Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Selesta Ingegneria S.p.A. RFIDat ‐ RFIDock/M ‐ RFIDock/S ‐ RFIDock/L ‐ RFIDock/SA ‐ USB/AL are products made in Italy by . Selesta Ingegneria S.p.A. – Via di Francia 28 – 16149 Genoa – Italy Tel: +39.010.60291 – Fax: +39.010.645454 8 – www.seling.it – www.rfidat.it SELESTA INGEGNERIA S.p.A. & INSTRUCTION MANUAL The RFIDat e RFIDock products are distribuited by: Instruction Manual – Ver. 1.4 ‐ 16/10/2009 Instruction Manual – Ver. 1.4 ‐ 16/10/2009 – pag. 12 of 12 FCC ID: XKC ‐ RFIDAT, XKC ‐ RFIDOCK For transmitters under FCC Part 15 Subpart C, clas s A or B classification is not applicable. The transmitter radiated emissions mu st meet the general limits of Part 15.209, and transmitter AC line ‐ conducted emissions must meet the requirements of Part 15.207. Both limits are identical to the class B limits, but there is no provision for meeting a more relaxed limit like class A as would be allowed under Part 15 Subpart B for unintentional radiators. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interf erence that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. Th ese limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: — Reorient or relocate the receiving antenna. — Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. — Consult the dealer or an experienced radio/TV technician for help. Selesta Ingegneria S.p.A. System components A. RFIDat: hand held terminal able to read in RF (radiofrequency mode) TAGs B. TAG: 125 Khz passive trasponder C. RFIDock/M: RFIDat modular docking station unit (up to 8 slots with 7 additional RFIDock/S ) for: • data transfer from RFIDat memory to RFIDock/M temporary memory (more then 8.000 readings) • transfer data to Personal Computer • RFIDat internal batteries charging and recharging D. RFIDock /L: RFIDat docking station unit (1 slot) for: • data transfer from RFIDat to RFIDock/L temporary memory (more then 8.000 readings) • transfer data to Personal Computer • RFIDat internal batteries charging and recharging in RF mode D. RFIDock /SA: unit to be used for: • RFIDat internal batteries charging External power unit RFIDock/AL (220 V ac / 12 V cc) is required E. USB/AL: adapter to connect and power RFIDock/M or RFIDock/L to/from a PC USB port F. RFIDock/AL: power supply unit 220 V ac / 12 V cc for RFIDock/M and RFIDock/SA units G. RFID USB Reader : pen for ID TAG code readi ng, connected to a PC USB port in keyboard emulation mode H. Ethernet ‐ 232 : RS232 / Ethernet converter Instruction Manual – Ver. 1.4 ‐ 16/10/2009 – pag. 2 of 12 Selesta Ingegneria S.p.A. Technical assistance To get further information and assistance , please contact the authorized local Reseller. Equipment and battery disposal End ‐ of ‐ life treatment of electric and electronic equipment (applicable in all the Countries of the European Union and in other European Countries with diversified collection systems). The products comply with the Directive 2002/96CE, related to disposal recycling of electric and electronic devices (RAAE): • This symbol applied on the product or on the wrapping indicates that it doesn't have to be considered as a normal domestic refusal, but that it must be delivered to collection point suitable for the recycling of electric and electronic devices. For more detailed information on the recycling of this product, please contact the City office, the local service of refusal disposal or the seller. Not respecting these dispositions can involve administrative sanctions and penalties. Product components are conform to th e Directive 2002/95/CE, related to the restrictions of use of certain dangero us substances in the electric and electronic equipments (RoHS), therefor e they don't contain any harmful or dangerous substances in percentages higher than the tolerated limits. Instruction Manual – Ver. 1.4 ‐ 16/10/2009 – pag. 11 of 12 Selesta Ingegneria S.p.A. Attention : don't expose the RFIDat and RFIDock/M/S/AL products to heat sources, direct solar light, humidity or rain. Avoid immersion in water or other liquids. Don't tamper with pierce or burn the system components. Don't leave the system components unguarded and to the reach of children or animals. Attention : in case of possible operational anomalies or accidental damages to the system components, immediately interrupt its use and turn to the local authorized Retailer to ask for assistance. Warranty The products are warranted against any defect in material and workmanship, under normal use, for the designed warranty period. The warranty becomes effective from the date of shipment. In the event these products are found to be defectives within the warranty period, its will be repaired or replaced. The warranty non cover wear and tear on covers or housing and batteries. The warranty is void if the products : • have been opened • have been repaired, modified or altered or had work performed by not authorized service centre. • was subjected to abuse, neglect, electrical fault, improper packaging, accident or acts of nature • were…
Text truncated - open the document above for the full version.
Micro Controller Micro Controller Buffer Rectfier Amplifier 16.0Mhz 16.0Mhz 125 Khz 125 Khz Amplifier Modulator 1.953 Khz Link RF -+ -+
FCC ID: XKC-RFIDAT Made in Italy S/N 1234567c RoHS Ni-Mh
ST_RFIDat_ENG _V11A 02/10/08 . Selesta Ingegneria S.p.A. • Via di Francia 28 • 16149 Genova • Tel: +39.010.60291 • Fax: +39.010.6454548 • www.seling.it Genova • Milano • Roma • Torino – Vicenza – Bologna - Potenza pag. 1 di 3 Description RFIDat is a small self‐powered portable reader that can intentionally read, via RF (Radio Frequency) mode, passive "TAGs", also of very reduced dimensions and low cost. RFIDat, is convenient, reliable, easy and comfortable to use. RFIDat provides many possibilities of use in the world of data collection and time management. RFIDat is the ideal and competitive tool when it is necessary to attribute working time to Job Orders or Cost Centers when people mobility is very frequent and it is not possible to use other equipments such as Time&Attendance terminals or plant terminals. The TAG (transponders), as small as a coin, can be placed, according to needs, in specific work places or on specific objects. Possibile uses As an example, RFIDat can be used by Enterprises / Public Utilities for: ‐ attribution of performances /services to Cost Centers; ‐ performance accounting on Job Orders (manufacturing enterprises, building yards, shipyards, auto body shops, workshops, etc.); ‐ accounting of the performance of temporary employment Companies; Proxi “tag” portable reader and data unloading station TAG ST_RFIDat_ENG _V11A 02/10/08 . Selesta Ingegneria S.p.A. • Via di Francia 28 • 16149 Genova • Tel: +39.010.60291 • Fax: +39.010.6454548 • www.seling.it Genova • Milano • Roma • Torino – Vicenza – Bologna - Potenza pag. 2 di 3 ‐ accounting of the performance of Service Enterprises / Corporate Bodies (maintenance, assistance centers, social cooperatives, cleaning, etc.); ‐ attribution of performances /consulting services to professional Offices (lawyers, advisors, etc.); ‐ accounting of services provided by Vigilance Companies. Operations One RFIDat unit is given to each person and configured with his name and personal code. Whenever the person approaches the RFIDat to a TAG and press the specific key, the TAG univocal code is read; instantly, inside the memory of RFIDat, a transaction that contains the person's code, day, month, year, time, minutes and code of the TAG just read is generated. The RFIDock unit is the holding station that has the double function of managing the communications and of recharging the batteries of the RFIDat units. Also the batteries are recharged in radio frequency. Example of configuration The software product RFICom is also supplied with RFIDat and RFIDock. It allows to manage the communications and the configuration of the RFIDat, to query the transactions and to export data towards other management system. The description of the functional characteristics of RFICom is shown in the specific technical sheet. RFIDat technical characteristics ‐ RFID TAG: 125Khz, em4102 compatible ‐ Storage capacity: 8.000 transactions: ID reader, ID tag, date, time and minutes ‐ Automatic Daylight Savings Time ‐ Data transmission: wireless (by induction), two‐way ‐ Duration of batteries: 60 days minimum, or 3.000 readings ‐ Batteries recharge: contactless (by induction) ‐ Clock precision: max. 10 sec/month (from 20° to 30°C); typical 1 min/year (at 25°C) ‐ Display: graphic 128 x 64 with visualization: time and date ‐ assigned name ‐ number of read tags ‐ battery status ‐ Key: tactile backlighted for power on and reading TAG ‐ Dimensions: 60 x 45 x 15 mm. ‐ Reading signal: buzzer and blue led in the key ‐ Operations environment: 0° ‐ 50°C without condensation ‐ Mechanical resistance: 50 cm fall on concrete ST_RFIDat_ENG _V11A 02/10/08 . Selesta Ingegneria S.p.A. • Via di Francia 28 • 16149 Genova • Tel: +39.010.60291 • Fax: +39.010.6454548 • www.seling.it Genova • Milano • Roma • Torino – Vicenza – Bologna - Potenza pag. 3 di 3 RFIDock technical characteristics ‐ Connections: serial Rs232 / USB, 200 cm cable ‐ Power supply: external, 12Vdc ‐ Base: with 1 ‐ 2 ‐ 4 ‐ 8 compartments modularity ‐ Signalling leds n.4: • power supply • presence of RFIDat reader • batteries under recharge • data transmission in progress ‐ Options: ‐ Ethernet interface ‐ GSM module (available: 4 th Q 2008) RFIDat - RFIDock - RFICom are products of Selesta Ingegneria Selesta Ingegneria reserves the right of modifying the content of this document
6001 1/2 VCC C8 R4 C2 Q5 C4 L1 U3 4 5 1213 321514111076 89 16 1 VSS VCC PA3PA2 PB0PB1PB2PB3PB4PB5PB6PB7 PA5PA4PA1PA0 C6 R8 C10 Q2 R11 C12 TP7 1 R3 TP9 1 TP1 1 D1B C7 Y1 D2 R2 R6 TP6 1 R15 -+ U1A 32 1 84 D1A t RT1 C9 R1 C1 TP4 1 TP2 1 TP8 1 -+ U1B 56 7 C3 Q3 C5 R7 R16 R10 C13 TP5 1 C11 SW1 R9 Q1 R5 TP3 1 Q4 CEVCCDISP Buz2-Batt SCLSDD Buz1 C-D +Batt+Batt GND SDAINT 6001 2/2 Q11 C15 U5 54 231 VOUT ADJ VINSHDN GND C17 C24 TP13 1 Q7 Q10 C23 C19 Q8 TP10 1 C18 U6 10 6 2 7 5 1 4 CkEn GND CkOut INT SDA VCC SCL R13 C16 R14 R12 Q9 U4 12 4 56 7 8 23 A0A1 GND SDASCL WP VCC A1A2 Q6 C14 J1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 TP11 1 C22 TP12 1 C21 C20 SDDC-DSCLDISPCESDAVCCGNDINT Lista Componenti RfiDat Ver 1.2.1 26/05/2008: Qt Descizione Codice,Alternativa _______________________________________________________________________ 1 Ds1 Display LCD 128x64 POWERTIP PE12864- D-GFC00085B-0 1 Bt1 Batteria NiMh 3x1/3AAA 3.6V 170mAh 3ERH-170 1 Circuito Lettore 6001 _______________________________________________________________________ Lista Componenti Codice 6001 Vers. 1.0 Qt Ref Descizione Codice,Alternativa _______________________________________________________________________ 1 C1 Condensatore Y5V 10nF C0805-103 2 C2,C9 Condensatore X7R 10% 100pF C0805-101 3 C3,C10,C11 Condensatore X7R 5% 2.2 nF 100V C0805-222 1 C4 Condensatore X7R 10% 1nF C0805-102 8 C5,C7,C15, C16,C17,C19, C20,C24 Condensatore Y5V 100nF C0805-104 7 C6,C8,C14,C18, C21,C22,C23 Condensatore Y5V 1uF C0805-105 2 C13,C12 Condensatore NP0 5% 22pF C0805-220 1 D1B,D1A Diodo Dual SOT143 BAV23 Philips 1 D2 LED 0805 BLu 1 L1 Induttore 8x8 680 uH TLS0808-681 TDK 4 Q3,Q4,Q5,Q11 Power Mosfet ChN SOT23 BSS123LT1 7 Q1,Q2,Q6,Q7, Q8,Q9,Q10 Power Mosfet ChP SOT23 BSS84LT1 1 RT1 4 R1,R3,R5,R8 Resistenza 1/8W 5% 47k R0805-473 1 R2 Resistenza 1/8W 5% 10K R0805-103 2 R4,R16 Resistenza 1/8W 5% 100K R0805-104 1 R6 Resistenza 1/8W 5% 470K R0805-474 2 R14,R7 Resistenza 1/8W 5% 4K7 R0805-472 1 R9 Resistenza 1/8W 5% 22R R0805-220 1 R10 Resistenza 1/8W 5% 270K R0805-274 1 R11 Resistenza 1/8W 5% 10M R0805-106 1 R12 Resistenza 1/8W 5% 330K R0805-334 1 R13 Resistenza 1/8W 5% 270K R0805-274 1 R15 Resistenza 1/8W 5% 330R R0805-331 1 SW1 Pulsante SMD 2 Pin H4.3 KTH33043 1 U1 OpAmp Dual SO8 LPV358 1 U2 Microcontrollore MC68HC908QB8 Frescale MC68HC908QB8DTE 1 U4 Memoria EeProm I2C SO8,SOIC 24LC512 1 U5 Regolatore Tensione ThinSOT LTC1964ES5-SD 1 U6 RelTime Clock I2C Micro Crystal RV-8564-C2B 1 Y1 Quarzo SMD SX4 5x3.2 SX5032-16M 1 Bz1 Buzzer Piezo SMD PKLC1212E4001-R1 1 6001 Circuito Stampato FR4B-1.6-35 Pag. 1/1
Report Number 3176546BOX-001 Page 1 of 18 EMISSIONS TEST REPORT Report Number: 3176546BOX-001 Project Number: 3176546 Testing performed on the RFIDat Handheld RFID Reader & RFIDock Modular Docking Station Models: RFIDat & RFIDock FCC IDs: XKC-RFIDAT & XKC-RFIDOCK To CFR47 “Telecommunications” FCC Part 15 Subpart C “Intentional Radiators” 15.209 For PGA Test Performed by: Test Authorized by: Intertek – ETL SEMKO 70 Codman Hill Road Boxborough, MA 01719 Intertek Italy SRL Via Principe di Udine 33030 Campoformido Italy Prepared by: Date: 12/02/2009 Nicholas Abbondante Reviewed by: Date: 12/11/09 Jeff Goulet This report is for the exclusive use of Intertek’s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek’s responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. This report must not be used to claim product endorsement by A2LA, NIST nor any other agency of the U.S. Government. Report Number 3176546BOX-001 Page 2 of 18 1.0 Job Description 1.1 Client Information This EUT has been tested at the request of: Company: Intertek Italy SRL Via Principe di Udine 33030 Campoformido Italy Contact: Arianna Fogar Telephone: Fax: Email: 39 432 653-411 39 432 653-499 [email protected] 1.2 Equipment Under Test Equipment Type: RFIDat Handheld RFID Reader & RFIDock Modular Docking Station Model Number(s): RFIDat & RFIDock Serial number(s): 10240803111 (RFIDat) BOX0811211651-001 (RFIDock, Intertek Assigned) FCC IDs: XKC-RFIDAT (model: RFIDat) & XKC-RFIDOCK (model: RFIDock) Manufacturer: PGA EUT receive date: 11/21/2008 & 03/20/2009 EUT received condition: Prototype in Good Condition Test dates: 12/23/2009 to 12/24/2009, 03/23/2009 1.3 Test Plan Reference: Tested according to the standards listed and using the guidance of ANSI C63.4:2003. 1.4 Test Configuration 1.4.1 Block Diagram RFIDat RFIDock (data dock) DC Power AC/DC Power Supply AC Power Report Number 3176546BOX-001 Page 3 of 18 1.4.2. Cables: Cable Shielding Connector Length (m) Qty. DC Power None Metal/360 Jack 1.8 1 1.4.3. Support Equipment: Name: Model No.: Serial No.: 12V AC/DC Power Supply 0299-120133 BOX0903101127-001 1.5 Mode(s) of Operation: The RFIDat is battery powered. During testing, the RFIDat was placed in the RFIDock (data dock). While the RFIDat was placed in the RFIDock, the pair was transmitting nearly continuously. 1.6 Floor Standing Equipment: Applicable: Not Applicable: X Report Number 3176546BOX-001 Page 4 of 18 2.0 Test Summary TEST STANDARD RESULTS FCC Part 15 Subpart C 15.209 SUB-TEST TEST PARAMETER COMMENT Radiated Spurious Emissions & Fundamental Field Strength FCC 15.209 The fundamental field strength at 125 kHz must not exceed 105.7 dBuV/m at a distance of 3 meters. Spurious emissions must not exceed the field strength limits of 15.209 at a distance of 3 meters. Pass Occupied Bandwidth FCC 15.215 There is no limit on occupied bandwidth. Pass Duty Cycle FCC 15.35 There is no limit on duty cycle. Pass Conducted Emissions FCC 15.207 AC Line-Conducted Emissions must not exceed limits for Part 15 Subpart C 15.207. Pass Notes: The EUT is a transmitter which transmits at 125 kHz. REVISION SUMMARY – The following changes have been made to this Report: Date Project No. Project Handler Page(s) Item Description of Change 12/02/2009 3176546 Nicholas Abbondante 2-4, 8, 12- 15 Report Merge Added results for Occupied Bandwidth and Duty Cycle tests from report 3169546BOX-001. 12/02/2009 3176546 Nicholas Abbondante 1-3, 8-9, 12, 14, 16- 17 Model and Serial Numbers Updated Model and Serial numbers to reference both items tested, the RFIDat and RFIDock 12/02/2009 3176546 Nicholas Abbondante 1-2, 5-7 Report update Added FCCIDs, updated sample calculation, measurement uncertainty and site description Report Number 3176546BOX-001 Page 5 of 18 3.0 Sample Calculations The field strength is calculated by adding the Antenna Factor and Cable Factor, and subtracting the Amplifier Gain (if any) from the measured reading. The basic equation with a sample calculation is as follows: FS = RA + AF + CF - AG Where FS = Field Strength in dBμV/m RA = Receiver Amplitude (including preamplifier) in dBμV CF = Cable Attenuation Factor in dB AF = Antenna Factor in dB AG = Amplifier Gain in dB In the following table(s), the reading shown on the data table reflects the preamplifier gain. An example for the calculations in the following table is as follows. Assume a receiver reading of 52.0 dBμV is obtained. The antenna factor of 7.4 dB and cable factor of 1.6 dB is added. The amplifier gain of 29 dB is subtracted, giving a field strength of 32 dBμV/m. This value in dBμV/m was converted to its corresponding level in μV/m. RA = 52.0 dBμV AF = 7.4 dB/m CF = 1.6 dB AG = 29.0 dB FS = 32 dBμV/m Level in μV/m = [10( 32 dBμV/m)/20] = 39.8 μV/m The following is how net line-conducted readings were determined: NF = RF + LF + CF + AF Where NF = Net Reading in dBμV RF = Reading from receiver in dBμV LF = LISN Correction Factor in dB CF = Cable Correction Factor in dB AF = Attenuator Loss Factor in dB To convert from dBμV to μV or mV the following was used: UF = 10 (NF / 20) where UF = Net Reading in μV NF = Net Reading in dBμV Example: NF = RF + LF + CF + AF = 28.5 + 0.2 + 0.4 + 20.0 = 49.1 dBμV UF = 10 (49.1 dBμV / 20) = 285.1 μV/m Report Number 317…
Text truncated - open the document above for the full version.
Radiated Emissions Setup Photos Radiated Emissions Setup Photos Conducted Emissions Setup Photo
Via Di Francia 28 · Genova · Italy
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.125 MHz - 0.125 MHz | - |

RFIDock
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified