Guangdong Welly Electrical Appliances Co., Ltd
Microwave Oven - FCC ID YI4DWC42PXP34 - Guangdong Welly Electrical Appliances Co., Ltd
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Aug 21, 2026
Application Purpose
Original Equipment
Equipment Note
Microwave Oven
Frequency Range
2450.00000000 - 2450.00000000
Company
Guangdong Welly Electrical Appliances Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

MICROWAVE OVEN INSTRUCTION MANUAL C42PXP38 IMPORTANT SAFETY INSTRUCTIONS READ CAREFULLY AND KEEP FOR FUTURE REFERENCE Household use only -A1F 2 SAVE THESE INSTRUCTIONS .IMPORTANT SAFEGUARDS... When using electrical appliances basic safety precautions should be followed, including the following: WARNING – To reduce the risk of burns, electric shock, fire, injury to persons, or exposure to excessive microwave energy: 1. Read all instructions before using the appliance. 2. Read and follow the specific "PRECAUTIONS TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY" found on page 8. 3. This appliance must be grounded. Connect only to properly grounded outlet. See "GROUNDING INSTRUCTIONS" found on page 10. 4. Install or locate this appliance only in accordance with the provided installation instructions. 5. Some products such as whole eggs and sealed containers – for example, closed glass jars – are able to explode and should not be heated in this oven. 6. Use this appliance only for its intended use as described in the manual. Do not use corrosive chemicals or vapors in this appliance. This type of oven is specifically designed to heat, cook, or dry food. It is not designed for industrial or laboratory use. 7. HOT CONTENTS CAN CAUSE SEVERE BURNS. DO NOT ALLOW CHILDREN TO USE THE MICROWAVE. Use caution when removing hot items. 8. Do not operate this appliance if it has a damaged cord or plug, if it is not working properly, or if it has been damaged or dropped. 9. This appliance should be serviced only by qualified service personnel. Contact nearest authorized service facility for examination, repair, or adjustment. 10. Do not cover or block any openings on the appliance. 11. Do not store this appliance outdoors. Do not use this product near water – for example, near a kitchen sink, in a wet 3 basement, near a swimming pool, or similar locations. 12. Do not immerse cord or plug in water. 13. Keep cord away from heated surfaces. 14. Do not let cord hang over edge of table or counter. 15. When cleaning surfaces of door and oven that comes together on closing the door, use only mild, nonabrasive soaps, or detergents applied with a sponge or soft cloth. 16. To reduce the risk of fire in the oven cavity: a. Do not overcook food. Carefully attend appliance when paper, plastic, or other combustible materials are placed inside the oven to facilitate cooking. b. Remove wire twist-ties from paper or plastic bags before placing bag in oven. c. If materials inside the oven ignite, keep oven door closed, turn oven off, and disconnect the power cord, or shut off power at the fuse or circuit breaker panel. d. Do not use the cavity for storage purposes. Do not leave paper products, cooking utensils, or food in the cavity when not in use. 17. Liquids, such as water, coffee, or tea are able to be overheated beyond the boiling point without appearing to be boiling. Visible bubbling or boiling when the container is removed from the microwave oven is not always present. THIS COULD RESULT IN VERY HOT LIQUIDS SUDDENLY BOILING OVER WHEN THE CONTAINER IS DISTURBED OR A UTENSIL IS INSERTED INTO THE LIQUID. 18. Notice for extension cord: a. A short power-supply cord is provided to reduce the risks resulting from becoming entangled in or tripping over a longer cord. b. Longer cord sets or extension cords are available and may be used if care is exercised in their use. c. If a long cord or extension cord is used: 1) The marked electrical rating of the cord set or extension cord should be at least as great as the electrical rating of the appliance; 2) The extension cord must be a grounding-type 3-wire cord; 4 and 3) The longer cord should be arranged so that it will not drape over the counter top or tabletop where it can be pulled on by children or tripped over unintentionally. The following basic precautions should always be followed when using electrical appliance: 1. Read all instructions before using. 2. Make sure the voltage in your living area corresponding to the one shown on the rating label of the appliance. And the wall socket is properly grounded. 3. TO reduce the risk of fire in the oven cavity: a. DO not overcook the food. b. Remove wire twist -ties from paper or plastic bags before placing bags in the oven. c. Do not heat oil or fat for deep drying as the temperature of oil cannot be controlled. d. After use wipe the waveguide cover with a damp cloth, followed by dry cloth to remove any food splashes and grease. Built -up grease may overheat and begin to cause smoke or catch fire. e. If materials inside the oven should smoke or ignite, keep oven door closed, turn oven off and disconnect the power supply. f. Close supervision is necessary when using disposable containers made from plastic, paper or other combustible material. 4. TO reduce the risk of explosion and sudden boiling: a. Do not place sealed containers in the oven. Baby bottles fitted with a screw cap or teat are considered to be sealed containers. b. When boiling liquid in the oven, use the wide -mouthed container and stand about 20 seconds at the end of cooking to avoid delayed eruptive boiling of liquids. c. Potatoes, sausage and chestnut should be peeled or pierced before cooking. Eggs in their shell, whole hard -boiled eggs should not be heated in microwave ovens 5 since they may explode, even after microwave heating has ended. d. The cooked liquid should not be removed out immediately. Several moments should be waited before removing. In order to avoid possible hazards caused by delayed eruptive boiling of 1iquids. e. The contents of feeding bottles and baby food jars are to be stirred or shaken and the temperature is to be checked before consumption, in order to avoid burns. 5. Never operate the oven further if the door or door seals is damaged or the oven is malfunctioned or supply cord is damaged. Return the appliance to the nearest authorised service center for repair and maintenance. Never try to adjust or repair the oven yourself. …

Text truncated - open the document above for the full version.

Attestation Statements

GuangdongWellyElectricalAppliancesCo.,Ltd FushaIndustrialPark,FushaTown,ZhongshanCity,GuangdongProvince,China Tel:+860760-22507015 Email:[email protected] CFR47§2.911(d)(5)(i)AttestationLetter AttestationLetter Date:2026-07-24 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsCFR47§2.911(d)(5)(i)Filing FCCID:YI4DWC42PXP34 GuangdongWellyElectricalAppliancesCo.,Ltdcertifiesthattheequipmentforwhich authorizationissought,isnot “covered”equipmentprohibitedfromreceivinganequipment authorizationpursuanttosection2.903oftheFCCrules. Sincerely, Signature: PrintedName:YanjunGao Title:Engineer

Attestation Statements

GuangdongWellyElectricalAppliancesCo.,Ltd FushaIndustrialPark,FushaTown,ZhongshanCity,GuangdongProvince,China Tel:+860760-22507015 Email:[email protected] CFR47§2.911(d)(5)(ii)AttestationLetter AttestationLetter Date:2026-07-24 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsCFR47§2.911(d)(5)(ii)Filing FCCID:YI4DWC42PXP34 GuangdongWellyElectricalAppliancesCo.,Ltdcertifiesthatasofthedateofthefilingofthe application,theapplicantisnotidentifiedontheCoveredListasanentityproducing“covered” equipment. Wealsocertifythat,asofthedateofthefilingoftheapplication,theequipmentdoesnotutilize cyber-securityoranti-virussoftwarefromKasperskyLab,Inc,oranyofitssuccessorsand assignees,whichisalsoonthe“coveredlist”. Sincerely, Signature: PrintedName:YanjunGao Title:Engineer

Attestation Statements

U.S. AGENT LETTER OF ATTESTATION Date: 2026-07-24 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(7) Filing FCC ID: YI4DWC42PXP34 Guangdong Welly Electrical Appliances Co., Ltd certifies that, as of the date of the filing of the application, Emerson Radio Corp. is our designated U.S. agent for service of process for the above referenced FCC ID. Guangdong Welly Electrical Appliances Co., Ltd accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Emerson Radio Corp. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent and Applicant Information: Name: Emerson Radio Corp. Address: 959 Route 46 East, Suite 210, 2 nd Floor, Parsippany, NJ 07054 United States FRN: 0026321828 Tel.: +1(973)4282436 Email: [email protected] Signed by (printed name): Shaun Tam Signature: Applicant: Guangdong Welly Electrical Appliances Co., Ltd Address:Fusha Industrial Park, Fusha Town, Zhongshan City, Guangdong Province,China FRN: 0019939883 Tel:+86- 0760-22507015 Email: [email protected] Signed by (printed name): Yanjun Gao Signature:

Cover Letter(s)

GuangdongWellyElectricalAppliancesCo.,Ltd FushaIndustrialPark,FushaTown,ZhongshanCity,GuangdongProvince,China Tel:+860760-22507015 Email:[email protected] QA-FR-170-B7/29/2014 FCCAuthorization Date:2026-07-24 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:AgentAuthorization Towhomitmayconcern: WeGuangdongWellyElectricalAppliancesCo.,Ltdtheundersigned,herebyauthorizes ShenzhenAccurateTechnologyCo.,Ltd.toactonitsbehalfinallmattersrelatingto applicationforEquipmentauthorization,includingthesigningofalldocumentsrelating tothesematters.AllactscarriedoutbyShenzhenAccurateTechnologyCo.,Ltd.onour behalfshallhavethesameeffectasourownaction. We,theundersigned,herebycertifythatwearenotsubjecttoadenialoffederalbenefits, thatincludesFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988, 21U.S.C.862. Thisauthorizationisvaliduntilfurtherwrittennoticefromtheapplicant. SincerelyYours, Signature: PrintedName:YanjunGao Title:Engineer

Cover Letter(s)

GuangdongWellyElectricalAppliancesCo.,Ltd FushaIndustrialPark,FushaTown,ZhongshanCity,GuangdongProvince,China Tel:+860760-22507015 Email:[email protected] QA-FR-171-A FCCConfidentialAuthorization Date:2026-07-24 FEDERALCOMMUNICATIONSCOMMISSIONS AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:ConfidentialityRequestregardingapplicationforcertificationof FCCID:YI4DWC42PXP34 InaccordancewithSections0.457and0.459oftheCommission’sRules, GuangdongWellyElectricalAppliancesCo.,Ltdherebyrequestslong-termconfidential treatmentofinformationaccompanyingthisapplicationasoutlinedbelow: BlockDiagram Schematics OperationDescription Theabovematerialscontainproprietaryandconfidentialinformationnotcustomarily releasedtothepublic.Thepublicdisclosureofthesematerialsprovidesunjustified benefitstoitscompetitorsinthemarket. SincerelyYours, Signature: PrintedName:YanjunGao Title:Engineer

Cover Letter(s)

Guangdong Welly Electrical Appliances Co., Ltd Address: Fusha Industrial Park, Fusha Town, Zhongshan City, Guangdong Province, China Email: [email protected] Tel: +86 0760-22507015 Declaration of Difference 2026-07-24 To Whom It May Concern, We, Guangdong Welly Electrical Appliances Co., Ltd hereby declare that details as below: Products tested Name Microwave Oven Model C42PXP38-A1F (FCC ID: YI4DWC42PXP34) Multiple Models N/A □No Difference √Differences as the below Testing Products Multiple Models Details C42PXP38-A1F N/A Same model, the model(C42PXP38-A1F) has two different magnetrons. The magnetron comes from different manufacturers, all parameters are identical. Magnetron 1: 2M286-21TDG Magnetron 2: 2M510H. Notes: Products tested -the products tested by Shenzhen Accurate Technology Co., Ltd. We guarantee all the information provided above is true, and notice that we’ll bear all the consequences caused by any false information or concealing Best Regards, Signature: Printed Name: Gao Yanjun Title: Engineer

