Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 5 User Manual Statements m. dudde hochfrequenz-technik Rottland 5a, D-51429 Bergisch-Gladbach DIN EN ISO/IEC 17025 zertifiziert Akkreditiertes Testhaus- Reg.-Nr.: DAT-P-225/96-02 Tel. : +49 22 07 - 96 89 - 0 Fax : +49 22 07 - 96 89 - 20 email: [email protected] www.dudde.com PHOENIX TEST-LAB GmbH Product Certification Königswinkel 10 D 32825 Blomberg Date: 2011-04-19 FCC ID: XTJ920287A IC Certification Number: 8653A-920287A Subject: Compliance Statement in Car Manual Dear Sirs, On behalf of our customer Hirschmann Car Communication, we declare that the product with the above FCC ID / IC certification number is marketed together with cars, where its operation is included in the individual owner’s manual of the car. Our customer assures that the following will be included in a prominent location of the owner’s manual of the car: The title “CAUTION TO USERS” or “FCC WARNING”: “NOTE” or relevant title and “Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.” This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Yours sincerely, m. dudde hochfrequenz-technik Andreas Morsbach Management Assistant
m. dudde hochfrequenz-technik Rottland 5a, D-51429 Bergisch-Gladbach DIN EN ISO/IEC 17025 zertifiziert Akkreditiertes Testhaus- Reg.-Nr.: DAT-P-225/96-02 Tel. : +49 22 07 - 96 89 - 0 Fax : +49 22 07 - 96 89 - 20 email: [email protected] www.dudde.com Request for Confidentiality Date: 2011-05-20 Subject: Certification Application FCC ID:XTJ-920287A Dear FCC TCB: Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, our customer Hirschmann Car Communication GmbH hereby requests confidential treatment of information accompanying as outlined below: Block diagram Block diagram description / Operational description Schematics Parts list The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to Hirschmann Car Communication GmbH and provide unjustified benefits to our competitors. Hirschmann Car Communication GmbH understands that pursuant to Rule 0.457(d)(1)(ii), disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this Application. Thank you for your attention in this matter. m. dudde hochfrequenz-technik Andreas Morsbach Management Assistant
State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 1 External Photographs State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920
State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 4 Label Sample State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Label sample State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Label location
State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 2 Internal Photographs State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920
State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 3 Occupied Bandwidth Plot State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Occupied bandwidth 20 dB bandwidth channel 1 (314.000 MHz) +20° C, 12.0 V DC State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Occupied bandwidth 20 dB bandwidth channel 1 (314.900 MHz) +20° C, 12.0 V DC State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Occupied bandwidth 20 dB bandwidth channel 1 (314.450 MHz) +20° C, 12.0 V DC State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Occupied bandwidth 99 % bandwidth channel 1 (314.000 MHz) +20° C, 12.0 V DC State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Occupied bandwidth 99 % bandwidth channel 1 (314.900 MHz) +20° C, 12.0 V DC State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Occupied bandwidth 99 % bandwidth channel 1 (314.450 MHz) +20° C, 12.0 V DC
State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 11 Transmission Time Operation Characteristics State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Total transmission time (deactivation time) (channel 1) Switch off point State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Total transmission time (deactivation time) (channel 2) Switch off point State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Total transmission time (deactivation time) (channel 3) Switch off point State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Total transmission time (Remote access) (channel 1) first telegram: 5.799 ms second telegram: 5.942 ms worst case transmission in any 100 ms time period during pulse train = 11.741 ms State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Total transmission time (Remote access) (channel 2) first telegram: 5.797 ms second telegram: 5.942 ms worst case transmission in any 100 ms time period during pulse train = 11.739 ms State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Total transmission time (Remote access) (channel 3) first telegram: 5.797 ms second telegram: 5.943 ms worst case transmission in any 100 ms time period during pulse train = 11.740 ms State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Total transmission time (Keyless Go access) (channel 1) first telegram: 10.290 ms second telegram: 7.101 ms third telegram: 3.044 ms worst case transmission in any 100 ms time period during pulse train = 20.435 ms State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Total transmission time (Keyless Go access) (channel 2) first telegram: 10.145 ms second telegram: 7.101 ms third telegram: 3.044 ms worst case transmission in any 100 ms time period during pulse train = 20.290 ms State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Total transmission time (Keyless Go access) (channel 3) first telegram: 10.290 ms second telegram: 7.101 ms third telegram: 3.044 ms worst case transmission in any 100 ms time period during pulse train = 20.435 ms State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Calculating the averaging factor The worst case transmission time per channel is 20.435 ms in a 100 ms time sweep. The averaging factor was calculated by the following formula: averaging factor = 20*lg (TX ON / 100 ms) = 20*lg (20.435 / 100 ms) = -13.7 dB
State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 12 Antenna Characteristics State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920
Test report no. 11006827 Page 1 of 33 EUT: 920287A FCC ID: XTJ-920287A Date of issue: 2011-04-18 State: 2011-02-10 Vers. no.: 1. 11 m. dudde hochfrequenz - technik Rottland 5a D-51429 Bergisch Gladbach Tel. +49 2207-96890 Fax +49 2207 968920 Test Report acc. to FCC Title 47 CFR Part 15 relating to Hirschmann Car Communication GmbH 920287A Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators Measurement Procedure: ANSI C63.4-2009 Test report no. 11006827 Page 2 of 33 EUT: 920287A FCC ID: XTJ-920287A Date of issue: 2011-04-18 State: 2011-02-10 Vers. no.: 1. 11 m. dudde hochfrequenz - technik Rottland 5a D-51429 Bergisch Gladbach Tel. +49 2207-96890 Fax +49 2207 968920 Manufacturer’s details Manufacturer Hirschmann Car Communication GmbH Manufacturer‟s grantee code XTJ Manufacturer‟s address Hirschmann Car Communication GmbH Stuttgarter Straße 45 - 51 D-72654 Neckartenzlingen Germany Phone: +49(0) 7127 14 1027 Fax: +49(0) 7127 14 1232 Email: [email protected] Relevant standard used 47 CFR Part 15C - Intentional Radiators ANSI C63.4-2009 Test report prepared by Technical engineer Ralf Trepper m.dudde hochfrequenz-technik (laboratory) Rottland 5a 51429 Bergisch Gladbach Germany Phone: +49 2207 96890 Fax: +49 2207 968920 Email: [email protected] Equipment Under Test (EUT) Equipment category Transceiver Trade name Hirschmann Type designation 920287A Serial no. --- / Sample no. 920 287 036 Variants --- Test report no. 11006827 Page 3 of 33 EUT: 920287A FCC ID: XTJ-920287A Date of issue: 2011-04-18 State: 2011-02-10 Vers. no.: 1. 11 m. dudde hochfrequenz - technik Rottland 5a D-51429 Bergisch Gladbach Tel. +49 2207-96890 Fax +49 2207 968920 1. Test result summary CFR Section Report Chapter Requirements Headline Test result 15.203 11.1 Antenna requirement Pass Fail N.t. 15.205 11.2 Restricted bands of operation Pass Fail N.t. 15.209 11.3 Radiated emission limits, general requirements Pass Fail N.t. 15.231(a) 11.4 Periodic operation characteristics Pass Fail N.t. 15.231(b) 11.5 Fundamental frequencies / Field strength limits Pass Fail N.t. 15.231(c) 11.6 Bandwidth (20 dB) Pass Fail N.t. The equipment meets the requirements Yes No Signature: .............................. Signature: .............................. (Technician) (Manager) Test report no. 11006827 Page 4 of 33 EUT: 920287A FCC ID: XTJ-920287A Date of issue: 2011-04-18 State: 2011-02-10 Vers. no.: 1. 11 m. dudde hochfrequenz - technik Rottland 5a D-51429 Bergisch Gladbach Tel. +49 2207-96890 Fax +49 2207 968920 Table of contents 1. Test result summary .......................................................................................................................................... 3 2. Test laboratory .................................................................................................................................................. 5 3. Introduction ...................................................................................................................................................... 5 4. Product ............................................................................................................................................................. 6 5. Test schedule .................................................................................................................................................... 6 6. Product and measurement documentation ......................................................................................................... 7 7. Observations and comments ............................................................................................................................. 7 8. Summary........................................................................................................................................................... 7 9. Conclusions ...................................................................................................................................................... 8 10. Operational description ................................................................................................................................... 9 11.1 Antenna requirement ..................................................................................................................................... 10 11.1.1 Regulation ........................................................................................................................................... 10 11.1.2 Result .................................................................................................................................................. 10 11.2 Restricted bands of operation ........................................................................................................................ 11 11.2.1 Regulation ........................................................................................................................................... 11 11.2.2 Result .................................................................................................................................................. 13 11.3 Radiated emission limits, general requirements ............................................................................................ 14 11.3.1 Regulation ........................................................................................................................................... 14 11.3.2 Test equipment ................................................................................................................................... 15 11.3.3 Test procedure .................................................................................................................................... 16 11.3.4 Calculation of the field strength ......................................................................................................... 17 11.3.5 Test result ....…
Text truncated - open the document above for the full version.
State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 Annex no. 6 Test Setup Photographs State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920 State: 2010-03-01 Vers. no.: 1.10 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel. +49 2207-96890 Fax +49 2207 968920
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 3 | 15.231 | 314.9 MHz - 314.9 MHz | - |

Broadcast Reception Amplifier
Equipment Class
JAB - Part 15 Class B Digital Device