Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Sustainable Solutions 1. Plug the Remote Control Outlet Adapter into an indoor, grounded wall outlet. 2. Plug an electrical device into the Remote Control Outlet Adapter. 3. Press the remote control to power ON your device as indicated by GREEN LED light on the right side of the remote control. 4. When finished using the device plugged into the Remote Control Outlet Adapter, turn the device OFF as usual. 5. Then press the switch on the remote control to cut OFF standby power to the device. 6. When you want to use the device again, FIRST use the remote control to activate power into Remote Control Outlet Adapter. 7. Then turn ON the device you wish to use. 8. REPEAT steps 4 & 5 as necessary. Stops the wasted electricity that devices generate even when not in use Outlet Adapter Remote Control I N S T R U C T I O N S www.practecol.com sustain save simply ™ & PMS 376c EOAREM-002 125V~60HZ-10A TUNGSTON LOAD..240W REMINDER: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interfer- ence in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help.
FCC ID: YBO-EOAREM-002-C Page 1 of 2 External Picture FCC ID: YBO-EOAREM-002-C Page 2 of 2
FCC ID: YBO-EOAREM-002-C Page 1 of 2 FCC ID LABLE FCC ID: YBO-EOAREM-002-C Page 2 of 2 Label Position EUT Label
FCC ID: YBO-EOAREM-002-C Page 1 of 2 Internal Picture FCC ID: YBO-EOAREM-002-C Page 2 of 2
FCC ID: YBO-EOAREM-002-C Page 1 of 19 EMC TEST REPORT No. SH10040802-002 Applicant : Practecol, LLC 190 Carondelet Plaza Suite 1460, Saint Louis, Missouri, 63105, United States Manufacturer : Ningbo KML Electrical Co., Ltd. Dayandou, Jiangnan Village, Gaoqiao Town, Yinzhou District, Ningbo, Zhejiang, P.R.China. Equipment : Wireless Hand Held Transmitter Type/Model : EOAREM-002-C SUMMARY The equipment complies with the requirements according to the following standard(s): 47CFR Part 15 (2009): Radio Frequency Devices ANSI C63.4 (2003): American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz RSS-210 Issue 7 (June 2007): Low-power Licence-exempt Radiocommunication Devices (All Frequency Bands): Category I Equipment RSS-Gen Issue 2 (June 2007): General Requirements and Information for the Certification of Radiocommunication Equipment Date of issue: May 25, 2010 Prepared by: Reviewed by: Wakeyou Wang (Project Engineer) Daniel Zhao (Reviewer) FCC ID: YBO-EOAREM-002-C Page 2 of 19 Description of Test Facility Name: Intertek Testing Services Limited Shanghai Address: Building No.86, 1198 Qinzhou Road(North), Shanghai 200233, P.R. China FCC Registration Number: 236597 IC Assigned Code: 2042B-1 Name of contact: Steve Li Tel: +86 21 64956565 ext. 214 Fax: +86 21 54262335 ext. 214 FCC ID: YBO-EOAREM-002-C Page 3 of 19 Content SUMMARY ..........................................................................................................................................................1 DESCRIPTION OF TEST FACILITY..........................................................................................................................2 1. GENERAL INFORMATION.............................................................................................................................4 1.1 Applicant Information ......................................................................................................4 1.2 Identification of the EUT .................................................................................................4 1.3 Technical specification.....................................................................................................5 1.4 Mode of operation during the test / Test peripherals used ..............................................5 2. TEST SPECIFICATION...................................................................................................................................6 2.1 Instrument list...................................................................................................................6 2.2 Test Standard....................................................................................................................6 3. FUNDAMENTAL & SPURIOUS EMISSION & RESTRICT BAND RADIATED EMISSION....................................8 3.1 Test limit...........................................................................................................................8 3.2 Test Configuration ...........................................................................................................9 3.3 Test procedure and test setup ...........................................................................................9 3.4 Test protocol...................................................................................................................10 4. DEACTIVATING TIME.................................................................................................................................11 4.1 Test limit.........................................................................................................................11 4.2 Test Configuration .........................................................................................................12 4.3 Test procedure and test setup .........................................................................................12 4.4 Test protocol...................................................................................................................12 5. POWER LINE CONDUCTED EMISSION.........................................................................................................13 5.1 Limit ...............................................................................................................................13 5.2 Test configuration ..........................................................................................................13 5.3 Test procedure and test set up ........................................................................................14 5.4 Test protocol...................................................................................................................15 6. EMISSION BANDWIDTH..............................................................................................................................16 6.1 Test limit.........................................................................................................................16 6.2 Test Configuration .........................................................................................................16 6.3 Test procedure and test setup .........................................................................................16 6.4 Test protocol...................................................................................................................17 7. OCCUPIED BANDWIDTH.............................................................................................................................18 7.1 Test limit.........................................................................................................................18 7.2 Test Configuration .........................................................................................................18 7.3 Test procedure and test setup ..........................................…
Text truncated - open the document above for the full version.
FCC ID: YBO-EOAREM-002-C Page 1 of 16 Test Data FCC ID: YBO-EOAREM-002-C Page 2 of 16 1. Fundamental & Spurious Emission & Restrict band radiated emission Horizontal, PK 0 10 20 30 40 50 60 70 80 Level [dB 礦/m] 30M50M70M100M200M300M500M700M1G Frequency [Hz] x x x x x x MES kml_0521_H2_red MES kml_0521_H2_pre LIM FCC 15 F 3 QP Field Strength QP FCC ID: YBO-EOAREM-002-C Page 3 of 16 0 10 20 30 40 50 60 70 80 Level [dB 礦/m] 332M333M334M335M336M Frequency [Hz] x x x x xx x MES kml_0521_H12_red MES kml_0521_H12_pre LIM FCC 15 F 3 QP Field Strength QP FCC ID: YBO-EOAREM-002-C Page 4 of 16 0 10 20 30 40 50 60 70 80 Level [dB 礦/m] 1G2G3G4G5G6G Frequency [Hz] x x x x MES KML_0521_VV_red MES KML_0521_VV_pre LIM FCC 15 F 3 QP Field Strength QP FCC ID: YBO-EOAREM-002-C Page 5 of 16 Vertical, PK 20 30 40 50 60 70 Level [dB礦/m] 30M50M70M100M200M300M500M700M1G Frequency [Hz] x x x x x x x MES kml_0521_V1_red MES kml_0521_V1_pre LIM FCC 15 F 3 QP Field Strength QP FCC ID: YBO-EOAREM-002-C Page 6 of 16 0 10 20 30 40 50 60 70 80 Level [dB 礦/m] 332M333M334M335M336M Frequency [Hz] x x x x xx x MES kml_0521_V12_red MES kml_0521_V12_pre LIM FCC 15 F 3 QP Field Strength QP FCC ID: YBO-EOAREM-002-C Page 7 of 16 0 10 20 30 40 50 60 70 80 Level [dB 礦/m] 1G2G3G4G5G6G Frequency [Hz] x x x x MES KML_0521_HH_red MES KML_0521_HH_pre LIM FCC 15 F 3 QP Field Strength QP FCC ID: YBO-EOAREM-002-C Page 8 of 16 2. Deactivating time FCC ID: YBO-EOAREM-002-C Page 9 of 16 3. Emission Bandwidth FCC ID: YBO-EOAREM-002-C Page 10 of 16 4. Occupied Bandwidth FCC ID: YBO-EOAREM-002-C Page 11 of 16 5. Duty Cycle Pulse Train of “On” key Ref Lvl 87 dB V Ref Lvl 87 dB V RBW 1 MHz VBW 1 MHz RF Att 10 dB A I2D 1AP Unit dB V SWT 100 ms Center 315 MHz10 ms/ 1VIEW1AP -10 0 10 20 30 40 50 60 70 80 -13 87 1 1 Marker 1 [T1] 64.42 dB V 16.232465 ms 1 [T1] 64.42 dB V 16.232465 ms 1 [T1] 0.08 dB 25.651303 ms Date: 6.MAY.2010 21:48:03 FCC ID: YBO-EOAREM-002-C Page 12 of 16 Ref Lvl 87 dB V Ref Lvl 87 dB V RBW 1 MHz VBW 1 MHz RF Att 10 dB A I2D 1AP Unit dB V SWT 50 ms Center 315 MHz5 ms/ 1VIEW1AP -10 0 10 20 30 40 50 60 70 80 -13 87 1 1 Marker 1 [T1] 64.33 dB V 16.232465 ms 1 [T1] 64.33 dB V 16.232465 ms 1 [T1] 0.07 dB 3.767535 ms Date: 6.MAY.2010 21:49:03 FCC ID: YBO-EOAREM-002-C Page 13 of 16 Pulse Train of “Off” key FCC ID: YBO-EOAREM-002-C Page 14 of 16 FCC ID: YBO-EOAREM-002-C Page 15 of 16 Long Pulse Ref Lvl 87 dB V Ref Lvl 87 dB V RBW 1 MHz VBW 1 MHz RF Att 10 dB A I2D 1AP Unit dB V SWT 5 ms Center 315 MHz500 s/ 1VIEW1AP -10 0 10 20 30 40 50 60 70 80 -13 87 1 1 Delta 1 [T1] -19.80 dB 611.222445 s 1 [T1] 61.36 dB V 3.256513 ms 1 [T1] -19.80 dB 611.222445 s Date: 6.MAY.2010 21:50:43 FCC ID: YBO-EOAREM-002-C Page 16 of 16 Short Pulse Ref Lvl 87 dB V Ref Lvl 87 dB V RBW 1 MHz VBW 1 MHz RF Att 10 dB A I2D 1AP Unit dB V SWT 5 ms Center 315 MHz500 s/ 1VIEW1AP -10 0 10 20 30 40 50 60 70 80 -13 87 2 2 Delta 2 [T1] -11.18 dB 210.420842 s 2 [T1] 52.49 dB V 1.653307 ms 2 [T1] -11.18 dB 210.420842 s Date: 6.MAY.2010 21:51:20 The Duty cycle of “on” key = (10 * 0.61 + 15 * 0.21) / 25.65 = 0.361 The Duty cycle of “off” key = (7 * 0.61 + 18 * 0.21) / 26.25 = 0.307 As a result, the duty cycle of 0.36 is taken into calculation.
FCC ID: YBO-EOAREM-002-C Page 1 of 7 Test Setup FCC ID: YBO-EOAREM-002-C Page 2 of 7 30MHz-1000MHz X axis FCC ID: YBO-EOAREM-002-C Page 3 of 7 Y axis FCC ID: YBO-EOAREM-002-C Page 4 of 7 Z axis FCC ID: YBO-EOAREM-002-C Page 5 of 7 1GHz-6GHz X axis FCC ID: YBO-EOAREM-002-C Page 6 of 7 Y axis FCC ID: YBO-EOAREM-002-C Page 7 of 7 Z axis
Building No.86, 1198 Qinzhou Road(North) · Shanghai · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 315 MHz - 315 MHz | - |

Wireless Hand Held Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Wireless Hand Held Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter