................................................16 7.4 RADIATED SPURIOUS EMISSIONS .............................................................................................17 7.4.1 RADIATED SPURIOUS EMISSIONS(CDMA MODE) .........................................................17 7.4.2 RADIATED SPURIOUS EMISSIONS(PCS CDMA MODE) .................................................18 7.5 FREQUENCY STABILITY / VARIATION OF AMBIENT TEMPERATURE ...................................19 7.5.1 FREQUENCY STABILITY (CDMA)......................................................................................19 7.5.2 FREQUENCY STABILITY (PCS CDMA) .............................................................................20 8. TEST PLOTS............................................................................................................................................21 FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1010FFR12-2 Test Dates: November 02, 2010 EUT Type: 3G Module FCC ID: XHG-M600C Page 4 of 40 MEASUREMENT REPORT 1. GENERAL INFORMATION Applicant Name: Franklin Technology Inc. Address: 1505 Digital Tower Aston, 505-15 Gasan-dong, Gumcheon-gu, Seoul, Korea Contact Person: Name: Michael Chun Phone #: TEL :+82-70-8260-343 / FAX : +82-2-2082-822 FCC ID: XHG-M600C Application Type: Certification FCC Classification: PCS Licensed Transmitter (PCB) FCC Rule Part(s): §22, §24, §2 EUT Type: 3G Module Model(s): M600C Tx Frequency: 824.70 — 848.31 MHz (CDMA) 1 851.25 — 1 908.75 MHz (PCS CDMA) Rx Frequency: 869.70 — 893.31 MHz (CDMA) 1 931.25 — 1 988.75 MHz (PCS CDMA) Max. Conducted Power: 0.254 W CDMA (24.05 dBm) / 0.248 W PCS CDMA (23.96 dBm)/ 0.255 W CDMA EVDO (24.08 dBm) / 0.254 W PCS EVDO (24.06 dBm) Emission Designator(s): 1M28F9W (CDMA) / 1M28F9W (PCS CDMA) 1M27F9W (CDMA EVDO), 1M28/F9W (PCS CDMA EVDO) Date(s) of Tests: October 05, 2010 ~ October 15, 2010 FCC CERTIFICATION REPORT www.hct.co.kr Test Report No. HCTR1010FFR12-2 Test Dates: November 02, 2010 EUT Type: 3G Module FCC ID: XHG-M600C Page 5 of 40 2. INTRODUCTION 2.1. EUT DESCRIPTION The M600C 3G Module consists of Cellular CDMA, PCS CDMA, EVDO Rev.0 and EVDO Rev.A. 2.2. MEASURING INSTRUMENT CALIBRATION The measuring equipment, which was utilized in performing the tests documented herein, has been calibrated in accordance with the manufacturer's recommendations for utilizing calibration equipment, which is traceable to recognized national standards. 2.3. TEST FACILITY The SAC(Semi-Anechoic Chamber) and conducted measurement facility used to collect the radiated data are located at the 105-1, Jangam-ri , Majang-Myeon, Icheon-si, 467-811, KOREA. The site is constructed in conformance with the requirements of ANSI C63.4 and CISPR Publication 22. Detailed description of test facility was submitted to the Commission and accepted dated June 10, 200…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID : XHG-M600C HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr 1/5 ATTACHMENT D. - SETUP PHOTO - FCC ID : XHG-M600C HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr 2/5 FCC ID : XHG-M600C HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr 3/5 FCC ID : XHG-M600C HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr 4/5 FCC ID : XHG-M600C HCT CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr 5/5

Contact Information

Applicant

James Lee(R&D HW team Leader)
[email protected]82-70-8228-6445Fax: 82-2-862-8923

Test Firm

HCT Co., LTDSang Lee
[email protected]82-31-645-6420Fax: 82-31-645-6401

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224E1.85 GHz - 1.91 GHz250.00 mW1M28F9W2.5 ppm
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. Modular Approval for use as a module in mobile-only. The exposure conditions, antenna gain including cable loss must not exceed 0.0dBi for purposes of 2.1043 and 2.1091. This device is allowed only for OEM integration into host products; consumer or end-user installation is not allowed. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. The final product operating with this transmitter must include operating instructions and applicable warnings for end users and installers to satisfy RF exposure compliance requirements. OEM integrators must be informed of these specific requirements. This Grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device.

Other Applications from Franklin Technology Inc.

XHG-M3100L

5G Module

Feb 04, 2026

Equipment Class

PCB - PCS Licensed Transmitter
XHG-M3100

Module

Dec 04, 2024

Equipment Class

PCB - PCS Licensed Transmitter
XHG-RG350

Mobile Hotspot

Dec 02, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Mobile Hotspot CG890 - FCC ID XHG-CG890 - Franklin Technology Inc.
XHG-CG890

Mobile Hotspot CG890

Mar 28, 2023

Equipment Class

DTS - Digital Transmission System
Mobile Hotspot - FCC ID XHG-RG2102 - Franklin Technology Inc.
XHG-RG2102

Mobile Hotspot

Feb 01, 2023

Equipment Class

PCB - PCS Licensed Transmitter