External Photos

Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT External Photos External Photos Page 1 / 7 External Photos 3NMF-1 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT External Photos External Photos Page 2 / 7 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT External Photos External Photos Page 3 / 7 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT External Photos External Photos Page 4 / 7 3NMF-2 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT External Photos External Photos Page 5 / 7 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT External Photos External Photos Page 6 / 7 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT External Photos External Photos Page 7 / 7 ***** END *****

ID Label/Location Info

EXHIBITA-FCC ID LABEL AND LOCATION Model: C42PXP38-A1F FCC ID Label FCC ID Label Location Information The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the time purchase (Labeling requirements per 2.295).

Internal Photos

Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 1 / 24 Internal Photos 3NMF-1 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 2 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 3 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 4 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 5 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 6 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 7 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 8 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 9 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 10 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 11 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 12 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 13 / 24 3NMF-2 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 14 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 15 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 16 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 17 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 18 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 19 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 20 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 21 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 22 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 23 / 24 Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM EUT Internal Photos Internal Photos Page 24 / 24 ***** END *****

RF Exposure Info

Shenzhen Accurate Technology Co., Ltd. Report No.: 2604U11040E-EM Rev:A/4.0(2024/11/01) Page 10 of 48 TR-4-E-R005 MAXIMUM PERMISSIBLE EXPOSURE Applicable Standard FCC §18.313, §1.1310, §2.1091 According to subpart §1.1310, systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091) (B) Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f²) 30 30–300 27.5 0.073 0.2 30 300–1500 / / f/1500 30 1500–100,000 / / 1.0 30 f = frequency in MHz; * = Plane-wave equivalent power density; EUT Setup 5CM Measurement Environmental Conditions Temperature: 22.3-22.5 °C Relative Humidity: 51-52 % ATM Pressure: 100.3 kPa Test Engineer: Max Tao Test Date: 2026-06-28 EUT Microwave Survery Meter

Test Report

Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA, or any agency of the Federal Government. The information marked “#” is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included but no need marked. This report cannot be reproduced except in full, without prior written approval of the Company. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. Shenzhen Accurate Technology Co., Ltd. Floor 1, KuMaKe Building, Dongzhou Community, Guangming Street, Guangming District, Shenzhen, Guangdong, China. Tel: +86 755-26503290 Web: www.atc-lab.com Rev:A/4.0(2024/11/01) Page 1 of 48 TR-4-E-R005 TEST REPORT Applicant Name: Guangdong Welly Electrical Appliances Co., Ltd Address: Fusha Industrial Park, Fusha Town, Zhongshan City, Guangdong Province, China Report Number: 2604U11040E-EM FCC ID: YI4DWC42PXP34 Test Standard (s) FCC PART 18 Sample Description Product Name: Microwave Oven Model No.: C42PXP38-A1F Trade Mark: N/A Received Date: 2026-06-05 Report Date: 2026-06-28 Test Result: The EUT complied with the standards above. Prepared and Checked By: Approved By: Homelander Dai Bob.Liao EMC Engineer EMC Engineer Shenzhen Accurate Technology Co., Ltd. Report No.: 2604U11040E-EM Rev:A/4.0(2024/11/01) Page 2 of 48 TR-4-E-R005 TABLE OF CONTENTS DOCUMENT REVISION HISTORY ................................................................................................................ 3 GENERAL INFORMATION ............................................................................................................................ 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ........................................................................ 4 OBJECTIVE ................................................................................................................................................... 4 TEST METHODOLOGY .................................................................................................................................... 4 TEST FACILITY .............................................................................................................................................. 5 MEASUREMENT UNCERTAINTY ....................................................................................................................... 5 OPERATING CONDITION/TEST CONFIGURATION ................................................................................... 6 DESCRIPTION OF TEST CONFIGURATION ......................................................................................................... 6 SPECIAL ACCESSORIES ................................................................................................................................. 6 EQUIPMENT MODIFICATIONS .......................................................................................................................... 6 SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................... 6 EXTERNAL I/O CABLE .................................................................................................................................... 6 CONFIGURATION OF TEST SETUP ................................................................................................................... 6 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................. 7 SUMMARY OF TEST RESULT ..................................................................................................................... 8 TEST EQUIPMENT LIST ............................................................................................................................... 9 MAXIMUM PERMISSIBLE EXPOSURE ...................................................................................................... 10 APPLICABLE STANDARD ............................................................................................................................... 10 EUT SETUP ................................................................................................................................................ 10 MEASUREMENT ........................................................................................................................................... 10 CONDUCTED EMISSIONS .......................................................................................................................... 12 APPLICABLE STANDARD ............................................................................................................................... 12 EUT SETUP ................................................................................................................................................ 12 EMI TEST RECEIVER SETUP ........................................................................................................................ 12 TEST PROCEDURE ...................................................................................................................................... 13 CALCULATION ............................................................................................................................................. 13 TEST DATA ................................................................................................................................................. 13 RADIATION HAZARD MEASUREMENT .................................................................................................... 18 APPLICABLE STANDARD ........................…

Text truncated - open the document above for the full version.

Test Setup Photos

Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM Test Photos Test Photos Page 1 / 6 3NMF-1 Photo of Power Line Conducted Emission Measurement Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM Test Photos Test Photos Page 2 / 6 Radiated Emissions Test View (9kHz-30MHz) Radiated Emissions Test View (30MHz-1GHz) Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM Test Photos Test Photos Page 3 / 6 Radiated Emissions Test View (1GHz-18GHz) Radiated Emissions Test View (Above 18GHz) Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM Test Photos Test Photos Page 4 / 6 3NMF-2 Photo of Power Line Conducted Emission Measurement Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM Test Photos Test Photos Page 5 / 6 Radiated Emissions Test View (9kHz-30MHz) Radiated Emissions Test View (30MHz-1GHz) Shenzhen Accurate Technology Co., Ltd. No.: 2604U11040E-EM Test Photos Test Photos Page 6 / 6 Radiated Emissions Test View (1GHz-18GHz) Radiated Emissions Test View (Above 18GHz) ***** END *****

Contact Information

Applicant

Yanjun Gao(Engineer)
[email protected]Fax: 0760-22507100-1080

Technical Contact

Emerson Radio Corp.Shaun Tam
[email protected]

959 Route 46 East, Suite 210, 2nd Floor · Parsippany, New Jersey, 07054 · United States

Test Firm

Shenzhen Accurate Technology Co., Ltd.Hazel Li
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
1182.45 GHz - 2.45 GHz-
Confidentiality
Long Term

Other Applications from Guangdong Welly Electrical Appliances Co., Ltd

YI4DWT25PXP62

Microwave Oven

Mar 20, 2026

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID YI4DWT30PXP24 - Guangdong Welly Electrical Appliances Co., Ltd
YI4DWT30PXP24

Microwave Oven

Mar 20, 2026

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID YI4DWT30PXP68 - Guangdong Welly Electrical Appliances Co., Ltd
YI4DWT30PXP68

Microwave Oven

Dec 18, 2025

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID YI4DWF20UXP33 - Guangdong Welly Electrical Appliances Co., Ltd
YI4DWF20UXP33

Microwave Oven

Dec 18, 2025

Equipment Class

8CC - Part 18 Consumer Device
Microwave Oven - FCC ID YI4DWC20PXP62 - Guangdong Welly Electrical Appliances Co., Ltd
YI4DWC20PXP62

Microwave Oven

Dec 08, 2025

Equipment Class

8CC - Part 18 Consumer Device