Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FibocomWirelessInc. To:FederalCommunicationsCommissionDate:2026-01-21 7435OaklandMillsRoad Columbia,MD21046 USA Attestation Section2.911(d)(5)(i)andSection2.911(d)(5)(ii) (KDB986446D01CoveredEquipment) Section2.911(d)(5)(i) FibocomWirelessInc.certifiesthattheequipmentforwhichauthorizationissoughtis notโcoveredโequipmentprohibitedfromreceivinganequipmentauthorization pursuanttosection2.903oftheFCCrules. Section2.911(d)(5)(ii) FibocomWirelessInc.certifiesthat,asofthedateofthefilingoftheapplication,the applicantisnotidentifiedontheCoveredList(asaspecificallynamedentityoranyof itssubsidiariesoraffiliates)asanentityproducingโcoveredโequipment. TypeofEquipmentsubjecttoFCCCertification:LTEModule FCCID:ZMOLE271GL Ifyouhaveanyquestions,pleasefeelfreetocontactme ContactPerson:PatrickMa PositionintheCompany:CertificationDirector DateofSignature:2026-01-21 ___________________________ Signatory (signatureoftheapplicant)
Fibocom Wireless Inc. 1101,Tower A, Building 6, Shenzhen International, Innovation Valley, Dashi 1st Rd, Nanshan, ShenZhen, China Te l : +8675526733555 ; Fax: +86-755-26520841 F ederal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Certification designating a U.S. agent for service of process pursuant to Part 2.911(d)(7) T o whom it may concern, [F ibocom Wireless Inc. Grantee Code ZMO] (โthe applicantโ) certifies that, as of the date of the filing of application, [Fibocom Wireless USA] (โthe agentโ) is designated as the U.S. agent for the purpose of accepting service of process on behalf of the applicant. The information of agent are: U.S. Agent: Fibocom Wireless USA FCC Registration Number (FRN): 0033437914 Physical U.S. address: 5909 Peachtree Dunwoody Rd Ste 910 Atlanta, GA 30328 United Statess Contact: Amy DeBuysere Phone: +01 865-888-0420 Email: [email protected] T he applicant accepts to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. T he agent accepts the designation by (the applicant) as the U.S. agent to accept service of process includes, but is not limited to, delivery of any correspondence, notices, orders, decisions, and requirements of administrative, legal, or judicial process related to Commission proceedings. Sig ned by the Applicant Signed by the Agent Name: Patrick Ma Name: Amy DeBuysere Email: [email protected] Email: [email protected] Date: May 28, 2025 Date: May 28, 2025
FibocomWirelessInc. Date:2026-01-21 To:FederalCommunicationsCommission, Authorization&EvaluationDivision, 7435OaklandMillsRoad, Columbia,MD21046 ToWhomItMayConcern: TheFibocomWirelessInc.,theundersigned,herebyauthorizesMiss.Wendy ZhanfromShenzhenMorlabCommunicationsTechnologyCo.,Ltd.,toact onthebehalfoftheFibocomWirelessInc.solelyinmattersrelatingtothe applicationforanFCCequipmentauthorizationforFCCID:ZMOLE271GL includingthesigningofdocumentsinconnectionwiththisApplication.Necessary actscarriedoutShenzhenMorlabCommunicationsTechnologyCo.,Ltd.on ourbehalfoftheFibocomWirelessInc.inconnectionwiththeApplicationshall havethesameeffectasactsoftheFibocomWirelessInc..FibocomWirelessInc. alsoherebycertifythatnopartytothisapplicationissubjecttoadenialofbenefits, includingFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseActof 1988,21U.S.C.862. Thankyouforyourattentiontothismatter. YoursSincerely, Signatory: Contactname:PatrickMa Title:CertificationDirector Tel:+8675526733555 Email:[email protected] Companyname:FibocomWirelessInc.
FibocomWirelessInc. Date:2026-01-21 To:FederalCommunicationsCommission, Authorization&EvaluationDivision, 7435OaklandMillsRoad, Columbia,MD21046 Re:RequestofConfidentialityforFCCID:ZMOLE271GL ToWhomitmayconcern: Pursuanttosections0.457and0.459ofCommissionโsRules(CFR47), andSection552(b)(4)oftheFreedomofInformationAct,FibocomWirelessInc. herebyrequestsconfidentialityandtreatmentofcertaininformation accompanyingthisapplication.Thematerialscontaintradesecretsand proprietaryinformationnotcustomarilyreleasedtothepublic.Thepublic disclosureofthesemattersmightbeharmfultotheApplicantandprovide unjustifiedbenefitstoitscompetitors. WearealsoherebyrequestShort-TermConfidentialityfor180daysafterthegrant asoutlinedinPublicNoticeDA04-1705.ThisprovisionwillgiveFibocom WirelessInc.temporaryconfidentialityofcommerciallysensitiveinformationprior toproductrelease. TherequestedPermanentandShort-TermConfidentialexhibitsarelistedas follows: PERMANENTANDSHORT-TERMCONFIDENTIALLIST ExhibitDescription PERMANENT 1BlockDiagram 2OperationalDescription 3Schematics 4BOM 5TuneUp SHORT-TERM 6ExternalPhotos 7InternalPhotos 8Test-SetupPhotos 9UserManual TheApplicantunderstandsthatpursuanttoRule0.457,disclosureofthis applicationandallaccompanyingdocumentations,whereapplicable,willnotbe madepublicbeforethedateoftheGrantforthisapplication. Signatory: Name:PatrickMa Companyname:FibocomWirelessInc. Address:1101,TowerA,Building6,ShenzhenInternationalInnovationValley, Dashi1stRd,Nanshan,Shenzhen,China Tel:+8675526733555 Email:[email protected]
FibocomWirelessInc. version01 ModularApprovalRequestLetter Date:2026-01-21 FCCID:ZMOLE271GL TypeofEquipment:LTEModule ThefollowingrequirementsaccordingtoFCCPart15.212aremet: iRFshielding Theradioportionhashisownshielding(seeexternalphotos). iiBufferedmodulation/datainputs hasbeenintegratedinthechipset iiiPowersupplyregulation isintegrated ivAntennarequirementssection15.203,15.204band15.204c Themodulecomeswithonepermanentlyattachedantennas.Thespuriousemission requirementsarefulfilled(seeattachedtestreport). vStandalonetestconfiguration Pleasereferringtotestsetupconfigurationphoto viLabelling Themodulehasitsownlabel.Theinstructionforlabellingrulesforthehostdevicehasbeen statedintheusersmanual viiComplianceonspecificruleoroperatingrequirements TherequiredFCCruleshasbeenfulfilledandallinstructionsformaintainingcompliancehas beenclearlystatedintheusersmanual viiiRFExposure RFexposurerequirementsarefulfilledformobileconfiguration.Theinstallationofthemoduleis restrictedtomobilehostdeviceswhatisclearlystatedintheinstallationinstructionoftheuser manual. ForportableapplicationsOEMintegratorsneedSARevaluationandanownFCCID. Name:PatrickMa Title:CertificationDirector Company:FibocomWirelessInc.
LE271-GL Label & Label Location ๏ฌ EUT Dimension(mm)๏ผ14.4*16.3 ๏ฌ Label ๏ฌ Label Location (On the top of the EUT)
MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผSZ25120010S01 Annex B Conducted Power Note: Conducted power unit: dBm The target power was recorded in the manufacturer's document. BW [MHz]ModulationRB SizeRB OffsetLow Channel Middle Channel High Channel BW [MHz]ModulationRB SizeRB OffsetLow Channel Middle Channel High Channel 187001890019100200502017520300 18601880190017201732.51745 20QPSK1023.1123.0923.2720QPSK1023.1623.1223.09 20QPSK14922.9122.9522.8820QPSK14922.7722.7822.88 20QPSK19922.8522.9222.8920QPSK19922.6922.7122.83 20QPSK50022.4122.4822.4420QPSK50022.2522.3622.29 20QPSK502422.4322.3722.3520QPSK502422.2122.2422.32 20QPSK505022.4022.4322.3620QPSK505022.1822.2122.23 20QPSK100022.4322.4422.3320QPSK100022.1522.2422.28 2016QAM1022.1022.0121.842016QAM1021.8822.1322.08 2016QAM11221.9822.0722.022016QAM11222.1322.1922.13 2016QAM12422.0821.8522.122016QAM12422.2022.1922.11 2016QAM25020.5820.5320.572016QAM25021.2421.2021.34 2016QAM252420.7920.6420.632016QAM252421.2721.1621.29 2016QAM254920.6620.6920.712016QAM254921.3221.1821.28 2064QAM1020.7420.8820.832064QAM1021.3621.3021.43 2064QAM1520.7721.0320.712064QAM1521.1621.1821.43 2064QAM11120.8720.7520.712064QAM11121.2621.2721.47 2064QAM6020.5320.4220.422064QAM6020.6020.5720.67 2064QAM6220.3620.3720.442064QAM6220.5920.6120.83 2064QAM6620.4920.4220.472064QAM6620.6320.6020.87 2064QAM12020.4120.4420.432064QAM12020.6120.5820.78 186751890019125200252017520325 1857.518801902.51717.51732.51747.5 15QPSK1022.7922.8522.8115 QPSK1022.9923.0923.03 15QPSK13722.7822.8222.7515QPSK13722.8622.8722.88 15QPSK17422.7222.7922.7615QPSK17422.7822.8022.83 15QPSK36022.4922.4222.4515QPSK36022.3422.3722.29 15QPSK362022.4422.3822.3615QPSK362022.3022.3322.32 15QPSK363922.4122.4422.3715QPSK363922.2722.3022.36 15QPSK75022.4422.4522.3415QPSK75022.2422.3322.28 1516QAM 10 22.1122.0221.851516QAM 10 21.9722.2222.28 1516QAM 112 21.9922.0822.031516QAM 112 22.2222.2822.13 1516QAM 124 22.0921.8622.131516QAM 124 22.2922.2822.39 1516QAM 250 20.6420.5920.631516QAM 250 21.3321.2921.34 1516QAM 2524 20.8520.7020.691516QAM 2524 21.3621.2521.29 1516QAM 2549 20.7220.7520.771516QAM 2549 21.4121.2721.28 1564QAM1020.8020.9420.891564QAM1021.4521.3921.43 1564QAM1520.8320.8720.771564QAM1521.2521.2721.43 1564QAM11120.9320.8120.631564QAM11121.3521.3621.47 1564QAM6020.4020.2920.291564QAM6020.6920.6620.67 1564QAM6220.2320.2420.311564QAM6220.6820.7020.83 1564QAM6620.3620.2920.341564QAM6620.7220.6920.87 1564QAM12020.2820.3120.301564QAM12020.7020.6720.78 186501890019150200002017520350 18551880190517151732.51750 10QPSK1022.7022.7622.7210QPSK1022.8422.9422.88 10QPSK12522.6922.7322.6610QPSK12522.7122.7222.73 10QPSK14922.6322.7022.6710QPSK14922.6322.6522.68 10QPSK25022.3922.3222.3510QPSK25022.1922.2222.14 10QPSK251222.3422.2822.2610QPSK251222.1522.1822.17 10QPSK252522.3122.3422.2710QPSK252522.1222.1522.21 10QPSK50022.3422.3522.2410QPSK50022.0922.1822.13 1016QAM1022.0121.9221.751016QAM1021.8222.0722.13 1016QAM11221.8921.9821.931016QAM11222.0722.1321.98 1016QAM12421.9921.7622.031016QAM12422.1422.1322.24 1016QAM25020.5520.5020.541016QAM25021.1821.1421.19 1016QAM252420.7620.6120.601016QAM252421.2121.1021.14 1064QAM1020.7120.8520.801064QAM1021.3021.2421.28 1064QAM1520.7420.7820.681064QAM1521.1021.1221.28 1064QAM11120.8420.7220.541064QAM11121.2021.2121.32 1064QAM6020.3120.2020.201064QAM6020.5420.5120.52 1064QAM6220.1420.1520.221064QAM6220.5320.5520.68 1064QAM6620.27 20.2020.251064QAM6620.5720.5420.72 1064QAM12020.1920.2220.211064QAM12020.5520.5220.63 186251890019175199752017520375 1852.518801907.51712.51732.51752.5 5QPSK1022.6122.7222.635QPSK1022.7722.8922.81 5QPSK11222.6022.6422.575QPSK11222.6422.6522.66 5QPSK12422.5422.6122.585QPSK12422.5622.5822.61 5QPSK12022.2922.2222.255QPSK12022.1222.1522.07 5QPSK12722.2422.1822.165QPSK12722.0822.1122.10 5QPSK121322.2122.2422.175QPSK121322.0522.0822.14 5QPSK25022.2422.2522.145QPSK25022.0222.1122.06 516QAM1021.9121.8221.65516QAM1021.7522.0022.06 516QAM11221.7921.8821.83516QAM11222.0022.0621.91 516QAM12421.8921.6621.93516QAM12422.0722.0622.17 516QAM12020.6520.6020.64516QAM12021.1121.0721.12 