Z3GITA1HUBITA-1

iTextAlert LLC
ITA-1 - FCC ID Z3GITA1HUB - iTextAlert LLC
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 23, 2012
Application Purpose
Original Equipment
Date of Application
Jan 23, 2012
Equipment Note
ITA-1
Frequency Range
2412.00000000 - 2462.00000000
Company
iTextAlert LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

Operational Description

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Quick Start Guide Model iTA-1 Rev. A iTextAlert, LLC 111 East First Street Geneseo, Illinois 61254 Customer Service: 855-810-2992 www.iTextAlert.com Setup Wizard Power On Install included Li-ion battery into Hub. Connect the included AC power adapter to Hub. 1 Activation Log into www.iTextAlert.com or call 855-810-2992 to activate the system. Once activation has been completed, follow the on-screen instructions. 2 Hub Name Enter a name or identifier for the Hub. This is the identifying name that you (and your designated contacts) will receive SMS (text) messages from on your cell phone. 5 Password You have the option to create a four-digit password that would allow only you to make changes to the system settings. 3 Sensors Connect sensors to the Hub via the provided USB cable and follow on-screen instructions to synchronize the sensors with the Hub. 6 Wi-Fi Connecting to a Wi-Fi network provides a second method for the Hub to transmit alerts to your cell phone. If there is no Wi-Fi network or the network 4 Contacts Enter the name(s) and cell phone number(s) of those persons that are to be notified of any alerts via SMS (text) messaging. 7 REF. DOC. QS-ITA1 REV A, 10/2011 FCC ID: Z3GITA1HUB becomes disabled, the Hub will transmit alerts using the cellular telephone network. The Hub can only connect to one Wi-Fi network. Welcome, Thank you for purchasing the iTA-1 monitoring and alerting system. With this product, you have the ability to monitor up to 8 remote sensing devices using wireless technology and the convenience of your cell phone. The iTA-1 allows you to receive alerts from and to send commands to your Hub via SMS (text) messaging. To begin using your system, please register either logging into www.iTextAlert.com or calling 855-810-2992. Please note that the activation reminder will be present on your Hub until it has been registered. You will not receive SMS alerts to your cell phone until you have completed activation. For customer service or technical support, please call 855-810- 2992 between the hours of 7:00 AM to 7:00 PM Central time zone, Monday through Friday or visit us at www.iTextAlert.com. Activation Per FCC 15.21 changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Per FCC 15.19(a)(3) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Hard Key Functions • Press and hold hard for 5 seconds to place Hub in sleep mode. • Press and release the hard key to wake the Hub from sleep mode. (Note: Do not hold the hard key down.) If the system shuts down, use a paperclip to hit the Reset button on the back side of the Sensor. Push in carefully until the button clicks. Hub Hard Key The hard key is used to put the Hub in sleep mode, wake the Hub up from sleep mode, and reboot the system. The Hub will only power down when the battery pack is depleted. Installing The Sensor’s Battery Remove screw from back battery cover. 