YQD-GL501MGGPS Tracker

Queclink Wireless Solutions Co.,Ltd
GPS Tracker - FCC ID YQD-GL501MG - Queclink Wireless Solutions Co.,Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 01, 2020
Application Purpose
Original Equipment
Date of Application
Feb 28, 2020
Equipment Note
GPS Tracker
Frequency Range
2402.00000000 - 2480.00000000
Company
Queclink Wireless Solutions Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

GL501MG GL501MG_T GL501MG_S User Manual Version: 1.00 GL501MG GL501MG_T GL501MG_S User Manual Contents 0. Introduction .................................................................................................................................. 1 1. Product Overview .......................................................................................................................... 2 1.1. Product Appearance ........................................................................................................... 2 1.2. Key Description................................................................................................................... 2 2. Getting Started .............................................................................................................................. 3 2.1. Opening and Closing the Case ............................................................................................ 3 2.2. Turning on/off the Device .................................................................................................. 3 2.3. Installing a SIM Card ........................................................................................................... 4 3. Installation Precautions ................................................................................................................. 5 4. Troubleshooting and Safety Info ................................................................................................... 6 4.1. Troubleshooting ................................................................................................................. 6 GL501MG GL501MG_T GL501MG_S User Manual 1 0. Introduction GL501MG GL501MG_T GL501MG_S is an IP67 waterproof GNSS tracker that features up to 900 days standby time powered by internal batteries and supports wireless charging. The device is ideal for lot management and other tracking applications that require real-time monitoring on temperature and light. GL501MG GL501MG_T GL501MG_S supports LTE Cat M1/NB1 network on multiple bands for operation in America, Europe, and Oceania with a fallback to GPRS. GL501MG GL501MG_T GL501MG_S User Manual 2 1. Product Overview 1.1. Product Appearance Figure 1. GL501MG GL501MG_T GL501MG_S Product View 1.2. Key Description Table 1. GL501MG GL501MG_T GL501MG_S Key Description Key Functions To power on: Long press for more than 3 seconds To check the device status: Press the key for one time To power off (needs to be configured): Long press for more than 3s after power on Light Alarm Sensor Key LEDs Light Tamper Sensor GL501MG GL501MG_T GL501MG_S User Manual 3 2. Getting Started 2.1. Opening and Closing the Case Figure 2. GL501MG GL501MG_T GL501MG_S Screw Position To open/close the case: Unfasten or tighten the 4 screws at backside. 2.2. Turning on/off the Device Figure 3. GL501MG GL501MG_T GL501MG_S Battery Switch and Key To turn on: Long press the key for more than 3 seconds. To turn off (needs to be configured): Long press for more than 3s after power on. Power Key GL501MG GL501MG_T GL501MG_S User Manual 4 2.3. Installing a SIM Card Figure 4. GL501MG GL501MG_T GL501MG_S SIM Card Holder Power off the device first and then install the SIM card. SIM Card Holder GL501MG GL501MG_T GL501MG_S User Manual 5 3. Installation Precautions  Firmly install the device to a reliable surface to prevent falling off.  Make the side with antenna face sky to have better signal reception.  Do not install the device under metal surface or in enclosed environments having difficulty in getting GPS and network signal. GL501MG GL501MG_T GL501MG_S User Manual 6 4. Troubleshooting and Safety Info 4.1. Troubleshooting Table 2. GL501MG GL501MG_T GL501MG_S Troubleshooting List Trouble Possible Reason Solution After the device is turned on, the Status LED always flashes quickly. The signal is too weak. The device isn’t registered to the network. Please move the device to a place with good network coverage. Messages can’t be reported to the backend server by GPRS. APN is not right. Ask the network operator for the right APN. The IP address or port of the backend server is wrong. Make sure the IP address for the backend server is an identified address in the internet. There is no response from UART when the device is configured by using UART. The port is not ready or the device is not powered on. Please check the port and the device to ensure they are working properly. The device can’t get GPS fix. The GPS signal is weak. Move the device to a place under open sky. It is better to make the side with antenna face the sky. FCC Regulations: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiated radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: GL501MG GL501MG_T GL501MG_S User Manual 7 -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician fo…

Text truncated - open the document above for the full version.

External Photos

Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 1 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG 1. External Photograph of EUT Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 2 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 3 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 4 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 5 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 6 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG 720510

Internal Photos

Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 7 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG 2. Internal Photograph of EUT Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 8 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 9 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 10 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG GNSS Antenna<Rx> WWAN Antenna <Tx/Rx> BLE Antenna<Tx/Rx> Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 11 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 12 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 13 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 14 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 15 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 16 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 17 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 18 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 19 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 20 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG Photographs of EUT Report No.: EP9D1201 Brand Name: Queclink / Model Name: GL501MG, GL501MG_T, GL501MG_S Sporton International (Shenzhen) Inc. Page Number : 21 of 21 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID : YQD-GL501MG

RF Exposure Info

Sporton International (Shenzhen) Inc. Page Number : 1 of 8 TEL : +86-755-86379589 Report Issued Date : Feb. 24, 2020 FAX : +86-755-86379595 Report Version : Rev. 01 FCC ID : YQD-GL501MG RF Exposure Evaluation Report Report No. : FA9D1201 RF Exposure Evaluation Report APPLICANT : Queclink Wireless Solutions Co., Ltd. EQUIPMENT : GPS Tracker BRAND NAME : Queclink MODEL NAME : GL501MG, GL501MG_T, GL501MG_S FCC ID : YQD-GL501MG STANDARD : 47 CFR Part 2.1091 FCC KDB 447498 D01 v06 We, Sporton International (ShenZhen) Inc., would like to declare that the device has been evaluated in accordance with 47 CFR Part 2.1091 and FCC KDB 447498 D01 v06, and pass the limit. Without written approval of Sporton International (ShenZhen) Inc., the test report shall not be reproduced except in full. Reviewed by: Long Liang / Supervisor Approved by: Johnny Chen / Manager Sporton International (ShenZhen) Inc. 1/F, 2/F, Bldg 5, Shiling Industrial Zone, Xinwei Village, Xili, Nanshan, Shenzhen, 518055 People’s Republic of China Sporton International (Shenzhen) Inc. Page Number : 2 of 8 TEL : +86-755-86379589 Report Issued Date : Feb. 24, 2020 FAX : +86-755-86379595 Report Version : Rev. 01 FCC ID : YQD-GL501MG RF Exposure Evaluation Report Report No. : FA9D1201 Table of Contents 1. ADMINISTRATION DATA ........................................................................................................................... 4 1.1. Testing Laboratory ............................................................................................................................. 4 2. DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ............................................................................. 5 3. MAXIMUM RF AVERAGE OUTPUT POWER AMONG PRODUCTION UNITS ........................................ 6 4. RF EXPOSURE LIMIT INTRODUCTION .................................................................................................... 7 5. RADIO FREQUENCY RADIATION EXPOSURE EVALUATION ............................................................... 8 5.1. Standalone Power Density Calculation ............................................................................................. 8 Sporton International (Shenzhen) Inc. Page Number : 3 of 8 TEL : +86-755-86379589 Report Issued Date : Feb. 24, 2020 FAX : +86-755-86379595 Report Version : Rev. 01 FCC ID : YQD-GL501MG RF Exposure Evaluation Report Report No. : FA9D1201 Revision History REPORT NO. VERSION DESCRIPTION ISSUED DATE FA9D1201 Rev. 01 Initial issue of report Feb. 24, 2020 Sporton International (Shenzhen) Inc. Page Number : 4 of 8 TEL : +86-755-86379589 Report Issued Date : Feb. 24, 2020 FAX : +86-755-86379595 Report Version : Rev. 01 FCC ID : YQD-GL501MG RF Exposure Evaluation Report Report No. : FA9D1201 1. Administration Data 1.1. Testing Laboratory Sporton International (Shenzhen) Inc. is accredited to ISO/IEC 17025:2017 by American Association for Laboratory Accreditation with Certificate Number 5145.01. Testing Laboratory Test Firm Sporton International (Shenzhen) Inc. Test Site Location 1/F, 2/F, Bldg 5, Shiling Industrial Zone, Xinwei Village, Xili, Nanshan, Shenzhen, 518055 People’s Republic of China TEL: +86-755-86379589 FAX: +86-755-86379595 Test Site No. FCC Designation No. FCC Test Firm Registration No. CN1256 421272 Applicant Company Name Queclink Wireless Solutions Co., Ltd. Address 3 Floor, Building 2, No.717 Yishan Road, Xuhui District, shanghai, China 200233 Manufacturer Company Name Queclink Wireless Solutions Co., Ltd. Address 3 Floor, Building 2, No.717 Yishan Road, Xuhui District, shanghai, China 200233 Sporton International (Shenzhen) Inc. Page Number : 5 of 8 TEL : +86-755-86379589 Report Issued Date : Feb. 24, 2020 FAX : +86-755-86379595 Report Version : Rev. 01 FCC ID : YQD-GL501MG RF Exposure Evaluation Report Report No. : FA9D1201 2. Description of Equipment Under Test (EUT) Product Feature & Specification EUT Type GPS Tracker Brand Name Queclink Model Name GL501MG, GL501MG_T, GL501MG_S FCC ID YQD-GL501MG Wireless Technology and Frequency Range Bluetooth: 2402 MHz ~ 2480 MHz Mode Bluetooth LE: GFSK Antenna Type / Gain Ceramic Antenna with gain 0.92 dBi HW Version V1.01 SW Version R00A02V10 EUT Stage Production Unit Comments and Explanations: The declared of product specification for EUT presented in the report are provided by the manufacturer, and the manufacturer takes all the responsibilities for the accuracy of product specification. Sporton International (Shenzhen) Inc. Page Number : 6 of 8 TEL : +86-755-86379589 Report Issued Date : Feb. 24, 2020 FAX : +86-755-86379595 Report Version : Rev. 01 FCC ID : YQD-GL501MG RF Exposure Evaluation Report Report No. : FA9D1201 3. Maximum RF average output power among production units <Bluetooth> Mode Maximum Average Power (dBm) Bluetooth LE 6.50 Sporton International (Shenzhen) Inc. Page Number : 7 of 8 TEL : +86-755-86379589 Report Issued Date : Feb. 24, 2020 FAX : +86-755-86379595 Report Version : Rev. 01 FCC ID : YQD-GL501MG RF Exposure Evaluation Report Report No. : FA9D1201 4. RF Exposure Limit Introduction According to ANSI/IEEE C95.1-1992, the criteria listed in Table 1 shall be used to evaluate the environmental impact of human exposure to radio frequency (RF) radiation as specified in §1.1310. The MPE was calculated at 20 cm to show compliance with the power density limit. The following formula was used to calculate the Power Density: 퐒= 퐏퐆 ퟒ훑퐑 ퟐ Where: S = Power Density P = Output Power at Antenna Terminals G = Gain of Transmit Antenna (linear gain) R = Distance from Transmitting Antenna Sporton International (Shenzhen) Inc. Page Number : 8 of 8 TEL : +86-755-86379589 Report Issued Date : Feb. 24, 2020 FAX : +86-755-86379595 Report Version : Rev. 01 FCC ID : YQD-GL501MG RF Exposure Evaluation Report Report No. : FA9D1201 5. Radio Frequency Radiation Exposure Evaluation 5.1. Standalone Power Density Calculation Band Frequency (MHz) Antenna Gain (dBi) Maximum Power (dBm) Maximum EIRP…

Text truncated - open the document above for the full version.

Test Report

Sporton International (Shenzhen) Inc. Page Number : 1 of 33 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID: YQD-GL501MG Report Template No.: BU5-FR15CBT4.0 Version 2.0 FCC RF Test Report Report No. : FR9D1201 FCC RF Test Report APPLICANT : Queclink Wireless Solutions Co., Ltd. EQUIPMENT : GPS Tracker BRAND NAME : Queclink MODEL NAME : GL501MG, GL501MG_T, GL501MG_S FCC ID : YQD-GL501MG STANDARD : FCC Part 15 Subpart C §15.247 CLASSIFICATION : (DTS) Digital Transmission System The product was received on Dec. 12, 2019 and testing was completed on Jan. 16, 2020. We, Sporton International (ShenZhen) Inc., would like to declare that the tested sample has been evaluated in accordance with the test procedures and has been in compliance with the applicable technical standards. The test results in this report apply exclusively to the tested model / sample. Without written approval of Sporton International (ShenZhen) Inc., the test report shall not be reproduced except in full. Reviewed by: Derreck Chen / Supervisor Approved by: Eric Shih / Manager Sporton International (ShenZhen) Inc. 1/F, 2/F, Bldg 5, Shiling Industrial Zone, Xinwei Village, Xili, Nanshan, Shenzhen, 518055 People’s Republic of China Sporton International (Shenzhen) Inc. Page Number : 2 of 33 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID: YQD-GL501MG Report Template No.: BU5-FR15CBT4.0 Version 2.0 FCC RF Test Report Report No. : FR9D1201 TABLE OF CONTENTS REVISION HISTORY .......................................................................................................................................... 3 SUMMARY OF TEST RESULT ......................................................................................................................... 4 1 GENERAL DESCRIPTION .......................................................................................................................... 5 1.1 Applicant ............................................................................................................................................ 5 1.2 Manufacturer ...................................................................................................................................... 5 1.3 Product Feature of Equipment Under Test ........................................................................................ 5 1.4 Product Specification of Equipment Under Test ................................................................................ 5 1.5 Modification of EUT ........................................................................................................................... 5 1.6 Testing Location ................................................................................................................................ 6 1.7 Test Software ..................................................................................................................................... 6 1.8 Applicable Standards ......................................................................................................................... 6 2 TEST CONFIGURATION OF EQUIPMENT UNDER TEST ........................................................................ 7 2.1 Carrier Frequency Channel ............................................................................................................... 7 2.2 Test Mode .......................................................................................................................................... 8 2.3 Connection Diagram of Test System ................................................................................................. 9 2.4 Support Unit used in test configuration and system .......................................................................... 9 2.5 EUT Operation Test Setup .............................................................................................................. 10 2.6 Measurement Results Explanation Example ................................................................................... 10 3 TEST RESULT .......................................................................................................................................... 11 3.1 6dB Bandwidth Measurement ......................................................................................................... 11 3.2 Output Power Measurement ............................................................................................................ 14 3.3 Power Spectral Density Measurement ............................................................................................ 15 3.4 Conducted Band Edges and Spurious Emission Measurement ..................................................... 20 3.5 Radiated Band Edges and Spurious Emission Measurement ........................................................ 25 3.6 AC Conducted Emission Measurement........................................................................................... 29 3.7 Antenna Requirements .................................................................................................................... 31 4 LIST OF MEASURING EQUIPMENT ........................................................................................................ 32 5 UNCERTAINTY OF EVALUATION ........................................................................................................... 33 APPENDIX A. CONDUCTED TEST RESULTS APPENDIX B. AC CONDUCTED EMISSION TEST RESULT APPENDIX C. RADIATED SPURIOUS EMISSION APPENDIX D. DUTY CYCLE PLOTS APPENDIX E. SETUP PHOTOGRAPHS Sporton International (Shenzhen) Inc. Page Number : 3 of 33 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID: YQD-GL501MG Report Template No.: BU5-FR15CBT4.0 Version 2.0 FCC RF Test Report Report No. : FR9D1201 REVISION HISTORY R…

Text truncated - open the document above for the full version.

Test Setup Photos

Sporton International (Shenzhen) Inc. Page Number : E1 of E2 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID: YQD-GL501MG FCC RF Test Report Report No. : FR9D1201 Appendix E. Setup Photographs <Conducted Emission> Sporton International (Shenzhen) Inc. Page Number : E2 of E2 TEL : 86-755-8637-9589 Report Issued Date : Feb. 19, 2020 FAX : 86-755-8637-9595 Report Version : Rev. 01 FCC ID: YQD-GL501MG FCC RF Test Report Report No. : FR9D1201 <Radiated Emission> Y Plane LF HF

Contact Information

Applicant

johnson jiang(Manager)
[email protected]+862151082965Fax: +86 21 54451990

Test Firm

Sporton International Inc. (Shenzhen)Randal Chen
[email protected]+86 0755-86379589

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz4.60 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide separation distance of at least 20 cm from all persons. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Queclink Wireless Solutions Co.,Ltd

YQD-WR310FNA

Industrial Router

Sep 08, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
YQD-WR100LAU

Industrial Router

Jul 30, 2026

Equipment Class

DTS - Digital Transmission System
YQD-GL330MG

GPS Tracker

Jun 04, 2026

Equipment Class

DTS - Digital Transmission System
YQD-GL551MG

GNSS Tracker

May 14, 2026

Equipment Class

DTS - Digital Transmission System
YQD-GES100CG

GNSS Bolt Seal

Jan 05, 2026

Equipment Class

PCB - PCS Licensed Transmitter