516QAM12720.8620.7120.70516QAM12721.1421.0321.07 516QAM121320.7320.7620.78516QAM121321.1921.0521.06 516QAM25020.7120.7320.69516QAM25021.1121.1021.08 564QAM1020.8120.9520.90564QAM1021.2321.1721.21 564QAM1520.8420.8820.78564QAM1521.0321.0521.21 564QAM11120.9420.8220.64564QAM11121.1321.1421.25 564QAM6020.2220.1120.11564QAM6020.4720.4420.45 564QAM6220.0520.0620.13564QAM6220.4620.4820.61 564QAM6620.1820.1120.16564QAM6620.5020.4720.65 564QAM12020.1020.1320.12564QAM12020.4820.4520.56 186151890019185199652017520385 1851.518801908.51711.51732.51753.5 3QPSK10 22.5222.6322.543 QPSK1022.7322.8322.77 3QPSK1822.5122.5522.483QPSK1822.6022.6122.62 3QPSK11422.4522.5222.493QPSK11422.5222.5422.57 3QPSK8022.2022.1322.163QPSK8022.0822.1122.03 3QPSK8422.1522.0922.073QPSK8422.0422.0722.06 3QPSK8722.1222.1522.083QPSK8722.0122.0422.10 3QPSK15022.1522.1622.053QPSK15021.9822.0722.02 316QAM1021.8221.7321.56316QAM1021.8721.8421.90 316QAM1821.7021.7921.74316QAM1821.8421.9021.75 316QAM11421.8021.5721.84316QAM11421.9121.9022.01 316QAM8020.5620.5120.55316QAM8020.9720.9320.98 316QAM8420.7720.6220.61316QAM8421.0020.8920.93 316QAM8720.6420.6720.69316QAM8721.0520.9120.92 316QAM15020.6220.6420.60316QAM15020.9720.9620.94 364QAM1020.7220.8620.81364QAM1021.0921.0321.07 364QAM1520.7520.7920.69364QAM1520.8920.9121.07 364QAM11120.8520.7320.55364QAM11120.9921.0021.11 364QAM6020.1320.0220.02364QAM6020.4320.4020.41 ChannelChannel Frequency (MHz)Frequency (MHz) Frequency (MHz)Frequency (MHz) ChannelChannel ChannelChannel Frequency (MHz)Frequency (MHz) ChannelChannel Frequency (MHz)Frequency (MHz) ChannelChannel Frequency (MHz)Frequency (MHz) Tune-up limit (dBm) 25 24 24 23 23 22 Tune-up limit (dBm) 25 2โฆ
Text truncated - open the document above for the full version.
NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 9 REPORT No.๏ผSZ25120010S01 RF EXPOSURE EVALUATION REPORT APPLICANT : Fibocom Wireless Inc. PRODUCT NAME : LTE Module MODEL NAME : LE271-GL BRAND NAME : Fibocom FCC ID : ZMOLE271GL STANDARD(S) : FCC 47CFR Part 2(2.1091) RECEIPT DATE : 2025-12-03 TEST DATE : 2025-12-16 ISSUE DATE : 2026-01-22 Edited by: Pang Siyu (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผSZ25120010S01 Page 2 of 9 DIRECTORY 1. Technical Information ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 1.1 Applicant and Manufacturer Information ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 1.2 Equipment under Test (EUT) Description ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 1.3 Applied Reference Documents ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 2. Device Category and RF Exposure Limit ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 3. Maximum Average Power Summary ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 4. RF Exposure Assessment ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 Annex A General Information ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 Change History Version Date Reason for Change 1.0 2026-01-22 First edition Note: The latest revision of the report supersedes all previous version. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผSZ25120010S01 Page 3 of 9 1. Technical Information Note: Provide by applicant. 1.1 Applicant and Manufacturer Information Applicant: Fibocom Wireless Inc. Applicant Address: 1101,Tower A, Building 6, Shenzhen International Innovation Valley, Dashi 1st Rd, Nanshan,Shenzhen, China. Manufacturer: Fibocom Wireless Inc. Manufacturer Address: 1101,Tower A, Building 6, Shenzhen International Innovation Valley, Dashi 1st Rd, Nanshan,Shenzhen, China. 1.2 Equipment under Test (EUT) Description Product Name: LTE Module Serial No: 10# Hardware Version: V1.2 Software Version: 12007.6000.00.05.84.04 Frequency Bands: LTE Band 2: 1850 MHz ~ 1910 MHz LTE Band 4: 1710 MHz ~ 1755 MHz LTE Band 5: 824 MHz ~ 849 MHz LTE Band 7: 2500 MHz ~ 2570 MHz LTE Band 12: 699 MHz ~ 716 MHz LTE Band 13: 777 MHz ~ 787 MHz LTE Band 14: 788 MHz ~ 798 MHz LTE Band 17: 704 MHz ~ 716 MHz LTE Band 25: 1850 MHz ~ 1915 MHz LTE Band 26: 814 MHz ~ 849 MHz LTE Band 38: 2570 MHz ~ 2620 MHz LTE Band 41: 2496 MHz ~ 2690 MHz LTE Band 66: 1710 MHz ~ 1780 MHz Modulation Mode: LTE: QPSK, 16QAM, 64QAM Antenna Type: External Rod Antenna Antenna Gain: Wireless Mode Antenna Gain (dBi) LTE Band 2 7.43 LTE Band 4 6.23 LTE Band 5 7.41 LTE Band 7 7.50 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผSZ25120010S01 Page 4 of 9 LTE Band 12 7.99 LTE Band 13 8.66 LTE Band 14 8.66 LTE Band 17 7.99 LTE Band 25 7.43 LTE Band 26 8.91 LTE Band 38 7.49 LTE Band 41 7.50 LTE Band 66 6.38 Note: The declarations of EUT presented in the report are provided by applicant and/or manufacturer, and the test laboratory is not responsible for the accuracy of the information. 1.3 Applied Reference Documents Leading reference documents for testing: Identity Document Title Remark FCC 47CFR Part 2(2.1091) Radio Frequency Radiation Exposure Assessment: mobile devices / KDB 447498 D01v06 General RF Exposure Guidance / Note: Any additions, deviation, or exclusions from the method shall be noted in the โRemarkโ. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผSZ25120010S01 Page 5 of 9 2. Device Category and RF Exposure Limit Per user manual, Based on 47CFR 2.1091, this device belongs to mobile device category with General Population/Uncontrolled exposure. Mobile Devices: 47CFR 2.1091(b) For purposes of this section, a mobile device is defined as a transmitting device designed to be used in other than fixed locations and to generally be used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitter's radiating structure(s) and the body of the user or nearby persons. In this context, the term โfixed locationโ means that the device is physically secured at one location and is not able to be easily moved to another location. Transmitting devices โฆ
Text truncated - open the document above for the full version.
NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 436 REPORT No.๏ผSZ25120010W01 TEST REPORT APPLICANT : Fibocom Wireless Inc. PRODUCT NAME : LTE Module MODEL NAME :LE271-GL BRAND NAME : Fibocom FCC ID :ZMOLE271GL STANDARD(S) : 47 CFR Part 2 47 CFR Part 22, Subpart H 47 CFR Part 24, Subpart E 47 CFR Part 27, Subpart F&H&L&M&N RECEIPT DATE : 2025-12-03 TEST DATE :2025-12-17 to 2026-01-08 ISSUE DATE :2026-02-04 Edited by: Peng Mi (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 436 REPORT No.๏ผSZ25120010W01 DIRECTORY 1. Technical Information ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 1.1. Applicant and Manufacturer Information ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 1.2. Equipment Under Test (EUT) Description ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 1.3. Maximum Conducted Output Power and Emission Designator ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 1.4. Test Standards and Results ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 1.5. Environmental Conditions ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 2. 47 CFR Part 2, Part 22H, Part 24E, Part 27 F&H&L&M&N Requirements ยทยทยทยทยทยทยทยทยทยทยทยทยทยท 10 2.1. Transmitter Conducted Output Power and E.R.P./E.I.R.P. ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 10 2.2. Occupied Bandwidth ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 118 2.3. Frequency Stability ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 221 2.4. Peak to Average Radio ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 234 2.5. Conducted Spurious Emissions ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 279 2.6. Band Edge ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 314 2.7. Radiated Spurious Emissions ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 355 Annex A Test Uncertainty ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 432 Annex B Testing Laboratory Information ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 433 Change History Version Date Reason for change 1.0 2026-02-04 First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 436 REPORT No.๏ผSZ25120010W01 1. Technical Information Note: Provide by applicant. 1.1. Applicant and Manufacturer Information Applicant: Fibocom Wireless Inc. Applicant Address: 1101,Tower A, Building 6, Shenzhen International Innovation Valley, Dashi 1 st Rd, Nanshan, Shenzhen, China. Manufacturer: Fibocom Wireless Inc. Manufacturer Address: 1101,Tower A, Building 6, Shenzhen International Innovation Valley, Dashi 1 st Rd, Nanshan, Shenzhen, China. 1.2. Equipment Under Test (EUT) Description Product Name: LTE Module Sample No.: 1#, 9# Hardware Version: V1.2 Software Version: 12007.6000.00.05.84.04 Modulation Type: QPSK, 16QAM, 64QAM UE Category: Cat 1bis Operation Band: Band 2 / 4 / 5 / 7 / 12 / 13 / 17 / 25 / 26 / 38 / 41 / 66 Frequency Range: LTE Band 2 Tx: 1850MHzโ1910MHz Rx: 1930MHzโ1990MHz LTE Band 4 Tx: 1710MHzโ1755MHz Rx: 2110MHzโ2155MHz LTE Band 5 Tx: 824MHzโ849MHz Rx: 869MHzโ894MHz LTE Band 7 Tx: 2500MHzโ2570MHz Rx: 2620MHzโ2690MHz LTE Band 12 Tx: 699MHzโ716MHz Rx: 729MHzโ746MHz LTE Band 13 Tx: 777MHzโ787MHz Rx: 746MHzโ756MHz LTE Band 17 Tx: 704MHzโ716MHz Rx: 734MHzโ746MHz MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 4 of 436 REPORT No.๏ผSZ25120010W01 Frequency Range: LTE Band 25 Tx: 1850MHzโ1915MHz Rx: 1930MHzโ1995MHz LTE Band 26 Tx: 824MHzโ849MHz Rx: 869MHzโ894MHz LTE Band 38 Tx: 2570MHzโ2620MHz Rx: 2570MHzโ2620MHz LTE Band 41 Tx: 2496MHzโ2690MHz Rx: 2496MHzโ2690MHz LTE Band 66 Tx: 1710MHz โ1780MHz Rx: 2110MHzโ2200MHz Channel Bandwidth: LTE Band 2 1.4MHz, 3MHz, 5MHz, 10MHz, 15MHz, 20MHz LTE Band 4 1.4MHz, 3MHz, 5MHz, 10MHz, 15MHz, 20MHz LTE Band 5 1.4MHz, 3MHz, 5MHz, 10MHz LTE Band 7 5MHz, 10MHz, 15MHz, 20MHz LTE Band 12 1.4MHz, 3 MHz, 5MHz, 10MHz LTE Band 13 5MHz, 10MHz LTE Band 17 5MHz, 10MHz LTE Band 25 1.4MHz, 3MHz, 5MHz, 10MHz, 15MHz, 20MHz LTE Band 26 1.4MHz, 3MHz, 5MHz, 10MHz, 15MHz LTE Band 38 5 MHz, 10MHz, 15MHz, 20MHz LTE Band 41 5 MHz, 10MHz, 15MHz, 20MHz LTE Band 66 1.4MHz, 3MHz, 5MHz, 10MHz, 15MHz, 20MHz Antenna Type: External Rod Antenna Antenna Gain: LTE Band 2 7.43dBi LTE Band 4 6.23dBi LTE Band 5 7.41dBi LTE Band 7 7.50dBi LTE Band 12 7.99dBi LTE Band 13 8.66dBi LTE Band 17 7.99dBi LTE Band 25 7.43dBi LTE Band 26 8.91dBi LTE Band 38 7.49dBi LTE Band 41 7.50dBi LTE Band 66 6.38dBi Note 1: The EUT description presented in the report are provided by applicโฆ
Text truncated - open the document above for the full version.
MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 191 of 436 REPORT No.๏ผSZ25120010W01 B25 / 20MHz / QPSK/ Mid CH B25 / 20MHz / 16QAM/ Mid CH B25 / 20MHz / 64QAM/ Mid CH B25 / 20MHz / QPSK/ High CH B25 / 20MHz / 16QAM/ High CH B25 / 20MHz / 64QAM/ High CH MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 192 of 436 REPORT No.๏ผSZ25120010W01 B26 Part22 / 1.4MHz / QPSK/ Low CH B26 Part22 / 1.4MHz / 16QAM/ Low CH B26 Part22 / 1.4MHz / 64QAM/ Low CH B26 Part22 / 1.4MHz / QPSK/ Mid CH B26 Part22 / 1.4MHz / 16QAM/ Mid CH B26 Part22 / 1.4MHz / 64QAM/ Mid CH MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 193 of 436 REPORT No.๏ผSZ25120010W01 B26 Part22 / 1.4MHz / QPSK/ High CH B26 Part22 / 1.4MHz / 16QAM/ High CH B26 Part22 / 1.4MHz / 64QAM/ High CH B26 Part22 / 3MHz / QPSK/ Low CH B26 Part22 / 3MHz / 16QAM/ Low CH B26 Part22 / 3MHz / 64QAM/ Low CH MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 194 of 436 REPORT No.๏ผSZ25120010W01 B26 Part22 / 3MHz / QPSK/ Mid CH B26 Part22 / 3MHz / 16QAM/ Mid CH B26 Part22 / 3MHz / 64QAM/ Mid CH B26 Part22 / 3MHz / QPSK/ High CH B26 Part22 / 3MHz / 16QAM/ High CH B26 Part22 / 3MHz / 64QAM/ High CH MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 195 of 436 REPORT No.๏ผSZ25120010W01 B26 Part22 / 5MHz / QPSK/ Low CH B26 Part22 / 5MHz / 16QAM/ Low CH B26 Part22 / 5MHz / 64QAM/ Low CH B26 Part22 / 5MHz / QPSK/ Mid CH B26 Part22 / 5MHz / 16QAM/ Mid CH B26 Part22 / 5MHz / 64QAM/ Mid CH MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 196 of 436 REPORT No.๏ผSZ25120010W01 B26 Part22 / 5MHz / QPSK/ High CH B26 Part22 / 5MHz / 16QAM/ High CH B26 Part22 / 5MHz / 64QAM/ High CH B26 Part22 / 10MHz / QPSK/ Low CH B26 Part22 / 10MHz / 16QAM/ Low CH B26 Part22 / 10MHz / 64QAM/ Low CH MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 197 of 436 REPORT No.๏ผSZ25120010W01 B26 Part22 / 10MHz / QPSK/ Mid CH B26 Part22 / 10MHz / 16QAM/ Mid CH B26 Part22 / 10MHz / 64QAM/ Mid CH B26 Part22 / 10MHz / QPSK/ High CH B26 Part22 / 10MHz / 16QAM/ High CH B26 Part22 / 10MHz / 64QAM/ High CH MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 198 of 436 REPORT No.๏ผSZ25120010W01 B26 Part22 / 15MHz / QPSK/ Low CH B26 Part22 / 15MHz / 16QAM/ Low CH B26 Part22 / 15MHz / 64QAM/ Low CH B26 Part22 / 15MHz / QPSK/ Mid CH B26 Part22 / 15MHz / 16QAM/ Mid CH B26 Part22 / 15MHz / 64QAM/ Mid CH MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 199 of 436 REPORT No.๏ผSZ25120010W01 B26 Part22 / 15MHz / QPSK/ High CH B26 Part22 / 15MHz / 16QAM/ High CH B26 Part22 / 15MHz / 64QAM/ High CH MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 200 of 436 REPORT No.๏ผSZ25120010W01 B38 / 5MHz / QPSK/ Low CH B38 / 5MHz / 16QAM/ Low CH B38 / 5MHz / 64QAM/ Low CH B38 / 5MHz / QPSK/ Mid CH B38 / 5MHz / 16QAM/ Mid CH B38 / 5MHz / 64QAM/ Mid CH MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 201 of 436 REPORT No.๏ผSZ25120010W01 B38 / 5MHz / QPSK/ High CH B38 / 5MHz / 16QAM/ Hโฆ
Text truncated - open the document above for the full version.
5909 Peachtree Dunwoody Rd Ste 910 Atlanta, GA 303 ยท Atlanta, 30328 ยท United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 22H | 829 MHz - 844 MHz | 220.00 mW | 8M99G7D | 0.027ppm |
| 2 | 22H | 829 MHz - 844 MHz | 174.00 mW | 4M52W7D | 0.027ppm |
| 3 | 22H | 825.5 MHz - 847.5 MHz | 177.00 mW | 2M72W7D | 0.027ppm |
| 4 | 22H | 831.5 MHz - 841.5 MHz | 229.00 mW | 13M5G7D | 0.024ppm |
| 5 | 22H | 831.5 MHz - 841.5 MHz | 209.00 mW | 4M55W7D | 0.024ppm |
| 6 | 22H | 829 MHz - 844 MHz | 232.00 mW | 4M53W7D | 0.024ppm |
| 7 | 24E | 1.86 GHz - 1.90 GHz | 212.00 mW | 17M9G7D | 0.011ppm |
| 8 | 24E | 1.86 GHz - 1.90 GHz | 163.00 mW | 4M54W7D | 0.011ppm |
| 9 | 24E | 1.86 GHz - 1.90 GHz | 163.00 mW | 4M55W7D | 0.011ppm |
| 1 | 24E | 1.86 GHz - 1.91 GHz | 205.00 mW | 17M9G7D | 0.011ppm |
| 11 | 24E | 1.86 GHz - 1.91 GHz | 152.00 mW | 4M55W7D | 0.011ppm |
| 12 | 24E | 1.85 GHz - 1.91 GHz | 167.00 mW | 4M52W7D | 0.011ppm |
| 13 | 27 | 1.72 GHz - 1.75 GHz | 207.00 mW | 17M9G7D | 0.013ppm |
| 14 | 27 | 1.72 GHz - 1.75 GHz | 166.00 mW | 4M56W7D | 0.013ppm |
| 15 | 27 | 1.72 GHz - 1.75 GHz | 173.00 mW | 4M54W7D | 0.013ppm |
| 16 | 27 | 2.51 GHz - 2.56 GHz | 202.00 mW | 17M9G7D | 0.009ppm |
| 17 | 27 | 2.51 GHz - 2.56 GHz | 149.00 mW | 4M55W7D | 0.009ppm |
| 18 | 27 | 704 MHz - 711 MHz | 217.00 mW | 9M00G7D | 0.033ppm |
| 19 | 27 | 704 MHz - 711 MHz | 182.00 mW | 4M52W7D | 0.033ppm |
| 2 | 27 | 782 MHz - 782 MHz | 233.00 mW | 8M97G7D | 0.028ppm |
| 21 | 27 | 782 MHz - 782 MHz | 196.00 mW | 4M51W7D | 0.028ppm |
| 22 | 27 | 709 MHz - 711 MHz | 225.00 mW | 8M99G7D | 0.028ppm |
| 23 | 27 | 709 MHz - 711 MHz | 191.00 mW | 4M53W7D | 0.028ppm |
| 24 | 27 | 2.58 GHz - 2.61 GHz | 261.00 mW | 17M9G7D | 0.008ppm |
| 25 | 27 | 2.58 GHz - 2.61 GHz | 215.00 mW | 4M54W7D | 0.008ppm |
| 26 | 27 | 2.51 GHz - 2.68 GHz | 261.00 mW | 17M9G7D | 0.009ppm |
| 27 | 27 | 2.51 GHz - 2.68 GHz | 215.00 mW | 4M54W7D | 0.009ppm |
| 28 | 27 | 1.72 GHz - 1.77 GHz | 225.00 mW | 17M9G7D | 0.011ppm |
| 29 | 27 | 1.72 GHz - 1.77 GHz | 172.00 mW | 4M55W7D | 0.011ppm |
| 3 | 9 | 793 MHz - 793 MHz | 231.00 mW | 8M96G7D | 0.029ppm |
| 31 | 9 | 793 MHz - 793 MHz | 187.00 mW | 4M52W7D | 0.029ppm |
| 32 | 9 | 790.5 MHz - 795.5 MHz | 189.00 mW | 4M50W7D | 0.029ppm |
| 33 | 9 | 819 MHz - 819 MHz | 229.00 mW | 9M01G7D | 0.028ppm |
| 34 | 9 | 819 MHz - 819 MHz | 203.00 mW | 4M54W7D | 0.028ppm |
| 35 | 9 | 814.7 MHz - 823.3 MHz | 234.00 mW | 1M10G7D | 0.028ppm |
| 36 | 9 | 816.5 MHz - 821.5 MHz | 224.00 mW | 4M51W7D | 0.028ppm |
5G Module
Equipment Class
NII - Unlicensed National Information Infrastructure TXSC138-NA
Equipment Class
PCB - PCS Licensed Transmitter5G Dongle
Equipment Class
CXX - Communications Rcvr for use w/ licensed Tx and CBsLTE Module
Equipment Class
PCB - PCS Licensed TransmitterWIFI Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter