Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Information This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
Shenzhen TCT Co., Ltd. Tel:0755-83392668 email:[email protected] Fax:0755-83392168 Address: 5th Floor, Building D, Yusheng Third Industrial Zone, Jiuwei, Xixiang, Baoan District, Shenzhen Product Name: 5.8G 4dBi Rubber Antenna Product model: TCTQ5800-4V60Z Shenzhen TCT Co., Ltd. Tel:0755-83392668 email:[email protected] Fax:0755-83392168 Address: 5th Floor, Building D, Yusheng Third Industrial Zone, Jiuwei, Xixiang, Baoan District, Shenzhen 1.Technical Specification Electrical Specifications Model TCTQ5800-4V60Z FreqRange 5100-5900MHz Gain 4.5±0.5dBi Horizontal Beamwidth 360 º Vertical Beamwidth 60±15º VSWR ≤1.8 Impedance 50 Ω Polarization vertical Max. Power 50W Connector RP-SMA-J Mechanical Specifications mm(Dimension) 196x21.5x13 mm kg(Weight0) 25g material copper Radome Color Black Radome material PC+PBT Operating temperaturec -40~55 º Shenzhen TCT Co., Ltd. Tel:0755-83392668 email:[email protected] Fax:0755-83392168 Address: 5th Floor, Building D, Yusheng Third Industrial Zone, Jiuwei, Xixiang, Baoan District, Shenzhen 1.Antenna Dimensions Shenzhen TCT Co., Ltd. Tel:0755-83392668 email:[email protected] Fax:0755-83392168 Address: 5th Floor, Building D, Yusheng Third Industrial Zone, Jiuwei, Xixiang, Baoan District, Shenzhen 1. Scope of application The terminal rubber antenna is suitable for wireless transmission such as WLAN WIMAX, and the operating frequency is in the 5G band, which is convenient and quick to use. 2. Electrical performance test test method The measurement block diagram is shown in Figure 1. The antenna test simulation diagram. The antenna far- field test system is a set of equipment that automatically completes the antenna's far-field measurement task under the control of a PC. The microcomputer outputs four control signals to the corresponding servo driver through the interface, respectively controls the movement of the azimuth axis, polarization axis and the polarization axis of the transmitting antenna of the antenna under test, and realizes the control of the 5071B vector network analyzer through the IEEE-488 interface. , complete the collection of the amplitude and phase signals of the antenna under test, and analyze the characteristic parameters of the antenna's far-field radiation field to obtain the antenna direction coefficient (or gain), half-power lobe width, arbitrary level lobe width, zero position and A series of parameters such as the position of each side lobe and the corresponding level value, the zero value depth of the monopulse antenna, and the difference slope. Figure 1 Antenna test block diagram Shenzhen TCT Co., Ltd. Tel:0755-83392668 email:[email protected] Fax:0755-83392168 Address: 5th Floor, Building D, Yusheng Third Industrial Zone, Jiuwei, Xixiang, Baoan District, Shenzhen H- Plane 1. The measurement block diagram is shown in Figure 1. Measurement steps: (1) The antenna under test is aligned with the same polarization as the source antenna, and the antenna under test is connected with the receiver through switching; (2) The antenna under test is rotated 360° around the vertical axis on the test turntable, and the received level is recorded as a function of the angle, and the horizontal beam width of the antenna is obtained from the curve; (3) The antenna under test and the source antenna are rotated 90° at the same time, and the vertical beam width of the antenna can be measured by the same method; (4) In order to express the radiation characteristics of the antenna in a given frequency band, the horizontal and vertical beamwidths of at least three frequency points, high, medium and low, are measured in the working frequency band. The direction diagram of the test is as follows : E- Plane Shenzhen TCT Co., Ltd. Tel:0755-83392668 email:[email protected] Fax:0755-83392168 Address: 5th Floor, Building D, Yusheng Third Industrial Zone, Jiuwei, Xixiang, Baoan District, Shenzhen Standing wave ratio measurement The measurement block diagram is shown in Figure 2. Figure 2 Antenna VSWR measurement block diagram Measurement conditions: The antenna under test should be installed in a free space or simulated free space (no echo chamber) that is relatively free of reflection and far enough away from the measuring equipment and the measuring personnel. The inspection method is as follows: when the antenna under test (including its Bracket structure) move at least half a wavelength in 8 horizontal directions separated by 45°, and when moving up and down by half a wavelength, if the change of the voltage standing wave ratio is less than 10%, the test field is considered to be qualified. Measurement steps: (1) Install the antenna under test in a free space or simulated free space that meets the measurement conditions; (2) The test port uses a short circuit or an open circuit to replace the antenna under test for system calibration; (3) Connect the test port to the antenna under test, and directly read the VSWR or return loss of the antenna under test on the display. The standing wave test data are shown in Table 2 and the standing wave diagram. Shenzhen TCT Co., Ltd. Tel:0755-83392668 email:[email protected] Fax:0755-83392168 Address: 5th Floor, Building D, Yusheng Third Industrial Zone, Jiuwei, Xixiang, Baoan District, Shenzhen VSWR Shenzhen TCT Co., Ltd. Tel:0755-83392668 email:[email protected] Fax:0755-83392168 Address: 5th Floor, Building D, Yusheng Third Industrial Zone, Jiuwei, Xixiang, Baoan District, Shenzhen testing regulations Inspection classification: product inspection is divided into two types: type inspection (routine inspection) and factory inspection (delivery inspection). Type inspection: conduct a comprehensive inspection of the indicators specified in the technical conditions of the product, generally once every two years. Type inspection must be carried out when one of the following situations is encountered: (1) Trial type identification of new products or old products transferred to factories; (2) After the official production, i…
Text truncated - open the document above for the full version.
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2022-8-17> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name Y3H712031202022 7120+3120 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name/Title: Zhao Zude/Majordomo Company: Shenzhen Crystal Video Technology Co.,LTD. Address: F13, F518 Idea Land, Baoyuan Road, Baoan Central Area Shenzhen China Phone: 86-755-26716030 Fax: 86-755-23496331 E-Mail: [email protected]
Shenzhen Crystal Video Technology Co.,LTD. F13, F518 Idea Land, Baoyuan Road, Baoan Central Area Shenzhen China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2022-8-17 To whom it may concern: We, the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: Y3H712031202022 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Zhao Zude/Majordomo Company: Shenzhen Crystal Video Technology Co.,LTD. Address: F13, F518 Idea Land, Baoyuan Road, Baoan Central Area Shenzhen China Phone: 86-755-26716030 Fax: 86-755-23496331 E-Mail: [email protected]
Shenzhen Crystal Video Technology Co.,LTD. F13, F518 Idea Land, Baoyuan Road, Baoan Central Area Shenzhen China UNII Device Declaration Letter To whom it may concern: We have declared below featured for FCC equipment authorization, Device FCC ID: Y3H712031202022 (1) DFS Device: Master Client with Radar detection capability N/A Client without radar detection capability, (2) Active / Passive Scanning , adhoc mode access point capability Frequency Band (MHz) Active Scanning (the device can transmit a probe (beacon)) passive scanning (where the device is can listen only with no probes) Ad Hoc Mode capability Access point capability 5190-5230 Yes No Yes No Yes No Yes No 5755-5795 Yes No Yes No Yes No Yes No (3) Country code selection ability Yes No If yes, pls explain how it was implemented: (4) Meet 15.202 requirement Yes No pls check below : A master device is defined as a device operating in a mode in which it has the capability to transmit without receiving an enabling signal. In this mode it is able to select a channel and initiate a network by sending enabling signals to other devices A client device is defined as a device operating in a mode in which the transmissions of the device are under control of the master. A device in client mode is not able to initiate a network. (5) For client devices that have software configuration control to operate in different modes (active scanning in some and passive scanning in others) in different bands (devices with multiple equipment classes or those that operate on non-DFS frequencies) or modular devices which configure the modes of operations through software, the application must provide software and operations description on how the software and / or hardware is implemented to ensure that proper operations modes cannot be modified by end user or an installer. Apply Does not apply (If apply, pls help to provide explanation on it was implement, and how software was controlled) Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name/Title: Zhao Zude/Majordomo Company: Shenzhen Crystal Video Technology Co.,LTD. Address: F13, F518 Idea Land, Baoyuan Road, Baoan Central Area Shenzhen China Phone: 86-755-26716030 Fax: 86-755-23496331 E-Mail: [email protected]
Page 1 of 6 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Antenna 1 Antenna 2 Antenna 3 Antenna 4 Page 2 of 6 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Page 3 of 6 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 4 Fig. 5 Fig. 6 Page 4 of 6 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Page 5 of 6 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 8 Fig. 9 Page 6 of 6 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 10 Fig. 11
Page1of1FCCID:Y3H712031202022 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L4.0cmx3.0cm) LabelLocation AURORA Model:7120+3120 FCCID:Y3H712031202022
Page 1 of 12 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 12 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 12 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 12 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 12 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 12 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11 Fig. 12 Page 7 of 12 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 13 Fig. 14 Page 8 of 12 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 15 Fig. 16 Page 9 of 12 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 17 Fig. 18 Page 10 of 12 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 19 Fig. 20 Page 11 of 12 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 21 Fig. 22 Page 12 of 12 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 23 Fig. 24
Page 1 of 6 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Maximum Permissible Exposure Report 1. Product Information EUT : AURORA Test Model : 7120+3120 Power Supply : Input: 12V3A For AC Adapter Input: 100-240V~, 50/60Hz, 0.9A Adapter Output: 12V3A, Max 36W Hardware Version : V1.0 Software Version : V1.0 5.2G WLAN Frequency Range : 5180MHz~5240MHz Channel Number : 2 channels for 40MHz bandwidth(5190MHz~5230MHz) Modulation Type : IEEE 802.11ac: OFDM (256QAM, 64QAM, 16QAM, QPSK, BPSK) Antenna Description : Antenna1: External Antenna, 5.0dBi(Max.) Antenna2: External Antenna, 5.0dBi(Max.) Antenna3: External Antenna, 5.0dBi(Max.) Antenna4: External Antenna, 5.0dBi(Max.) 5.8G WLAN Frequency Range : 5745MHz~5825MHz Channel Number : 2 channels for 40MHz bandwidth(5755MHz~5795MHz) Modulation Type : IEEE 802.11ac: OFDM (256QAM, 64QAM, 16QAM, QPSK, BPSK) Antenna Description : Antenna1: External Antenna, 5.0dBi(Max.) Antenna2: External Antenna, 5.0dBi(Max.) Antenna3: External Antenna, 5.0dBi(Max.) Antenna4: External Antenna, 5.0dBi(Max.) Exposure category : General population/uncontrolled environment EUT Type : Production Unit Device Type : Mobile Devices Page 2 of 6 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 2. Evaluation Method Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is ≤ 1.0. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance. 3. Limit 3. 1 Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: Mobile Devices 3. 2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density Page 3 of 6 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 4. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 5. Antenna Information External Antenna can only use antennas certificated as follows provided by manufacturer; Antenna type and antenna number Operate frequency band TX Path Maximum antenna gain Notes External Antenna 5180MHz-5240MHz 4 5 dBi WiFi Antenna External Antenna 5745MHz-5825MHz 4 5 dBi WiFi Antenna Page 4 of 6 FCC ID: Y3H712031202022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 6. Conducted Power [5.2GWIFI Max Conducted Power] Mode Channel Frequency (MHz) An…
Text truncated - open the document above for the full version.
Page 1 of 32 FCC ID: Y3H712031202022 Report No.: LCSA071322163EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for 5.2GWIFI (Conducted Measurement) Product Name: AURORA Test Model: 7120+3120 Environmental Conditions Temperature: 23.9°C Relative Humidity: 52.1% ATM Pressure: 100.0 kPa Test Engineer: Ling Zhu Supervised by: Li Huan Page 2 of 32 FCC ID: Y3H712031202022 Report No.: LCSA071322163EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 26dB Bandwidth TestMode Antenna Channel 26db EBW [MHz] Frequency (MHz) Limit[MHz] Verdict 11AC40SISO Ant1 5190 52.51 5192.850 --- PASS 5230 56.15 5228.914 --- PASS 11AC40SISO Ant2 5190 54.72 5192.382 --- PASS 5230 55.09 5231.836 --- PASS 11AC40SISO Ant3 5190 53.87 5190.000 --- PASS 5230 50.30 5234.116 --- PASS 11AC40SISO Ant4 5190 49.46 5188.818 --- PASS 5230 58.86 5228.488 --- PASS Page 3 of 32 FCC ID: Y3H712031202022 Report No.: LCSA071322163EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs OBW NVNT ac40 5190MHz Ant1 OBW NVNT ac40 5230MHz Ant1 Page 4 of 32 FCC ID: Y3H712031202022 Report No.: LCSA071322163EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs OBW NVNT ac40 5190MHz Ant2 OBW NVNT ac40 5230MHz Ant2 Page 5 of 32 FCC ID: Y3H712031202022 Report No.: LCSA071322163EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs OBW NVNT ac40 5190MHz Ant3 OBW NVNT ac40 5230MHz Ant3 Page 6 of 32 FCC ID: Y3H712031202022 Report No.: LCSA071322163EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs OBW NVNT ac40 5190MHz Ant4 OBW NVNT ac40 5230MHz Ant4 Page 7 of 32 FCC ID: Y3H712031202022 Report No.: LCSA071322163EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Duty Factor (dB) Total Power (dBm) Limit (dBm) Verdict NVNT ac40 5190 Ant1 12.36 0.23 12.59 30 Pass NVNT ac40 5230 Ant1 12.02 0.23 12.25 30 Pass NVNT ac40 5190 Ant2 12.29 0.23 12.52 30 Pass NVNT ac40 5230 Ant2 11.77 0.22 11.99 30 Pass NVNT ac40 5190 Ant3 12.4 0.22 12.62 30 Pass NVNT ac40 5230 Ant3 11.97 0.22 12.19 30 Pass NVNT ac40 5190 Ant4 12.42 0.23 12.65 30 Pass NVNT ac40 5230 Ant4 11.94 0.23 12.17 30 Pass MIMO TestMode Channel Ant 1 [Dbm] Ant 2 [Dbm] Ant 3 [Dbm] Ant 4 [Dbm] MIMO [dBm] Limit [dBm] Verdict 11AC40 5190 12.59 12.52 12.62 12.65 18.62 24.98 PASS 5230 12.25 11.99 12.19 12.17 18.17 24.98 PASS Page 8 of 32 FCC ID: Y3H712031202022 Report No.: LCSA071322163EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Conducted PSD (dBm) Duty Factor (dB) Total PSD (dBm) Limit (dBm) Verdict NVNT ac40 5190 Ant1 -1.9…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15E | 5.75 GHz - 5.79 GHz | 57.30 mW |

wireless video transmitter system
Equipment Class
NII - Unlicensed National Information Infrastructure TX
HD wireless video transmitter
Equipment Class
NII - Unlicensed National Information Infrastructure TX
HD Wireless Video Transmission System
Equipment Class
NII - Unlicensed National Information Infrastructure TX
HD Wireless Video Transmission System
Equipment Class
NII - Unlicensed National Information Infrastructure TX
HD Wireless Video Transmitter
Equipment Class
NII - Unlicensed National Information Infrastructure TX