FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zoll Medical Corp/
  3. ZKP-ZOLLALS0001

ZKP-ZOLLALS0001Embedded communications module - 802.11 a/b/g/n/ac and Bluetooth

Zoll Medical Corp

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Apr 15, 2024
Application Purpose
Original Equipment
Date of Application
Apr 15, 2024
Equipment Note
Embedded communications module - 802.11 a/b/g/n/ac and Bluetooth
Frequency Range
5745.00000000 - 5825.00000000
Company
Zoll Medical Corp
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

RF Exposure Info

Phone: +1 (949) 393-1123 Web: www.vista-compliance.com Email: [email protected] RF Exposure Report Test Report Number STA-22121361-LCG-FCC-IC-MPE FCC ID IC ID ZKP-ZOLLALS0001 9702A-ZOLLALS0001 Applicant ZOLL Medical Corporation Applicant Address 269 Mill Road, Chelmsford, MA 01824-4105 Product Name Zenix Monitor/Defibrillator Model Number Zenix Date of Receipt 08/10/2023 Date of Test 08/24/2023 – 08/29/2023 Report Issue Date 03/27/2024 Test Standards 47 CFR §1.1307(b), 47 CFR §1.1310 RSS-102 Issue 6 Dec 2023 Test Result PASS Issued by: Vista Compliance Laboratories 1261 Puerta Del Sol, San Clemente, CA 92673 USA www.vista-compliance.com Devin Tai (Test Engineer) David Zhang (Technical Manager) This report is for the exclusive use of the applicant. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. Note that the results contained in this report pertain only to the test samples identified herein, and the results relate only to the items tested and the results that were obtained in the period between the date of initial receipt of samples and the date of issue of the report. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested and the results thereof based upon the information provided to us. The applicant has 60 days from date of issuance of this report to notify us of any material error or omission. Failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report must not be used by the client to claim product certification, approval, or endorsement by any government agencies. This report is not to be reproduced by any means except in full and in any case not without the written approval of Vista Laboratories. Report# STA-22121361-LCG-FCC-IC-MPE Page 2 of 10 REVISION HISTORY Report Number Version Description Issued Date STA-22121361-LCG-FCC-IC-MPE 01 Initial report 03/27/2024 Report# STA-22121361-LCG-FCC-IC-MPE Page 3 of 10 TABLE OF CONTENTS 1 GENERAL INFORMATION ..................................................................................................................................... 4 1.1 Applicant ........................................................................................................................................................ 4 1.2 Product information .................................................................................................................................... 4 1.3 Test standard and method......................................................................................................................... 5 2 TEST SITE INFORMATION ..................................................................................................................................... 5 3 FCC RF EXPOSURE EVALUATION........................................................................................................................ 6 3.1 Limits for Maximum Permissible Exposure (MPE) ................................................................................ 6 3.2 MPE Calculation Formula ........................................................................................................................... 6 3.3 Classification ................................................................................................................................................. 6 3.4 Antenna Gain ................................................................................................................................................ 6 3.5 FCC RF Exposure Evaluation Results ........................................................................................................ 7 4 ISED RF EXPOSURE EVALUATION ...................................................................................................................... 8 4.1 Limits for Maximum Permissible Exposure (MPE) ................................................................................ 8 4.2 MPE Calculation Formula ........................................................................................................................... 9 4.3 Classification ................................................................................................................................................. 9 4.4 Antenna Gain ................................................................................................................................................ 9 4.5 ISED RF Exposure Evaluation Results ..................................................................................................... 10 Report# STA-22121361-LCG-FCC-IC-MPE Page 4 of 10 1 General Information 1.1 Applicant Applicant ZOLL Medical Corporation Applicant Address 269 Mill Road, Chelmsford, MA 01824-4105 Manufacturer ZOLL Medical Corporation Manufacturer Address 269 Mill Road, Chelmsford, MA 01824-4105 1.2 Product information Product Name Zenix Monitor/Defibrillator Model Number Zenix Family Models N/A Serial Number ST22E00204 Frequency Band BT BDR/EDR: 2402-2480MHz BT BLE: 2402-2480MHz WLAN: 2.4GHz/5GHz 11a/b/g/n/ac Type of modulation BT BDR/EDR: GFSK, π/4DQPSK, 8DPSK BLE: GFSK 802.11b: DSSS (CCK, DQPSK, DBPSK) 802.11g: OFDM-CCK (BPSK, QPSK, 16QAM, 64QAM) 802.11a/n/ac: OFDM (BPSK, QPSK, 16QAM, 64QAM, 256QAM) Equipment Class DSS, DTS, U-NII Antenna Information 2.4/…

Text truncated - open the document above for the full version.

