Operation Instruction I. Main Functions: 1. Six function keys: SNZ, SET, ▼.CF/WAVE,LCD and ALM.. 2. 12/24 hour selectable. 3. °C/°F selectable 4. Indoor temperature range: 0°C--+50°C 5. Outdoor temperature range: -40°C --60°C 6. Outdoor temperature with RF: up to 3 channels 7. Double alarm function 8. Snooze function, ring again after 5 minute later 9. DST function II. Key Function: SET ▼.CF/WAVE SNZ ALM LCD Click Switch display °C/°F switchable Backlight on On/ off alarm Switch the four t zone standard mode Hold enter into time/alarm setting ----- ----- ----- Enter into LCD Brightness setting Click Confirm the Setting one step backward ----- ----- ----- Time set Hold enter into time setting 8steps/second backward ----- ----- ----- Click Confirm the Setting One step Backward ----- ----- ----- Alarm set Hold enter into alarm setting 8steps/second backward ----- ----- ----- III. Instruction of Operating 3.1 RCC singal 1. Press and hold “▼.CF/WAVE “ button for 2 seconds to receive the RC signal manually. The RC symbol is flashing on display. If the reception is successful, the RC symbol is shown on display. 2. “DST “ is shown on display if it is in Daylight Saving Time mode. ( Note : The clock automatically scan the time signal at AM2:00, AM3:00, AM4:00 and AM5:00 ). 3.2 Normal states 1. Click “SET” key to alarm mode. 2. Hold “SET” key to enter into setting mode 3. Click “▼.CF/WAVE” key to switch between °C/°F 4. Press “LCD” key to switch the time zone. 5. Hold “LCD” key for 2 seconds to adjust LCD brightness setting, total 8 levels. 6. Click “ALM” key to switch the alarm on/off 7. When alarm is ringing, click “SNZ” key once to enter into snooze state, the alarm will ring again after 5 minutes 3.3 Time setting 1. Hold “SET” key for 2 seconds to enter into time setting 2. The setting item will flash 1 HZ 3. The sequence of time setting: 12/24HRHourMinuteYe a rMonthDateDST ON/OFFExit 4. Press “SET” key to confirm the setting. Function Operation 5. Press “▼.CF/WAVE” key one time, the setting will go backward for one step; hold the key for 2 seconds, it will run back by 8 steps/second. 6. The system will exit automatically if no key is operated in 15 seconds. And the previous setting will be confirmed automatically . 3.4 Alarm set 1. Hold “SET” key for 2 seconds to enter into alarm setting 2. The setting item will flash 1 HZ 3. The sequence of alarm setting: Hour Minute exit 4. Press “▼.CF/WAVE” one time, the setting will go backward for one step; hold the key for 2 seconds, it will run back by 8 steps/second. 5. Press “ALM” key to confirm the setting 6. The system will exit automatically if no key is operated in 15 seconds. And the previous setting will be confirmed automatically . 7. Press “ALM” key to switch alarm on/off, sequence: AL1 ON/AL2 OFFAL2 ON/AL1 OFFAL1/AL2AL1/AL2 OFF. 8. the BUZZER will ring for 2 seconds as below: a) 0 – 10 sec.: one “BI” per second b) 10 – 20 sec.: two “BI” per second c) 20 – 30 sec.: four “BI” per second d) after 30 sec.: “BI” continuously e) When the alarm is ringing, click “SNZ” key once to enter into snooze state, and ring again after 5 minute later; press other key to exit. IV. Power-On and reset When Power-On and reset, LCD full display for 3 seconds enter the normal state after “Beep” checking temperature receive RF for 3 minutes V.Receiving RF 5.1 The receiving function of RF 1. After installing the battery and checking temperature, it will enter RF receiving state automatically for 3 minutes. I.RCC RECEIVINGV 1. How to enter RCC receiving status: a. It will enter RCC receiving state automatically after powering ON or resetting. b. Hold “ ▼.CF/WAVE” key to enter into RCC receiving status forcibly c. It enters RCC receiving automatically every day. 2. Time of automatic RCC receiving: at 1:00,2:00, 3:00, 4:00, 5:00. It must receive at 1:00,2:00, 3:00 , if it fails to receive until 3:00, it will enter receive status selectable at 4:00 or 5:00, If the reception is successful at 4:00, it will not receive again in a day. Otherwise, it will enter receiving at 5:00.And after that it will not enter the receiving status again whatever successful or not. RCC receiving time is 7 minutes. 3. The displaying of icons during receiving : a. When it enters RCC receiving status, the tower-shaped part of RCC symbol on the LCD will flash in the frequency of 1 Hz. b. When it is receiving the signal, the tower-shaped part of RCC symbol and the curved antenna symbol of RCC will flash in the frequency of 1 Hz. c. When the signal is too weak to be received, the tower shape of RCC will flash in the frequency of 1 Hz, while the curved antenna symbol will not display. d. After receiving the synchronization signal, the RCC symbol will fully display and exit the receiving status. 4. When it is receiving signals, press “ ▼.CF/WAVE” key will exit RCC receiving status, pressing any other key will have no effect. 5. When it fails to receive the signals in a day, it will receive the signal at 2:00 next day. 6. During receiving RCC, if the alarm rings, it will exit RCC receiving status first and change into alarm ringing status. 7. When received DST signal, the it will display the symbol on the LCD 8. When the RCC symbols display fully, the relative RCC icon will be OFF if reset the time. FCC warnings This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installati…
Text truncated - open the document above for the full version.
FCC Confidentiality Request To the FCC and FCC TCB handling this application for certification Pursuant to 47 CFR Section 0.459(a) & (b), we, (the applicant / grantee) Company name FUZHOU RISE ELECTRONIC CO., LTD. Addresss Bldg 15, Zone C, Pushang Industial Area, No.6, Hongjiang RD, Fuzhou, Fujian, China City Fujian Country China request non-disclosure and confidential treatment for our certification under: Grantee Code Product Number FCC ID: XNB TX9 of the following materials submitted within this certification application: (please cross what is applicable, or add other documents) x Operational Description x Block Diagrams x Schematics Diagrams Turn up produrce Bill of Materials Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. We understand that pursuant to 47 CFR section 0.457(d)(1)(ii) disclosure of the applicant and all accompanying documentation will not be made before the date of the grant. Attestation: City and Country: Date: Name: (this must be a person) Function: Signature: (or official company stamp) Fujian, China 2014 -7-28 MARK WANG Manager
APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Photo 1 Photo 2 Photo 3 Photo 4 Photo 5 Photo 6
FCC ID LABELING AND LOCATION FCC ID Label Digital Clock(TX) Model NO.: TX9 Input Rating: DC 3V FCC ID: XNBTX9 IC: 11319A-TX9 FUZHOU RISE ELECTRONIC CO., LTD. Made in China FCC ID Label Location The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925)
Photo 7 Photo 8 Photo 9 Photo 10 Photo 11 Photo 12 Photo 13 Photo 14
FCC RADIO TEST REPORT FCC ID: XNBTX9 IC:11319A-TX9 Product: Digital Clock(TX) Trade Name: N/A Model Name: TX9 Serial Model: N/A Prepared for FUZHOU RISE ELECTRONIC CO., LTD. BBldg 15, Zone C, Pushang Industial Area, No.6, Hongjiang RD, Fuzhou, Fujian, China Prepared by DongGuan Precise Testing Service Co.,Ltd. Room 203-204, 2F, Xinye Building, No.67 Shijing, Guanzhang Road, Dongguan, China Page 2 of 27 Report No.: PT1407158039E ` TEST RESULT CERTIFICATION Applicant’s name................. : FFUZHOU RISE ELECTRONIC CO., LTD. Address ................................. : Bldg 15, Zone C, Pushang Industial Area, No.6, Hongjiang RD, Fuzhou, Fujian, China Manufacture's Name............ : FFUZHOU RISE ELECTRONIC CO., LTD. Address ................................. : Bldg 15, Zone C, Pushang Industial Area, No.6, Hongjiang RD, Fuzhou, Fujian, China Product description Product name ........................... : Digital Clock(TX) Model and/or type reference : TX9 Rating(s) ................................ : DC 3V,0.08mA,0.24mW Standards............................. : FCC Part15.231, RSS-210 Issue 8 Test procedure .............................. ANSI C63.4-2003, RSS-GEN This device described above has been tested by PTS, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of PTS, this document may be altered or revised by PTS, personal only, and shall be noted in the revision of the document. Date of Test............................................: Date (s) of performance of tests .............: Jul. 15,2014 ~ Jul. 25,2014 Date of Issue...........................................: Jul. 28,2014 Test Result...............................................: Pass Testing Engineer : Assistant Technical Manager : Supervisor Authorized Signatory : Jacky Ou / Manager Page 3 of 27 Report No.: PT1407158039E ` Table of Contents Page 1 . SUMMARY OF TEST RESULTS 4 1.1 TEST FACILITY 5 1.2 MEASUREMENT UNCERTAINTY 5 2 . GENERAL INFORMATION 6 2.1 GENERAL DESCRIPTION OF EUT 6 2.2 DESCRIPTION OF TEST MODES 7 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 8 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 9 2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS 10 3 . ANTENNA REQUIREMENT 11 3.1 STANDARD REQUIREMENT 11 3.2 EUT ANTENNA 11 3.3 CONDUCTED EMISSION MEASUREMENT 12 3.3.1 POWER LINE CONDUCTED EMISSION LIMITS 12 3.3.2 TEST PROCEDURE 13 3.3.3 DEVIATION FROM TEST STANDARD 13 3.3.4 TEST SETUP 13 3.2.5 TEST RESULT 14 3.4 RADIATED EMISSION MEASUREMENT 15 3.4.1 RADIATED EMISSION LIMITS 15 3.4.2 TEST PROCEDURE 16 3.4.3 DEVIATION FROM TEST STANDARD 16 3.4.4 TEST SETUP 17 3.4.5 TEST RESULTS (BLOW 30MHZ) 19 3.4.6 TEST RESULTS (BETWEEN 30 – 1000 MHZ) 20 4 . BANDWIDTH TEST 22 4.1 TEST PROCEDURE 22 4.2 DEVIATION FROM STANDARD 22 4.3 TEST SETUP 22 4.4 TEST RESULTS 23 5 . TRANSMITTER TIMEOUT 25 5.1 REQUIREMENTS 25 6 . EUT TEST PHOTO 27 APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Page 4 of 27 Report No.: PT1407158039E ` 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15, Subpart C (15.231) Standard Section Test Item Judgment Remark 15.207 Conducted Emission N/A Note(1) 15.203 Antenna Requirement Pass 15.231& A1.1 Radiated Spurious Emission Pass 15.231& A1.1.3 Occupied Bandwidth Pass 15.231& A1.1.1 Transmitter Timeout Pass NOTE: (1) ” N/A” denotes test is not applicable in this Test Report. Page 5 of 27 Report No.: PT1407158039E ` 1.1 TEST FACILITY NTEK Testing Technology Co., Ltd Add. : 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District, Shenzhen P.R. China. FCC Registration No.:238937; IC Registration No.:9270A-1 CNAS Registration No.:L5516 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 Conducted Emission Test ±1.38dB 2 RF power,conducted ±0.16dB 3 Spurious emissions,conducted ±0.21dB 4 All emissions,radiated(<1G) ±4.68dB 5 All emissions,radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% Page 6 of 27 Report No.: PT1407158039E ` 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Equipment Digital Clock(TX) Model Name TX9 Serial Model N/A Model Difference N/A Product Description The EUT is a wireless transmitter/sensor (temperature and humidity) used with a digital clock. this device is subject to 15.231(e) - periodic transmission Product Type Remote Control Operation Frequency: 434.027MHz Modulation Type: ASK Antenna Designation: extension wire antenna Antenna Gain(Peak) 0 dBi Output Power: 68.63 dBuV/m (AV Max.) Channel List N/A Adapter N/A Battery DC 3V,0.08mA,0.24mW Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2. Table for Filed Antenna Ant . Brand Model Name Antenna Type Connector Gain (dBi) NOTE 1 N/A N/A extension wire Antenna NA 0 Antenna Page 7 of 27 Report No.: PT1407158039E ` 2.2 DESCRIPTION OF TEST MODES To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively. Pretest Mode Description Mode 1 TX For Conducted Emission Final Test Mode Description / / For Radiated Emission Final Test Mode Description Mode 1 TX Note: (1) The EUT use new battery. Page 8 of 27 Report No.: PT1407158039E ` 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED Radiated Spurious Emission Test E-1 EUT Page 9 of 27 Report No.: PT1407158039E ` 2.4 DESCRIPTION OF SUPPORT UN…
Text truncated - open the document above for the full version.
Page 27 of 27 Report No.: PT1407158039E ` 6. EUT TEST PHOTO Radiated Measurement Photos
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231(e) | 434.027 MHz - 434.027 MHz | - |

Digital Clock
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Digital Clock
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Digital Clock(TX)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Digital Clock
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter