FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Inventory Systems GmbH/
  3. YRADO-G1164

YRADO-G1164Pager

Inventory Systems GmbH
Pager - FCC ID YRADO-G1164 - Inventory Systems GmbH
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 07, 2010
Application Purpose
Original Equipment
Date of Application
Nov 07, 2010
Equipment Note
Pager
Frequency Range
915.00000000 - 915.00000000
Company
Inventory Systems GmbH
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

INSTRUCTION MANUAL Monitoring system for atypical removal of products Instruction_manual_monitoring_system_vers10.doc Page 2 of 44 Date: 28.10.2010 Version: 10 1. Data sheet Serial no. Serial no. of the central unit SN: The serial number (1) is listed on top of the sticker label on the back side of the board, directly after the word: “SN” Serial no. Serial no. of the expander module SN: The serial number (2) is listed on top of the sticker label on the back side of the board, directly after the word: “SN” Serial no. Serial no. of the USB-Stick SN: The serial number (3) is listed on the sticker label directly after the word: “SN” Serial no. Serial no. of the pager SN: After switching on the pager, the serial number is displayed for about two sec- onds. Alarms Factory-installed alarms: There are pre-set alarms plus a self-learning fea- ture to adjust alarm levels Location Location of the antenna: Location Location of the central unit: Instruction_manual_monitoring_system_vers10.doc Page 3 of 44 Date: 28.10.2010 Version: 10 Copyright © Any reproduction of the delivered software, of this instruction manual and the exploitation and publication of its contents are subject to our prior written consent. Any infringement will give rise to claims for damages. All rights reserved. These operating instructions describe the functions and the handling of the monitoring sys- tem. We tried to give a description as exactly as possible of the devices and of all the functions. We cannot guarantee the correctness and integrity of the contents of this document, even if we tried hard to do so. We would therefore be grateful at any time to let us have any sugges- tions for improvement or additional ideas. Trademarks and logos The use of a trademark or logo which is not mentioned in this document does not mean that it can be used without any restrictions. Instruction_manual_monitoring_system_vers10.doc Page 4 of 44 Date: 28.10.2010 Version: 10 TABLE OF CONTENTS 1. DATA SHEET .................................................................................................................... 2 2. INTRODUCTION ............................................................................................................... 6 2.1 Symbols used ............................................................................................................... 6 3. INTENDED USE ................................................................................................................ 7 4. SAFETY INSTRUCTIONS ................................................................................................. 8 5. TECHNICAL DATA ......................................................................................................... 10 6. SCOPE OF DELIVERY ................................................................................................... 11 7. DESCRIPTION ................................................................................................................ 13 7.1 Overview...................................................................................................................... 13 8. COMMISSIONING ........................................................................................................... 14 8.1 Installing the monitoring system .............................................................................. 14 8.1.1 Basic information ................................................................................................... 14 8.2 Mounting the central unit and the expander module .............................................. 15 8.3 Cabling the monitoring system ................................................................................. 16 8.4 Pager ........................................................................................................................... 19 8.5 Requirements.............................................................................................................. 20 8.6 Installation of the software IMCo PC Tool ................................................................ 21 9. OPERATION AND DESCRIPTION OF THE SOFTWARE .............................................. 24 9.1 Starting the software IMCo PC Tool and configuring the monitoring system ...... 24 9.1.1 General information ............................................................................................... 24 9.1.2 Starting the software IMCoPCTool ........................................................................ 25 9.2 Adjusting basic settings ............................................................................................ 26 9.2.1 Setting up the connection to the central unit ......................................................... 26 9.2.2 Integration of the connected components ............................................................. 26 9.2.3 Configuration of the expander modules (EXP) ...................................................... 27 9.3 Sending the settings to the central unit ................................................................... 31 9.4 Filling of the system ................................................................................................... 31 Instruction_manual_monitoring_system_vers10.doc Page 5 of 44 Date: 28.10.2010 Version: 10 9.5 Alarm display .............................................................................................................. 32 9.6 Operating modes ........................................................................................................ 33 9.7 Structure of the log file .............................................................................................. 34 9.8 Exit the software ......................................................................................................... 36 10. CLEANING ...................................................................................................................... 37 11. TROUBLE SHOOTI…

Text truncated - open the document above for the full version.

Cover Letter(s)

PHOENIX TEST LAB GmbH Konigswinkel 10 D-32825 Blom berg, Germany Gentlemen, Please be advised that Inventory Systems GmbH authorizes Mr. Marco Janker from EMV TESTHAUS GmbH to act on our behalf for application submittals for FCC Grants of Certification and Industry Canada to PHOENIX TEST LAB GmbH. We certify that we are not subject to denial of federal benefits, including FCC benefits, pursuant to Section 5301 of the Anti Drug Abuse Act of 1988, U.S.C. 862. Further, no party as defined in 47 CFR 1002(b) to the application is subject to the denial of Federal benefits, including FCC benefits. Thank ,///a// *2 Inventory€ystems GmbH tleerstreße 2, D-14052 Berlin T6l. +49(0)90-2000361 24 Fa(. +49(0)9G39788225 Name: Georg Hachmann -??/q/?a-rc

Cover Letter(s)

EMV Briefbogen 2008 ult 30.07.2008 10:39 Uhr Seite 1 Probedruck CMYCMMYCYCMYK Ersteller: U. Rodemeier Revision: 04 Erstelldatum: 03.08.01 Datum: 11.05.07 Seite 1 von 1 Request for Confidentiality PHOENIX TESTLAB GmbH Date: 2010-10-20 Product Certification Königswinkel 10 D 32825 Blomberg RE: Certification Application FCC ID: YRADO-G1164 Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rule, the applicant hereby requests confidential treatment of information accompanying this application as outlined below: • Block Diagram inside document “Block_Diagram_DO-G1164.pdf” • Schematics inside document “Schematics_DO-G1164.pdf” • Technical Description inside document “Technical_Description_DO- G1164.pdf” The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457, disclosure of this application and all accompanying documentation will not be made before the date of the GRANT for this application. Thank you for your attention in this matter. Applicant’s Company address : Inventory Systems GmbH Heerstrasse 2 D-14052 Berlin GERMANY Signature : p.p. Job Title and Dept. : p.p. Marco Janker. EMV TESTHAUS GmbH

Cover Letter(s)

PHOENIX TEST-LAB GmbH Product Certification Königswinkel 10 D 32825 Blomberg To Whom lt May Concern: The FCC statement: "This device complies with Part 15 of the FCG Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation" ls not placed in the label of the equipment due to the following reasons: - Required text is already included in the user guide - After this equipment is assembled, user is not easily able to see FCC text. (Normally the equipment is assembled to "out-of-sight" i.e hide from user. The device name manual is the only end-user visible "part".) This statement is placed in a prominent location in the instruction manual. Position: CEO Company Adress; Heerstrasse 2 D-14052 Berlin Germany Tel.: +49 30 20036124 Fax.: +49 30 200036172 E-M ail : i nfo@ inventorv-svstems. de Thank you for your attention to this matter. Signatory Inventory Systems GmbH Heerstraße 2, D-140S2 Berlin rer. +49(0)@-2000961 24 : Ersteller: D Brandhorst Erstelldatum: 19,11 04 00 19 11 04 Revision Datum: Seite 1 von 1

External Photos

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.01 Inventory Systems GmbH Pager 100393-AU02+W02 Annex C Page 1 of 4 1 Annex C – EUT external pictures 1.1 List of Pictures Picture 1: EUT with USB cable .......................................................................................... 2 Picture 2: EUT (back side) ................................................................................................. 2 Picture 3: EUT (back side) ................................................................................................. 3 Picture 4: EUT ................................................................................................................... 3 Picture 5: EUT ................................................................................................................... 4 Picture 6: EUT ................................................................................................................... 4 Picture 7: EUT ................................................................................................................... 4 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.01 Inventory Systems GmbH Pager 100393-AU02+W02 Annex C Page 2 of 4 Picture 1: EUT with USB cable Picture 2: EUT (back side) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.01 Inventory Systems GmbH Pager 100393-AU02+W02 Annex C Page 3 of 4 Picture 3: EUT (back side) Picture 4: EUT EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.01 Inventory Systems GmbH Pager 100393-AU02+W02 Annex C Page 4 of 4 Picture 5: EUT Picture 6: EUT Picture 7: EUT

Internal Photos

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.01 Inventory Systems GmbH Pager 100393-AU02+W02 Annex B Page 1 of 2 1 Annex B – EUT internal pictures 1.1 List of Pictures Picture 1: PCB bottom side ................................................................................................ 2 Picture 2: PCB top side ..................................................................................................... 2 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.01 Inventory Systems GmbH Pager 100393-AU02+W02 Annex B Page 2 of 2 Picture 1: PCB bottom side Picture 2: PCB top side

Test Report

The test result refers exclusively to the model tested. This report must not be copied without the written authorization by the lab. Revision: 1.0 DGA-PL-224/95-03 / BNetzA-CAB-02/21-02/2 Customer: Inventory Systems GmbH Heerstraße 2 14052 Berlin Tel.: +49 30 200 036 124 Fax: +49 30 200 036 172 RF test report 100393-AU02+W02 Inventory Systems GmbH Pager DO-G1164 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.0 Inventory Systems GmbH Pager 100393-AU02+W02 Page 2 of 40 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Tel.: +49 9421 56868-0 Fax: +49 9421 56868-100 Email: [email protected] Accreditation: Registration number: DGA-PL-224/95-03 CAB (EMC) registration number: BNetzA-CAB-02/21-02/3 FCC facility registration number: 221458 MRA US-EU, FCC designation number: DE0010 Location of Testing: EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany The technical accuracy is guaranteed through the quality management of the EMV TESTHAUS GmbH EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.0 Inventory Systems GmbH Pager 100393-AU02+W02 Page 3 of 40 Table of contents 1 Test regulations ........................................................................................................................ 5 2 Equipment under Test (EUT) .................................................................................................... 6 3 AC power line conducted emissions ......................................................................................... 8 4 Maximum output power .......................................................................................................... 15 5 Power spectral density measurement ..................................................................................... 19 6 6dB spectrum bandwidth measurement .................................................................................. 23 7 Radiated emission measurement (<1 GHz) ............................................................................ 26 8 Radiated emission measurement (>1 GHz) ............................................................................ 32 9 Exposure of humans to RF fields ............................................................................................ 37 10 Equipment calibration status ................................................................................................... 38 11 Measurement uncertainty ....................................................................................................... 39 12 Summary ................................................................................................................................ 40 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.0 Inventory Systems GmbH Pager 100393-AU02+W02 Page 4 of 40 List of pictures Picture 1: Outline of conducted emission test setup ................................................................. 10 Picture 2: Conducted emission on mains, phase 1 (Chart) ....................................................... 11 Picture 3: Conducted emission on mains, phase 1 (Table) ....................................................... 12 Picture 4: Conducted emission on mains, neutral (Chart) ......................................................... 13 Picture 5: Conducted emission on mains, neutral (Table) ......................................................... 14 Picture 6: Test setup for output power measurement ............................................................... 16 Picture 7: Spectrum graph of field strength measurement ........................................................ 18 Picture 8: Test setup for spectral density measurement ........................................................... 20 Picture 9: Spectrum graph of power spectral density measurement ......................................... 22 Picture 10: Test setup for 6dB spectrum bandwidth measurement ........................................... 24 Picture 11: Spectrum graph of 6dB spectrum bandwidth measurement .................................... 25 Picture 12: Test setup for radiated emission measurement (< 1 GHz) ...................................... 28 Picture 13: Radiated emission 30 MHz – 1000MHz .................................................................. 29 Picture 14: Radiated emission 30 MHz – 1000MHz (Table) ...................................................... 30 Picture 15: Radiated emission 30 MHz – 1000MHz (RX mode) ................................................ 31 Picture 16: Test setup for radiated emission measurement (> 1 GHz) ...................................... 34 Picture 17: Radiated emission: Spectrum of radiated emission > 1GHz (pre-scan) .................. 35 Picture 18: Radiated emission: Spectrum of radiated emission > 1GHz (RX mode) ................. 36 List of tables Table 1: Equipment Calibration status ...................................................................................... 38 Table 2: Measurement uncertainty ........................................................................................... 39 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.0 Inventory Systems GmbH Pager 100393-AU02+W02 Page 5 of 40 1 Test regulations CFR 47 Part 2: 01-2010 Code of Federal Regulations Part 2 (Frequency allocation and radio treaty matters; General rules and regulations) of the Federal Communication Commission (FCC) CFR 47 Part 15: 10-2009 Code of Federal Regulations Part 15 (Radio Frequency Devices) of the Federal Communication Commission (FCC) ANSI C63.4: December 2003 American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz RSS-Gen Issue 2 June 2007 General Requirements and Information for the Certification of Radiocommunication Equimpment, published by Industry Canada RSS-102: Issue 4 Mar…

Text truncated - open the document above for the full version.

Test Setup Photos

EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.01 Inventory Systems GmbH Pager 100393-AU02+W02 Annex A Page 1 of 5 1 Annex A – Pictures during test 1.1 List of Pictures Picture 1: Conducted emission test (front) ......................................................................... 2 Picture 2: Conducted emission test (rear).......................................................................... 3 Picture 3: EUT test setup open site for radiated emission test (front) ................................ 4 Picture 4: EUT test setup open site for radiated emission test (rear) ................................. 4 Picture 5: EUT test setup for radiated emission tests ........................................................ 5 EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.01 Inventory Systems GmbH Pager 100393-AU02+W02 Annex A Page 2 of 5 Picture 1: Conducted emission test (front) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.01 Inventory Systems GmbH Pager 100393-AU02+W02 Annex A Page 3 of 5 Picture 2: Conducted emission test (rear) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.01 Inventory Systems GmbH Pager 100393-AU02+W02 Annex A Page 4 of 5 Picture 3: EUT test setup open site for radiated emission test (front) Picture 4: EUT test setup open site for radiated emission test (rear) EMV TESTHAUS GmbH Gustav-Hertz-Straße 35 94315 Straubing Germany Revision: 1.01 Inventory Systems GmbH Pager 100393-AU02+W02 Annex A Page 5 of 5 Picture 5: EUT test setup for radiated emission tests

Contact Information

Applicant

Georg Hachmann
[email protected]+4930200036124Fax: +4930200036172

Test Firm

Element Materials Technology Straubing GmbHChristian Kiermeier
[email protected]49-9421-56868-0Fax: 49-9421-56868-100

Technical Specifications

#Rule PartsFrequency RangePower Output
115C915 MHz - 915 MHz500.00 µW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.

Other Applications from Inventory Systems GmbH

USB Configurator - FCC ID YRADO-G1116 - Inventory Systems GmbH
YRADO-G1116

USB Configurator

Nov 07, 2010

Equipment Class

DTS - Digital Transmission System
Base Unit - FCC ID YRADO-B1829 - Inventory Systems GmbH
YRADO-B1829

Base Unit

Nov 07, 2010

Equipment Class

DTS - Digital Transmission System