FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Teko Telecom Srl/
  3. XM2LOWPOWERL

XM2LOWPOWERLOPTICAL SYSTEMS

Teko Telecom Srl
OPTICAL SYSTEMS - FCC ID XM2LOWPOWERL - Teko Telecom Srl
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Aug 10, 2010
Application Purpose
Original Equipment
Date of Application
Jul 18, 2010
Equipment Note
OPTICAL SYSTEMS
Frequency Range
935.00000000 - 940.00000000
Company
Teko Telecom Srl
Country
Italy

Documents & Files

Select a file to view

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Operational Description

↗
↗

Parts List/Tune Up Info

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Teko Telecom S.p.A. Via Meucci, 24/a Castel S. Pietro Terme (BO) – Italy Tel +39 051 69 46 811 – Fax +39 051 94 84 73 P.IVA/VAT IT 02186561201 – Reg. Imprese di Bologna n. 02186561201 Capitale sociale Euro 660.000,00 i.v. – Soggetta a direzione e coordinamento di MetaSystem Group S.p.A. Società con Sistema di Qualità ed Ambiente certificato – ISO 9001:2000, ISO 14001:2004 Castel San Pietro Terme, 03 May 2010 Nemko Canada Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 FCC ID: XM2LOWPOWERL Product Name: Optical Systems Remote Unit with Master Device Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: ∑ Schematic diagrams ∑ Block diagram ∑ User manual ∑ Tune up information ∑ Internal photos These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Moreover, internal photos have to be held confidential because non-consumer device is not accessible by the general public (device installed in Restricted Area Location) and it is only serviceable by the licensee. User’s manual have to be held confidential because it is very technical and only available to designated technicians by the licensee. Dated 03 May 2010 By: ALESSANDRO BRUNELLI Signature Printed Title: CERTIFICATION ENGINEER On behalf of : TEKO TELECOM Telephone: +39 051 6946811

Cover Letter(s)

Teko Telecom S.p.A. Via Meucci, 24/a Castel S. Pietro Terme (BO) – Italy Tel +39 051 69 46 811 – Fax +39 051 94 84 73 P.IVA/VAT IT 02186561201 – Reg. Imprese di Bologna n. 02186561201 Capitale sociale Euro 660.000,00 i.v. – Soggetta a direzione e coordinamento di MetaSystem Group S.p.A. Società con Sistema di Qualità ed Ambiente certificato – ISO 9001:2000, ISO 14001:2004 Castel San Pietro Terme, 03 May 2010 Nemko Canada Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 FCC ID: XM2LOWPOWERL Product Name: Optical Systems Remote Unit with Master Device RESTRICTED ACCESS OF EQUIPMENT AND DOCUMENTATION NOTICE This Restricted Access of Equipment and Documentation Notice is to inform the licensee that access to equipment and related documentation supplied by Teko Telecom S.p.A. is to be restricted to only authorized users by means to ensure the security of the equipment and confidentiality of related documentation at all times, and only designated professionals shall be allowed to maintain or service the equipment. Tampering with the internal parts of these non-consumer type devices by removal of external covers can damage or destroy the equipment, therefore it is necessary that the device be kept in a restricted location, and inaccessible to the general public. This notice includes, but is not limited to, Schematic, Block Diagrams, User Manual, Tune Up information, and Internal Photos. Dated 03 May 2010 By: ALESSANDRO BRUNELLI Signature Printed Title: CERTIFICATION ENGINEER On behalf of : TEKO TELECOM Telephone: +39 051 6946811

Cover Letter(s)

Teko Telecom S.p.A. Via Meucci, 24/a Castel S. Pietro Terme (BO) – Italy Tel +39 051 69 46 811 – Fax +39 051 94 84 73 P.IVA/VAT IT 02186561201 – Reg. Imprese di Bologna n. 02186561201 Capitale sociale Euro 660.000,00 i.v. – Soggetta a direzione e coordinamento di MetaSystem Group S.p.A. Società con Sistema di Qualità ed Ambiente certificato – ISO 9001:2000, ISO 14001:2004 Castel San Pietro Terme, 03 May 2010 Nemko Canada Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 Attn: Director of Certification Authority to Act as Agent FCC On our behalf, I appoint Nemko Spa – via del Carroccio n. 4, Biassono (MB) Italy to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko Canada Inc, still resides with (applicant name and address). Dated 03 May 2010 By: ALESSANDRO BRUNELLI Signature Printed Title: CERTIFICATION ENGINEER On behalf of : TEKO TELECOM Telephone: +39 051 6946811

Cover Letter(s)

Teko Telecom S.p.A. Via Meucci, 24/a Castel S. Pietro Terme (BO) – Italy Tel +39 051 69 46 811 – Fax +39 051 94 84 73 P.IVA/VAT IT 02186561201 – Reg. Imprese di Bologna n. 02186561201 Capitale sociale Euro 660.000,00 i.v. – Soggetta a direzione e coordinamento di MetaSystem Group S.p.A. Società con Sistema di Qualità ed Ambiente certificato – ISO 9001:2000, ISO 14001:2004 REMOTE UNIT LOW POWER VARIANTS Commercial name Description REMOTE UNIT LOW POWER TRU Teko Telecom Remote Unit xxxxx = Operating band: 7S: SMR700 (UL: 698-716+776-787MHz) DL: 728-757MHz) 7P: Public Safety 700 (DL: 763-775MHz; UL: 793-805MHz) 8S: SMR800 (DL: 851-869MHz; UL: 806-824MHz) 8A: AMPS (DL: 869-894MHz; UL: 824-849MHz) 9S: SMR900 (DL: 935-941MHz; UL: 896-902MHz) 19: PCS1900 (DL: 1930-1995MHz; UL: 1850-1915MHz) AW: AWS2100 (DL: 2110-2155MHz; UL: 1710-1755MHz) and combination of these c = RF Connector: W: wideband D: duplexed B: bi duplexed N: no duplexed S: single connector L = L: low power TRUxxxxxcL/zz-kkkj zz = Power supply: AC: Power Supply: 85-264Vac, 50-60Hz 48: Power Supply: 36-72Vdc Teko Telecom S.p.A. Via Meucci, 24/a Castel S. Pietro Terme (BO) – Italy Tel +39 051 69 46 811 – Fax +39 051 94 84 73 P.IVA/VAT IT 02186561201 – Reg. Imprese di Bologna n. 02186561201 Capitale sociale Euro 660.000,00 i.v. – Soggetta a direzione e coordinamento di MetaSystem Group S.p.A. Società con Sistema di Qualità ed Ambiente certificato – ISO 9001:2000, ISO 14001:2004 kkk = Laser version: Without option: NO WDM Termocontrolled laser version: W21:  = 1560,61nm W23:  = 1558,98nm W25:  = 1557,36nm W27:  = 1555,75nm W29:  = 1554,13nm W31:  = 1552,52nm W:  = 1550,92nm W35:  = 1549,32nm W37:  = 1547,72nm No termocontrolled laser version: M11:  = 1470 ± 3 nm M12:  = 1490 ± 3 nm M13:  = 1510 ± 3 nm M14:  = 1530 ± 3 nm W :  = 1550 ± 3 nm (standard version) M16:  = 1570 ± 3 nm M17:  = 1590 ± 3 nm M18:  = 1610 ± 3 nm j = Optical connector: S: SC-APC E: E-2000

External Photos

Teko Telecom S.p.A. Via Meucci, 24/a Castel S. Pietro Terme (BO) – Italy Tel +39 051 69 46 811 – Fax +39 051 94 84 73 P.IVA/VAT IT 02186561201 – Reg. Imprese di Bologna n. 02186561201 Capitale sociale Euro 660.000,00 i.v. – Soggetta a direzione e coordinamento di MetaSystem Group S.p.A. Società con Sistema di Qualità ed Ambiente certificato – ISO 9001:2000, ISO 14001:2004 EXTERNAL PHOTO REMOTE UNIT LOW POWER TRU7S8A19WL/AC-WS TRU7S8AAWWL/AC-WS TRU8S9S19WL/AC-WS Teko Telecom S.p.A. Via Meucci, 24/a Castel S. Pietro Terme (BO) – Italy Tel +39 051 69 46 811 – Fax +39 051 94 84 73 P.IVA/VAT IT 02186561201 – Reg. Imprese di Bologna n. 02186561201 Capitale sociale Euro 660.000,00 i.v. – Soggetta a direzione e coordinamento di MetaSystem Group S.p.A. Società con Sistema di Qualità ed Ambiente certificato – ISO 9001:2000, ISO 14001:2004 Teko Telecom S.p.A. Via Meucci, 24/a Castel S. Pietro Terme (BO) – Italy Tel +39 051 69 46 811 – Fax +39 051 94 84 73 P.IVA/VAT IT 02186561201 – Reg. Imprese di Bologna n. 02186561201 Capitale sociale Euro 660.000,00 i.v. – Soggetta a direzione e coordinamento di MetaSystem Group S.p.A. Società con Sistema di Qualità ed Ambiente certificato – ISO 9001:2000, ISO 14001:2004 Teko Telecom S.p.A. Via Meucci, 24/a Castel S. Pietro Terme (BO) – Italy Tel +39 051 69 46 811 – Fax +39 051 94 84 73 P.IVA/VAT IT 02186561201 – Reg. Imprese di Bologna n. 02186561201 Capitale sociale Euro 660.000,00 i.v. – Soggetta a direzione e coordinamento di MetaSystem Group S.p.A. Società con Sistema di Qualità ed Ambiente certificato – ISO 9001:2000, ISO 14001:2004 Teko Telecom S.p.A. Via Meucci, 24/a Castel S. Pietro Terme (BO) – Italy Tel +39 051 69 46 811 – Fax +39 051 94 84 73 P.IVA/VAT IT 02186561201 – Reg. Imprese di Bologna n. 02186561201 Capitale sociale Euro 660.000,00 i.v. – Soggetta a direzione e coordinamento di MetaSystem Group S.p.A. Società con Sistema di Qualità ed Ambiente certificato – ISO 9001:2000, ISO 14001:2004

ID Label/Location Info

CLASS 1 LASER PRODUCT AC MAINS (100-240V∼; 50-60Hz; 1.5A) OPTICAL DL/UL WDM RF PORT RS232 LED EXT IN EXT OUT 0 I 824 ÷ 894MHz 1850 ÷ 1995MHz 698 ÷ 787MHz TRU7S8A19WL/AC-WS R CUS TEKO TELECOM MODEL: TRU7S8A19WL/AC-WS FCC ID: XM2LOWPOWERL CLASS 1 LASER PRODUCT AC MAINS (100-240V∼; 50-60Hz; 1.5A) OPTICAL DL/UL WDM RF PORT RS232 LED EXT IN EXT OUT 0 I 824 ÷ 894MHz 1710 ÷ 2155MHz 698 ÷ 787MHz TRU7S8AAWWL/AC-WS R CUS TEKO TELECOM MODEL: TRU7S8AAWWL/AC-WS FCC ID: XM2LOWPOWERL CLASS 1 LASER PRODUCT AC MAINS (100-240V∼; 50-60Hz; 1.5A) OPTICAL DL/UL WDM RF PORT RS232 LED EXT IN EXT OUT 0 I 896 ÷ 941MHz 1850 ÷ 1995MHz 806 ÷ 869MHz TRU8S9S19WL/AC-WS R CUS TEKO TELECOM MODEL: TRU8S9S19WL/AC-WS FCC ID: XM2LOWPOWERL