Test Report

5000 -0054-FM REV T APPROVED VENDOR LIST VENDOR NAME VENDOR PART NUMBER ROHS COMPLIANT 1 st MOLEX1461530100 YES 2 nd 3 rd 4 TH 5 TH SHELF NO YES  TEMP NO YES  MSL Rating NO YES  PARAMETER NO YES  RoHS COMPLIANT NO YES  PARTIAL  N/A  NOTES Revision B adds material information on the coax cable used on this assembly. There is no electrical or mechanical difference between the Rev B and Rev A release. This a documentation change only. ORIGINATOR R. Salcedo DESCRIPTION ANTENNA, 2.4/5GHz, 100mm COAX w/ MHF CONN ZOLL Medical Corporation 269 & 271 Mill Road Chelmsford, MA 01824-4105 DATE 2/7/2022 SHEET 1 of 50 DOCUMENT NO. 0301-000128-PS REV. B This document was generated on 12/27/2021 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION Part Number: 1461530100 Status: Active Overview:Internet of Things (IoT) Antennas: Wi-Fi, Bluetooth, Zigbee Description:Wi-Fi 6E Flex Cabled Balanced Antenna, 9.00mm Width, 100.00mm Cable Length, Compatible with U.FL / I-PEX MHF Connectors Documents: 3D ModelApplication Specification AS-146153-100-001 (PDF) Drawing (PDF)Packaging Specification 1461530100-000 (PDF) 3D Model (PDF)Datasheet (PDF) Product Specification PS-146153-100-001 (PDF)RoHS Certificate of Compliance (PDF) General Product FamilyAntennas Series146153 Component TypeFlexible Antenna with Cable FunctionSignal Mates WithMolex Receptacle 734120110 and other alternatives OverviewInternet of Things (IoT) Antennas: Wi-Fi, Bluetooth, Zigbee Product Name2.4/5GHz Balanced Flex Antenna ProtocolBLE, BT, Thread, Wi-Fi, Wireless Hart, Zigbee TypeWi-Fi Antenna UPC889056310017 Physical Cable Length100.00mm Length34.90mm Mounting StyleAdhesive Net Weight0.574/g Packaging TypePET Film PolarizationLinear Radiation PatternOmnidirectional Thickness0.10mm Width9.00mm Electrical Band#1 F_End (MHz)2483.5 Band#1 F_Start (MHz)2400 Band#2 F_End (MHz)5930 Band#2 F_Start (MHz)4900 Electrical ConnectivityCable Peak Gain (dBi)3.0 @ 2.4 GHz, 4.0 @ 5 GHz Return Loss - S11 (dB)< -10 Total Efficiency>75% @ 2.4 GHz, >75% @ 5 GHz Material Info Reference - Drawing Numbers Application SpecificationAS-146153-100-001 Packaging Specification1461530100-000 Product SpecificationPS-146153-100-001 Sales DrawingSD-146153-050-001 Series image - Reference only EU ELV Not Relevant EU RoHSChina RoHS Compliant REACH SVHC Not Contained Per - D(2021)4569-DC (8 July 2021) Halogen-Free Status Low-Halogen For more information, please visit Contact US China ROHSGreen Image ELVNot Relevant RoHS PhthalatesNot Contained Search Parts in this Series 146153 Series This document was generated on 12/27/2021 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION Dual-band transmission-balanced antennas combine ground-plane independence with high-radiation efficiency for better connectivity and faster wireless device processing Telecommunications/Networking Wi-Fi devices Wireless LAN (WLAN) IEEE 802.11b/g/n devices Industrial applications Machine to machine (M2M) communication Smartmeters 2.4GHz § ZigBee IEEE 802.15.4 devices 2.4 GHz and 5 GHz Industrial, Scientific and Medical (ISM) band systems and wireless devices Consumer Electronics (CE) Applications Cameras Mobile gaming devices Personal navigation devices Wireless internet TV and audio devices Medical Telemedicine and telehealth device Automotive applications ‡ Bluetooth devices Infotainment devices Mobile hotspots Applications Product Features Features and Benefits Telehealth devices Smartmeters Infotainment devices Wireless Internet TV Balanced antenna with ground-plane independent designReduces engineering resources and costs needed to mitigate PCB ground-induced radiation High radiation efficiency with 34.90 by 9.00 mm strip antenna Offers total efficiency values of 75% minimum in the 2.4GHz band and 70% minimum in the 5GHz band Poly-flexible, double-sided adhesive tape on antenna Enables easy peel-and-stick mounting anywhere within the device casing Coaxial cable to center-fed antenna attachment with over 18.0N of pull force Ensures robust antenna reliability and connectivity to radio device Wide selection of micro-coaxial cable lengths from 50 to 300mm Extends connectivity for maximum design flexibility 2.4/5GHz Wi-Fi † Flexible Antenna with Balanced Transmission 146153 RoHS-compliant, Halogen-free Series 146153 † Wi-Fi-ready dual-band antennas † Wi-Fi is a registered trademarks of the Wi-Fi Alliance. ‡ Bluetooth is a registered trademark of Bluetooth SIG. § ZIGBEE is a registered trademark of trademark of ZigBee Alliance. Topside of the poly- flexible antenna Micro-coaxial cable This dipole-style antenna offers balanced transmission throughout the entire connection regardless of cable length Upon removal of its tape liner, the antenna can be applied anywhere within the device chassis. The UFL-type connector at the extreme end of the antenna is secured to the application’s device radio (not shown in the illustration) Double -sided adhesive on the reverse Top and underside views of the UFL-type connector ©2015 Molex www.molex.com/link/standard_antennas.html Specifications Reference Information Packaging: PE film Mates With: Surface-mount, micro-coaxial jack (Part Number: 73412-0110) Designed In: mm RoHS: Yes Halogen Free: Yes Glow Wire Compliant: No Electrical specifications (2.4 GHz) include: f_start (MHz): 2400 f_end (MHz): 2483.5 Return Loss S11 (dB): Refer to table Total Eff. (dB): Refer to table Peak Gain (dBi): Refer to table Polarization: Linear Input Impedance (Ohms): 50 Electrical specifications (5 GHz) include: f_start (MHz): 5150 f_end (MHz): 5850 Return Loss S11 (dB): Refer to table Total Eff. (dB): Refer to table Peak Gain (dBi): Refer to table Polarization: Linear Input Impedance (Ohms): 50 Mechanical Pull Force: > 18.0N Physical Thickness: 0.10mm Operating Temperature: -30 to +85°C Ordering Information Unique And Useful Differentation vs. Similar Molex Product Order No. Flexi-Antenna Dimensions Miniature Coaxial Cable Lengths (mm) Frequency Range (GHz)Return Loss S11 (db)…

Text truncated - open the document above for the full version.

Test Report

Phone: +1 (949) 393-1123 Web: www.vista-compliance.com Email: [email protected] RF Test Report Test Report Number STA-22121361-LCG-FCC-IC-RF-NII FCC ID IC ID Applicant ZKP-ZOLLALS0001 9702A-ZOLLALS0001 ZOLL Medical Corporation Applicant Address 269 Mill Road, Chelmsford, MA 01824-4105 Product Name Zenix Monitor/Defibrillator Model (s) Zenix Date of Receipt 08/10/2023 Date of Test 08/21/2023 – 08/24/2023 Report Issue Date 03/27/2024 Test Standards 47 CFR Part 15.247 Test Result RSS-247 Issue 3, Aug 2023 PASS Issued by: Vista Compliance Laboratories 1261 Puerta Del Sol, San Clemente, CA 92673 USA www.vista-compliance.com Devin Tai (Test Engineer) David Zhang (Technical Manager) This report is for the exclusive use of the applicant. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. Note that the results contained in this report pertain only to the test samples identified herein, and the results relate only to the items tested and the results that were obtained in the period between the date of initial receipt of samples and the date of issue of the report. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested and the results thereof based upon the information provided to us. The applicant has 60 days from date of issuance of this report to notify us of any material error or omission. Failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report must not be used by the client to claim product certification, approval, or endorsement by any government agencies. This report is not to be reproduced by any means except in full and in any case not without the written approval of Vista Laboratories. Report # STA-22121361-LCG-FCC-IC-RF-NII Page 2 of 50 REVISION HISTORY Report Number Version Description Issued Date STA-22121361-LCG-FCC-IC-RF-NII 01 Initial report 03/27/2024 Report # STA-22121361-LCG-FCC-IC-RF-NII Page 3 of 50 TABLE OF CONTENTS 1 TEST SUMMARY ...................................................................................................................................................... 4 2 GENERAL INFORMATION ..................................................................................................................................... 5 2.1 Applicant ................................................................................................................................................. 5 2.2 Product information .............................................................................................................................. 5 2.3 Test standard and method ................................................................................................................... 5 3 TEST SITE INFORMATION ..................................................................................................................................... 6 4 MODIFICATION OF EUT / DEVIATIONS FROM STANDARDS ....................................................................... 6 5 TEST CONFIGURATION AND OPERATION ....................................................................................................... 6 5.1 EUT Test Configuration ......................................................................................................................... 6 5.2 Supporting Equipment .......................................................................................................................... 6 6 UNCERTAINTY OF MEASUREMENT ................................................................................................................... 7 7 TEST RESULTS .......................................................................................................................................................... 8 7.1 Radiated Spurious Emission................................................................................................................. 8 8 EUT AND TEST SETUP PHOTOS ......................................................................................................................... 49 9 TEST INSTRUMENT LIST ..................................................................................................................................... 50 Report # STA-22121361-LCG-FCC-IC-RF-NII Page 4 of 50 1 Test Summary Test Item Test Requirement Test Method Result Antenna Requirement 47 CFR Part 15.203 N/A N/A* AC Power Line Conducted Emissions 47 CFR Part 15.207 RSS-Gen Issue 5, Feb 2021 ANSI C63.10 (2013) RSS-Gen Issue 5, Feb 2021 N/A* 26 dB Bandwidth 47 CFR Part 15.247 RSS-247 Issue 3, Aug 2023 ANSI C63.10 (2013) N/A* Occupied Bandwidth RSS-247 Issue 3, Aug 2023 RSS-247 Issue 3, Aug 2023 N/A* Maximum Conducted Output Power 47 CFR Part 15.247 RSS-247 Issue 3, Aug 2023 ANSI C63.10 (2013) N/A* Power Spectral Density 47 CFR Part 15.247 RSS-247 Issue 3, Aug 2023 ANSI C63.10 (2013) N/A* Radiated Band-Edge into Restricted Frequency Bands 47 CFR Part 15.247 RSS-247 Issue 3, Aug 2023 ANSI C63.10 (2013) N/A* Radiated Spurious Emission 47 CFR Part 15.247 RSS-247 Issue 3, Aug 2023 ANSI C63.10 (2013) Pass Note: * The EUT is a host product with FCC/ISED certified BT and WLAN single module integrated (Module model: SX- SDMAC). For more test details, please see FCC ID: N6C-SDMAC and ISED ID: 4908A-SDMAC. The current report is an additio…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Carl Mamuszka(Principal Compliance Engineer)
[email protected]978 421-9330Fax: 978 421-0049

Test Firm

Vista Laboratories, Inc.David Zhang
[email protected]9494647589

Technical Specifications

#Rule PartsFrequency RangePower Output
415E5.75 GHz - 5.83 GHz13.90 mW
Confidentiality
Long Term
Grant Notes
Power output listed is the maximum conducted power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multitransmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The 5GHz WLAN of this device supports 20MHz, 40MHz and 80MHz bandwidth. This device complies with the Dynamic Frequency Selection (DFS) requirements of KDB 905462 D03 as a Client only without Radar Detection.

Other Applications from Zoll Medical Corp

Z-RS-DC002 - FCC ID ZKP-RDC002 - Zoll Medical Corp
ZKP-RDC002

Z-RS-DC002

Aug 18, 2013

Equipment Class

DTS - Digital Transmission System
X Series - FCC ID ZKP-XSCP0001 - Zoll Medical Corp
ZKP-XSCP0001

X Series

Jan 19, 2012

Equipment Class

NII - Unlicensed National Information Infrastructure TX
ZOLL E Series Data Comm Card - FCC ID ZKP-DMC001 - Zoll Medical Corp
ZKP-DMC001

ZOLL E Series Data Comm Card

Nov 27, 2011

Equipment Class

DTS - Digital Transmission System