
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Standard Motor Products Inc. P1 / P1 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Date: 12/5/2012 Request for Confidentiality Company name: Standard Motor Products, Inc. FCC ID: XVBW1C01 FCC Part 15 Certification To whom it may concern: In accordance with 0.459 of CFR 47, Standard Motor Products, Inc. hereby requests confidentiality of all Block Diagrams, Schematics, Operational Description and internal photos(device is potted) 1 attachments for the subject application. 1. DUT is fully potted using a non-removable epoxy based material. Removal of potting material causes irreparable damage to internal circuitry. These documents contain detailed system and equipment description and related information about the product which Standard Motor Products, Inc. considers to be proprietary, confidential and a custom design and otherwise would not release to the general public. Since the design is a basis from which future technological products will evolve, Standard Motor Products, Inc. considers that this information would be of benefit to its competitors and that the disclosure of the information in these documents would give competitors an unfair advantage in the market.
Registration number: W6M21212-12905-C-1 FCC ID: XVBW1C01 IC: 9368A-W1C01 Worldwide Testing Services (Taiwan) Co., Ltd. Appendix Page 9 of 14 External Photos Registration number: W6M21212-12905-C-1 FCC ID: XVBW1C01 IC: 9368A-W1C01 Worldwide Testing Services (Taiwan) Co., Ltd. Appendix Page 10 of 14
Label Model : TP1-001FCC ID : XVBW1C01 IC : 9368A-W1C01 Standard Motor Products, Inc.
of Applicant: Standard Motor Products, Inc Address: 37-18 Northern Boulevard, Long Island City, New York 11101, United States Tested and Prepared by Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: 930600 Industry Canada filed test laboratory Reg. No. IC 5679A-1 A2LA Accredited No.: 2732.01 Report No.: W6M21212-12905-C-1 6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C. TEL: 886-2-66068877 FAX: 886-2-66068879 E-mail: [email protected] FCC PART 15 SUBPART C / IC RSS-210 TEST REPORT for TPMS Model No.: TP1-001 FCC ID: XVBW1C01 IC: 9368A-W1C01 Registration number: W6M21212-12905-C-1 FCC ID: XVBW1C01 IC: 9368A-W1C01 Worldwide Testing Services (Taiwan) Co., Ltd. Page 1 of 22 TABLE OF CONTENTS 1 General Information........................................................................................................................2 1.1 Notes ..........................................................................................................................................2 1.2 Testing laboratory .......................................................................................................................3 1.2.1 Location ..................................................................................................................................3 1.2.2 Details of accreditation status ................................................................................................3 1.3 Details of approval holder...........................................................................................................3 1.4 Application details ......................................................................................................................4 1.5 Test item .....................................................................................................................................4 1.6 Test standards .............................................................................................................................4 2 Technical test ..................................................................................................................................5 2.1 Summary of test results...............................................................................................................5 2.2 Test environment ........................................................................................................................5 2.3 Test Mode ...................................................................................................................................5 2.4 Test equipment utilized...............................................................................................................6 2.5 General Test Procedure.............................................................................................................10 3 Test results (enclosure) .................................................................................................................11 3.1 Transmission Requirements......................................................................................................12 3.1.1 Limit of Transmission Time ..................................................................................................12 3.1.2 Results for the duration and silent period measurement ......................................................12 3.2 Output Power (Field Strength)..................................................................................................13 3.3 Out of Band Radiated Emissions ..............................................................................................14 3.4 Transmitter Radiated Emissions in restricted Bands ................................................................15 3.5 Spurious Emission radiated, Transmitter ..................................................................................16 3.6 Channel Bandwidth...................................................................................................................18 3.7 Antenna requirement.................................................................................................................19 3.8 Duty Cycle ................................................................................................................................20 3.9 Conducted Measurement at (AC) Power Line..........................................................................21 3.10 Equipment Modification ...........................................................................................................22 Appendix: Diagrams and photos Registration number: W6M21212-12905-C-1 FCC ID: XVBW1C01 IC: 9368A-W1C01 Worldwide Testing Services (Taiwan) Co., Ltd. Page 2 of 22 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. The test results of this test report relate exclusively to the item tested as specified in 1.5. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the Worldwide Testing Services (Taiwan) Co., Ltd. Tester: January 10, 2013 Leon Chueh Date WTS-Lab. Name Signature Technical responsibility for area of testing: January 10, 2013 Danny โฆ
Text truncated - open the document above for the full version.
Registration number: W6M21212-12905-C-1 FCC ID: XVBW1C01 IC: 9368A-W1C01 Worldwide Testing Services (Taiwan) Co., Ltd. Appendix Page 14 of 14 Set Up Photos of Radiated emission
6F., No. 58, Lane 188, Ruey Kuand Rd. ยท Taipei ยท Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 315 MHz - 315 MHz | - |

433MHz TPMS
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
TPMS
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
TPMS
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
TPMS
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
TPM sensor tester
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz