User’s Guide 4008-096-897 HTR 0 1 D © Hamaton Hamaton Tire Pressure Monitoring System No.12 East Zhenxing Road Linping, Yuhang District, Hangzhou, China Tel: 0571-89361286 Fax: 0571-89361285 Web: www.hamanton.com.cn Hotline: HANGZHOU HAMATON TYRE VALVES CO., LTD Welcome to Hamaton PRO-TPMS product. The User's Guide is beneficial for you to quickly set up and use TPMS products. Please carefully read the Guide and operate in accordance with it. For more information of Hamaton PRO-TPMS products, please visit www.hamaton.com.cn Content General .........................................................................................................................1 Product View and Parts Information..............................................................................2 Installation of Sensor..................................................................................................3-5 Installation of Receiving Display....................................................................................6 System Settings........................................................................................................7-10 Positioning Settings of Sensor.................................................................................11-12 Settings of Spare Tire...................................................................................................13 Real-time Monitoring Display........................................................................................14 Low Tire Pressure Alarm..............................................................................................14 High Tire Pressure Alarm..............................................................................................15 Quick Air Leakage Alarm..............................................................................................15 Alarm on Low Tire Pressure Prior to Vehicle Start ......................................................16 High Temperature Alarm...............................................................................................16 Alarm on Low Sensor Voltage......................................................................................17 Sensor Failure Alarm....................................................................................................17 Battery Indicator and Charger for Receiving Display....................................................17 Technical Index and Technical Parameter for Hamaton TPMS Product......................18 Terms on After-sale Service for Hamaton TPMS Product............................................19 TPMS is composed by four sensors (five sensors if monitoring for spare tire is necessary) and one receiving display. Sensors are installed inside the tires. They will collect real-time temperature and pressure data of the tires and send the data to the receiving display in wireless way. Meanwhile, the receiving display will accordingly receive the information. In case of abnormal situation (such as air leakage, over high pressure, over low pressure or high temperature etc.), it will give an alarm. In this way, the TPMS can guarantee the driving safety. It is an active protective early warning system for vehicles. Tire Pressure Monitoring System is referred to as TPMS. System introduction General Escape key Menu/confirmation Toggle key Battery cover Plastic foot mini USB interface for charging BOTTOM Receiving display 2 1 Working station indicator for system Battery charging indicator for receiving display Display screen Dynamic graphic of tire location Display of tire location Display of abnormal tire station Display of tire pressure value Display of electric quantity of receiving display Display of temperature inside the tire Introduction on display of receiving display's screen Schematic diagram of TPMS's operating principle Sensor 1 Sensor 2 Sensor 3 Sensor 4 Wireless data transmission Solar PanelTOP Product View and Parts Information LEFT FRONT High Pressure 3.4 Bar 22 °C Successively dismantle the tire, screw out the valve core of tire valve and make the tire deflated. Loosen outer surface of the tire toward to the tire valve with tire changer and then loosen the inner surface of the tire. Strip the tire from the wheel frame. Dismantle the original tire valve on wheel frame. Clean up the hole of wheel frame and inner surface of wheel frame, so as to remove the impurity and dirt (it is suggested that coat a thin layer of soapy water or silicone oil on the hole of wheel frame). Select the sensor in corresponding location in accordance with installation location of the tire. If the sensor with impact aluminium tire valve is used, screw out the nut firstly. Then make the tire valve of the sensor pass through the hole of wheel frame from inside to outside. During installation, make sure that the rubber gasket and the hole of tire frame are perfectly matched and the plane of the sensor is parallel to wheel frame. Finally, screw down the nut. The nut shall be made to the required torque rating with socket sets used for settings on torque value. The defined torque value of Hamaton sensor is 44.25ibf-in or 5N.m. If the sensor with clip-on rubber tire valve is used, utilize professional tool for tire valve to pull tire valve and sensor into the hole of wheel frame. Pay attention to protect sensor while pulling in. After pull them into the hole, make sure that the plane of the sensor is parallel to wheel frame and the hole of tire frame in the locating ring of the tire valve is wholly exposed. * Professional tire installation and maintenance equipment is required for the sensors of the system. Therefore, it is suggested that you go to professional tire shops for installation. 1 STEP 2 STEP 3 STEP Installation of Sensor 4 STEP 5 STEP 6 STEP Paint lubricating agent on contact surface between tire and wheel frame. Then assemble the tire into wheel frame. 43 Installation of Sensor Installation of Battery Open the batt…
Text truncated - open the document above for the full version.
