FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Withings/
  3. XNAWPM02

XNAWPM02Blood Pressure Monitor

Withings
Blood Pressure Monitor - FCC ID XNAWPM02 - Withings
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 18, 2013
Application Purpose
Original Equipment
Date of Application
Sep 14, 2013
Equipment Note
Blood Pressure Monitor
Frequency Range
2402.00000000 - 2480.00000000
Company
Withings
Country
France

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Withings Blood Pressure Monitor Version 2.0 AUG. 2013 Withings Blood Pressure Monitor User’s Guide 2 Withings is the trademark of this product and all other trademarks or Website mentioned in this document are the properties of their respective owners. Disclaimer Information in this guide may change without notice. The manufacturer assumes no responsibilities for errors that may appear in this guide. Reference to Standards This device complies with the following normative do cuments : COUNCIL DIRECTIVE 93/42/EEC of 14 June 1993 concerning medical devices as amended by Directive 2007/47/EC * EN ISO 13485:2003 /AC: 2009:Medical devices ‐ Quality management systems – Requirements for regulatory purposes (ISO 13485:2003) Reference to standards contd. * EN ISO14971:2012: Medical devices ‐ Application of risk management to medical devices (ISO 14971:2007, Cor rected version 2007‐10‐01) * IEC60601‐1: 2005 + CORR. 1 (2006) + CORR. 2 (2007); EN 60601‐1:2006+AC (2010) : Medical electrical equipment ‐ Part 1:General requirements for basic safety and essential Performance * EN1060‐3:1997+A1:2005+A2:2009: Non‐invasive sphygmomanometers,Part 3: Supplementary requirements for electromechanical blood pressure measuring systems * EN106 0‐4: 2004 Non‐invasive sphygmomanometers. Test procedures to determine the overall system accuracy of automated non‐invasive sphygmomanometers. *IEC/EN 60601‐1‐11 : General requirements for basic safety and essential performance –Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment *IEC 80 601‐2‐30: 2009 (First Edition) for use in conjunction with IEC 60601‐1:2005 EN 80601‐2‐30: 2010/ ANSI/AAMI 80601‐2‐30: 2009 : Particular requirements for the basic safety and essential performance of automated non‐invasive sphygmomanometers *EN300328 V1.8.1 Electromagnetic compatibility and Radio spectrum Matters (ERM); W ideband transmission systems; Data transmission equipment operating in the 2,4 GHz ISM band and using wide band modulation techniques; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive *EN301489‐1‐3 V1.9.2 (2011 ) Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for rad io equipment and services; Part 1: Common technical requirements *EN301489‐1‐17 V2.2.1(2012) Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements *EN60601‐1‐2: 2007 CISPR: 2011: Medical electrical equipment: Part 1‐2: General requirements for basi c safety and essential performance‐collateral standard electromagnetic compatibility *EN 55011:2009/A1:2010 : Industrial, scientific and medical equipment ‐ Radio‐frequency disturbance characteristics ‐ Limits and methods of measurement *FCC part B 15B: 2013 Electromagnetic Compatibility FCC Rule Part: 15.247 Cat: DSS (Bluetooth) FCC Rule Part: 15.247 Cat: DTS (BT4.0) *EN ISO 1 0993‐1:2009 Biological evaluation of medical devices‐Part 1: Evaluation and testing within a risk management process (ISO 10993‐1:2009) * ANSI/AAMI SP10: 2002/A1 2003(R) 2008: Manual, electronic or automated sphygmomanometers * ANSI/AAMI/ISO 81060‐2:2009 Non‐invasive sphygmomanometers Part 2: Clinical validation of automated measurement type Requirements 2013 US Importer : Withings Inc. 16192 Coastal Highway Lewes DE 19 Kahl Handelsvertretung Add.: Isarstr.33 40699 Erkrath, Germany Tel: +49 21 0447 754 Withings SAS 20 bis rue Rouget de Lisle 92130 Issy‐les‐Moulineaux Type BF Applied Part (cuff) WEEE IP22 Ingress of water or particulate matter FCC ID : XNAWPM02 EU REPRESENTATIVE Withings Blood Pressure Monitor User’s Guide 3 In order to use your Withings Blood Pressure Monitor, you need an iPhone, iPad, iPod touch (iOS 5 and higher) or Android (v2.3.3 and higher) Package content  Withings Blood Pressure Monitor  Four AAA alkaline (LR3) cells (already inserted)  Micro‐USB to USB adapter  User manual Important Safety Information Consult your doctor during pregnancy, arrhythmia and arteriosclerosis. Please read this section carefully before using the blood pressure monitor. Micro‐USB to USB adapter Withings Blood Pressure Monitor User’s Guide 4 Intended use The device is a digital monitor intended for use in measuring blood pressure and pulse rate in adult patient population with arm circumference ranging from 9 inches to 17 inches (22cm‐ 42cm). This device is not intended to be a diagnostic device. Contact your physician if hypertensive values are indicated. General safety and precautions  Do not forcibly bend the arm cuff  Do not inflate the arm cuff when it is not wrapped around your arm  Do not apply strong shocks and vibrations to the blood pressure monitor or drop it  Do not take measurement after bathing, drinking alcohol, smoking, exercising or eating.  Do not imme rse the arm cuff in water Caution General usage Always consult your doctor. Self‐diagnosis of measurement results and self treatment are dangerous People with severe blood flow problems, or blood disorders, should consult a doctor before using the blood pressure monitor. Cuff inflation can cause internal bleeding. Operational factors such as common arrhythmias, ventricular premature beats, atrial fibrillation, arterial sclerosis, poor perfusion, di abetes, age, pregnancy, pre‐eclampsia or renal disease can affect the performance of the automated sphygmomanometer and/or its blood pressure reading. This device is a precision measuring equipment liable to be understood by lay user but it still should be handled with care. A long exposure of the device to li nt, dust or sunlight might reduce its life time or damage it. Damaged cuff or sensor might lead to incorrect measurements. • Do not leave the blood pressure monitor unattended with infants or persons who cannot express their consent. • Do not use the blood pr…

Text truncated - open the document above for the full version.

Cover Letter(s)

Page 1 Ethertronics’ series of BT Ceramic Antennas deliver on the key needs of device designers for higher functionality and performance in smaller/thinner designs. These innovative antennas provide compelling advantages for Bluetooth enabled cell phones, media players and other mobile devices. PRODUCT SPEC SHEET: BLUETOOTH™ ANTENNA Embedded Bluetooth™ Ceramic Antenna 2.4 GHz, 2.0x1.2mm DESIGN ADVANTAGES Best in Class Performance • Minimal ground clearance and component “keep out” area. • High selectivity eliminates the need for addition- al filters and frees up board space. Quicker Time-to-Market • Standard part means fewer design changes. • Simple implementation. • Single part works for various PCB sizes and lay- outs. RoHS Compliant • Ethertronics’ antennas comply with the European RoHS Directive 2002/95/EC. ETHERTRONICS 9605 Scranton Road, Suite 300 | San Diego, CA 92121 - USA | www.ethertronics.com tel +(1) 858.550.3820 | fax +(1) 858.550.3821 | contact: [email protected] Part No. 1001312 SERVICE AND SUPPORT Extensive RF Experience • Our antennas are supported by extensive documenta- tion, and when needed, by the expertise of RF engi- neers who have integrated hundreds of antenna de- signs into wireless devices. Global Operations & Design Support • Ethertronics’ global operations encompass an inte- grated network of design centers that provide local customer support. END USER ADVANTAGES Superior Range • Greater antenna efficiency means longer range and a better end user experience. Exceptional Coverage • Better coverage delivers more reliable wireless con- nections for mobile phones, laptops, stereo headsets, cars media players, audio systems and more. KEY BENEFITS More information is available on our Website at www.ethertronics.com/resources/. Page 2 Ethertronics’ Embedded BT Ceramic Antenna Specifications Ethertronics produces a wide variety of standard and custom antennas to meet user needs. Below are the typical specs for a BT application. PRODUCT: BT Antenna Electrical Specifications Typical Characteristics All values are defined at Pi matching circuit will be required *Test board size = 110x55mm ground plane. BT Antenna Specifications Frequency Band 2.400GHz~2.483GHz VSWR Less than 3 Polarization Linear *Peak Gain 1.72 dBi Typ. 72.3% Typ Impedance 50Ω Typ. *Peak Efficiency Mechanical Specifications Size 2.00x1.20x0.55mm Mounting Surface Mount VSWR L W H A 2.0±0.3 1.2±0.3 .55±0.2 0.4±0.25 Page 3 PRODUCT: BT Antenna Recommended PCB Layout (Unit = mm) *Clearance area 8mm x 2.5mm: All metallization should be removed from all PCB layers. RF Input Matching Component *0402 Component Pad Pad *Clearance Area: 8x2.5mm *The 0402 Component is used for tuning the frequency in very limited, extreme cases. In most applications, the 0402 component will not be necessary. 8 3.5 1.5 2.25 2.25 0.5 0.5 0.4 1.25 1 1.4 1.1 1.8 0.7 0.44 0.68 0.72 2.5 Page 4 PRODUCT: BT Antenna 2D Gain Patterns (2442 MHz) E-theta E-phi E-total Page 5 PRODUCT: BT Antenna Tape & Reel Specifications Quantity/Reel = 5,000 Symbol Spec. A 178.0±2.0 B 2.0±0.5 C 13.0±0.5 D 21.0±0.8 E 62.0±1.5 F 9.0±0.5 G 13.0±1.0 Unit = mm A B C D E F L W 8.00±0.30 3.5±0.05 1.75±0.10 2.00±0.05 4.00±0.10 1.50±0.10 2.30±0.10 1.55±0.10 Page 6 PRODUCT: BT Antenna Reliability Testing Storage Conditions Item Condition Specification Thermal Shock 1. 30±3 minutes at -40°C±5°C 2. Convert to +105°C (5 minutes) 3. 30±3 minutes at +105°C±5°C 4. Convert to -40°C (5 minutes) 5. Total: 100 continuous cycles No apparent damage. Fulfills the electrical spec after test. Humidity Resistance 1. Humidity: 85% R.H. 2. Temperature: 85±5°C 3. Time: 1,000 hours No apparent damage. Fulfills the electrical spec after test. High Temperature Resistance 1. Temperature: 150°C±5°C 2. Time: 1,000 hours No apparent damage. Fulfills the electrical spec after test. Low Temperature Resistance 1. Temperature: -40°C±5°C 2. Time: 1,000 hours No apparent damage. Fulfills the electrical spec after test. Soldering Heat Resistance 1. Solder bath temperature: 260±5°C 2. Bathing time: 10±1 seconds No apparent damage. Solderability The dipped surface of the terminal shall be at least 95% covered with solder after being dipped in a solder bath of 245±5°C for 3±1 seconds No apparent damage. Warehouse Temperature Range: The temperature should be within 0~30°C and humidity should be less than 60% RH. The product should be used within 1 year from the time of delivery On Board Temperature Range: The temperature should be within -40~85°C and humidity should be less than 85% RH. Operating Temperature Range Operating temperature range: -40°C to +105°C Page 7 PRODUCT: BT Antenna Recommended Reflow Soldering © 2011 Ethertronics. All rights reserved. Ethertronics, the Ethertronics logo, shaping antenna technology, Isolated Magnetic Dipole and the iMD logo are trademarks of Ethertronics. All other trademarks are the property of their respective owners. Specifications subject to change and are dependent upon actual implementation. BT 8/10/11 A 1 st Rising Temperature The normal to preheating temperature 30s to 60s B Preheating 140°C to 160°C 60s to 120s C 2 nd Rising Temperature Preheating to 200°C 20s to 40s D Main Heating if 220°C 50s~60s if 230°C 40s~50s if 240°C 30s~40s if 250°C 20s~40s if 260°C 20s~40s E Regular Cooling 200°C to 100°C 1°C /s ~ 4°C /s *reference: J-STD-020C Soldering Gun Procedure Note the following when using a solder gun to replace the antenna 1. The tip temperature must be less than 350°C for the period within 3 seconds when using a soldering gun under 30W. 2. The soldering gun tip shall not touch this part directly. Soldering Volume Note that excess of soldering volume will easily crach the body of this product. Time Temperature of termination

External Photos

Report No.: EF/2013/70016 FCC ID: XNAWPM02 Issue Date: Aug. 14, 2013 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm . Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.tw.sgs.com Member of SGS Group APPENDIX 2 EXTERNAL PHOTOGRAPHS OF EUT Report No.: EF/2013/70016 FCC ID: XNAWPM02 Issue Date: Aug. 14, 2013 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm . Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.tw.sgs.com Member of SGS Group Front View of EUT Back View of EUT Report No.: EF/2013/70016 FCC ID: XNAWPM02 Issue Date: Aug. 14, 2013 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm . Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.tw.sgs.com Member of SGS Group Side View of EUT – 1 Side View of EUT – 2 Report No.: EF/2013/70016 FCC ID: XNAWPM02 Issue Date: Aug. 14, 2013 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm . Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. A…

Text truncated - open the document above for the full version.

ID Label/Location Info

Label & Label location FCC ID: XNAWPM02 FCC ID:XNAWPM S N 020000AB1234 2013.8.1追加防水防塵IP22標示 2013.8.13追加FCC ID:XNAWPM02

Internal Photos

Report No.: EF/2013/70016 FCC ID: XNAWPM02 Issue Date: Aug. 14, 2013 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm . Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.tw.sgs.com Member of SGS Group APPENDIX 3 INTERNAL PHOTOGRAPHS OF EUT Report No.: EF/2013/70016 FCC ID: XNAWPM02 Issue Date: Aug. 14, 2013 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm . Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.tw.sgs.com Member of SGS Group Open View of EUT-1 Open View of EUT-2 Report No.: EF/2013/70016 FCC ID: XNAWPM02 Issue Date: Aug. 14, 2013 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm . Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.tw.sgs.com Member of SGS Group Open View of EUT-3 Open View of EUT-4 Report No.: EF/2013/70016 FCC ID: XNAWPM02 Issue Date: Aug. 14, 2013 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm . Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. An…

Text truncated - open the document above for the full version.

Test Report

Report No.: EF/2013/80006 FCC ID: XNAWPM02 Issue Date: Aug. 14, 2013 Page: 1 of 46 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm . Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.tw.sgs.com Member of SGS Group ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT INTENTIONAL RADIATOR CERTIFICATION TO FCC PART 15 SUBPART C REQUIREMENT OF Product Name: Blood Pressure Monitor Brand Name: N/A Model No.: BP-801 Model Difference: N/A FCC ID: XNAWPM02 Report No.: EF/2013/80006 Issue Date: Aug. 14, 2013 FCC Rule Part: §15.247, Cat: DTS Prepared for: Withings 20 rue Rouget de Lisle, Issy-les-Moulineaux, France Prepared by: SGS Taiwan Ltd. Electronics & Communication Laboratory No.134, Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803 Note: This report shall not be reproduced except in full, without the written approval of SGS Taiwan Ltd. This doc- ument may be altered or revised by SGS Taiwan Ltd. per- sonnel only, and shall be noted in the revision section of the document. Report No.: EF/2013/80006 FCC ID: XNAWPM02 Issue Date: Aug. 14, 2013 Page: 2 of 46 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/新北市五股區新北產業園區五工路134號 台灣檢驗科技股份有限公司 t (886-2) 2299-3279 f (886-2) 2298-0488 www.tw.sgs.com Member of SGS Group VERIFICATION OF COMPLIANCE Applicant: Withings 20 rue Rouget de Lisle, Issy-les-Moulineaux, France Product Name: Blood Pressure Monitor Brand Name: N/A Model No.: BP-801 Model Difference: N/A FCC ID: XNAWPM02 File Number: EF/2013/80006 Date of test: Jul. 29, 2013 ~ Aug. 09, 2013 Date of EUT Received: Jul. 29, 2013 We hereby certify that: The above equipment was tested by SGS Taiwan Ltd. Electronics & Communication Laboratory The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4:2009 and the energy emitted by the sample EUT tested as described in this report is in compliance with conducted and radiated emission limits of FCC Rules Part 15.247. The test results of this report relate only to the tested sample identified in this report. Test By: Date Aug. 14, 2013 Nick Lin / Engineer Prepared By: Date Aug. 14, 2013 Judy Hsu / Clerk Approved By: Date Aug. 14, 2013 Jim Chang / Supervisor Report No.: EF/2013/80006 FCC ID: XNAWPM02 Issue Date: Aug. 14, 2013 Page: 3 of 46 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all the…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: EF/2013/70016 FCC ID: XNAWPM02 Issue Date: Aug. 14, 2013 Unless otherwise stated the results shown in thi…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Xavier Debreuil(Product Director)
[email protected]+33 6 0897 9794Fax: +33141460456

Technical Contact

SGS Taiwan LtdWillis Chen
[email protected]886-2-22993279

134, Wu Kung Road, WuKu Industrial Zone · Taiwan

Non-Technical Contact

SGS Taiwan LtdWillis Chen
[email protected]886-2-22993279

Test Firm

SGS Taiwan Ltd.Jason Lin
[email protected]886-2-2299-3279Fax: 886 2 2298 2248

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.70 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Withings

XNAWBS15

Withings BodyScan 2

May 15, 2026

Equipment Class

DTS - Digital Transmission System
XNASCT02

SCT02

Jul 03, 2024

Equipment Class

DTS - Digital Transmission System
XNAWBS14

WITHINGS BODY PRO 2

Jan 25, 2024

Equipment Class

DTS - Digital Transmission System
HWA10 - FCC ID XNAHWA10 - Withings
XNAHWA10

HWA10

Jul 31, 2023

Equipment Class

DTS - Digital Transmission System
Withings Body Scan - FCC ID XNAWBS08 - Withings
XNAWBS08

Withings Body Scan

Apr 03, 2023

Equipment Class

DTS - Digital Transmission System