FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Quectel Wireless Solutions Company Limited/
  3. XMR-16182010001

XMR-16182010001GPS Tracking Phone

Quectel Wireless Solutions Company Limited
GPS Tracking Phone - FCC ID XMR-16182010001 - Quectel Wireless Solutions Company Limited
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Feb 11, 2010
Application Purpose
Original Equipment
Date of Application
Feb 11, 2010
Equipment Note
GPS Tracking Phone
Frequency Range
1850.20000000 - 1909.80000000
Company
Quectel Wireless Solutions Company Limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

GS200 GPS Tracking Phone User Guide Contents 1 THE BASICS..............................................................7 1.1 INTRODUCTION.....................................................7 1.2 S AFETY NOTICE....................................................8 1.3 F OR YOUR SAFETY...............................................9 1.3.1 General matters............................................9 1.3.2 Phone Safety...............................................11 1.3.3 Battery Safety.............................................13 1.3.4 Charger Safety...........................................16 1.3.5 Cleaning and Maintenance........................18 2 BEFORE USE..........................................................19 2.1 T HE NAMES AND EXPLANATION OF EACH PART.19 2.1.1 Technical information................................19 2.1.2 Appearance................................................20 2.1.3 Keypad Instructions...................................21 2.1.4 Icon............................................................23 2.2 B ATTERY.............................................................23 2.2.1 Removal and Installation of the Battery.....24 2.2.2 Battery charging.........................................26 2.3 E ARPHONE..........................................................27 2.4 C ONNECTING TO THE NETWORK.........................28 2.4.1 SIM card.....................................................28 2.4.2 Insertion of the SIM Card...........................29 2.4.3 Turning the Phone On and Off...................31 2.4.4 Unlocking the Phone Lock.........................32 2.4.5 Unlocking the SIM card.............................33 2.4.6 Connecting to the Network.........................34 3 FLEETLY USER MANUAL...................................35 3.1 C HARACTERISTIC FUNCTION..............................35 3.2 D IALLING............................................................36 3.2.1 Making Domestic Calls..............................37 3.2.2 Calling Fixed Line Extensions...................37 3.2.3 Making International calls.........................38 3.3 E MERGENCY CALLS............................................39 3.4 R ECEIVING CALLS..............................................40 3.5 E NDING A CALL..................................................40 3.6 C ALL OPTION......................................................40 4 FUNCTION MENU.................................................42 4.1 HOW TO USE THE FUNCTION MENU...................42 4.1.1 Scroll to select Function.............................42 4.1.2 Speedily to select function..........................42 4.1.3 Exit a Menu................................................43 4.2 S TRUCTURE OF THE FUNCTION MENU................43 4.3 C ALL HISTORY....................................................49 4.3.1 Missed Calls...............................................49 4.3.2 Dialed Calls...............................................50 4.3.3 Received Calls............................................50 4.3.4 Delete Call Log..........................................51 4.3.5 Call Time....................................................51 4.3.6 Call Cost....................................................51 4.3.7 SMS Counter..............................................52 4.3.8 Auto Quick End..........................................52 4.4 C ALENDER..........................................................52 4.4.1 View Tasks..................................................53 4.4.2 Jump To Date.............................................54 4.4.3 Go To Weekly View.....................................54 4.5 S ERVICES............................................................54 4.6 P HONE BOOK......................................................54 4.7 M ESSAGES..........................................................60 4.7.1 SMS............................................................60 4.7.2 Chat............................................................69 4.7.3 Voice Mail Server.......................................70 4.7.4 Broadcast Message....................................70 4.8 U SER PROFILES...................................................71 4.9 S ETTINGS............................................................74 4.9.1 Phone Setup................................................74 4.9.2 Display Characteristic...............................76 4.9.3 Call Setup...................................................78 4.9.4 Network Setup............................................82 4.9.5 Security Setup.............................................84 4.9.6 Restore Factory Settings............................88 4.10 B LUETOOTH........................................................88 4.11 O RGANIZER........................................................90 4.11.1 Alarm..........................................................90 4.11.2 To Do List...................................................91 4.11.3 Calculator..................................................91 4.11.4 World Clock................................................92 4.11.5 Stopwatch...................................................92 4.11.6 Unit Converter...........................................92 4.11.7 Currency Converter....................................93 4.11.8 Health.........................................................93 5 INPUT METHODS..................................................94 5.1 G ENERAL OUTLINE.............................................94 5.2 S CREEN KEY VALUES..........................................94 6 TROUBLE SHOOTING.........................................96 1 The Basics 1.1 Introduction Thank you for choosing the GS200 GPS Tracking Phone. After reading this guide you will be able to fully master the use of your GS200 mobile phone and appreciate all its functions and ease of use. The GS200 GPS Tracking Phone is designed for use on the GSM networks. Not only does the GS200 provide you with basic calling fu…

Text truncated - open the document above for the full version.

ID Label/Location Info

FCC ID : XMR-16182010001

Internal Photos

Inside of EUT

RF Exposure Info

Ref: CR-280-3-08-SATB-B COMOSAR Dipole 835 MHz Calibration Report Page: 1/6 Issue: B Date: 2009/10/05 1 DIPOLE 835 MHZ CALIBRATION REPORT Prepared By: LUC Jérôme, SATIMO Project Description: SAR TEST BENCH Prepared For (End User): Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. Ref: CR-280-3-08-SATB-B COMOSAR Dipole 835 MHz Calibration Report Page: 2/6 Issue: B Date: 2009/10/05 2 DIPOLE 835 MHz CALIBRATION REPORT DATE: 19/02/2009 REFERENCE: SN 36/08 DIPC99 OBJECT: COMOSAR IEEE REFERENCE DIPOLE MANUFACTURER: SATIMO SERIAL NUMBER: SN 36/08 DIPC99 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 2 3/09/2009 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this document may be photocopied, reproduced without the prior written agreement of SATIMO. SATIMO shall not be liable for errors contained herein or for incidental or consequential in connection with the furnishing, performance or use of this material. Warranty doesn’t apply to Normal wear, Normal tear, Improper use, Improper maintain, Improper installation. Date SAR TEAM MANAGER Ref: CR-280-3-08-SATB-B COMOSAR Dipole 835 MHz Calibration Report Page: 3/6 Issue: B Date: 2009/10/05 3 PRODUCT DESCRIPTION Dimension: L=161 mm/ h=89.8mm / d=3.6 mm CALIBRATION TEST EQUIPMENT TYPE IDENTIFICATION DATE OF CALIBRATION Vector Network Analyzer HP8753D (SN: 5410A08882) 10-05-2009 MEASUREMENT PROCEDURE We placed the dipole under the flat part of SAM phantom fill with 835 MHz head liquid. Ref: CR-280-3-08-SATB-B COMOSAR Dipole 835 MHz Calibration Report Page: 4/6 Issue: B Date: 2009/10/05 4 Calibration was performed according to IEEE Std P1528-2003 and OET bulletin 65 Supplement C (Ed. 01-01) VSWR at 835 MHz: -24.77 dB. -24,77 -40 -35 -30 -25 -20 -15 -10 -5 0 0,7350,8350,935 Frequency (GHz) S11 (dB) Ref: CR-280-3-08-SATB-B COMOSAR Dipole 835 MHz Calibration Report Page: 5/6 Issue: B Date: 2009/10/05 5 SAR MEASUREMENT EQUIPEMENT Voltmeter Keithley (2000, SN:1000572) Date of calibration: 01-07-2009 Signal generator Rohde&Schwarz (SML_03, SN:101868) Date of calibration: 15-11-2008 Power amplifier Nuclétudes (ALB216, SN:10800) Date of calibration: 24-10-2008 Power meter Rohde&Schwarz (NRVD, SN:101066) Date of calibration: 04-07-200 9 Probe SATIMO Bretagne (SN:EP37) CF (30.41,29.18,32.33) Date of calibration: 19-06-2009 SAR MEASUREMENT CONDITION Software OpenSAR V3 Phantom SATIMO Bretagne (SN: SN_20_07_SAM42) Liquid SATIMO Bretagne (Last Calibration: 18 09 08) Head Liquid Values: eps’ : 41,20 sigma : 0,872 Distance between the center of the dipole and the liquid (set with a spacer) 15 mm Area scan resolution dx=8mm/dy=8mm Zoom scan resolution dx=8mm/dy=8m/dz=5mm Frequency 835 MHz Input power 30 dBm Expanded uncertainty (K=1) 8.09% SAR MEASUREMENT RESULT 10g 1g SAR measured Liquid : HL Input power : 1W 6,364 W/Kg + 2,64 % 9,805 W/Kg + 3,21 % Ref: CR-280-3-08-SATB-B COMOSAR Dipole 835 MHz Calibration Report Page: 6/6 Issue: B Date: 2009/10/05 6 SAR MEASUREMENT PLOTS

RF Exposure Info

Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 1/6 Issue: B Date: 2009/10/05 1 DIPOLE 1800 MHZ CALIBRATION REPORT Prepared By: LUC Jérôme, SATIMO Project Description: SAR TEST BENCH Prepared For (End User): Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 2/6 Issue: B Date: 2009/10/05 2 DIPOLE 1800 MHz CALIBRATION REPORT DATE: 19/02/2009 REFERENCE: SN 36/08 DIPF101 OBJECT: COMOSAR IEEE REFERENCE DIPOLE MANUFACTURER: SATIMO SERIAL NUMBER: SN 36/08 DIPF101 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 2 3/09/2009 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this document may be photocopied, reproduced without the prior written agreement of SATIMO. SATIMO shall not be liable for errors contained herein or for incidental or consequential in connection with the furnishing, performance or use of this material. Warranty doesn’t apply to Normal wear, Normal tear, Improper use, Improper maintain, Improper installation. Date SAR TEAM MANAGER Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 3/6 Issue: B Date: 2009/10/05 3 PRODUCT DESCRIPTION Dimension: L=72 mm/ h=41.7 mm / d=3.6 mm CALIBRATION TEST EQUIPMENT TYPE IDENTIFICATION DATE OF CALIBRATION Vector Network Analyzer HP8753D (SN: 5410A08882) 10-05-2009 MEASUREMENT PROCEDURE We placed the dipole under the flat part of SAM phantom fill with 1800 MHz head liquid. Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 4/6 Issue: B Date: 2009/10/05 4 Calibration was performed according to IEEE Std P1528-2003 and OET bulletin 65 Supplement C (Ed. 01-01) VSWR at 1800 MHz: -25.09 dB -25,09 -35 -30 -25 -20 -15 -10 -5 0 1,71,81,9 Frequency (GHz) S11 (dB) Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 5/6 Issue: B Date: 2009/10/05 5 SAR MEASUREMENT EQUIPEMENT Voltmeter Keithley (2000, SN:1000572) Date of calibration: 01-07-2009 Signal generator Rohde&Schwarz (SML_03, SN:101868) Date of calibration: 15-11-2008 Power amplifier Nuclétudes (ALB216, SN:10800) Date of calibration: 24-10-2008 Power meter Rohde&Schwarz (NRVD, SN:101066) Date of calibration: 04-07-2009 Probe SATIMO Bretagne (SN:EP37) CF (35.35,34.93,37.42) Date of calibration: 19-06-2009 SAR MEASUREMENT CONDITION Software OpenSAR V3 Phantom SATIMO Bretagne (SN: SN_20_07_SAM42) Liquid SATIMO Bretagne (Last Calibration: 19 09 08) Head Liquid Values: eps’ : 39,80 sigma : 1,45 Distance between the center of the dipole and the liquid (set with a spacer) 10 mm Area scan resolution dx=8mm/dy=8mm Zoom scan resolution dx=8mm/dy=8m/dz=5mm Frequency 1800 MHz Input power 30 dBm Expanded uncertainty (K=1) 8.09% SAR MEASUREMENT RESULT 10g 1g SAR measured Liquid : HL Input power : 1W 20,05 W/Kg + 1,24 % 39,32 W/Kg + 3,20 % Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 6/6 Issue: B Date: 2009/10/05 6 SAR MEASUREMENT PLOTS

RF Exposure Info

Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 1/26 Issue: A Date: 2009/10/06 1 COMOSAR E-FIELD PROBE CALIBRATION REPORT Prepared By: LUC Jérôme, SATIMO Project Description: SAR TEST BENCH Prepared For (End User): Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 2/26 Issue: A Date: 2009/10/06 2 COMOSAR SEPT ISOTROPIC E-FIELD PROBE CALIBRATION REPORT DATE: 12/02/2009 REFERENCE: SN 37/08 EP80 OBJECT: COMOSAR SEPT ISOTROPIC E-FIELD PROBE MANUFACTURER: SATIMO SERIAL NUMBER: SN 37/08 EP80 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 24/09/200 9 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this document may be photocopied, reproduced without the prior written agreement of SATIMO. SATIMO shall not be liable for errors contained herein or for incidental or consequential in connection with the furnishing, performance or use of this material. Warranty doesn’t apply to Normal wear, Normal tear, Improper use, Improper maintain, Improper installation. Date SAR TEAM MANAGER Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 3/26 Issue: A Date: 2009/10/06 3 PRODUCT DESCRIPTION Frequency Range 100 MHz - 30 GHz Probe length 330 mm Length of one dipole 4.5 mm Maximum external diameter 8 mm Probe extremity diameter 6.5 mm Distance between dipoles/probe extremity < 2.7 mm Resistance of the three dipole (at the connector) Dipole 1: R1=1.4382 MΩ Dipole 2: R2=1.4894 MΩ Dipole 3: R3=1.4683 MΩ Connector (HIROSE series SR30) 6 wire male (Hirose SR30series) The probe could be checked by measuring the resistance of the three dipoles. CALIBRATION TEST EQUIPMENT TYPE IDENTIFICATION Calibration bench CALISAR Multimeter Keithley 2000 Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 4/26 Issue: A Date: 2009/10/06 4 MEASUREMENT PROCEDURE Probe calibration is realized, in compliance with CENELEC EN 50361 and IEEE 1528 std, with CALISAR, Antennessa proprietary calibration system. The calibration is performed with the EN 50361 annexe technique using reference guide at the five frequencies. Where : P fw = Forward Power P bw = Backward Power a and b = Waveguide dimensions  = Skin depth Keithley configuration: Rate = Medium; Filter =ON; RDGS=10; FILTER TYPE =MOVING AVERAGE; RANGE AUTO After each calibration, a SAR measurement is performed on a validation dipole and compared with a NPL calibrated probe, to verify it. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 5/26 Issue: A Date: 2009/10/06 5 PROBE UNCERTAINTIES Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 6/26 Issue: A Date: 2009/10/06 6 1. Calibration at 450.00 MHz A. Calibration parameters. Label GSM450 Epsilon 43.33 Sigma 0.84 S/m Temperature 21°C Antenna gain 2.03 dB Antenna S11 -10.50 dB Low limit detection (CW) 0.72 V/m (0.47 mW/kg) Calibration curves ei=f(V) (i=1,2,3) allow to obtain E-field value using the formula: 2 3 2 2 2 1 **EEEE= The following tables represent the calibration curves linearization by curve segment in CW signal. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 7/26 Issue: A Date: 2009/10/06 7 Calibration coefficients for the three dipoles in CW: v1 e1 v2 e2 v3 e3 0.584004 419.557857 -0.696059 435.622023 0.541191 412.830715 0.467833 339.207465 -0.556278 351.381991 0.469757 336.297240 0.376994 276.348283 -0.452232 288.647980 0.378826 274.224190 0.302778 224.954643 -0.359005 232.397390 0.305842 224.365698 0.241038 182.154071 -0.286978 188.889931 0.246562 183.825274 0.192549 148.484090 -0.230386 154.650994 0.195712 148.993075 0.154033 121.674762 -0.185412 127.378480 0.157543 122.783107 0.123397 100.276479 -0.147311 104.193802 0.125866 100.956090 0.099878 83.770361 -0.118637 86.660489 0.101471 84.063863 0.081165 70.553219 -0.095250 72.263937 0.082289 70.694342 0.065166 59.152028 -0.076788 60.795323 0.066427 59.538957 0.051916 49.592416 -0.061280 51.041514 0.053353 50.232492 0.041968 42.297602 -0.048746 43.022565 0.042906 42.675214 0.033724 36.126757 -0.039149 36.748110 0.034686 36.605243 0.021855 26.962568 -0.024798 27.024723 0.022272 27.149463 0.018405 23.975145 -0.020856 24.085809 0.018755 24.141334 0.015467 21.515985 -0.017534 21.515985 0.015767 21.615299 0.013018 19.309065 -0.014750 19.398191 0.013276 19.487731 0.010938 17.408496 -0.012392 17.529166 0.011157 17.569575 0.009022 15.586953 -0.010228 15.658899 0.009215 15.676938 0.007353 13.956010 -0.008328 13.988181 0.007484 14.020428 0.005989 12.466979 -0.006801 12.495719 0.006111 12.567858 0.004890 11.214019 -0.005573 11.265779 0.005003 11.330818 0.004019 10.133541 -0.004570 10.121882 0.004099 10.168601 0.003279 9.094132 -0.003739 9.157170 0.003352 9.125596 0.002660 8.095827 -0.003041 8.293946 0.002769 8.265350 0.002126 7.324219 -0.002453 7.366500 0.002188 7.358024 0.001685 6.565400 -0.001947 6.580536 0.001724 6.542765 0.001300 5.784440 -0.001511 5.718225 0.001334 5.757862 0.001123 5.245191 -0.001307 5.269400 0.001174 5.275471 0.000891 4.701768 -0.001057 4.723470 0.000924 4.728912 0.000704 4.209798 -0.000850 4.226839 0.000736 4.243862 0.000574 3.790376 -0.000689 3.791428 0.000603 3.830551 0.000457 3.396200 -0.000570 3.434303 0.000483 3.421852 0.000365 3.050686 -0.000463 3.078014 0.000389 3.079630 0.000292 2.745766 -0.000369 2.726866 0.000311 2.759206 0.000236 2.486639 -0.000312 2.489933 0.000246 2.460514 0.000…

Text truncated - open the document above for the full version.

RF Exposure Info

Report No.: SZ10010097S01 Contents 1.1. Notes ......................................................................................................................................... 3 1.2. Organization item.................................................................................................................... 3 1.3. Conclusion ................................................................................................................................ 3 2. TESTING LABORATORY ....................................................................................................... 4 2.1. Identification of the Responsible Testing Laboratory.......................................................... 4 2.2. Identification of the Responsible Testing Location .............................................................. 4 2.3. Accreditation Certificate ........................................................................................................ 4 2.4. List of Test Equipments .......................................................................................................... 4 3. TECHNICAL INFORMATION ............................................................................................... 5 3.1. Identification of Applicant ...................................................................................................... 5 3.2. Identification of Manufacturer .............................................................................................. 5 3.3. Equipment Under Test (EUT) ................................................................................................ 5 3.3.1. Photographs of the EUT .................................................................................................. 6 3.3.2. Identification of all used EUTs ........................................................................................ 6 4. TEST RESULTS ......................................................................................................................... 6 4.1. Applied Reference Documents ............................................................................................... 6 4.2. Test Environment/Conditions ................................................................................................ 7 4.3. Operational Conditions During Test ..................................................................................... 8 4.3.1. Informations On The Testing .......................................................................................... 8 4.3.2. The Measurement System ............................................................................................. 10 4.3.3. Uncertainty Assessment ................................................................................................. 12 4.3.4. Equipments and results of validation testing ............................................................... 13 4.3.5. Dielectric Performance .................................................................................................. 14 4.3.6. Simulant liquids .............................................................................................................. 15 4.4. Items used in the Test Results List ....................................................................................... 15 4.5. Test Results List ..................................................................................................................... 16 ANNEX A ACCREDITATION CERTIFICATE ................................................ 18 ANNEX B PHOTOGRAPHS OF THE EUT ...................................................... 19 ANNEX C GRAPH TEST RESULTS ................................................................. 22 Page 2 of 149 Report No.: SZ10010097S01 2. Testing Laboratory 2.1. Identification of the Responsible Testing Laboratory Company Name: Shenzhen Electronic Product Quality Testing Center Department: Morlab Laboratory Address: 3/F, Electronic Testing Building, Shahe Road, Nanshan District, Shenzhen, 518055 P. R. China Responsible Test Lab Manager: Mr. Shu Luan Telephone: +86 755 86130268 Facsimile: +86 755 86130218 2.2. Identification of the Responsible Testing Location Name: Shenzhen Electronic Product Quality Testing Center Morlab Laboratory Address: 3/F, Electronic Testing Building, Shahe Road, Nanshan District, Shenzhen, 518055 P. R. China 2.3. Accreditation Certificate Accredited Testing Laboratory: No. CNAS L1659 (see 0) 2.4. List of Test Equipments No. Instrument Type 1 PC Dell (Pentium IV 2.4GHz, SN:X10-23533) 2 Network Emulator Rohde&Schwarz (CMU200, SN:105894) 3 Voltmeter Keithley (2000, SN:1000572) 4 Synthetizer Rohde&Schwarz (SML_03, SN:101868) 5 Amplifier Nucl udes (ALB216, SN:10800) 6 Power Meter Rohde&Schwarz (NRVD, SN:101066) 7 Probe Antennessa (SN:SN_3708_EP80) 8 Phantom Antennessa (SN:SN_36_08_SAM62) 9 Liquid Antennessa (Last Calibration:21 08 04) Page 4 of 149 Report No.: SZ10010097S01 3. Technical Information Note: the following data is based on the information by the applicant. 3.1. Identification of Applicant Company Name: Quectel Wireless Solutions Co.,Ltd Address: Room 801, Building E, No 1618 Yishan Road, Shanghai, China,201103 3.2. Identification of Manufacturer Company Name: Quectel Wireless Solutions Co.,Ltd Address: Room 801, Building E, No 1618 Yishan Road, Shanghai, China,201103 3.3. Equipment Under Test (EUT) Brand Name: QUECTEL Type Name: QUECTEL Marking Name: GS200 Modulation Mode: GMSK Hardware Version: V1.02 Antenna type: Build inside Software Version: B03 Development Stage: Identical prototype Frequency Bands: GSM 850MHz (channel 128:824.20MHz,channel 190:836.59MHz, channel 251:848.29MHz) PCS 1900MHz (channel 512:1850.19MHz,channel 661:1880.00MHz, channel 810:1909.80MHz) Battery Model: GS200 Battery specification: 1150mAh 3.7V Development Stage Antenna distance : Note: So just did the BT and GSM simultaneously SAR test with the request of the client. Identical prototype B…

Text truncated - open the document above for the full version.

Test Report

Report No.: SH10010035R01 TABLE OF CONTENT 1. TEST CERTIFICATION ........................................................................................................... 4 2. GENERAL INFORMATION .................................................................................................... 5 2.1 EUT Description ......................................................................................................................... 5 2.2 Test Standards and Results.......................................................................................................... 7 2.3 Facilities and Accreditations ....................................................................................................... 8 2.3.1 Facilities ...................................................................................................................................... 8 2.3.2 Test Environment Conditions ...................................................................................................... 8 3. 47 CFR PART 2, PART 22H &24E REQUIREMENTS ......................................................... 9 3.1 Frequencies .................................................................................................................................. 9 3.1.1 Requirement .............................................................................................................................. 9 3.1.2 Test Description ........................................................................................................................ 9 3.1.3 Test Result ............................................................................................................................... 10 3.2 Conducted RF Output Power .................................................................................................. 15 3.2.1 Requirement ............................................................................................................................ 15 3.2.2 Test Description ...................................................................................................................... 15 3.2.3 Test Result ............................................................................................................................... 15 3.3 20dB Occupied Bandwidth ...................................................................................................... 22 3.3.1 Definition ................................................................................................................................ 22 3.3.2 Test Description ...................................................................................................................... 22 3.3.3 Test Verdict .............................................................................................................................. 22 3.4 Frequency Stability ................................................................................................................... 29 3.4.1 Requirement ............................................................................................................................ 29 3.4.2 Test Description ...................................................................................................................... 29 3.4.3 Test Verdict .............................................................................................................................. 29 3.5 Conducted Out of Band Emissions ......................................................................................... 32 3.6 Requirement .............................................................................................................................. 32 3.6.1 Test Description ...................................................................................................................... 32 3.6.2 Test Result ............................................................................................................................... 32 3.6 Band Edge ............................................................................................................................. 39 3.6.1 Requirement ............................................................................................................................ 39 Page 2 of 56 Report No.: SH10010035R01 3.6.2 Test Description ...................................................................................................................... 39 3.6.3 Test Result ............................................................................................................................... 39 3.7 Transmitter Radiated Power (EIRP/ERP) ............................................................................ 44 3.7.1 Requirement ...........................................................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jean Hu
[email protected]+8602150086326Fax: +862153253668

Test Firm

Shenzhen Morlab Communications Technology Co.,LtdShu Luan
[email protected]0086-0755-86113898Fax: 0086-0755-86130218

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224E1.85 GHz - 1.91 GHz1.346 W300KGXW2.5 ppm
Confidentiality
Long Term
Grant Notes
Power listed is ERP for part 22 and EIRP for part 24. This device contains functions that are not operational in U.S Territories. This filing is only applicable for US operations. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum separation distance of 1.5 cm between the device and the body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are Head: 0.523 W/kg; Body-worn: 0.985 W/kg.

Other Applications from Quectel Wireless Solutions Company Limited

XMR2026FME163R

WIFI module

Aug 18, 2026

Equipment Class

DTS - Digital Transmission System
XMRAG591EROWL

Automotive Module

Aug 11, 2026

Equipment Class

PCB - PCS Licensed Transmitter
XMR2026FME172Q

Wi-Fi & Bluetooth Module

Aug 07, 2026

Equipment Class

DTS - Digital Transmission System
XMR2025HCM010SE

Bluetooth Module

Aug 05, 2026

Equipment Class

DTS - Digital Transmission System
XMR2026HCM213S

BLE Module

Aug 05, 2026

Equipment Class

DTS - Digital Transmission System