DATE:20/04/2010 Nemko Canada Inc 303 River Road Ottawa, Ontario, Canada K1V 1H2 Attn: Director of Certification Authority to Act as Agent On our behalf, I appoint _ SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD ,5/F,Block 4, Anhua Industrial Zone.,No.8 TaiRan Rd.CheGongMiao,FuTian District, Shenzhen,CHINA.,Hanson Chueng_,. to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko Canada Inc, still resides with _ Shenzhen A-OK Technology Grand Development Co., LTD _3rd Fl,34 East Bldg, Chentian Industry District, Xi’xiang Town, Ban’an Zone, Shenzhen City, Guangdong, China . Dated this 20/04/2010 Agency agreement expiration date: Usually Give 8 - 12 Months By: Zhiwen Tang Signature Printed Title: General Manager On behalf of : Shenzhen A-OK Technology Grand Development Co., LTD Telephone: 0755-27582809
DATE: 20/04/2010 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID:__YC5AC114-01_ Product Name: RF Tranasmitter Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: • Schematics • Block diagram These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Dated this Day of 20 20 2010 By: Zhiwen Tang Signature Printed Title: Quality Engineer On behalf of : Shenzhen A-OK Technology Grand Development Co., LTD Telephone: 0755-27582809
Craftmade International, Inc FCC ID: YC5AC114-01 Model: AC114 This device complies with part 15 of the FCC rule s. Operation is subject to the following two conditions (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Label Location
Working theory of transmitter First you shall put the battery on the correct place. Now you can press the On/Off button on AC114-06, the switch will transmit a high voltage to the encoder IC of remote control, the encoder IC of remote control will trigger 433.92 MHz high frequency transmitter unit to transmit the address code and key value. At the same time, LED will flash; and transmitter will be stop if loosing the button, then LED will turn off.
ISO/IEC17025 Accredited Lab. Report No: FCC 1003166 File reference No: 2010-05-05 Applicant: Shenzhen A-OK Technology Grand Development Co., Ltd. Product: RF Transmitter Model No: AC114 Trademark: N/A Test Standards: FCC Part 15 Subpart C, Paragraph 15.231 Test result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.4&FCC Part 15 Subpart C, Paragraph 15.231 regulations for the evaluation of electromagnetic compatibility Approved By Jack Chung Manager Dated: May 05,2010 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD 5/F,Block 4, Anhua Industrial Zone.,No.8 TaiRan Rd.CheGongMiao,FuTian District, Shenzhen,CHINA. Tel (755) 83448688 Fax (755) 83442996 Report No: 1003166 Page 2 of 29 Date: 2010-05-05 TEST REPORT The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the Shenzhen Timeway Technology Consulting Co .,Ltd. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the Shenzhen Timeway Technology Consulting co .,Ltd to his customer. Supplier or others persons directly concerned. Shenzhen Timeway Technology Consulting co .,Ltd will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The Shenzhen Timeway Technology Consulting co .,Ltd reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement: The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19. The testing quality system of our laboratory meets with ISO/IEC-17025 requirements, which is approved by CNAS. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAS-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAS-CL01 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:1999 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 899988 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.:899988. IC- Registration No.: IC5205A-01 The EMC Laboratory has been registered and fully described in a report filed with the (IC) Industry Canada. The acceptance letter from the IC is maintained in our files. Registration No.: IC 5205A-01. Report No: 1003166 Page 3 of 29 Date: 2010-05-05 TEST REPORT The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the Shenzhen Timeway Technology Consulting Co .,Ltd. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the Shenzhen Timeway Technology Consulting co .,Ltd to his customer. Supplier or others persons directly concerned. Shenzhen Timeway Technology Consulting co .,Ltd will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The Shenzhen Timeway Technology Consulting co .,Ltd reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ................................................................................................ 4 1.1 Test Lab Details................................................................................................ 4 1.2 Applicant Details.............................................................................................. 4 1.3 Description of EUT .......................................................................................... 4 1.4 Submitted Sample............................................................................................. 4 1.5 Test Duration.................................................................................................... 5 1.6 Test Uncertainty.................................................................................................5 1.7 Test By.......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 5 3.0 Technical Details............................................................................................. 6 3.1 Summary of Test Results..................................................................................... 6 3.2 Test Standards.................................................................................................. 6 4.0 EUT Modification............................................................................................. 6 5.0 Power Line Conducted Emission Test...................................................................... 7 5.1 Schematics of the Test........................................................................................ 7 5.2 Test Method and Test Procedure............................................................................ 7 5.3 Configuration of the EUT.................................................................................... 7 5.4 EUT Operating Condition............................…
Text truncated - open the document above for the full version.
3rd Fl,34 East Bldg, Chentian Industry District, · Shenzhen City · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |

style type radio receiver
Equipment Class
CRR - Superregenerative Receiver
Electronic limiter receiver
Equipment Class
CRR - Superregenerative Receiver