1 Slide battery cover to access battery area. 2 3 Insert battery according to diagram. Hub & Sensor Item List 1 - iTextAlert Hub with built-in power Sensor (control panel) 2 - mounting screws 1 - Rechargeable Li-ion battery (3.7V, 1150 mAh, 4.3 Wh) 1 - AC power supply (Input: 110-120V, 50-60 Hz, 0.15A Output: 5V, 1A) 1 - USB cable 1 - USB plug (to protect the port) 1 - wall mount or desk stand bracket 2 - pieces of double-sided tape Quick Start Guide Items included with the optional Sensor packages: 1 - wall mount bracket 1 - USB plug (to protect the port) 2 - mounting screws 1 - AA or AAA battery 2 - piece of double-sided tape Quick Start Guide Open/Close Sensor Temperature Sensor Wet/Dry Sensor Stationary/Move Sensor Wall Mount Installation (Hub and Sensors) Use the mounting bracket as a template to mark pilot holes for the mounting screws. Pilot holes may not be necessary in some materials 1 Sensor wall mountiText Hub wall mount Drill 1/16” pilot holes. Install the mounting bracket using the included screws. 2 Fasten the Hub or Sensor to the bracket. The double-sided tape may be used to fasten the mounting bracket instead of securing with the screws. 3 Installing The Hub’s Battery Slide Hub cover to access battery area. 1 Pull battery tab from battery. 2 Plug in supplied AC power adapter to Hub. 4 Replace battery and cover on Hub. 3 Note: the Hub will not operate without the battery installed. Please install battery prior to operating the device. Note: please push on the power button to access the hard key. Note: Hub must have battery installed and AC adapter plugged in to opterate. Please cut along the dotted lines for a quick reference sheet. Remote Configuration Commands: You can send a SMS command to the Hub. XY Command Sensor 1Y - Disarm 2Y - Arm 3Y - Dismiss ex. Send “25” will Arm Sensor 5 (Kitchen) Sensor Screen Grid Number Reply Commands Sensor List The commands allow you to communicate with your Hub via SMS on your mobile device. 3 or MENU - Option Menu 4 or DISARM - Disarm System 5 or ARM - Arm System 6 - Reply to see Disarmed Sensor List 7 - Reply to see Armed Sensor List 8 or STATUS - Reply Sensor Disarmed/Armed Status 9 or TEST - Send Test SMS to all contacts 11 to 19 - Disarm individual Sensor 21 to 29 - Arm individual Sensor 31 to 39 - Dismiss individual Sensor SMS Notifications Stationary/Move - alerts once the Sensor is physically moved. Open/Close - alerts once the Sensor disconnects/connects. Temperature - alerts once the Sensor has reached its threshold. Wet/Dry - alerts the Sensor has reached the wet/dry level based on its configuration. Power - alerts once the Hub has lost or regained power. Sensor Types SMS signal strength Wi-Fi strength Hub battery level Settings confirmation Incoming SMS Outgoing SMS Entire system Other Grap…

Text truncated - open the document above for the full version.

Cover Letter(s)

Northwest EMC TCB Compliance Opinion Rev. 7/1/10 ITEX0001 Information about the Applicant Grantee (Company Name) iTextAlert LLC FCC Contact Person Scott Rubins Address 111 East First Street City, State, Zip Geneseo, IL 61245 Job Number ITEX0001 Model ITA-1 FCC ID Z3GITA1HUB Agent Rick Trueblood Approval Type Original Equipment Class DTS Digital Transmission System Rule Part 15.247 (15C) Overview The ITA-1 is a home monitoring system hub which communicates with several sensors which report on various functions within the home. The sensors contain Zigbee radios. The ITA-1 Hub contains an 802.11 b/g/n radio , a Zigbee radio and a previously certified cellular radio module FCC ID: XPYLEONG100. Confidentiality requested for allowed files. Request is properly addressed and referenced. Recommendation All items have been resolved and completed to my satisfaction; therefore I recommend this application for approval. Signature Dave Tolman, TCB Committee 1/23/2012

External Photos

FCC Label goes in this recessed pocket Screw inserted here to finalize assembly Hooks for hanging on wall bracket. Battery connector protrudes through cutout in pocket Bumps to retain battery door #2x1/4”flat head plastite screw (Qty 1) Rechargeable battery pack custom made by Palladium Energy, Li-Ion 3.7V 1150mAh Hooks on battery door engage with “shelves” in rear housing battery pocket Recesses in battery door engage with bumps on rear housing to retain battery door Battery door slides on and snaps in place iTextAlert ITA-1 Hub, Front View iTextAlert ITA-1 Hub, Top View iTextAlert ITA-1 Hub, Bottom View iTextAlert ITA-1 Hub, Left Side View iTextAlert ITA-1 Hub, Right Side View ITA-1 Hub Assembly, Top-Front View ITA-1 Hub Assembly, Front-Right View ITA-1 Hub Assembly, Bottom-Front View ITA-1 Hub Assembly, Rear Iso View Wall mount bracket Reverse view showing how hooks on housing engage with tabs on mounting bracket CUI Wall Adapter Reverse view showing wall adaptor plug connected to Hub USB cable provided for configuring sensors View showing USB cable connected to Hub and Sensor for the purpose of configuring the sensor

ID Label/Location Info

CONFORME AU STANDART UL 2017 CERT. TO CAN/CSA STD. C22.2 NO.205 SIG NALEMENT DE TYPE NM NON-D’URGENCE ITA- 1 MONITORING HUB MODELE NO: ITA- 1 REV: A ADAPTEUR: 120VAC, 60HZ, 0.3A PIL ES RECHARGEABLES: LI -IO N 3.7V, 1150 MAH, 4.3WH UTILI SEZ SEULEMENT L ES ADAPTEURS APPROUVES OU PIL ES APPROVEES ITA- 1 MONITORING HUB MODEL NO: ITA- 1 REV: A ADAPTER: 120VAC, 60HZ, 0.3A RECHARGABLE BATTERY LI -IO N 3.7V, 1150 MAH, 4.3WH USE O NLY APPROVED ADAPTER & BATTERY CONFORMS TO UL STD. 2017 CERT. TO CAN/CSA STD. C22.2 NO. 205 NON-EMERGENCY SIG NALI NG TYPE NM FCC ID: Z3GITA1HUB 4003853 CONTAINS FCC ID: XPYLEONG100 REF. DOC. QS-ITA1 REV A, 10/2011 Part Number: Hub Label Ticket Number: TBD Size: 1.57“W x 0.98”T Corner Radius: 0.0156” Artist: MAR Date: 12/19/11 7541286 Die line does not print PLEASE REVIEW & RESPOND AS SOON AS POSSIBLE. DELAYS IN RECEIVING YOUR PROOF RESPONSE MAY EFFECT YOUR DELIVERY DATE. F055 Art Approval Rev.B 04/01/2008 Revision #12345678 Revision Date 12/29 * IMPORTANT NOTE ABOUT INKJET PRINTING: Inkjet printers use process colors (CMYK) to simulate PANTONE ® spot colors. Please refer to the PANTONE ® Solid to Process color guide for an accurate representation of spot colors. WEB DIRECTION / UNWIND 12345768 ATTENTION: If electronic artwork has not been supplied in a standard graphic arts program format, our art department has reproduced the graphics and determined specifications for this part to the best of their ability. Final approval is the customers responsibility. Please be sure to check closely for print position, dimensions, tolerances, colors and text accuracy. 13425786 Reverse view showing wall adaptor plug connected to Hub

Operational Description

Antenna on ITA-1 Radiator for U-Blox (GSM) Plastic carrier Shared radiator for ZigBee and Atheros WiFi Antenna Assembly, part number: 8600-0000-50 (custom part for this product) Manufacturer: Sunshine Precision Mold & Molding Engineering Ltd Antenna Assembly construction: Submitted by: iTextAlert LLC, Rick Trueblood I TA-1: Close-up view of radiator for GSM Nickel-silver radiator adhesively attached to plastic carrier. Carrier snaps onto pcb and radiators are hand soldered. Peak gain: 1.8 dBi Submitted by: iTextAlert LLC, Rick Trueblood Antenna Assembly, part number: 8600-0000-50 (custom part for this product) Manufacturer: Sunshine Precision Mold & Molding Engineering Ltd I TA-1: Close-up view of shared radiator for ZigBee and WiFi Nickel-silver radiator adhesively attached to plastic carrier. Carrier snaps onto pcb and radiators are hand soldered. Peak gain: 3.4 dBi Submitted by: iTextAlert LLC, Rick Trueblood Antenna Assembly, part number: 8600-0000-50 (custom part for this product) Manufacturer: Sunshine Precision Mold & Molding Engineering Ltd

RF Exposure Info

ItextAlert LLC ITA-1 Report No. 7LAY0059.3 Report Prepared By www.nwemc.com 1-888-EMI-CERT © 2012 Northwest EMC, Inc 22975 NW Evergreen Parkway Suite 400 Hillsboro, Oregon 97124 Certificate of Evaluation ITextAlert LLC Model: ITA-1 Emissions Test Description Specification Test Method Pass/Fail Maximum Permissible Exposure FCC 2.1091:2011 OET Bulletin 65, Supplement C Ed 01-01 Pass Modifications made to the product See the Modifications section of this report Approved By: Donald Facteau, IS Manager This report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government of the United States of America. Product compliance is the responsibility of the client, therefore the tests and equipment modes of operation represented in this report were agreed upon by the client, prior to testing. This Report may only be duplicated in its entirety. The results of this test pertain only to the sample(s) tested. The specific description is noted in each of the individual sections of the test report supporting this certificate of test. Northwest EMC Revision History Revision 05/05/03 Revision Number Description Date Page Number 00 Accreditations and Authorizations FCC Accredited by NVLAP for performance of FCC radio, digital, and ISM device testing. Our Open Area Test Sites, certification chambers, and conducted measurement facilities have been fully described in reports filed with the FCC and accepted by the FCC in letters maintained in our files. Northwest EMC has been accredited by ANSI to ISO / IEC Guide 65 as a product certifier. We have been designated by the FCC as a Telecommunications Certification Body (TCB). This allows Northwest EMC to certify transmitters to FCC specifications in accordance with 47 CFR 2.960 and 2.962. NVLAP Northwest EMC, Inc. is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP) for satisfactory compliance with the requirements of ISO/IEC 17025 for Testing Laboratories. NVLAP is administered by the National Institute of Standards and Technology (NIST), an agency of the U.S. Commerce Department. The NVLAP accreditation encompasses Electromagnetic Compatibility Testing in accordance with the European Union EMC Directive 2004/108/EC, and ANSI C63.4. Additionally, Northwest EMC is accredited by NVLAP to perform radio testing in accordance with the European Union R&TTE Directive 1999/5/EEC, the requirements of FCC, and the RSS radio standards for Industry Canada. Industry Canada Accredited by NVLAP for performance of Industry Canada RSS and ICES testing. Our Open Area Test Sites and certification chambers comply with RSS-Gen, Issue 2 and have been filed with Industry Canada and accepted. Northwest EMC has been accredited by ANSI to ISO / IEC Guide 65 as a product certifier. We have been designated by NIST and recognized by Industry Canada as a Certification Body (CB) per the APEC Mutual Recognition Arrangement (MRA). This allows Northwest EMC to certify transmitters to Industry Canada technical requirements. (Site Filing Numbers - Hillsboro: 2834D-1, 2834D-2, Sultan: 2834C-1, Irvine: 2834B-1, 2834B-2, Brooklyn Park: 2834E-1) CAB Designated by NIST and validated by the European Commission as a Conformity Assessment Body (CAB) to conduct tests and approve products to the EMC directive and transmitters to the R&TTE directive, as described in the U.S. - EU Mutual Recognition Agreement. Australia/New Zealand The National Association of Testing Authorities (NATA), Australia has been appointed by the ACA as an accreditation body to accredit test laboratories and competent bodies for EMC standards. Accredited test reports or assessments by competent bodies must carry the NATA logo. Test reports made by an overseas laboratory that has been accredited for the relevant standards by an overseas accreditation body that has a Mutual Recognition Agreement (MRA) with NATA are also accepted as technical grounds for product conformity. The report should be endorsed with the respective logo of the accreditation body (NVLAP). Accreditations and Authorizations VCCI Accepted as an Associate Member to the VCCI, Acceptance No. 564. Conducted and radiated measurement facilities have been registered in accordance with Regulations for Voluntary Control Measures, Article 8. (Registration Numbers. - Hillsboro: C-1071, R-1025, G-84, C-2687, T- 1658, and R-2318, Irvine: R-1943, G-85, C-2766, and T-1659, Sultan: R-871, G-83, C-1784, and T-1511, Brooklyn Park: R-3125, G-86, G-141, C-3464, and T-1634). BSMI Northwest EMC has been designated by NIST and validated by C-Taipei (BSMI) as a CAB to conduct tests as described in the APEC Mutual Recognition Agreement (US0017). GOST Northwest EMC, Inc. has been assessed and accredited by the Russian Certification bodies Certinform VNIINMASH, CERTINFO, SAMTES, and Federal CHEC, to perform EMC and Hygienic testing for Information Technology Products. As a result of their laboratory assessment, they will accept test results from Northwest EMC, Inc. for product certification KCC Northwest EMC, Inc is a CAB designated by MRA partners and recognized by Korea. (Assigned Lab Numbers: Hillsboro: US0017, Irvine: US0158, Sultan: US0157, Brooklyn Park: US0175) VIETNAM Vietnam MIC has approved Northwest EMC as an accredited test lab. Per Decision No. 194/QD-QLCL (dated December 15, 2009), Northwest EMC test reports can be used for Vietnam approval submissions. SCOPE For details on the Scopes of our Accreditations, please visit: http://www.nwemc.com/accreditations/ Northwest EMC Locations Oregon Labs EV01-EV12 22975 NW Evergreen Pkwy Suite 400 Hillsboro, OR 97124 (503) 844-4066 California Labs OC01-OC13 41 Tesla Irvine, CA 92618 (949) 861-8918 Minnesota Labs MN01-MN08 9349 W Broadway Ave. Brooklyn Park, MN 55445 (763) 425-2281 Washington Labs SU01-SU07 14128 339 th Ave. SE Sultan, WA 98294 (360) 793-8675 New York Labs WA01-WA04 4939 Jordan Rd. Elbridge, NY 13060 (315) 685-0796 Northwest …

Text truncated - open the document above for the full version.

Test Report

iTextAlert LLC ITA-1 Report #: 7LAY0059.1 Report Prepared By Northwest EMC Inc. NORTHWEST EMC – (888) 364-2378 – www.nwemc.com California – Minnesota – Oregon – New York – Washington 22975 NW Evergreen Parkway Suite 400 Hillsboro, Oregon 97124 Certificate of Test Last Date of Test: December 27, 2011 iTextAlert LLC Model: ITA-1 Emissions Test Description Specification Test Method Pass/Fail Occupied Bandwidth FCC 15.247:2011 ACSI C63.10:2009 Pass Output Power FCC 15.247:2011 ACSI C63.10:2009 Pass Band Edge Compliance FCC 15.247:2011 ACSI C63.10:2009 Pass Power Spectral Density FCC 15.247:2011 ACSI C63.10:2009 Pass Spurious Radiated Emissions FCC 15.247:2011 ACSI C63.10:2009 Pass Spurious Radiated Emissions FCC 15.209:2011 ACSI C63.10:2009 Pass AC Powerline Conducted Emissions FCC 15.207:2011 ACSI C63.10:2009 Pass Deviations From Test Standards None Approved By: Tim O'Shea, Operations Manager NVLAP Lab Code: 200676-0 Test Facility The measurement facility used to collect the data is located at: Northwest EMC, Inc. 41 Tesla Ave. Irvine, CA 92618 Phone: (503) 844-4066 Fax: 844-3826 This site has been fully described in a report filed with and accepted by the FCC (Federal Communications Commission) and Industry Canada (Site filing #2834B-1). This report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government of the United States of America. Product compliance is the responsibility of the client, therefore the tests and equipment modes of operation represented in this report were agreed upon by the client, prior to testing. This Report may only be duplicated in its entirety. The results of this test pertain only to the sample(s) tested. The specific description is noted in each of the individual sections of the test report supporting this certificate of test. Revision History Revision 09/01/11 Revision Number Description Date Page Number 00 None Accreditations and Authorizations Revision 09/01/11 FCC Accredited by NVLAP for performance of FCC radio, digital, and ISM device testing. Our Open Area Test Sites, certification chambers, and conducted measurement facilities have been fully described in reports filed with the FCC and accepted by the FCC in letters maintained in our files. Northwest EMC has been accredited by ANSI to ISO / IEC Guide 65 as a product certifier. We have been designated by the FCC as a Telecommunications Certification Body (TCB). This allows Northwest EMC to certify transmitters to FCC specifications in accordance with 47 CFR 2.960 and 2.962. NVLAP Northwest EMC, Inc. is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP) for satisfactory compliance with the requirements of ISO/IEC 17025 for Testing Laboratories. NVLAP is administered by the National Institute of Standards and Technology (NIST), an agency of the U.S. Commerce Department. The NVLAP accreditation encompasses Electromagnetic Compatibility Testing in accordance with the European Union EMC Directive 2004/108/EC, and ANSI C63.4. Additionally, Northwest EMC is accredited by NVLAP to perform radio testing in accordance with the European Union R&TTE Directive 1999/5/EEC, the requirements of FCC, and the RSS radio standards for Industry Canada. Industry Canada Accredited by NVLAP for performance of Industry Canada RSS and ICES testing. Our Open Area Test Sites and certification chambers comply with RSS-Gen, Issue 2 and have been filed with Industry Canada and accepted. Northwest EMC has been accredited by ANSI to ISO / IEC Guide 65 as a product certifier. We have been designated by NIST and recognized by Industry Canada as a Certification Body (CB) per the APEC Mutual Recognition Arrangement (MRA). This allows Northwest EMC to certify transmitters to Industry Canada technical requirements. (Site Filing Numbers - Hillsboro: 2834D-1, 2834D-2, Sultan: 2834C-1, Irvine: 2834B-1, 2834B-2, Brooklyn Park: 2834E-1) CAB Designated by NIST and validated by the European Commission as a Conformity Assessment Body (CAB) to conduct tests and approve products to the EMC directive and transmitters to the R&TTE directive, as described in the U.S. - EU Mutual Recognition Agreement. Australia/New Zealand The National Association of Testing Authorities (NATA), Australia has been appointed by the ACA as an accreditation body to accredit test laboratories and competent bodies for EMC standards. Accredited test reports or assessments by competent bodies must carry the NATA logo. Test reports made by an overseas laboratory that has been accredited for the relevant standards by an overseas accreditation body that has a Mutual Recognition Agreement (MRA) with NATA are also accepted as technical grounds for product conformity. The report should be endorsed with the respective logo of the accreditation body (NVLAP). Accreditations and Authorizations Revision 09/01/11 VCCI Accepted as an Associate Member to the VCCI, Acceptance No. 564. Conducted and radiated measurement facilities have been registered in accordance with Regulations for Voluntary Control Measures, Article 8. (Registration Numbers. - Hillsboro: C-1071, R- 1025, G-84, C-2687, T-1658, and R-2318, Irvine: R-1943, G-85, C-2766, and T-1659, Sultan: R-871, G-83, C-3265, and T-1511, Brooklyn Park: R-3125, G-86, G-141, C-3464, and T-1634). BSMI Northwest EMC has been designated by NIST and validated by C-Taipei (BSMI) as a CAB to conduct tests as described in the APEC Mutual Recognition Agreement (US0017). GOST Northwest EMC, Inc. has been assessed and accredited by the Russian Certification bodies Certinform VNIINMASH, CERTINFO, SAMTES, and Federal CHEC, to perform EMC and Hygienic testing for Information Technology Products. As a result of their laboratory assessment, they will accept test results from Northwest EMC, Inc. for product certification KCC Northwest EMC, Inc is a CAB designated by MRA partners and recognized by Korea. (Assigned Lab Numbers: Hillsboro: US0017, Irvine: US0158…

Text truncated - open the document above for the full version.

Test Report

iTextAlert LLC ITA-1 Report #: 7LAY0059 Report Prepared By Northwest EMC Inc. NORTHWEST EMC – (888) 364-2378 – www.nwemc.com California – Minnesota – Oregon – New York – Washington 22975 NW Evergreen Parkway Suite 400 Hillsboro, Oregon 97124 Certificate of Test Last Date of Test: December 28, 2011 iTextAlert LLC Model: ITA-1 Emissions Test Description Specification Test Method Pass/Fail Occupied Bandwidth FCC 15.247:2011 ACSI C63.10:2009 Pass Output Power FCC 15.247:2011 ACSI C63.10:2009 Pass Band Edge Compliance FCC 15.247:2011 ACSI C63.10:2009 Pass Power Spectral Density FCC 15.247:2011 ACSI C63.10:2009 Pass Spurious Radiated Emissions FCC 15.247:2011 ACSI C63.10:2009 Pass Spurious Radiated Emissions FCC 15.209:2011 ACSI C63.10:2009 Pass AC Powerline Conducted Emissions FCC 15.207:2011 ACSI C63.10:2009 Pass Deviations From Test Standards None Approved By: Tim O'Shea, Operations Manager NVLAP Lab Code: 200676-0 Test Facility The measurement facility used to collect the data is located at: Northwest EMC, Inc. 41 Tesla Ave. Irvine, CA 92618 Phone: (503) 844-4066 Fax: 844-3826 This site has been fully described in a report filed with and accepted by the FCC (Federal Communications Commission) and Industry Canada (Site filing #2834B-1). This report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government of the United States of America. Product compliance is the responsibility of the client, therefore the tests and equipment modes of operation represented in this report were agreed upon by the client, prior to testing. This Report may only be duplicated in its entirety. The results of this test pertain only to the sample(s) tested. The specific description is noted in each of the individual sections of the test report supporting this certificate of test. Revision History Revision 09/01/11 Revision Number Description Date Page Number 00 None Accreditations and Authorizations Revision 09/01/11 FCC Accredited by NVLAP for performance of FCC radio, digital, and ISM device testing. Our Open Area Test Sites, certification chambers, and conducted measurement facilities have been fully described in reports filed with the FCC and accepted by the FCC in letters maintained in our files. Northwest EMC has been accredited by ANSI to ISO / IEC Guide 65 as a product certifier. We have been designated by the FCC as a Telecommunications Certification Body (TCB). This allows Northwest EMC to certify transmitters to FCC specifications in accordance with 47 CFR 2.960 and 2.962. NVLAP Northwest EMC, Inc. is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP) for satisfactory compliance with the requirements of ISO/IEC 17025 for Testing Laboratories. NVLAP is administered by the National Institute of Standards and Technology (NIST), an agency of the U.S. Commerce Department. The NVLAP accreditation encompasses Electromagnetic Compatibility Testing in accordance with the European Union EMC Directive 2004/108/EC, and ANSI C63.4. Additionally, Northwest EMC is accredited by NVLAP to perform radio testing in accordance with the European Union R&TTE Directive 1999/5/EEC, the requirements of FCC, and the RSS radio standards for Industry Canada. Industry Canada Accredited by NVLAP for performance of Industry Canada RSS and ICES testing. Our Open Area Test Sites and certification chambers comply with RSS-Gen, Issue 2 and have been filed with Industry Canada and accepted. Northwest EMC has been accredited by ANSI to ISO / IEC Guide 65 as a product certifier. We have been designated by NIST and recognized by Industry Canada as a Certification Body (CB) per the APEC Mutual Recognition Arrangement (MRA). This allows Northwest EMC to certify transmitters to Industry Canada technical requirements. (Site Filing Numbers - Hillsboro: 2834D-1, 2834D-2, Sultan: 2834C-1, Irvine: 2834B-1, 2834B-2, Brooklyn Park: 2834E-1) CAB Designated by NIST and validated by the European Commission as a Conformity Assessment Body (CAB) to conduct tests and approve products to the EMC directive and transmitters to the R&TTE directive, as described in the U.S. - EU Mutual Recognition Agreement. Australia/New Zealand The National Association of Testing Authorities (NATA), Australia has been appointed by the ACA as an accreditation body to accredit test laboratories and competent bodies for EMC standards. Accredited test reports or assessments by competent bodies must carry the NATA logo. Test reports made by an overseas laboratory that has been accredited for the relevant standards by an overseas accreditation body that has a Mutual Recognition Agreement (MRA) with NATA are also accepted as technical grounds for product conformity. The report should be endorsed with the respective logo of the accreditation body (NVLAP). Accreditations and Authorizations Revision 09/01/11 VCCI Accepted as an Associate Member to the VCCI, Acceptance No. 564. Conducted and radiated measurement facilities have been registered in accordance with Regulations for Voluntary Control Measures, Article 8. (Registration Numbers. - Hillsboro: C-1071, R- 1025, G-84, C-2687, T-1658, and R-2318, Irvine: R-1943, G-85, C-2766, and T-1659, Sultan: R-871, G-83, C-3265, and T-1511, Brooklyn Park: R-3125, G-86, G-141, C-3464, and T-1634). BSMI Northwest EMC has been designated by NIST and validated by C-Taipei (BSMI) as a CAB to conduct tests as described in the APEC Mutual Recognition Agreement (US0017). GOST Northwest EMC, Inc. has been assessed and accredited by the Russian Certification bodies Certinform VNIINMASH, CERTINFO, SAMTES, and Federal CHEC, to perform EMC and Hygienic testing for Information Technology Products. As a result of their laboratory assessment, they will accept test results from Northwest EMC, Inc. for product certification KCC Northwest EMC, Inc is a CAB designated by MRA partners and recognized by Korea. (Assigned Lab Numbers: Hillsboro: US0017, Irvine: US0158, …

Text truncated - open the document above for the full version.

Test Setup Photos

NORTHWEST EMC transmit2.JPG transmit1.JPG Occupied Bandwidth XMit 2011.10.26 photo transmit1.JPG transmit2.JPG OUTPUT POWER PSA-ESCI 2011.10.17 NORTHWEST EMC transmit2.JPG transmit1.JPG Band Edge Compliance XMit 2011.10.26 NORTHWEST EMC POWER SPECTRAL DENSITY XMit 2010.01.14 photo SRB2.JPG SRB3.JPG SPURIOUS RADIATED EMISSIONS PSA-ESCI 2011.10.17 photo SRB4.JPG SRB5.JPG SPURIOUS RADIATED EMISSIONS PSA-ESCI 2011.10.17 photo IMG_0186.JPG IMG_0183.JPG AC POWERLINE CONDUCTED EMISSIONS PSA-ESCI 2011.10.17 photo IMG_0185.JPG AC POWERLINE CONDUCTED EMISSIONS PSA-ESCI 2011.10.17

Test Setup Photos

NORTHWEST EMC SRB1.JPG SRB5.JPG Occupied Bandwidth XMit 2011.10.26 photo SRB5.JPG SRB3.JPG OUTPUT POWER PSA-ESCI 2011.10.17 photo SRB4.JPG OUTPUT POWER PSA-ESCI 2011.10.17 NORTHWEST EMC SRB5.JPG SRB2.JPG Band Edge Compliance XMit 2011.10.26 NORTHWEST EMC POWER SPECTRAL DENSITY XMit 2010.01.14 photo SRB2.JPG SRB3.JPG SPURIOUS RADIATED EMISSIONS PSA-ESCI 2011.10.17 photo SRB4.JPG SRB5.JPG SPURIOUS RADIATED EMISSIONS PSA-ESCI 2011.10.17 photo IMG_0183.JPG IMG_0185.JPG AC POWERLINE CONDUCTED EMISSIONS PSA-ESCI 2011.10.17 photo IMG_0186.JPG AC POWERLINE CONDUCTED EMISSIONS PSA-ESCI 2011.…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Scott D Rubins(President & CEO)
[email protected]309-944-2103Fax: 309-944-4406

Test Firm

Northwest EMC, Inc.Greg Kiemel
[email protected]503-844-4066Fax: 503-844-3826

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz1.60 mW
Confidentiality
Long Term
Grant Notes
Output power listed is EIRP. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter within a host device, except as described in this filing, or in accordance with FCC multi-transmitter product procedures.

Other Applications from iTextAlert LLC

ITA-1 Sensor AA - FCC ID Z3GITA1SENAA - iTextAlert LLC
Z3GITA1SENAA

ITA-1 Sensor AA

Nov 01, 2011

Equipment Class

DTS - Digital Transmission System
ITA-1 Sensor AAA - FCC ID Z3GITA1SENAAA - iTextAlert LLC
Z3GITA1SENAAA

ITA-1 Sensor AAA

Nov 01, 2011

Equipment Class

DTS - Digital Transmission System