Operational Description

www.tekotelecom.it www.tekotelecom.it Going further, together Doc ID Number 91 080 0780 - Rel. 03 english Teko Telecom Optical Systems 1.General Description1.General Description www.tekotelecom.it www.tekotelecom.it Going further, together Teko Telecom Optical Systems Doc ID Number 91 080 0780 - Rel. 03 page 8 english Teko Telecom Optical Systems - General Description1. Teko Telecom Optical Systems are flexible multi-band multi-operator modular systems that provide both indoor and outdoor cellular coverage in shadow areas -where RF signal is not available- or capacity in hot spots -where the operators want a dedicated coverage. They are based on the Radio over Fibre technology, which enables radio signals transmission over optical fibres. REMOTE UNITS Passive POI Subracks RF Interface Optical Subracks Optical Interface and Supervision COAXIAL CABLE (RF SIGNAL) BTS, Node B or Repeater SIGNAL SOURCE SINGLE MODE OPTICAL FIBRE (OPTICAL SIGNAL) COAXIAL CABLE RF SIGNAL COAXIAL CABLE (RF SIGNAL) COAXIAL CABLE (RF SIGNAL) RF SIGNAL Supervision Module MASTER UNIT SINGLE MODE OPTICAL FIBRE (OPTICAL SIGNAL) SINGLE MODE OPTICAL FIBRE (OPTICAL SIGNAL) Each Optical System is made up of two main parts, Master Unit and Remote Units, connected via single mode optical fibres (SMR 9/125). Master Unit is a rack-based modular equipment which provides both RF connection towards the signal source (one or more BTSs, Node Bs or repeaters) and the optical interface towards Remote Units. It also hosts the Supervision Module for the management of the whole System. Remote Units distribute capacity or extend coverage into different locations at distances up to 20km (12.4miles) from the Master Unit. They can be Single, Dual or Tri-band with four different RF power classes: Very High, High, Medium and Low. A single Master Unit can drive up to 144 Remote Units. Various network structures can be supported by the Master Unit: the Remote Units of the same Optical System can be deployed with a point-to-point connection (star-configuration - using one fiber optic per Remote Unit) or with cascading of up to 5 Remote Units using a single fibre and optimized optical couplers. www.tekotelecom.it www.tekotelecom.it Going further, together Teko Telecom Optical Systems Doc ID Number 91 080 0780 - Rel. 03 page 9 english Operating Principle1.1 Teko Telecom Optical Systems are based on the Radio over Fiber Concept: in Downlink RF signals are converted into optical signals in the Fiber Optic Transmitter modules of the Master Unit and then they are propagated through optical fibre distribution to Remote Units. In the Fiber Optic Receiver of each Remote Unit, the optical signal is then converted back into an RF signal that is amplified and transmitted to mobiles through an antenna or a passive distribution system. In Uplink RF signal is converted into an optical signal in the Fiber Optic Transmitter of each Remote Unit and then it is propagated via fibre optics to the Master Unit. Optical signals from Remote Units are then converted by the Fiber Optic Receiver modules of the Master Unit into RF signals and transmitted to the signal recipient. Uplink and downlink optical signals are transmitted over the same single mode optical fibre (Wavelength Division Multiplexing -WDM- technology). One or more BTSs, Node Bs or Repeaters RF SIGNAL Fiber Optic Receivers Transmitters REMOTE UNITS RF Interface POI Subrack MASTER UNIT Optical Subrack RF SIGNAL Fiber Optic Receivers Transmitters OPTICAL SIGNALS RF SIGNAL Optical Systems management Teko Telecom Optical Systems can be set and managed locally via the LAN port of the Supervision Module of the Master Unit. For remote control the system can be accessed via Ethernet, via external PSTN or wireless modem or via optional built-in wireless modem. Teko Telecom Operation and Maintenance Terminal (OMT) software allows the commissioning, monitoring, setting and troubleshooting of the whole Teko Telecom Optical System. The access to the System is performed via web pages: the Supervision Module is equipped with a web-server and each component of the System is associated to a web page displaying detailed information about the component. The Supervision Module is also equipped with an SNMP-agent, which allows to control each parameter of the system via SNMP get/set/trap operations. www.tekotelecom.it www.tekotelecom.it Going further, together Teko Telecom Optical Systems Doc ID Number 91 080 0780 - Rel. 03 page 10 english Teko Telecom Operation Management Centre (OMC) proprietary software allows the management of multiple Teko Telecom Optical Systems in a Network. OMC is a client-server application: the server collects and stores information, such as System status and alarms, relevant to each Optical System in the network. The Server communicates with each System Supervision Module via Ethernet (TCP-IP socket) or via PSTN or wireless modem. The Client provides access to the information stored in the Server database. It allows end-users to check the status of the Optical Systems in the network via a user friendly graphical interface. www.tekotelecom.it www.tekotelecom.it Going further, together Teko Telecom Optical Systems Doc ID Number 91 080 0780 - Rel. 03 page 11 english Technical Specifications1.2 This paragraph makes Master Unit and Remote Units mechanical, environmental and power supply specifications available. Please refer to each product datasheet for detailed electrical specifications. Contact Teko Telecom Sales Office for further information. Master Unit• Dimensions19”-3U racks / depth 270 mm (10.63 in) Power supply85÷264Vac (50-60Hz) (TPSU/AC) -72÷-36Vdc (TPSU/48) Operating temperature range-5°C up to +45°C (+23°F up to +113°F) Remote Units• LOW POWER Dimensions (HxWxD)Weight Operating temperature range Degree of protection (IP) Power supply 350x350x100mm (13.78x13.78x3.94 in) max volume - heat sinks and connectors included 13 kg (28.7 lbs) -20°C up to +55°C (-4°F up to +131°F) IP32 (box) IP66 (wit…

Text truncated - open the document above for the full version.

Operational Description

www.tekotelecom.it www.tekotelecom.it Going further, together Teko Telecom Optical Systems Doc ID Number 91 080 0780 - Rel. 03 page 11 english Technical Specifications1.2 This paragraph makes Master Unit and Remote Units mechanical, environmental and power supply specifications available. Please refer to each product datasheet for detailed electrical specifications. Contact Teko Telecom Sales Office for further information. Master Unit• Dimensions19”-3U racks / depth 270 mm (10.63 in) Power supply85÷264Vac (50-60Hz) (TPSU/AC) -72÷-36Vdc (TPSU/48) Operating temperature range-5°C up to +45°C (+23°F up to +113°F) Remote Units• LOW POWER Dimensions (HxWxD)Weight Operating temperature range Degree of protection (IP) Power supply 350x350x100mm (13.78x13.78x3.94 in) max volume - heat sinks and connectors included 13 kg (28.7 lbs) -20°C up to +55°C (-4°F up to +131°F) IP32 (box) IP66 (with optional protection kit) 85÷264Vac (50-60Hz) /AC version -72 ÷ -36Vdc /48 version SMR700 LowSMR700 HighSMR900 (*) UL Operating Freq. band698 – 716 MHz776 – 787 MHz896 – 902 MHz DL Operating Freq. band728 – 746 MHz746 – 757 MHz935 – 941 MHz DL RF gain, in Master Unit tx 34 dB34 dB34 dB UL RF gain, out Mater Unit tx 47 dB47 dB47 dB DL output power29dBm (1 carrier) Mod.: LTE 29dBm (1 carrier) Mod.: LTE 29dBm (1 carrier) Mod.: iDEN (QAM) (*) including SMR900 band (UL: 896 - 901 MHz / DL: 935 - 940 MHz) and Narrow Band PCS (UL: 901 - 902 MHz / DL: 940 - 941 MHz).

Parts List/Tune Up Info

TEKO TELECOM Ufficio Tecnico Customer: Mnemonic: Product Code: Rev. PCB Code: Verified: Date: Item Qty Reference FEP Code TEKO T. Code Value Toll. Pwr Volt. Case Moun Description Om 1 1 15 005 4005 C.S. REMOTE UNIT LOW POWER MULTI+700 224 C1 C111 C152 C263 C283 C417 C418 C419 C420 C506 C583 C585 C589 C590 C591 C593 C733 C740 C750 C760 C770 C814 R401 R490 05 041 0285 1uF 10% 25V 0603 SMD CERAMICA X5R ; MULTILAYERS CAPACITOR 15/12/2009 Date: 18/12/2009 TEKO TELECOM data TEKO-TELECOM PROTOTIPO REMOTE UNIT LOW POWER MULTI+700 (*) Gianni Manganelli Approved: Marcello Zirone S7AMAW 01 15 005 4005 03/05/2010 15.19 Distinta Base S7AMAW.xls Pag. 1 di 34 TEKO TELECOM Ufficio Tecnico Item Qty Reference FEP Code TEKO T. Code Value Toll. Pwr Volt. Case Moun Description Om 385 C2 C10 C20 C33 C34 C44 C54 C55 C77 C78 C84 C85 C87 C91 C103 C104 C108 C116 C117 C120 C134 C136 C145 C149 C162 C167 C171 C176 C180 C187 C191 C201 C204 C211 C215 C220 C227 C285 C287 C294 C301 C317 C324 C330 C348 C355 C375 C380 C387 C389 C391 C398 C399 C406 C407 C414 C415 C431 C446 C456 C487 C497 C504 C531 C532 C533 C534 C535 C536 C537 C544 C550 C556 C557 C564 C565 C567 C575 C749 C759 C762 C764 C768 C778 C780 05 041 0185 1nF 10% 50V 0603 SMD CERAMICA X7R ; MULTILAYERS CAPACITOR 03/05/2010 15.19 Distinta Base S7AMAW.xls Pag. 2 di 34 TEKO TELECOM Ufficio Tecnico Item Qty Reference FEP Code TEKO T. Code Value Toll. Pwr Volt. Case Moun Description Om 451 L134 C3 C6 C38 C47 C121 C122 C137 C158 C172 C192 C195 C209 C212 C242 C254 C270 C345 C349 C429 C450 C452 C458 C465 C466 C467 C468 C469 C470 C471 C472 C473 C474 C475 C476 C477 C478 C479 C480 C481 C482 C483 C515 C523 C542 C566 C569 C614 C631 C732 C775 05 051 0195 22pF 0.1pF 250V 0603 SMD ATC ; ULTRA-LOW ESR, HIGH Q, CAPACITORS ; CODE : 600S22RBT250T 03/05/2010 15.19 Distinta Base S7AMAW.xls Pag. 3 di 34 TEKO TELECOM Ufficio Tecnico Item Qty Reference FEP Code TEKO T. Code Value Toll. Pwr Volt. Case Moun Description Om 582 C4 C7 C14 C18 C57 C58 C72 C79 C86 C89 C90 C92 C93 C94 C98 C100 C106 C112 C113 C115 C124 C126 C205 C206 C207 C244 C245 C257 C260 C266 C269 C275 C289 C292 C296 C318 C319 C320 C356 C357 C358 C393 C394 C401 C402 C409 C410 C445 C448 C459 C461 C489 C490 C502 C545 C553 C561 C594 C596 C598 C599 C707 C717 C718 C719 C720 C721 C722 C723 C724 C725 C726 C727 C728 C729 C730 C731 C739 C765 C781 C810 C811 05 041 0275 100nF 10% 50V 0603 SMD CERAMICA X7R ; MULTILAYERS CAPACITOR 03/05/2010 15.19 Distinta Base S7AMAW.xls Pag. 4 di 34 TEKO TELECOM Ufficio Tecnico Item Qty Reference FEP Code TEKO T. Code Value Toll. Pwr Volt. Case Moun Description Om 665 C5 C12 C16 C17 C19 C36 C65 C107 C132 C142 C179 C181 C182 C189 C199 C200 C223 C225 C226 C233 C234 C235 C236 C238 C240 C246 C256 C265 C278 C286 C299 C334 C340 C350 C362 C368 C383 C384 C494 C498 C499 C517 C521 C525 C529 C530 C577 C581 C601 C606 C615 C616 C617 C618 C619 C620 C627 C628 C633 C638 C639 C640 C800 C809 C4360 TBD TBD(NON MONTARE) 0603 SMD MULTILAYERS CAPACITOR 03/05/2010 15.19 Distinta Base S7AMAW.xls Pag. 5 di 34 TEKO TELECOM Ufficio Tecnico Item Qty Reference FEP Code TEKO T. Code Value Toll. Pwr Volt. Case Moun Description Om 735 C8 C15 C21 C75 C76 C82 C101 C102 C114 C150 C161 C166 C169 C178 C222 C224 C232 C243 C252 C253 C255 C276 C277 C404 C405 C412 C413 C516 C524 C546 C547 C548 C551 C552 C813 05 051 0235 47pF 5% 250V 0603 SMD ATC ; ULTRA-LOW ESR, HIGH Q, CAPACITORS ; CODE : 600S470JT250T 87 C9 C23 C49 C50 C51 C52 C571 05 040 0385 4.7uF 10% 50V 1206 SMD CERAMICA X5R ; MULTILAYERS CAPACITOR 9 1 C11 05 051 0109 0.9pF 0.1pF 250V 0603 SMD ATC ; ULTRA-LOW ESR, HIGH Q, CAPACITORS ; CODE : 600S0R9BT250T 03/05/2010 15.19 Distinta Base S7AMAW.xls Pag. 6 di 34 TEKO TELECOM Ufficio Tecnico Item Qty Reference FEP Code TEKO T. Code Value Toll. Pwr Volt. Case Moun Description Om 10 66 C13 C24 C27 C32 C39 C43 C53 C74 C95 C119 C123 C133 C135 C143 C144 C170 C175 C183 C186 C190 C193 C194 C198 C203 C210 C214 C219 C228 C261 C280 C314 C315 C316 C323 C326 C329 C343 C346 C347 C351 C352 C353 C354 C371 C374 C379 C382 C395 C396 C397 C403 C411 C449 C451 C455 C486 C503 C518 C526 C538 C541 C543 C549 C554 C555 C779 05 051 0255 100pF 5% 250V 0603 SMD ATC ; ULTRA-LOW ESR, HIGH Q, CAPACITORS ; CODE : 600S101JT250T 11 15 C22 C29 C159 C164 C184 C208 C217 C321 C327 C333 C339 C361 C367 C372 C377 05 051 0155 5.6pF 0.1pF 250V 0603 SMD ATC ; ULTRA-LOW ESR, HIGH Q, CAPACITORS ; CODE : 600S5R6BT250T 03/05/2010 15.19 Distinta Base S7AMAW.xls Pag. 7 di 34 TEKO TELECOM Ufficio Tecnico Item Qty Reference FEP Code TEKO T. Code Value Toll. Pwr Volt. Case Moun Description Om 12 72 C25 C48 C61 C63 C73 C97 C127 C128 C131 C230 C262 C281 C306 C307 C312 C313 C335 C336 C341 C342 C363 C364 C369 C370 C386 C421 C424 C426 C428 C430 C432 C433 C434 C491 C492 C493 C507 C511 C519 C527 C572 C574 C578 C580 C582 C584 C586 C587 C588 C592 C734 C735 C736 C737 C738 C742 C743 C744 C745 C746 C747 C748 C751 C752 C753 C754 C755 C756 C757 C758 C771 C812 05 041 0220 10nF 10% 50V 0603 SMD CERAMICA X7R ; MULTILAYERS CAPACITOR 13 10 C26 C81 C268 C293 C295 C435 C447 C595 C597 C815 05 040 0380 10uF 10% 16V 0805 SMD TAIYO YUDEN ;CERAMIC CHIP CAPACITOR ; X5R ; CODE :EMK212BJ106KG-T ; FARNELL CODE : 1463364 03/05/2010 15.19 Distinta Base S7AMAW.xls Pag. 8 di 34 TEKO TELECOM Ufficio Tecnico Item Qty Reference FEP Code TEKO T. Code Value Toll. Pwr Volt. Case Moun Description Om 14 1 C28 05 075 0515 330uF 20% 50V 1CE_V_9.1_12.5 SMD NIC ; COND. ELETTROLITICO CODE : NACE331M50V12.5x14 15 7 C30 C284 R432 C436 C513 C622 C632 05 051 0105 0.5pF 0.1pF 250V 0603 SMD ATC ; ULTRA-LOW ESR, HIGH Q, CAPACITORS ; CODE : 600S0R5BT250T 16 4 C31 C41 C213 C218 05 051 0140 3.9pF 0.1pF 250V 0603 SMD ATC ; ULTRA-LOW ESR, HIGH Q, CAPACITORS ; CODE : 600S3R9BT250T 17 3 C35 C42 C110 05 051 0115 1.5pF 0.1pF 250V 0603 SMD ATC ; ULTRA-LOW ESR, HIGH Q, CAPACITORS ; CODE : 600S1R5BT250 T 18 7 C37 C46 C237 C443 C462 C464 C500 05 051 0108 0.8pF 0.1pF 250V 0603 SMD ATC ; ULTRA-LOW ESR, HIGH Q, CAPACITORS ; CODE : 600S0R8BT250T 19 3 C40 C239 C308 05…

Text truncated - open the document above for the full version.

RF Exposure Info

Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 where:S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Maximum peak output power at antenna input terminal:29.00(dBm) Maximum peak output power at antenna input terminal:794.3282347(mW) Antenna gain(maximum):16(dBi) Maximum antenna gain:39.81071706(numeric) Time Averaging:100(%) Prediction distance:75(cm) Prediction frequency:720(MHz) MPE limit for uncontrolled exposure at prediction frequency:0.480(mW/cm^2) Power density at prediction frequency:0.447371(mW/cm^2) Margin of compliance:-0.3(dB) This equates to:4.473707743W/m^2 2 4R PG S π =

RF Exposure Info

Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 where:S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Maximum peak output power at antenna input terminal:29.00(dBm) Maximum peak output power at antenna input terminal:794.3282347(mW) Antenna gain(maximum):12.5(dBi) Maximum antenna gain:17.7827941(numeric) Time Averaging:100(%) Prediction distance:50(cm) Prediction frequency:720(MHz) MPE limit for uncontrolled exposure at prediction frequency:0.480(mW/cm^2) Power density at prediction frequency:0.449625(mW/cm^2) Margin of compliance:-0.3(dB) This equates to:4.496246651W/m^2 2 4R PG S π =

RF Exposure Info

Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 where:S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Maximum peak output power at antenna input terminal:33.80(dBm) Maximum peak output power at antenna input terminal:2398.832919(mW) Antenna gain(maximum):16(dBi) Maximum antenna gain:39.81071706(numeric) Time Averaging:100(%) Prediction distance:130(cm) Prediction frequency:720(MHz) MPE limit for uncontrolled exposure at prediction frequency:0.480(mW/cm^2) Power density at prediction frequency:0.449680(mW/cm^2) Margin of compliance:-0.3(dB) This equates to:4.496798541W/m^2 2 4R PG S π =

RF Exposure Info

Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 where:S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Maximum peak output power at antenna input terminal:33.80(dBm) Maximum peak output power at antenna input terminal:2398.832919(mW) Antenna gain(maximum):8(dBi) Maximum antenna gain:6.309573445(numeric) Time Averaging:100(%) Prediction distance:50(cm) Prediction frequency:720(MHz) MPE limit for uncontrolled exposure at prediction frequency:0.480(mW/cm^2) Power density at prediction frequency:0.481782(mW/cm^2) Margin of compliance:0.0(dB) This equates to:4.817815087W/m^2 2 4R PG S π =

RF Exposure Info

Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 where:S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Maximum peak output power at antenna input terminal:29.00(dBm) Maximum peak output power at antenna input terminal:794.3282347(mW) Antenna gain(maximum):16(dBi) Maximum antenna gain:39.81071706(numeric) Time Averaging:100(%) Prediction distance:65(cm) Prediction frequency:935(MHz) MPE limit for uncontrolled exposure at prediction frequency:0.623(mW/cm^2) Power density at prediction frequency:0.595612(mW/cm^2) Margin of compliance:-0.2(dB) This equates to:5.956119776W/m^2 2 4R PG S π =

RF Exposure Info

Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 where:S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Maximum peak output power at antenna input terminal:29.00(dBm) Maximum peak output power at antenna input terminal:794.3282347(mW) Antenna gain(maximum):13.5(dBi) Maximum antenna gain:22.38721139(numeric) Time Averaging:100(%) Prediction distance:50(cm) Prediction frequency:935(MHz) MPE limit for uncontrolled exposure at prediction frequency:0.623(mW/cm^2) Power density at prediction frequency:0.566044(mW/cm^2) Margin of compliance:-0.4(dB) This equates to:5.660439166W/m^2 2 4R PG S π =

RF Exposure Info

Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 where:S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Maximum peak output power at antenna input terminal:33.80(dBm) Maximum peak output power at antenna input terminal:2398.832919(mW) Antenna gain(maximum):16(dBi) Maximum antenna gain:39.81071706(numeric) Time Averaging:100(%) Prediction distance:110(cm) Prediction frequency:935(MHz) MPE limit for uncontrolled exposure at prediction frequency:0.623(mW/cm^2) Power density at prediction frequency:0.628065(mW/cm^2) Margin of compliance:0.0(dB) This equates to:6.280652507W/m^2 2 4R PG S π =

RF Exposure Info

Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 where:S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Maximum peak output power at antenna input terminal:33.80(dBm) Maximum peak output power at antenna input terminal:2398.832919(mW) Antenna gain(maximum):9(dBi) Maximum antenna gain:7.943282347(numeric) Time Averaging:100(%) Prediction distance:50(cm) Prediction frequency:935(MHz) MPE limit for uncontrolled exposure at prediction frequency:0.623(mW/cm^2) Power density at prediction frequency:0.606527(mW/cm^2) Margin of compliance:-0.1(dB) This equates to:6.065269843W/m^2 2 4R PG S π =

Test Report

15.231.doc - Date: April 13, 2010 www.nemko.com Report Reference ID: 148253-1TRFWL Test specification: Title 47 – Telecommunication Chapter I – Federal Communications Commission Subchapter B – Common carrier services − Part 27 – Miscellaneous wireless communications services Applicant: TEKO Telecom S.p.A. Via Meucci, 24/a I-40024 Castel S. Pietro Terme (BO) (Italy) Apparatus: Optical system FCC ID: XM2LOWPOWERL Model: TRU7S8AAWWL/AC-WS Testing laboratory: Nemko Italy S.p.A. Via Carroccio, 4 I-20046 Biassono (Italy) Name and title Date Tested by: G. Curioni, Wireless/EMC Specialist May 31, 2010 Reviewed by: P. Barbieri, Wireless/EMC Specialist May 31, 2010 . Product: TRU7S8AAWWL/AC-WS Report reference ID: 148253-1TRFWL Page 2 of 81 Table of contents Section 1: Report summary ......................................................................................................................................................... 3 1.1 Test specification.................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Alessandro Brunelli(Certification Engineer)
[email protected]+39 051 6946811Fax: +39 051 948473

Technical Contact

TEKO TELECOMMASSIMO NOTARGIACOMO
[email protected]39 051 6946811

VIA MEUCCI 24/A · CASTEL SAN PIETRO TERME · Italy

Non-Technical Contact

TEKO TELECOMMARCO DELLA MORA
[email protected]39 051 6946811

Test Firm

Nemko SpARalph Spanevello
[email protected]39-0392201201Fax: 39-0392201221

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
69935 MHz - 940 MHz800.00 mWD7WAmp
Confidentiality
Long Term
Grant Notes
Signal Booster. Power output listed is conducted. Users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3).

Other Applications from Teko Telecom Srl

XM2-RD35B35TW2

Dual Band Next Generation Very Very High Power Remote Unit 3450-3550 and 3700-3980

Mar 27, 2024

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
Remote Unit -Medium Power- 3450-3550 MHz - FCC ID XM2-MP35B35B - Teko Telecom Srl
XM2-MP35B35B

Remote Unit -Medium Power- 3450-3550 MHz

Apr 02, 2023

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
Next Generation Very Very High Power Remote Unit - FCC ID XM2-RD35TW2 - Teko Telecom Srl
XM2-RD35TW2

Next Generation Very Very High Power Remote Unit

Mar 27, 2023

Equipment Class

B2I - Part 20 Industrial Booster (CMRS)
Cellhub High Power Radio Remote Unit - FCC ID XM2-X25H2 - Teko Telecom Srl
XM2-X25H2

Cellhub High Power Radio Remote Unit

Aug 03, 2022

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Cell Hub High-power Radio Remote Unit - FCC ID XM2-X35H2B - Teko Telecom Srl
XM2-X35H2B

Cell Hub High-power Radio Remote Unit

Nov 02, 2020

Equipment Class

CBD - Citizens Band Category A and B Devices