Hangzhou Hamaton Tyre Valves Co., Ltd. 12 East Zhenxing Road, Linping, Yuhang, Hangzhou, China Tel: 86-571-86159905 Fax: 86-571-86159905 FCC Authorization Date: 2013-07-11 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Hangzhou Hamaton Tyre Valves Co., Ltd. , the undersigned, Hereby authorizes Bay Area Compliance Laboratories Corporation to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp. our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature: Weibo Zhang Quality Supervisor
Hangzhou Hamaton Tyre Valves Co., Ltd. 12 East Zhenxing Road, Linping, Yuhang, Hangzhou, China Tel: 86-571-86159905 Fax: 86-571-86159905 FCC Confidential Authorization Date: 2013-07-11 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Confidentiality Request regarding application for certification of FCC ID: Z27HTRD01 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Detailed Circuit Schematics of EUT--- (Long term) Block Diagram--- (Long term) Circuit Description--- (Long term) The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely Yours, Signature: Weibo Zhang Quality Supervisor
EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS EUT – Top View EUT – Bottom View EUT –Right Side View EUT –Left Side View
EXHIBIT A - FCC ID LABELING AND LOCATION FCC ID Label FCC ID Label Location The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase (Labeling requirements per 2.925) Label Here
EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS EUT –Battery Cover Off View EUT – Battery Off View EUT –Solar Panel Cover Off View EUT – Top Cover Off View EUT –Main Board Off View EUT – Main Board Top View EUT –Main Board Bottom View EUT – Screen Board Top View Antenna EUT – Screen Board Bottom View EUT – Power Board Top View EUT – Power Board Bottom View EUT – Battery View
Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP*, or any agency of the Federal Government. * This report may contain data that are not covered by the NVLAP accreditation and shall be marked with an asterisk “★” (Rev.2). This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. FCC PART 15B TEST REPORT For Hangzhou Hamaton Tyre Valves Co., Ltd. 12 East Zhenxing Road, Linping, Yuhang, Hangzhou, China Report Type: Original Report Product Type: TPMS Receiver Test Engineer: Allen Qiao Report Number: R2SH130402051-00 Report Date: 2013-07-10 Reviewed By: Ivan Cao RF Leader Test Laboratory: Bay Area Compliance Laboratories Corp. (Dongguan) No.69 Pulongcun, Puxinhu Industrial Zone, Tangxia, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn FCC ID: Z27HTRD01 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: R2SH130402051-00 FCC Part15B Page 2 of 13 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 3 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 3 OBJECTIVE ................................................................................................................................................................... 3 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................. 3 TEST FACILITY ............................................................................................................................................................. 3 SYSTEM TEST CONFIGURATION .......................................................................................................................... 4 JUSTIFICATION ............................................................................................................................................................. 4 EUT EXERCISE SOFTWARE .......................................................................................................................................... 4 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 4 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 4 EXTERNAL CABLE ........................................................................................................................................................ 4 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 5 SUMMARY OF TEST RESULTS ............................................................................................................................... 6 FCC §15.109 - RADIATED EMISSIONS ................................................................................................................... 7 MEASUREMENT UNCERTAINTY .................................................................................................................................... 7 EUT SETUP .................................................................................................................................................................. 7 EMI TEST RECEIVER SETUP ......................................................................................................................................... 8 TEST PROCEDURE ........................................................................................................................................................ 8 CORRECTED AMPLITUDE & MARGIN CALCULATION ................................................................................................... 8 TEST EQUIPMENT LIST AND DETAILS ........................................................................................................................... 9 TEST RESULTS SUMMARY ............................................................................................................................................ 9 TEST DATA .................................................................................................................................................................. 9 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: R2SH130402051-00 FCC Part15B Page 3 of 13 GENERAL INFORMATION Product Description for Equipment under Test (EUT) The Hangzhou Hamaton Tyre Valves Co., Ltd.’s product, model number: HTRD01 (FCC ID: Z27HTRD01) (the "EUT") in this report was a TPMS Receiver, which was measured approximately: 9.0 cm (L) x 9.0 cm (W) x 5.0 cm (H), rated input voltage: DC 3.7 V from lithium battery or DC 5V form car charger. * All measurement and test data in this report was gathered from production sample serial number: 130402051 (Assigned by BACL.Dongguan). The EUT was received on 2013-04-03. Objective This report is prepared on behalf of Hangzhou Hamaton Tyre Valves Co., Ltd. in accordance with Part 2, Subpart J, Part 15, Subparts A and B of the Federal Communication Commissions rules. The objective of the manufacturer is to determine compliance with FCC Part 15B, Class B. Related Submittal(s)/Grant(s) No related submittal grant. Test Facility The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located on the No.69 Pulongcun, Puxinhu Industrial Zone, Tangxia…
Text truncated - open the document above for the full version.
EXHIBIT D - TEST SETUP PHOTOGRAPHS Radiated Emission -Front View (Below 1GHz) Radiated Emission - Rear View (Below 1GHz) Radiated Emission -Front View (Above 1GHz) Radiated Emission - Rear View (Above 1GHz)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 315 MHz - 315 MHz | - |

TPMS Sensor
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
TPMS Sensor
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
TPMS Sensor
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
TPMS Sensor
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
TPMS Sensor
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter