FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. INGENICO/
  3. XKB-RX5CLWBT

XKB-RX5CLWBTSmart POS Terminal

INGENICO
Smart POS Terminal - FCC ID XKB-RX5CLWBT - INGENICO
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 28, 2023
Application Purpose
Original Equipment
Date of Application
Sep 27, 2023
Equipment Note
Smart POS Terminal
Frequency Range
2412.00000000 - 2462.00000000
Company
INGENICO
Country
France

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

AXIUM RX5000 User Guide www.ingenico.com 13-17 rue Pagès, 92150 Suresnes – France Banks and Acquirers International Holding SAS / 814 767 216 RCS Nanterre Copyright© 2022 Ingenico - Banks and Acquirers International Holding SAS All rights reserved 2 AXIUM RX5000 /0411 Contents 1. Introduction 4 2. Unpacking 5 3. Recommendations 6 3.1 Safety 6 3.2 Security of your terminal (tampering attempt detection) 7 3.3 Main Characteristics 8 3.3.1 Terminal 8 3.3.2 Power characteristics 9 3.3.3 Terminal Connectivity 10 3.3.4 WLAN (2.4 GHz / 5GHz) 10 3.3.5 BLUETOOTH 11 3.3.6 CONTACTLESS 12 3.4 Functional description 12 4. Installation & Connections 13 4.1 Positionning the terminals 13 4.2 Inserting SAM (Secure access module) and Micro SD 14 4.3 Connecting the terminal to the host 15 Copyright© 2022 Ingenico - Banks and Acquirers International Holding SAS All rights reserved 3 AXIUM RX5000 /0411 4.4 Setting the AXIUM RX5000 on the stand- pole adaptor 16 5. Daily use 19 5.1 Card reading 19 5.1.1 Swiping a card 19 5.1.2 Inserting a smart card 19 5.1.3 Reading a contactless card 20 5.2 Signature capture 21 5.3 Audio 21 5.4 Reboot AXIUM RX5000 21 5.5 Rear Camera(optional) 22 5.6 Shimmer detection(optional) 6. Maintenance 23 6.1 Cleaning of the terminal 23 6.2 Transport and storage 23 7. Standard 24 Copyright© 2022 Ingenico - Banks and Acquirers International Holding SAS All rights reserved 4 AXIUM RX5000 /0411 WARRANTY / SECURITY To benefit from the guarantee-related product, and to respect the security, we ask you to use only the recommended power supply. Maintenance operations should only be provided by an Ingenico authorized technician. Failure to comply with these instructions will void the manufacturer’s responsibility. This symbol indicates an important Warning. This symbol indicates a piece of advice. 1. Introduction Thank you for choosing an Ingenico payment terminal. We recommend you to read this user guide carefully: it gives you the necessary information about safety precautions, unpacking, installation and maintenance of your terminal. In all EU member states, operation of 5150-5350MHz is restricted to indoor use only. The product should be used indoor only. Copyright© 2022 Ingenico - Banks and Acquirers International Holding SAS All rights reserved 5 AXIUM RX5000 /0411 2. Unpacking According to the model, the following items are included in the packaging box (including optional accessories) : The terminal The box may also include the following items depending on your working configuration : The user guide The cable for connectivity The power supply unit and cable Copyright© 2022 Ingenico - Banks and Acquirers International Holding SAS All rights reserved 6 AXIUM RX5000 /0411 CAUTION Only use the power supply recommended with AXIUM RX5000. CAUTION Lithium battery cell The terminal is fitted with a lithium battery cell which is not accessible to the user. Only a qualified technician is authorized to open the unit and change this component. Risk of explosion if the battery is replaced by an incorrect type. Dispose of used battery according to the instructions. CAUTION An excessive acoustic pressure of headset can involve deafness! 3. Recommendations 3.1 Safety Power on/Power down - Emergency stop To power on or power down the terminal, connect or disconnect the power supply from the electric outlet. Electrical power supply network The electrical outlet must meet the following criteria: Must be installed near the equipment and easily accessible; Must meet standards and regulations in the country of use. Explosion areas Certain regulations restrict the use of radio equipment in chemical plants, fuel depots and any site where blasting is carried out. You are urged to comply with these regulations. The terminal shall be protected by a specially fitted and certified cover enabling use in proximity to a fuel pump. Connection of headset on audio jack Copyright© 2022 Ingenico - Banks and Acquirers International Holding SAS All rights reserved 7 AXIUM RX5000 /0411 3.2 Security of your terminal Your device fulfils current applicable PCI PTS security requirements. Upon receipt of your terminal you should check for signs of tampering of the equipment. It is strongly advised that these checks are performed regularly after receipt. You should check, for example: that the keypad is firmly in place; that there is no evidence of unusual wires that have been connected to any ports on your terminal or associated equipment, the chip card reader or any other part of your terminal. Such checks would provide warning of any unauthorised modifications to your terminal, and other suspicious behaviour of individuals that have access to your terminal. Your terminal detects any “tampered state”. In this state the terminal will repeatedly flash the message” Alert Irruption!” and further use of the terminal will not be possible. If you observe the “Alert Irruption!” message, you should contact the terminal helpdesk immediately. You are strongly advised to ensure that privileged access to your terminal is only granted to staff that have been independently verified as being trustworthy. The terminal must never be put in or left at a location where it could be stolen or replaced by another device as being trustworthy. WARNING We recommend to the customer to provide guidance to the cardholder as to avoid having his card close to any magnets on the device since the card may be damaged. There is one magnet in the stylus and another in its holder. Copyright© 2022 Ingenico - Banks and Acquirers International Holding SAS All rights reserved 8 AXIUM RX5000 /0411 Warranty label (on the bottom of the terminal) Copyright© 2022 Ingenico - Banks and Acquirers International Holding SAS All rights reserved 9 AXIUM RX5000 /0411 Weight (Poids, Gewicht) 274.5g(9.68oz) Size (dimensions, Maße) 176.5mm x 79mm x 37mm (withouPINshield) Display 4” WVGA (480 x 800 pixels) Touchscreen Capacitive Ambient temperature Max relative humidity -20°C, +70°C 90% …

Text truncated - open the document above for the full version.

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name FCC ID:XKB-RX5CLWBT AXIUM RX5000 We, applicant Company Name: INGENICO Address: 9 Avenue de la gare - Rovaltain TGV, BP25156,Valence Cedex 9,26958 ,France Phone: +330475842123 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-09-28 Printed Name of Signee: Nicolas Jacquemont Company: INGENICO Address: 9 Avenue de la gare - Rovaltain TGV, BP25156,Valence Cedex 9,26958 ,France Phone: +330475842123 Fax: +33475842350 Email: [email protected]

Attestation Statements

Local Representative Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(7), of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name FCC ID:XKB‐RX5CLWBT AXIUM RX5000 We hereby acknowledge as follows: i. both signees confirm that the point of contact accepts responsibility to act as a US‐ American Representative on behalf of the applicant ii. the point of contact provides the physical U.S. address and email as listed below iii. both parties maintain the requirements of this agreement for no less than one year af‐ ter the grantee has terminated all marketing and importation or the conclusion of any Commission‐related proceeding involving the equipment. Company Name: Ingenico Inc. INGENICO FRN: 0027093079 0018912279 Contact Name: Sriram seetharam Nicolas Jacquemont Signature Address: 101 Federal St,Suite 700, 7th flr, Boston,MA 02110 United States 9 Avenue de la gare ‐ Rovaltain TGV. BP25156.Valence Cedex 9,26958 France Phone: (781)738‐5682 +330475842123 Email: [email protected] m nicolas.jacquemontaingenico.com

Cover Letter(s)

INGENICO Add: 9 Avenue de la gare - Rovaltain TGV, BP25156,Valence Cedex 9,26958 ,France Te l : +330475842123 Fax: +33475842350 Mail: [email protected] Authority to Act as Agent Date: 2023-09-28 Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern: We, the undersigned, hereby authorize INGENICO of China Certification ICT Co.,Ltd (Dongguan) located in No.113,Pingkang Road,DalangTown,Dongguan,Guangdong,China to act on our behalf, as our agent, in the following matters related to the FCC approval of our products: report submittal, related correspondence, the signing of all documents relating to these matters, and any other lawful activity necessary to obtain such certification. Any act carried out by INGENICO of China Certification ICT Co.,Ltd (Dongguan) located in No.113,Pingkang Road,DalangTown,Dongguan,Guangdong,China within the scope of this authorization shall have the same effects as our own. We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. We also declare that the information provided to the FCC is true and correct to the best of our knowledge (47 CFR 2.911(d)) and we have been informed of the grantee responsibilities (47 CFR 2.909) with regard to certified equipment. Thank you, Agency Agreement Expiration Date:(Typically 12 months) Client’s signature Printed name: Nicolas Jacquemont Title: Certification Manager

Cover Letter(s)

Short Term Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and in accordance with the FCC Public notice dated June 15, 2004 (DA 04-1705) , we request short term confidentiality prior to marketing the device for the documentation of the following products: FCC ID Model name FCC ID:XKB-RX5CLWBT AXIUM RX5000 For the products listed above, we request short term confidentiality for all applicable exhibits as there are: • External photos • Internal photos • Test setup photos • User manual The above listed exhibits contain business sensitive information which we wish to keep confidential until the actual marketing of our device, that is planned for: Short term confidentiality release date: <180 days> If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-09-28 Printed Name of Signee: Nicolas Jacquemont Company: INGENICO Address: 9 Avenue de la gare - Rovaltain TGV, BP25156,Valence Cedex 9,26958 ,France Phone: +330475842123 Fax: +33475842350 Email: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name FCC ID:XKB-RX5CLWBT AXIUM RX5000 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-09-28 Printed Name of Signee: Nicolas Jacquemont Company: INGENICO Address: 9 Avenue de la gare - Rovaltain TGV, BP25156,Valence Cedex 9,26958 ,France Phone: +330475842123 Fax: +33475842350 Email: [email protected]

External Photos

EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS Page 1 of 10 Page 2 of 10 Page 3 of 10 Page 4 of 10 Page 5 of 10 Cable 1# Page 6 of 10 Cable 2# Cable 3# Page 7 of 10 Cable 4# Cable 5# Page 8 of 10 Adapter 1# Page 9 of 10 Adapter 2# Page 10 of 10 Adapter 3#

Internal Photos

China Certification ICT Co., Ltd (Dongguan) Report No.: CR230739799-INP Page 1 of 11 EXHIBIT C - EUT INTERNAL PHOTOGRAPHS China Certification ICT Co., Ltd (Dongguan) Report No.: CR230739799-INP Page 2 of 11 Buletooth&WIFI Antenna China Certification ICT Co., Ltd (Dongguan) Report No.: CR230739799-INP Page 3 of 11 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230739799-INP Page 4 of 11 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230739799-INP Page 5 of 11 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230739799-INP Page 6 of 11 NFC Antenna China Certification ICT Co., Ltd (Dongguan) Report No.: CR230739799-INP Page 7 of 11 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230739799-INP Page 8 of 11 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230739799-INP Page 9 of 11 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230739799-INP Page 10 of 11 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230739799-INP Page 11 of 11

RF Exposure Info

MAXIMUM PERMISSIBLE EXPOSURE EVALUATION REPORT Applicant: INGENICO Address: 9 Avenue de la gare - Rovaltain TGV, BP25156,Valence Cedex 9, 26958 , France FCC ID: XKB-RX5CLWBT Product Name: Smart POS Terminal Standard(s): 47 CFR §1.1310, 47 CFR §2.1091, 47 CFR §15.247(i),47 CFR §15.407(f) The above equipment has been tested and found compliant with the requirement of the relative standards by China Certification ICT Co., Ltd (Dongguan) Report Number: CR230739799-00G Date Of Issue: 2023/8/23 Reviewed By: Julie Tan Title: RF Engineer Approved By: Sun Zhong Title: Manager Test Laboratory: China Certification ICT Co., Ltd (Dongguan) No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China Tel: +86-769-82016888 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230739799-00G Page 2 of 6 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. The lab has been recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements, the CAB identifier: CN0123. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol “▲”. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk “★”. China Certification ICT Co., Ltd (Dongguan) Report No.: CR230739799-00G Page 3 of 6 DOCUMENT REVISION HISTORY Revision Number Report Number Description of Revision Date of Revision 1.0 CR230739799-00G Original Report 2023/8/23 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230739799-00G Page 4 of 6 1. SUMMARY OF TEST RESULTS Standard(s)/Rule(s) Description of Test Result §15.247 (i) & §1.1310 & §2.1091 Maximum Permissible Exposure (MPE) Compliant China Certification ICT Co., Ltd (Dongguan) Report No.: CR230739799-00G Page 5 of 6 2. RF EXPOSURE EVALUATION 2.1 §15.407 (f) & §1.1310 & §2.1091-Maximum Permissible Exposure (MPE) 2.1.1 Applicable Standard According to subpart 15.247(i)and subpart §1.1310, systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091) (B) Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f²) 30 30–300 27.5 0.073 0.2 30 300–1500 / / f/1500 30 1500–100,000 / / 1.0 30 f = frequency in MHz; * = Plane-wave equivalent power density; According to §1.1310 and §2.1091 RF exposure is calculated. 2.1.2 Calculation formula: Prediction of power density at the distance of the applicable MPE limit S = PG/4R² = power density (in appropriate units, e.g. mW/cm 2 ); P = power input to the antenna (in appropriate units, e.g., mW); G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain; R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); For simultaneously transmit system, the calculated power density should comply with: China Certification ICT Co., Ltd (Dongguan) Report No.: CR230739799-00G Page 6 of 6 2.1.3 Calculated Data: Mode Frequency (MHz) Antenna Gain Conducted output power including Tune- up Tolerance Evaluation Distance (cm) Power Density (mW/cm 2 ) MPE Limit (mW/cm 2 ) (dBi) (numeric)(dBm)(mW) Buletooth 2402-2480 1.02 1.26 11.514.13 20.00 0.004 1.0 2.4G Wifi 2412-2462 1.02 1.26 24 251.19 20.00 0.063 1.0 WIFI 5G 5150-5250 0.53 1.131863.120.00 0.014 1.0 5250-5350 0.53 1.131863.120.000.014 1.0 5470-5725 2.23 1.671863.120.000.021 1.0 5725-5850 1.56 1.431863.120.000.018 1.0 Note: The Conducted output power including Tune-up Tolerance was declared by manufacturer. Buletooth and WiFi can`t transmit simultaneously, 2.4G WiFi and 5G WiFi can`t transmit simultaneously Result: The device meet FCC MPE at 20 cm distance ===== END OF REPORT =====

Test Report

项目名称(ProjectName):RX5000-WIFI 天线型号(Antennamodel):ZTX-RX5000-WIFI-ANT A 物料编码(Itemnumber):E.03.00849 MPN码(MPN):B0680330D 日期(Date):2023-5-26 设计公司:福州中天迅通信技术有限公司 Designcompany : FuzhouzhongtianxxuncommunicationtechnologyCo.,Ltd 设计人员(designer):Xiaolianghu 电话(TEL):18120971171 测试人员(tester):Erdongwang 电话(TEL):18588455870 版本 Rev 日期 Date 状态 Status A12023-3-14 规格书制定。 Specifications. A22023-3-15 结构图纸更新。 Structuraldrawings updated. A32023-4-4 FPC外形,线路更新。 FPCshape,lineupdate. A42023-5-26 增加性能数据;FPC外形,线 路更新。 Increaseperformancedata; FPCshape,lineupdate. A52023-8-8 增加尺寸管控。 Increasedsizecontrol. 目录(Catalog) 1.名词解释(ExplanationofNouns).........................................................................................4 2.测试设备(Testequipment)........................................................................................................4 3.适用频段(Appliedfrequencyband)......................................................................................4 4.测试指标和数据图表(Testproject)......................................................................................5~12 4.1驻波图(VSWR).......................................................................................................................5 4.2无缘效率(Activetestdata)..........................................................................................6~7 4.33D辐射图(3dradiationmap).............................................................................................8 4.4有源数据(Activetestdata)...........................................................................................9~10 4.5匹配说明(Matchingcircuit)...........................................................................................11 4.6装配说明(Environmenttreatment)..............................................................................12 6.天线外形图(MechanicalSpecification)...............................................................................13 7.包装作业指导(Thepackingway).............................................................................................14~15 1名词解释(ExplanationofNouns) dBiDecibelrelativeisotropicantenna TxTransmitfrequency RxReceivefrequency TRPTotalRadiatedPower TISTotalIsotropicSensitivity VSWRVoltageStandingWaveRatio GSMGlobalServiceforMobilecommunication DCSDigitalCommunicationSystem CDMACodeDivisionMultipleAccess WCDMAWidebandCodeDivisionMultipleAccess 2测试设备(Testequipment) 矢量网络分析仪(Vectornetworkanalyzer)安捷伦8753E(Agilent8753E) 频谱分析仪(Frequencyanalyzer) 综合测试仪(General-purposetester)安捷伦8960E5515C 标准高性能无反射屏蔽暗室(Highperformanceno-reflectionshieldingdarkroom)ETS 8m*4m*4m 3适用频段(Appliedfrequencyband) FrequencyBandFrequency WIFI2400-2500MHz,5150-5850MHz。 4.测试指标和数据图表(Testindicatorsandfigures) 4.1驻波图(VSWR) 4.2无源效率(Activetestdata) (MHz)(dBi) (%) (MHz)(dBi) (%) 4.33D辐射图(3dradiationmap) 4.4有源数据(Activetestdata) 4.5匹配说明(Matchingspecification) 4.6装配图(Environmenttreatment) 5.天线外形图 D e s i g n e d m m G e n e r a l T o l e r a n c e A 5 1 : 1 福 州 中 天 迅 通 信 技 术 有 限 公 司 F u z h o u Z H O N G T I A N X U N C o m m u n i c a t i o n T e c h n o l o g y C o . , L t d ± 0 . 2 0 5 - 1 0 ± 0 . 3 0 1 0 - 2 0 ± 0 . 4 0 2 0 - 4 0 ± 0 . 5 0 4 0 > 设 计 : X i a o l i a n g h u C h e c k e d 审 核 : E r d o n g w a n g A p p r o v a l 批 准 : D a t e 日 期 : 2 0 2 3 . 8 . 8 S c a l e 比 例 : U n i t 单 位 : R e v 版 本 : 产 品 名 称 : W I F I P r o d u c t N a m e P r o j e c t N a m e 项 目 名 称 : R X 5 0 0 0 M a t e r i a l 材 料 : F P C P r o c e s s 工 艺 : T h i r d A n g l e 第 三 视 角 D r a w i n g N u m b e r M a t e r i a l C o d e 物 料 编 码 : E . 0 3 . 0 0 8 4 9 图 纸 编 号 : Z T X - Q R - R D - 0 1 3 ± 0 . 1 0 ± 0 . 1 5 ± 0 . 2 0 ± 0 . 2 5 A B D i m G r a d e 版 本 描 述 制 图 日 期 R e v D e s i g n e d D a t e D e s c r i p t i o n 备 注 : 1 、 图 中 所 标 注 尺 寸 为 重 点 管 控 尺 寸 , 试 产 或 模 具 样 需 全 部 测 量 , 带 " * " 的 尺 寸 为 I Q C 必 测 项 ; 未 注 公 差 参 照 图 框 内 公 差 表 管 控 ; T h e s i z e o f t h e s i z e o f t h e c o n t r o l s i z e , t h e t e s t p r o d u c t i o n o r t h e m o u l d s a m p l e s h o u l d b e m e a s u r e d , a n d t h e s i z e o f t h e m o l d i s r e q u i r e d f o r t h e i q c . T h e u n p a i d t o l e r a n c e i s c o n t r o l l e d b y t h e i n t e r n a l s y s t e m o f t h e p i c t u r e f r a m e ; 2 、 线 路 采 用 丝 印 工 艺 ; T h e l i n e a d o p t s t h e s i l k p r i n t i n g p r o c e s s ; 3 、 表 面 处 理 要 求 : 镀 镍 2 - 6 u m , 镀 金 0 . 0 3 u m ; S u r f a c e t r e a t m e n t r e q u i r e m e n t s : n i c k e l p l a t i n g 2 - 6 u m , g o l d p l a t i n g 0 . 0 3 u m ; 4 、 外 形 需 冲 切 光 滑 平 顺 、 且 不 能 冲 切 到 内 部 线 路 ; h e s h a p e s h o u l d b e b l a n k e d s m o o t h a n d s m o o t h , a n d c a n n o t b e b l a n k e d t o t h e i n t e r n a l l i n e ; 5 、 产 品 净 重 : 0 . 0 6 g , 毛 重 : 0 . 0 6 g ; P r o d u c t n e t w e i g h t : 0 . 0 6 g , g r o s s w e i g h t : 0 . 0 6 g ; 6 、 产 品 表 面 不 能 有 污 点 、 起 皱 、 露 铜 等 不 良 问 题 ; T h e s u r f a c e o f t h e p r o d u c t s h o u l d n o t b e s t a i n e d , w r i n k l e d , e x p o s e d c o p p e r a n d o t h e r b a d p r o b l e m s ; 7 、 镀 金 区 域 要 求 通 过 盐 雾 测 试 4 8 H ; T h e g o l d - p l a t e d a r e a r e q u i r e s t h e s a l t f o g t e s t 4 8 h 3 ; 8 、 油 墨 面 需 通 过 百 格 测 试 要 求 ; T h e i n k s u r f a c e m u s t p a s s t h e t e s t r e q u i r e m e n t s ; 9 、 所 有 物 料 需 满 足 R o H S 2 . 0 + H F 要 求 ; A l l m a t e r i a l s s h a l l m e e t t h e r e q u i r e m e n t s o f R o H S 2 . 0 + H F ; 1 0 、 包 装 方 式 : 散 装 出 货 ; P a c k i n g m e t h o d : b u l k s h i p m e n t ; 1 1 、 未 经 过 Z T X 公 司 确 认 , 材 料 不 能 随 意 更 改 ; W i t h o u t t h e c o n f i r m a t i o n o f Z T X , t h e m a t e r i a l c a n n o t b e c h a n g e d a t w i l l . Z T X - R X 5 0 0 0 - W I F I - A N T A 2 3 X X A 1 胡 小 良 X i a o l i a n g h u 2 0 2 3 . 3 . 1 4 首 次 发 行 。 F i r s t i s s u e . A 2 2 0 2 3 . 3 . 1 5 A 3 2 0 2 3 . 4 . 4 A 4 2 0 2 3 . 5 . 2 6 A 5 2 0 2 3 . 8 . 8 字 码 说 明 ( C o d e d e s c r i p t i o n ) : 2 3 X X 代 表 每 年 中 的 第 几 周 , 周 期 数 字 是 根 据 实 际 生 产 时 间 对 应 . R e p r e s e n t s t h e f i r s t f e w w e e k s o f t…

Text truncated - open the document above for the full version.

Test Report

TEST REPORT Applicant: INGENICO Address: 9 Avenue de la gare - Rovaltain TGV, BP25156,Valence Cedex 9, 26958 , France FCC ID: XKB-RX5CLWBT Product Name: Smart POS Terminal Standard(s): 47 CFR Part 15, Subpart C(15.247) ANSI C63.10-2013 KDB 558074 D01 15.247 Meas Guidance v05r02 The above equipment has been tested and found compliant with the requirement of the relative standards by China Certification ICT Co., Ltd (Dongguan) Report Number: CR230739799-00C Date Of Issue: 2023/8/8 Reviewed By: Julie Tan Title: RF Engineer Approved By: Sun Zhong Title: Manager Test Laboratory: China Certification ICT Co., Ltd (Dongguan) No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China Tel: +86-769-82016888 China Certification ICT Co., Ltd (Dongguan) Report No.: CR230739799-00C Page 2 of 34 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. The lab has been recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements, the CAB identifier: CN0123. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol “▲”. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk “★”. China Certification ICT Co., Ltd (Dongguan) Report No.: CR230739799-00C Page 3 of 34 CONTENTS T EST FACILITY .......................................................................................................................................... 2 DECLARATIONS .......................................................................................................................................... 2 DOCUMENT REVISION HISTORY .......................................................................................... 5 1. GENERAL INFORMATION .................................................................................................... 6 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................... 6 1.2 DESCRIPTION OF TEST CONFIGURATION ........................................................................................... 8 1.2.1 EUT Operation Condition: ............................................................................................................................. 8 1.2.2 Support Equipment List and Details .............................................................................................................. 8 1.2.3 Support Cable List and Details ...................................................................................................................... 8 1.2.4 Block Diagram of Test Setup ......................................................................................................................... 9 1.3 MEASUREMENT UNCERTAINTY ........................................................................................................ 10 2. SUMMARY OF TEST RESULTS .......................................................................................... 11 3. REQUIREMENTS AND TEST PROCEDURES .................................................................. 12 3.1 AC LINE CONDUCTED EMISSIONS .................................................................................................... 12 3.1.1 Applicable Standard ..................................................................................................................................... 12 3.1.2 EUT Setup.................................................................................................................................................... 13 3.1.3 EMI Test Receiver Setup ............................................................................................................................. 13 3.1.4 Test Procedure ............................................................................................................................................. 14 3.1.5 Corrected Amplitude & Margin Calculation ................................................................................................ 14 3.2 RADIATION SPURIOUS EMISSIONS .................................................................................................... 15 3.2.1 Applicable Standard .................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Nicolas Jacquemont(Certification Manager)
[email protected]+330475842123Fax: +33475842350

Test Firm

CHINA CERTIFICATION ICT CO., LTD (DONGGUAN)Tanie Ou
[email protected]0086 0769 86858888

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz236.00 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20MHz and 40MHz bandwidth mode for 2.4 GHz bands.

Other Applications from INGENICO

XKB-DX8AM

Smart POS Terminal

Aug 06, 2026

Equipment Class

PCB - PCS Licensed Transmitter
XKB-INGA02WF

Smart Module

Apr 03, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
XKB-INGA02WU

Smart Module

Mar 25, 2026

Equipment Class

DTS - Digital Transmission System
XKB-MOBEM3TOC

Mobile Payment Terminal

Dec 24, 2025

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Payment terminal - FCC ID XKB-RX9CLWBT - INGENICO
XKB-RX9CLWBT

Payment terminal

Aug 26, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX