FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. LongSung Technology (Shanghai)Co.,Ltd./
  3. XHZU3500

XHZU3500MODULE

LongSung Technology (Shanghai)Co.,Ltd.
MODULE - FCC ID XHZU3500 - LongSung Technology (Shanghai)Co.,Ltd.
Click to zoom

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Oct 31, 2012
Application Purpose
Original Equipment
Date of Application
Oct 30, 2012
Equipment Note
MODULE
Frequency Range
1850.20000000 - 1909.80000000
Company
LongSung Technology (Shanghai)Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

U3500_Hardware_User_Guide _V2.0 Page 1 of 82 U3500_Hardware_User_Guide _V2.0 U3500_Hardware_User_Guide _V2.0 Page 2 of 82 IMPORTANT NOTICE COPYRIGHT NOTICE Copyright©2010, LongSung Technology (Shanghai) Co., Ltd. All rights reserved. TRADEMARKS LongSung Technology (Shanghai) Co., Ltd’s products are exclusively owned by LongSung Technology (Shanghai) Co., Ltd. References to other companies and their products use trademarks owned by the respective companies and are for reference purpose only. CONFIDENTIALITY The information contained here (including any attachments) is confidential. The recipient here acknowledges the confidentiality of this document, and except for the specific purpose, this document shall not be disclosed to any third party. WARRANTY DISCLAIMER LongSung Technology (Shanghai) Co., Ltd makes no representations or warranties, either express or implied, by or with respect to anything in this document, and shall not be liable for any implied warranties of merchantability or fitness for a particular purpose or for any indirect, special or consequential damages. NO GUARANTEE Our company will not take any responsibility for any damage caused by the customer’s abnormal operation. Please refer to specification and designing reference guide. Our company have right to modify the document according to technical requirement with no announcement to the customer. Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and U3500_Hardware_User_Guide _V2.0 Page 3 of 82 on, the user is encouraged to try to correct the interference by one of the following measures:  Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This device is intended only for OEM integrators under the following conditions: 1)The antenna must be installed such that 20 cm is maintained between the antenna and users. 2)The transmitter module may not be co-located with any other transmitter or antenna. As long as 2 conditions above are met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed. IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization. End Product LabelingThis transmitter module is authorized only for use in device where the antenna may be installed such that 20 cm may be maintained between the antenna and users. The final end product must be labeled in a visible area with the following: “Contains FCC ID: XHZU3500”. The grantee's FCC ID can be used only when all FCC compliance requirements are met. Manual Information To the End UserThe OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module.The end user manual shall include all required regulatory information/warning as show in this manual. U3500_Hardware_User_Guide _V2.0 Page 4 of 82 Contents 1. Overview .................................................................................................................................. 9 1.1. Purpose of the document ....................................................................................... 9 1.2. Summary ...................................................................................................................... 9 1.3. Correlative documents ............................................................................................ 9 1.4. Document’s history ................................................................................................. 10 1.5. Abbreviations ............................................................................................................ 10 2. Introduction........................................................................................................................... 12 2.1. Key features ................................…

Text truncated - open the document above for the full version.

Cover Letter(s)

FCC ID: XHZU3500 Modular Approval Request Letter Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch October 31, 2012 Dear Application Examiner, We, Longsung Technology(Shanghai) Co. Ltd., claim that the EUT, FCC ID: XHZU3500 is a WWAN module and would like to have your authorization as a modular approval specific to the mobile RF exposure condition. The requirements of section 15.212 of FCC rules have been met and shown on the following statements. 1. “The modular transmitter must have its own RF shielding.” The radio portion of this module has been shielded, please see exhibition External Photo. 2. “The modular transmitter must have buffered modulation/data inputs.” The EUT has buffered data input, it is integrated in chip QSC6240 (Transceiver embedded) and QSC6240 (Power IC embedded). 3. “The modular transmitter must have its own power supply regulation.” The part number of this regulator is QSC6240 (Power IC embedded). 4. “The modular transmitter must comply with the antenna requirements of section 15.203 and 15.204(C).” The EUT meets the FCC antenna requirements. The spurious emission, unique antenna connector and photo of antennas are shown in the test report. 5. “The modular transmitter must be tested in a stand-alone configuration” The EUT was tested in a stand-alone configuration via a USB extender. Please see section Photographs of Test Configuration in the test report, the EUT was plugged in this extender. 6. “The modular transmitter must be labeled with its own FCC ID number.” Please see exhibition Label Sample for the FCC ID of this module. And also in the exhibition Users Manual, there are instructions give to the OEM on how to label the end product. FCC ID: XHZU3500 7. “The modular transmitter must comply with any specific rule or operating requirements applicable to the transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements.” The EUT is compliant with all applicable FCC rules. Detail instructions for maintaining compliance are given in the Users Manual. 8. “The modular transmitter must comply with any applicable RF exposure requirements.” The EUT is compliant with all applicable RF exposure requirements. RF Exposure is addressed in the RF exposure exhibition. Please contact me if you have any further question. Thanks for your attention. Best Regards, ____________________________ Daniel Lee Vice President Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

External Photos

Page 1 CONSTRUCTION PHOTOS OF EUT

ID Label/Location Info

Label Location FCC ID: XHZU3500 Label Location

ID Label/Location Info

08 . 10 . WM7285D_LQB0014.1.0_M034WCDMA Cellular Module U3500 IMEI: 000000000000000 S/N: 000000000000000 28 mm ±0.2 18mm ±0.2 sample 打印要求 要求: 尺寸:28X18mm 材质:耐高温,两次过炉要求公差:+/-0.1mm FCC ID XHZU3500 Longsung Technology (Shanghai) CO., Ltd. Made in China U3500

Internal Photos

Page 2 Page 3

RF Exposure Info

Report No.: SA121002C10A 1 of 6 Report Format Version 5.0.0 Reference No.: 121002C10, 121002C32 RF EXPOSURE REPORT REPORT NO.: SA121002C10A MODEL NO.: U3500 FCC ID: XHZU3500 RECEIVED: Oct. 02, 2012 TESTED: Oct. 05 ~ Oct. 06, 2012 ISSUED: Oct. 22, 2012 APPLICANT: Longsung Technology(Shanghai) Co.Ltd ADDRESS: Building 5, 299 Bisheng Rd., Zhangjiang Hi-tech Park, Pudong, Shanghai 201204 P.R.China ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan ( R.O.C. ) TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. Report No.: SA121002C10A 2 of 6 Report Format Version 5.0.0 Reference No.: 121002C10, 121002C32 TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................................ 3 1. CERTIFICATION ............................................................................................................. 4 2. RF EXPOSURE ............................................................................................................... 5 2.1 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) ......................................... 5 2.2 MPE CALCULATION FORMULA .................................................................................... 5 2.3 CLASSIFICATION ........................................................................................................... 5 2.4 CALCULATION RESULT OF MAXIMUM CONDUCTED POWER .................................. 6 Report No.: SA121002C10A 3 of 6 Report Format Version 5.0.0 Reference No.: 121002C10, 121002C32 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED SA121002C10A Original release Oct. 22, 2012 Report No.: SA121002C10A 4 of 6 Report Format Version 5.0.0 Reference No.: 121002C10, 121002C32 1. CERTIFICATION PRODUCT: Module MODEL: U3500 BRAND: LongSung APPLICANT: Longsung Technology(Shanghai) Co.Ltd TESTED: Oct. 05 ~ Oct. 06, 2012 TEST SAMPLE: ENGINEERING SAMPLE STANDARDS: FCC Part 2 (Section 2.1091) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 The above equipment (Model: U3500) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY : , DATE :Oct. 22, 2012 Andrea Hsia / Specialist APPROVED BY : , DATE :Oct. 22, 2012 Anderson Chiu / Senior Engineer Report No.: SA121002C10A 5 of 6 Report Format Version 5.0.0 Reference No.: 121002C10, 121002C32 2. RF EXPOSURE 2.1 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 2.2 MPE CALCULATION FORMULA Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm 2.3 CLASSIFICATION The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. Report No.: SA121002C10A 6 of 6 Report Format Version 5.0.0 Reference No.: 121002C10, 121002C32 2.4 CALCULATION RESULT OF MAXIMUM CONDUCTED POWER FREQUENCY BAND (MHz) ERP (dBm) EIRP (dBm) DISTANCE (cm) POWER DENSITY (mW/cm 2 ) LIMIT (mW/cm 2 ) GSM: 824.2MHz ~ 848.8MHz 26.86 29.01 20 0.158 0.549 GPRS: 824.2MHz ~ 848.8MHz 21.16 23.31 20 0.043 0.550 WCDMA: 826.4MHz ~ 846.6MHz 16.70 18.85 20 0.015 0.551 FREQUENCY BAND (MHz) EIRP (dBm) DISTANCE (cm) POWER DENSITY (mW/cm 2 ) LIMIT (mW/cm 2 ) GSM: 1850.2MHz ~ 1909.8MHz 25.68 20 0.074 1 GPRS: 1850.2MHz ~ 1909.8MHz 22.28 20 0.034 1

Test Report

Report No.: RF121002C10 1 of 33 Report Format Version 5.0.0 FCC TEST REPORT (PART 22) REPORT NO.: RF121002C10 MODEL NO.: U3500 FCC ID: XHZU3500 RECEIVED: Oct. 02, 2012 TESTED: Oct. 05 ~ Oct. 06, 2012 ISSUED: Oct. 22, 2012 APPLICANT: Longsung Technology(Shanghai) Co.Ltd ADDRESS: Building 5, 299 Bisheng Rd., Zhangjiang Hi-tech Park, Pudong, Shanghai 201204 P.R.China ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan ( R.O.C. ) TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF121002C10 2 of 33 Report Format Version 5.0.0 TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................................ 3 1 CERTIFICATION .......................................................................................................... 4 2 SUMMARY OF TEST RESULTS .................................................................................. 5 2.1 MEASUREMENT UNCERTAINTY ............................................................................... 5 2.2 TEST SITE AND INSTRUMENTS ................................................................................ 6 3 GENERAL INFORMATION ........................................................................................... 7 3.1 GENERAL DESCRIPTION OF EUT ............................................................................. 7 3.2 CONFIGURATION OF SYSTEM UNDER TEST .......................................................... 8 3.3 DESCRIPTION OF SUPPORT UNITS ......................................................................... 8 3.4 TEST ITEM AND TEST CONFIGURATION ................................................................. 9 3.5 EUT OPERATING CONDITIONS ............................................................................... 10 3.6 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................ 10 4 TEST TYPES AND RESULTS .....................................................................................11 4.1 OUTPUT POWER MEASUREMENT ..........................................................................11 4.1.1 LIMITS OF OUTPUT POWER MEASUREMENT ........................................................11 4.1.2 TEST PROCEDURES .................................................................................................11 4.1.3 TEST SETUP ............................................................................................................. 12 4.1.4 TEST RESULTS ......................................................................................................... 13 4.2 FREQUENCY STABILITY MEASUREMENT ............................................................. 15 4.2.1 LIMITS OF FREQUENCY STABILIITY MEASUREMENT .......................................... 15 4.2.2 TEST PROCEDURE .................................................................................................. 15 4.2.3 TEST SETUP ............................................................................................................. 15 4.2.4 TEST RESULTS ......................................................................................................... 16 4.3 OCCUPIED BANDWIDTH MEASUREMENT ............................................................. 17 4.3.1 TEST PROCEDURES ................................................................................................ 17 4.3.2 TEST SETUP ............................................................................................................. 17 4.3.3 TEST RESULTS ......................................................................................................... 18 4.4 BAND EDGE MEASUREMENT ................................................................................. 19 4.4.1 LIMITS OF BAND EDGE MEASUREMENT ............................................................... 19 4.4.2 TEST SETUP ............................................................................................................. 19 4.4.3 TEST PROCEDURES ................................................................................................ 19 4.4.4 TEST RESULTS ......................................................................................................... 20 4.5 CONDUCTED SPURIOUS EMISSIONS .................................................................... 21 4.5.1 LIMITS OF CONDUCTED SPURIOUS EMISSIONS MEASUREMENT .................... 21 4.5.…

Text truncated - open the document above for the full version.

Test Setup Photos

1 PHOTOGRAPHS OF THE TEST CONFIGURATION (PART 22) RADIATED EMISSION TEST 2 (PART 24) RADIATED EMISSION TEST

Contact Information

Applicant

Jun Chen
[email protected]+86-21-50889688Fax: +86-21-50808118

Test Firm

Bureau Veritas CPS (H.K.) Ltd. Taoyuan BranchRichard Chen
[email protected]886-3-3183232Fax: 886 3 2115834

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
524E1.85 GHz - 1.91 GHz169.00 mW251KG7W0.03 ppm
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Single Modular Transmitter. Power listed is EIRP for part 24 and ERP for part 22. Approval is limited to OEM installation only and for licensed device. Compliance of this device in all final host configurations is the responsibility of the Grantee. This device is to be used only for mobile and fixed applications. The antenna(s) used for this transmitter must not exceed the gain of 3dBi, and must be installed to provide a separation distance of at least 20cm from all persons, and must not transmit simultaneously with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions and labeling requirements for finished products. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations.

Other Applications from LongSung Technology (Shanghai)Co.,Ltd.

HSDPA Module - FCC ID XHZU5501 - LongSung Technology (Shanghai)Co.,Ltd.
XHZU5501

HSDPA Module

Sep 11, 2012

Equipment Class

PCB - PCS Licensed Transmitter