FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. E-Senza Technologies GmbH/
  3. YBSSB100

YBSSB1002.4 GHz Module

E-Senza Technologies GmbH
2.4 GHz Module - FCC ID YBSSB100 - E-Senza Technologies GmbH
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jun 15, 2010
Application Purpose
Original Equipment
Date of Application
Jun 15, 2010
Equipment Note
2.4 GHz Module
Frequency Range
2405.00000000 - 2480.00000000
Company
E-Senza Technologies GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Manual SenzaBlock SB110-NTC E-Senza Technologies GmbH | Bücklestr. 82b | 78467 Konstanz | Germany Tel.: +49 7531 36599- 10, Fax: +49 7531 36599-29 | [email protected] | www.e-senza.de Doc V1.6 Leveraging Power of Wireless ® General Information Notice: This device complies with part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Notice: Changes or modifications made to this equipment not expressly approved by E-Senza Technologies may void the FCC authorization to operate this equipment. This includes but is not limited to modifications of the antenna or use of an antenna not approved by E-Senza Technologies. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. Radiofrequency radiation exposure Information: The radiated output power of the device is far below the FCC radio frequency exposure limits. Nevertheless, the device shall be used in such a manner that the potential for human contact during normal operation is minimized. Leveraging Power of Wireless ® Safety Information In order to ensure the safe use of the product described, you have to read and understand this manual. The following notes provide information on how to use this manual. Explanation of symbols used and signal words The following types of messages provide information about possible property damage and general information concerning proper operation and ease-of-use. The following types of messages provide information about possible property damage and general information concerning proper operation and ease-of-use. SenzaBlock is ESD sensitive ! • Prevent SenzaBlock OEM module or PCB inside the enclosure from touching your clothing. Most clothing is insulative and retains a charge even when you are wearing a wrist strap. • Wear a grounded wrist strap against your skin to eliminate static on your body • Hold SenzaBlock by its enclosure or its edge. If you are removing a pluggable module, use the correct tool. User group of this manual The use of products described in this manual is oriented exclusively to – qualified electricians or persons instructed by them, who are familiar with applicable standards and other regulations regarding electrical engineering and, in particular, the relevant safety concepts. – qualified application programmers and software engineers, who are familiar with the safety concepts of automation technology and applicable standards. E-Senza Technologies accepts no liability for erroneous handling or damage to products from E- Senza Technologies or third-party products resulting from disregard of information contained in this manual. Battery Handling Guidelines • Insert the battery correctly (+/-). • Do not recharge • Do not open or dispose in fire • Do not heat above 100°C • Do not expose contents to water • Do not mix with used batteries or other battery types Not considering the above steps may lead to explosion, leaking of battery and can cause damage! This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. This symbol and the accompanying text alerts the reader to a situation which may cause damage or malfunction to the device, either hardware or software, or surrounding property. This symbol and the accompanying text provide additional information to the reader. It is also used as a reference to other sources of information (manuals, data sheets) on the subject matter, product, etc. Leveraging Power of Wireless ® Content 1 SenzaNET ................................................................................... 1 1.1 Communication in SenzaNET ...................................................... 1 1.2 Network Elements ................................................................... 2 1.2.1 SenzaBlock ............................................................................................. 2 1.2.2 Gateway ................................................................................................ 2 1.2.3 SenzaWMS .............................................................................................. 2 2 SenzaBlock SB110-NTC .................................................................... 2 2.1 Features .............................................................................. 2 2.2 Installation ........................................................................... 2 2.2.1 Mechanical Installation............................................................................... 2 2.2.1.1 Sensor Temperature Grade ..................................................................... 3 2.2.2 Electrical Installation................................................................................. 4 2.2.2.1 Connecting…

Text truncated - open the document above for the full version.

External Photos

CETECOM ICT Services GmbH Test report no.: 1-2029-02-05/10 2010-06-02 Page 50 of 54 8 Photographs of t he E UT Photo 4: Antenna A Photo 5: Antenna B CETECOM ICT Services GmbH Test report no.: 1-2029-02-05/10 2010-06-02 Page 51 of 54 Photo 6: Antenna C Photo 7: Antenna D CETECOM ICT Services GmbH Test report no.: 1-2029-02-05/10 2010-06-02 Page 52 of 54 Photo 8: Photo 9:

Internal Photos

CETECOM ICT Services GmbH Test report no.: 1-2029-02-05/10 2010-06-02 Page 53 of 54 Photo 10: Photo 11: CETECOM ICT Services GmbH Test report no.: 1-2029-02-05/10 2010-06-02 Page 54 of 54 Photo 12:

Test Report

CETECOM ICT Services GmbH Untertürkheimer Straße 6-10 . D-66117 Saarbrücken Phone: +49 (0) 681-598-0 Fax: -9075 RSC-Laboratory 2010-06-02 Page 1 of 54 Accredited testing-laboratory DAR registration number: DGA-PL-176/94-D1 Federal Motor Transport Authority (KBA) DAR registration number: KBA-P 00070-97 Recognized by the Federal Communications Commission Anechoic chamber registration no.: 90462 (FCC) Anechoic chamber registration no.: 3462C-1 (IC) Certification ID: DE 0001 Accreditation ID: DE 0002 Accredited Bluetooth ® Test Facility (BQTF) The Bluetooth word mark and logos are owned by the Bluetooth SIG, Inc. and any use of such marks by Cetecom ICT is under license Test report no. : 1-2029-02-05/10 Type identification : SB100 Applicant : E-Senza Technologies GmbH FCC ID : YBSSB100 Test standards : 47 CFR Part 15 CETECOM ICT Services GmbH Test report no.: 1-2029-02-05/10 2010-06-02 Page 2 of 54 Table of contents 1 G e n e r a l i n f o r m a t i o n . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . 3 1.1 Notes ...................................................................................................................................................................3 1.2 Testing laboratory ...............................................................................................................................................4 1.3 Details of applicant .............................................................................................................................................4 1.4 Application details ..............................................................................................................................................4 2 T e s t s t a n d a r d / s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . 5 3 T e c h n i c a l t e s t s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . 6 3.1 Details of manufacturer .......................................................................................................................................6 3.1.1 Test item......................................................................................................................................................6 3.1.2 EUT operating modes..................................................................................................................................7 3.1.3 Extreme conditions testing values ...............................................................................................................7 4 S u m m a r y o f M e a s u r e m e n t R e s u l t s a n d l i s t o f a l l p e r fo r m e d t e s t c a s e s . . . . . . . . . . . . . . . . . . . . . . . . . . 8 5 R F m e a s u r e m e n t t e s t i n g . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . 9 5.1 Description of test set-up.....................................................................................................................................9 5.1.1 Radiated measurements...............................................................................................................................9 5.1.2 Conducted measurements............................................................................................................................9 5.2 Referenced documents ......................................................................................................................................10 5.3 Additional comments ........................................................................................................................................10 5.4 Antenna gain .....................................................................................................................................................12 5.5 Carrier frequency separation §15.247(a)(1) ......................................................................................................14 5.6 Number of hopping channels §15.247(a) (1) ....................................................................................................15 5.7 Time of occupancy (dwell time) §15.247(a)(1)(iii)...........................................................................................16 5.8 Power Spectral density (Hybrid system in Inquiry mode/Page scan) §15.247(e) .............................................18 5.9 Spectrum Bandwidth of a FHSS System / 20dB Bandwidth §15.247(a)(1)......................................................19 5.10 Maximum output power (conducted) § 15.247 (b) (1) ..................................................................................21 5.11 Max. peak output power (radiated) § 15.247 (b)(1) ......................................................................................23 5.12 Band-edge compliance of conducted emissions §15.247 (d) ........................................................................25 5.13 Band-edge compliance of radiated emissions §15.205 .................................................................................28 5.14 Spurious Emissions - conducted (Transmitter) § 15.247 (c) (1) ...................................................................32 5.15 Spurious Emissions > 30 MHz- radiated (Transmitter) § 15.247 (c)(1)........................................................34 5.16 Spurious Emissions < 30 MHz - Transmitter radiated § 15.209 .............................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

CETECOM ICT Services GmbH Test report no.: 1-2029-02-05/10 2010-06-02 Page 48 of 54 7 Photographs of t he Test Set- up Photo 1: Photo 2: CETECOM ICT Services GmbH Test report no.: 1-2029-02-05/10 2010-06-02 Page 49 of 54 Photo 3:

Contact Information

Applicant

Johannes P Bleuel(Dr)
[email protected]+49753136599Fax: +4975313659929

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]49-681-598-0Fax: 49-681-598-8775

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.16 mW
Modular Type
Limited Single Modular Approval
Confidentiality
Long Term
Grant Notes
Output power listed is peak conducted.

Other Applications from E-Senza Technologies GmbH

2.4 GHz Module - FCC ID YBSSB100-E - E-Senza Technologies GmbH
YBSSB100-E

2.4 GHz Module

Feb 21, 2011

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter